期刊文献+
共找到3,264篇文章
< 1 2 164 >
每页显示 20 50 100
Seismic Behavior of Diaphragm-Through Connections of Concrete-Filled Square Steel Tubular Columns and H-Shaped Steel Beams 被引量:6
1
作者 荣彬 陈志华 +1 位作者 Apostolos Fafitis 苗纪奎 《Transactions of Tianjin University》 EI CAS 2013年第3期195-201,共7页
Based on the introductions of a type of diaphragm-through connection between concrete-filled square steel tubular columns (CFSSTCs) and H-shaped steel beams,a finite element model of the connection is developed and us... Based on the introductions of a type of diaphragm-through connection between concrete-filled square steel tubular columns (CFSSTCs) and H-shaped steel beams,a finite element model of the connection is developed and used to investigate the seismic behavior of the connection.The results of the finite element model are validated by a set of cyclic loading tests.The cyclic loading tests and the finite element analyses indicate that the failure mode of the suggested connections is plastic hinge at the beam with inelastic rotation angle exceeding 0.04 rad.The suggested connections have sufficient strength,plastic deformation and energy dissipation capacity to be used in composite moment frames as beam-to-column rigid connections. 展开更多
关键词 concrete-filled square steel tubular column H-shaped steel beam diaphragm-through connection seismic behavior load transfer mechanism
下载PDF
Axial Bearing Capacity of Short FRP Confined Concrete-filled Steel Tubular Columns 被引量:7
2
作者 刘兰 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2010年第3期454-458,共5页
The bearing capacity of FRP confined concrete-filled steel tubular (FRP-CFST) columns under axial compression was investigated. This new type of composite column is a concrete-filled steel tube (CFST) confined wit... The bearing capacity of FRP confined concrete-filled steel tubular (FRP-CFST) columns under axial compression was investigated. This new type of composite column is a concrete-filled steel tube (CFST) confined with fiber-reinforced polymer (FRP) wraps. Totally 11 short column specimens were tested to failure under axial compression. The influences of the type and quantity of FRP, the thickness of steel tube and the concrete strength were studied. It was found that the bearing capacity of short FRP-CFST column was much higher than that of comparable CFST column. Furthermore, the formulas for calculating the bearing capacity of the FRP-CFST columns are proposed. The analytical calculated results agree well with the experimental results. 展开更多
关键词 columnS concrete-filled steel tubes (CFST) fiber reinforced polymer (FRP) CONFINEMENT bearing capacity.
下载PDF
Influence of Axial Load Ratio on Shear Behavior of Through-Diaphragm Connections of Concrete-Filled Square Steel Tubular Columns 被引量:2
3
作者 张广泰 韩建红 +1 位作者 荣彬 Apostolos Fafitis 《Transactions of Tianjin University》 EI CAS 2015年第4期341-346,共6页
Nonlinear finite element analysis and parametric studies were carried out to study the influence of axial load ratio on the shear behavior of the through-diaphragm connections of concrete-filled square steel tubular c... Nonlinear finite element analysis and parametric studies were carried out to study the influence of axial load ratio on the shear behavior of the through-diaphragm connections of concrete-filled square steel tubular columns. The analysis reveals that smaller axial load ratio can improve the shear bearing capacity and ductility while larger axial load ratio will decrease the shear behavior of the through-diaphragm connections. The parametric studies indicate that the axial load ratio should be limited to less than 0.4 and its influence should be considered in the analysis and design of such connections. 展开更多
关键词 through-diaphragm connection concrete-filled square steel tubular column AXIAL load ratio shearbearing capacity DUCTILITY
下载PDF
Damage assessment for seismic response of recycled concrete filled steel tube columns 被引量:4
4
作者 Huang Yijie Xiao Jianzhuang Shen Luming 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2016年第3期607-616,共10页
A model for evaluating structural damage of recycled aggregate concrete filled steel tube (RCFST) columns under seismic effects is proposed in this paper. The proposed model takes the lateral deformation and the eff... A model for evaluating structural damage of recycled aggregate concrete filled steel tube (RCFST) columns under seismic effects is proposed in this paper. The proposed model takes the lateral deformation and the effect of repeated cyclic loading into account. Available test results were collected and utilized to calibrate the parameters of the proposed model. A seismic test for six RCFST columns was also performed to validate the proposed damage assessment model. The main test parameters were the recycled coarse aggregate (RCA) replacement percentage and the bond-slip property. The test results indicated that the seismic performance of the RCFST member depends on the RCA contents and their damage index increases as the RCA replacement percentage increases. It is also indicated that the damage degree of RCFST changes with the variation of the RCA replacement percentage. Finally, comparisons between the RCA contents, lateral deformation ratio and damage degree were implemented. It is suggested that an improvement procedure should be implemented in order to compensate for the performance difference between the RCFST and normal concrete filled steel tubes (CFST). 展开更多
关键词 recycled aggregate concrete (RAC) recycled concrete filled steel tube (RCFST) column seismicperformance damage assessment model (DAM)
下载PDF
Numerical analysis of ultimate strength of concrete filled steel tubular arch bridges 被引量:5
5
作者 谢旭 陈衡治 +1 位作者 李辉 宋世锐 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第8期859-868,共10页
The calculation of ultimate bearing capacity is a significant issue in the design of Concrete Filled Steel Tubular (CFST) arch bridges. Based on the space beam theory, this paper provides a calculation method for dete... The calculation of ultimate bearing capacity is a significant issue in the design of Concrete Filled Steel Tubular (CFST) arch bridges. Based on the space beam theory, this paper provides a calculation method for determining the ultimate strength of CFST structures. The accuracy of this method and the applicability of the stress-strain relationships were validated by comparing different existing confined concrete uniaxial constitutive relationships and experimental results. Comparison of these results indicated that this method using the confined concrete uniaxial stress-strain relationships can be used to calculate the ultimate strength and CFST behavior with satisfactory accuracy. The calculation results are stable and seldom affected by concrete con-stitutive relationships. The method is therefore valuable in the practice of engineering design. Finally, the ultimate strength of an arch bridge with span of 330 m was investigated by the proposed method and the nonlinear behavior was discussed. 展开更多
关键词 concrete filled steel tubular (CFST) Confined concrete Stress-strain relationship Ultimate strength
下载PDF
Approach for analyzing the ultimate strength of concrete filled steel tubular arch bridges with stiffening girder 被引量:6
6
作者 ZHANG Zhi-cheng XIE Xu +1 位作者 ZHANG He CHEN Heng-zhi 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第5期682-692,共11页
A convenient approach is proposed for analyzing the ultimate load carrying capacity of concrete filled steel tubular (CFST) arch bridge with stiffening girders. A fiber model beam element is specially used to simulate... A convenient approach is proposed for analyzing the ultimate load carrying capacity of concrete filled steel tubular (CFST) arch bridge with stiffening girders. A fiber model beam element is specially used to simulate the stiffening girder and CFST arch rib. The geometric nonlinearity, material nonlinearity, influence of the construction process and the contribution of prestressing reinforcement are all taken into consideration. The accuracy of this method is validated by comparing its results with experimental results. Finally, the ultimate strength of an abnormal CFST arch bridge with stiffening girders is investigated and the effect of construction method is discussed. It is concluded that the construction process has little effect on the ultimate strength of the bridge. 展开更多
关键词 Ultimate strength concrete filled steel tubular (CFST) arch bridge Stiffening girder Fiber model beam element Construction process
下载PDF
Seismic performance of recycled concrete-filled square steel tube columns 被引量:9
7
作者 Chen Zongping Jing Chenggui +1 位作者 Xu Jinjun Zhang Xianggang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第1期119-130,共12页
An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic later... An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic lateral loading. Two parameters, replacement percentage of recycled coarse aggregate (RCA) and axial compression level, were considered in the test. Based on the experimental data, the hysteretic loops, skeleton curves, ductility, energy dissipation capacity and stiffness degradation of RCFST columns were analyzed. The test results indicate that the failure modes of RCFST columns are the local buckling of the steel tube at the bottom of the columns, and the hysteretic loops are full and their shapes are similar to normal CFST columns. Furthermore, the ductility coefficient of all specimens are close to 3.0, and the equivalent viscous damping coefficient corresponding to the ultimate lateral load ranges from 0.323 to 0.360, which demonstrates that RCFST columns exhibit remarkable seismic performance. 展开更多
关键词 recycled concrete-filled square steel tube (RCFST) column replacement percentage cyclic loading seismicperformance
下载PDF
Bearing capacity of composite columns reinforced by concrete filled steel tube 被引量:1
8
作者 韦建刚 ZHU Pu CHEN Bao-chun 《Journal of Chongqing University》 CAS 2013年第1期27-34,共8页
In this study, nine simplified short composite columns consisting of core CFST (concrete filled steel tube) of different diameters and outer reinforced concrete were constructed to study their compressive performance ... In this study, nine simplified short composite columns consisting of core CFST (concrete filled steel tube) of different diameters and outer reinforced concrete were constructed to study their compressive performance under axial or eccentric compression. The failure mode is characterized by the crush of the outer concrete. The bearing capacity increases at first and then decreases with further increase of the position coefficient. It can be concluded that position coefficient is an important structural parameter that has considerable influences on the ultimate bearing capacity of the composite columns. The outer concrete, steel tubes and longitudinal reinforcement are found to work in a cooperative manner under axial or eccentric compression when the position coefficient is about 0.5. An improved bearing capacity algorithm that takes the position coefficient into account has been proposed based on the experimental and simulation results and current technical specification in China. It has been proven to be precise and safe. 展开更多
关键词 concrete filled steel tube composite column position factor TEST FORMULA
下载PDF
Three-dimensional nonlinear analysis of creep in concrete filled steel tube columns 被引量:1
9
作者 程晓东 李广宇 叶贵如 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第8期826-835,共10页
This paper proposes a based on 3D-VLE (three-dimensional nonlinear viscoelastic theory) three-parameters viscoelastic model for studying the time-dependent behaviour of concrete filled steel tube (CFT) columns. Th... This paper proposes a based on 3D-VLE (three-dimensional nonlinear viscoelastic theory) three-parameters viscoelastic model for studying the time-dependent behaviour of concrete filled steel tube (CFT) columns. The method of 3D-VLE was developed to analyze the effects of concrete creep behavior on CFT structures. After the evaluation of the parameters in the proposed creep model, experimental measurements of two prestressed reinforced concrete beams were used to investigate the creep phenomenon of three CFT columns under long-term axial and eccentric load was investigated. The experimentally obtained time-dependent creep behaviour accorded well with the cu~'es obtained from the proposed method. Many factors (such as ratio of long-term load to strength, slenderness ratio, steel ratio, and eccentricity ratio) were considered to obtain the regularity of influence of concrete creep on CFT structures. The analytical results can be consulted in the engineering practice and design. 展开更多
关键词 Three-dimensional virtual laminated element (3D-VLE) Creep analysis Three-dimensional viscoelastic theory Three-parameters viscoelastic model concrete filled steel tube columns
下载PDF
Performance Investigation of Square Concrete-filled Steel Tube Columns
10
作者 陈兵 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2011年第4期730-736,共7页
The behaviour of square concrete-filled steel tube columns under concentrical loading was studied. More than one hundred specimens were tested to investigate the effects of thickness of steel tube on the load carrying... The behaviour of square concrete-filled steel tube columns under concentrical loading was studied. More than one hundred specimens were tested to investigate the effects of thickness of steel tube on the load carrying capacity of the concrete-filled tubular columns (CFTs). The effect of the grade of concrete and content of expansive agent were also investigated. The effect of these parameters on the confinement of the concrete core was studied as well. From the experimental study it was found that for both CFTs with different strength grade concrete core, the ultimate load carrying capacity increases with the increase in percentage of expansive agent up to 20% but it again decreases at 25% of expansive agent content. It was also shown that the failure mode of CFTs depends on the strength grade of concrete core. 展开更多
关键词 concrete filled steel tubes concrete columnS ultimate capacity expansive agent
下载PDF
Experimental investigation of seismic performance of concrete-filled glass fiber reinforced polymer tubular columns
11
作者 关宏波 王清湘 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2011年第5期37-43,共7页
A reinforced concrete (RC) column and four concrete filled GFRP tubular columns,which are subjected to combined axial compression and lateral cycle loading,were tested in order to investigate the seismic performance o... A reinforced concrete (RC) column and four concrete filled GFRP tubular columns,which are subjected to combined axial compression and lateral cycle loading,were tested in order to investigate the seismic performance of composite construction concrete filled glass fiber reinforced polymer (GFRP) tubular (CFFT) columns.The results indicated that concrete-filled GFRP tubular columns exhibit considerable influence over the seismic performance of columns by providing hoop confinement to the core concrete.The concrete filled GFRP tubular columns exhibit significant improvement over traditional RC columns in both ultimate strength and ductility.Different column-footing connection modes do not affect the strength and ductility of concrete filled GFRP tubular columns.The strength of concrete filled GFRP tubular columns under high axial compression load conditions are slightly increased,however,ductility declined. 展开更多
关键词 concrete columns CONNECTIONS DUCTILITY concrete filled GFRP tubular column SEISMIC
下载PDF
Prediction of Axial Capacity of Concrete-Filled Square Steel Tubes Using Neural Networks
12
作者 朱美春 王清湘 冯秀峰 《Journal of Southwest Jiaotong University(English Edition)》 2005年第2期151-155,共5页
The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concret... The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concrete compressive strength, yield strength of steel tube, confinement index, sectional dimension and width-to-thickness ratio. The ultimate bearing capacity is the only output parameter. A multilayer feedforward neural network is used to describe the nonlinear relationships between the input and output variables. Fifty-five experimental data of CFST short columns under axial loading are used to train and test the neural network. A comparison between the neural network model and three parameter models shows that the neural network model possesses good accuracy and could be a practical method for predicting the ultimate strength of axially loaded CFST short columns. 展开更多
关键词 concrete-filled square steel tubes Neural networks Axial capacity Short columns
下载PDF
Analysis and seismic tests of composite shear walls with CFST columns and steel plate deep beams 被引量:1
13
作者 Dong Hongying Cao Wanlin +2 位作者 Wu Haipeng Zhang Jianwei Xu Fangfang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第4期609-624,共16页
A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipat... A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements - the CFST columns and SP deep beams - to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures. 展开更多
关键词 concrete filled steel tube (CFST) column steel plate (SP) deep beam composite shear wall seismic test calculation and analysis
下载PDF
高强钢筋增强UHPC-CFST组合桥墩抗震性能研究
14
作者 郑仁亮 庄一舟 +1 位作者 张仁巍 曾武华 《浙江工业大学学报》 北大核心 2025年第1期40-51,共12页
采用有限元软件ABAQUS,开展了高强钢筋增强UHPC-CFST组合桥墩的抗震数值建模分析,通过与已有试验结果的对比,验证了建模方法的准确性。在此基础上,分析了轴压比、UHPC强度、UHPC厚度和钢管屈服强度等参数对组合桥墩受力性能的影响规律,... 采用有限元软件ABAQUS,开展了高强钢筋增强UHPC-CFST组合桥墩的抗震数值建模分析,通过与已有试验结果的对比,验证了建模方法的准确性。在此基础上,分析了轴压比、UHPC强度、UHPC厚度和钢管屈服强度等参数对组合桥墩受力性能的影响规律,并给出了各参数的建议取值范围。研究结果表明:增大轴压比和纵筋配筋率可提升组合桥墩的水平承载力和耗能能力,然而会限制试件的变形;提高UHPC强度和UHPC厚度,组合桥墩的水平承载力和位移延性系数均呈现出先增大后减小的趋势;提升钢管屈服强度可稳步增强组合桥墩的水平承载力;增加钢管厚度可明显提升组合桥墩的抗震性能,而体积配箍率和混凝土强度对组合桥墩的抗震性能影响较小。基于分析数据样本,采用多元非线性回归分析得到水平峰值荷载和位移延性系数的计算方法,公式计算值与有限元分析值吻合良好。 展开更多
关键词 高强钢筋 超高性能混凝土 钢管混凝土柱 有限元 计算方法
下载PDF
方钢管混凝土柱穿入式组合节点耗能机制
15
作者 徐庆元 雷建雄 +4 位作者 丁发兴 周期石 张华帅 邱远光 杨建军 《工程力学》 北大核心 2025年第1期116-128,共13页
开展了4个翼缘削弱的钢管混凝土柱穿入式组合节点抗震性能与三维实体有限元精细化模型分析。在混凝土三轴塑性损伤和钢材混合强化模型基础上,进一步引入钢材的韧性损伤模型,探讨了钢梁削弱程度对节点抗震性能与破坏形式的影响规律,结果... 开展了4个翼缘削弱的钢管混凝土柱穿入式组合节点抗震性能与三维实体有限元精细化模型分析。在混凝土三轴塑性损伤和钢材混合强化模型基础上,进一步引入钢材的韧性损伤模型,探讨了钢梁削弱程度对节点抗震性能与破坏形式的影响规律,结果显示引入钢材韧性损伤的有限元模型分析结果与试验结果更加吻合,且钢梁削弱程度降低了该节点的刚度、承载力和耗能。随后对不同钢梁尺寸和柱端拉筋强构造下的组合节点进行了承载力、刚度和塑性耗能分配与失效机制的影响规律分析,分析结果表明:穿入式节点分别在梁-柱抗弯承载力比介于1.66~2.11、梁-柱线刚度比介于1.90~1.96、梁-柱截面刚度比介于1.16~1.21时,将由梁耗能向柱耗能转变;柱端拉筋强构造技术后,由于拉筋直接约束混凝土,大幅度提升了柱端抗弯承载力和耗能能力,组合节点在高轴压比时仍维持梁端失效破坏模式;根据《建筑抗震设计规范》,梁-柱抗弯承载力比取值小于1时为强柱弱梁,这对穿入式组合节点强柱弱梁的定义较为保守。 展开更多
关键词 方钢管混凝土柱 钢-混凝土组合梁 穿入式组合节点 韧性损伤 塑性耗能
下载PDF
L形冷弯薄壁型钢组合钢管混凝土柱轴压性能
16
作者 吴丽丽 刘艳霞 +1 位作者 武海鹏 韩港豪 《哈尔滨工业大学学报》 EI CAS 北大核心 2025年第1期77-91,共15页
为解决异形钢管混凝土柱阴角对其承载力的影响,提出了用1个冷弯薄壁方钢管和2个U形钢管焊接成L形钢管,内填充混凝土形成L形冷弯薄壁型钢组合钢管混凝土柱形式。设计了5组共10根试件的轴压试验,并开展了有限元参数分析,研究了钢管厚度、... 为解决异形钢管混凝土柱阴角对其承载力的影响,提出了用1个冷弯薄壁方钢管和2个U形钢管焊接成L形钢管,内填充混凝土形成L形冷弯薄壁型钢组合钢管混凝土柱形式。设计了5组共10根试件的轴压试验,并开展了有限元参数分析,研究了钢管厚度、U形管外伸长度和钢材强度等参数对构件承载力和延性等力学性能的影响。结果表明:该类试件的主要破坏形态为中上部局部鼓曲破坏,适量增大U形管外伸长度可以提高承载力,但增大到一定程度之后易发生弯扭破坏;承载力和延性随着钢管厚度和钢材强度增大而增加;混凝土强度对构件的初始刚度和峰值荷载的影响都很小,但对曲线下降段的影响较大;试件端部和中部截面阴角处的混凝土应力值比各边中部更大,说明采用U形钢管与方钢管组合的方式改善了阴角处钢管对混凝土约束普遍较弱的问题。基于“统一理论”,给出了两种承载力建议计算公式,与试验结果吻合较好,两种计算方法在0.44~1.94的约束效应系数范围内具有良好的适用性。 展开更多
关键词 L形 U形管 钢管混凝土柱 轴心受压 承载力
下载PDF
往复荷载作用后钢管混凝土柱-组合梁节点耐火性能数值分析
17
作者 王文达 李生强 +1 位作者 毛文婧 郑龙 《建筑科学与工程学报》 北大核心 2025年第1期1-13,共13页
为研究钢管混凝土柱-组合梁节点在往复荷载作用后的耐火性能,利用有限元软件ABAQUS建立了该节点的有限元分析模型,并与已有试验结果进行对比验证。在此基础上,分析了往复荷载作用后塑性损伤和残余变形对组合梁节点火灾下的应力和变形的... 为研究钢管混凝土柱-组合梁节点在往复荷载作用后的耐火性能,利用有限元软件ABAQUS建立了该节点的有限元分析模型,并与已有试验结果进行对比验证。在此基础上,分析了往复荷载作用后塑性损伤和残余变形对组合梁节点火灾下的应力和变形的影响,以及不同损伤程度、荷载作用水平和防火保护层厚度对节点耐火极限和破坏模态的影响。结果表明:地震预损伤对节点的耐火极限有不利影响,且随损伤程度的增加,耐火极限下降明显;重度损伤下节点的耐火极限与无损伤节点相比降低了23.5%;重度损伤的节点在火灾作用下形成塑性铰,且产生较大的耗能损伤,轻度和中度损伤下未形成明显塑性铰,耐火极限分别仅下降1.0%和3.6%;对于以梁损伤作为预损伤模式的节点,梁荷载比和防火保护层厚度是影响有地震预损伤节点耐火极限的主要因素;随柱荷载比的增大,耐火极限呈降低趋势,但整体影响不大。 展开更多
关键词 钢管混凝土柱-组合梁节点 低周往复加载 损伤程度 耐火极限
下载PDF
Behaviors of recycled aggregate concrete-filled steel tubular columns under eccentric loadings 被引量:1
18
作者 Vivian W.Y.TAM Jianzhuang XIAO +1 位作者 Sheng LIU Zixuan CHEN 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2019年第3期628-639,共12页
The paper investigates the behaviors of recycled aggregate concrete-filled steel tubular(RACFST)columns under eccentric loadings with the incorporation of expansive agents.A total of 16 RACFST columns were tested in t... The paper investigates the behaviors of recycled aggregate concrete-filled steel tubular(RACFST)columns under eccentric loadings with the incorporation of expansive agents.A total of 16 RACFST columns were tested in this study.The main parameters varied in this study are recycled coarse aggregate replacement percentages(0%,30%,50%,70%,and 100%),expansive agent dosages(0%,8%,and 15%)and an eccentric distance of compressive load from the center of the column(0 and 40 mm).Experimental results showed that the ultimate stresses of RACFST columns decreased with increasing recycled coarse aggregate replacement percentages but appropriate expansive agent dosages can reduce the decrement;the incorporation of expansive agent decreased the ultimate stresses of RACFST columns but an appropriate dosage can increase the deformation ability.The recycled coarse aggregate replacement percentages have limited influence on the ultimate stresses of the RACFST columns and has more effect than that of the normal aggregate concretesteel tubular columns. 展开更多
关键词 concrete filled steel TUBES recycled AGGREGATE concrete columnS expansive agent ECCENTRIC load
原文传递
Cyclic behavior of stiffened joints between concrete-filled steel tubular column and steel beam with narrow outer diaphragm and partial joint penetration welds 被引量:5
19
作者 Chunyan QUAN Wei WANG +1 位作者 Jian ZHOU Rong WANG 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2016年第3期333-344,共12页
This paper presented an investigation on a stiffened joint in practical engineering which was between concrete-filled steel tubular column and steel beam with narrow outer diaphragm and partial joint penetration welds... This paper presented an investigation on a stiffened joint in practical engineering which was between concrete-filled steel tubular column and steel beam with narrow outer diaphragm and partial joint penetration welds. Through the low-frequency cyclic loading test, the cyclic behavior and failure mode of the specimen were investigated. The results of the test indicated the failure mode and bearing capacity of the specimen which were influenced by the axial compression ratio of the concrete-filled tubular column. On the contrary, the inner diaphragm and inner stiffeners had limited impacts on the hysteretic behavior of the joint. There was no hysteresis damage fracture on the narrow outer diaphragm connected to the concrete-filled steel tubular column with partial joint penetration welds. Due to the excellent ductility and energy dissipating capacity, the proposed joint could be applied to the seismic design of high-rise buildings in highly intensive seismic region, but axial compression ratio should be controlled to avoid unfavorable failure modes. 展开更多
关键词 narrow outer diaphragm concrete-filled tubular column JOINT inner and outer stiffening cyclic behavior
原文传递
Stress-strain relationship of recycled self-compacting concrete filled steel tubular column subjected to eccentric compression
20
作者 Feng YU Cheng QIN +2 位作者 Shilong WANG Junjie JIANG Yuan FANG 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2020年第3期760-772,共13页
As a typical compression member,the concrete-filled steel tube has been widely used in civil engineering structures.However,little research on recycled self-compacting concrete flled circular steel tubular(RSCCFCST)co... As a typical compression member,the concrete-filled steel tube has been widely used in civil engineering structures.However,little research on recycled self-compacting concrete flled circular steel tubular(RSCCFCST)columns subjected to eccentric load was reported.In this study,21 specimens were designed and experimental studies on the stress-strain relationship of were carried out to study the mechanical behaviors.Recycled coarse aggregate replacement ratio,concrete strength grade,length to diameter ratio and eccentric distance of specimens were considered as the main experimental parameters to carry out eccentric compression tests.The corresponding stress-strain relationship curves were used to analyze the influence of concerned parameters on ecentric load-bearing capacity of RSCCFCST columns.The experimental results show that the strain of the eccentric compression stress-strain curves increase with the increase of recycled coarse aggregate replacement ratio and concrete strength grade.With increase of eccentric distance,the ductility of specimens increases while the bearing capacity decreases.Moreover,a phenomenological model of RSCCFCST columns is proposed,which exhibits versatile ability to capture the process during loading.The present study is expected to further understanding the behaviors and to provide guidance of RSCCFCST columns in design and engineering applications. 展开更多
关键词 concrete flleld circular steel tubular columns recycled self-compacting concrete eccentric compression recycled coarse aggregate replacement ratio stress-strain relationship
原文传递
上一页 1 2 164 下一页 到第
使用帮助 返回顶部