An extensive experimental and theoretical research study was undertaken to study the vibration serviceability of a long-span prestressed concrete floor system to be used in the lounge of a major airport.Specifically,j...An extensive experimental and theoretical research study was undertaken to study the vibration serviceability of a long-span prestressed concrete floor system to be used in the lounge of a major airport.Specifically,jumping impact tests were carried out to obtain the floor’s modal parameters,followed by an analysis of the distribution of peak accelerations.Running tests were also performed to capture the acceleration responses.The prestressed concrete floor was found to have a low fundamental natural frequency(≈8.86 Hz)corresponding to the average modal damping ratio of≈2.17%.A coefficients plate with simply-supported edges.The calculated analytical results(natural frequencies and root-mean-square acceleration)agree well with the experimental ones.The analytical approach is thus validated.展开更多
This paper experimentally investigates the namely, normal density concrete and structural low-density energy absorption potential of two types of concrete floors, concrete, containing secondary (shrinkage and tempera...This paper experimentally investigates the namely, normal density concrete and structural low-density energy absorption potential of two types of concrete floors, concrete, containing secondary (shrinkage and temperature) reinforcements. The test program considered the following secondary reinforcements: 1) traditional welded-wire steel mesh, 2) steel fiber and 3) poly composite fiber. To estimate the extent to which crushing of floor slab materials would help absorb energy, a series of concrete penetration tests employing patch loading was undertaken on scaled down model slabs. Each concrete-secondary reinforcement combination considered slabs of 50 mm in depth with square plan dimensions ranging from 50 to 500 mm, resulting in a total of 30 test specimens. The first part of the paper discusses the test specimens, the test setup, and the test procedure. The second part of the paper presents the experimental results and establishes the energy absorption of different concrete- secondary reinforcement combinations. Sieve analysis results of the crushed specimens were used to derive a "work index" value that relates the pulverized particle size distributions to energy inputs. The work index values of concrete-secondary reinforcement systems can be used to assess the energy dissipation potential associated with such floor slabs in buildings undergoing progressive collapse. The results indicate that floors with secondary reinforcements could play an important role in helping arrest global progressive collapse.展开更多
Stiffening-ribbed-hollow-pipe cast-in place reinforced concrete girderless floor is a new-style hollow girderless floor system. Model experimental researches of simply-supported floor and four-corners bearing floor ha...Stiffening-ribbed-hollow-pipe cast-in place reinforced concrete girderless floor is a new-style hollow girderless floor system. Model experimental researches of simply-supported floor and four-corners bearing floor have been done on this new kind of floor system in this paper. The experiment results show that the floor system has good mechanical property such as high bearing capacity, big rigidity and good tensility. A theoretical method is presented in this paper that the stiffening-ribbed-hollow-pipe girderless floor can be analyzed by being converted equivalently to orthotropic solid slab. It is indicated that the method is correct and reasonable according to the contrast between theoretical calculated results and experimental measured results. The theoretical results coincide with the measured results well.展开更多
基金National Natural Science Foundation of China under Grant No.51438001Fundamental Research Funds for the Central Universities under Grant Nos.106112014CDJZR200001 and 106112015CDJXZ208804+1 种基金Chongqing basic and frontier research project under Grant No.cstc2014jcyjys30001National key research and development program of China under Grant No.2016YFC0701201
文摘An extensive experimental and theoretical research study was undertaken to study the vibration serviceability of a long-span prestressed concrete floor system to be used in the lounge of a major airport.Specifically,jumping impact tests were carried out to obtain the floor’s modal parameters,followed by an analysis of the distribution of peak accelerations.Running tests were also performed to capture the acceleration responses.The prestressed concrete floor was found to have a low fundamental natural frequency(≈8.86 Hz)corresponding to the average modal damping ratio of≈2.17%.A coefficients plate with simply-supported edges.The calculated analytical results(natural frequencies and root-mean-square acceleration)agree well with the experimental ones.The analytical approach is thus validated.
文摘This paper experimentally investigates the namely, normal density concrete and structural low-density energy absorption potential of two types of concrete floors, concrete, containing secondary (shrinkage and temperature) reinforcements. The test program considered the following secondary reinforcements: 1) traditional welded-wire steel mesh, 2) steel fiber and 3) poly composite fiber. To estimate the extent to which crushing of floor slab materials would help absorb energy, a series of concrete penetration tests employing patch loading was undertaken on scaled down model slabs. Each concrete-secondary reinforcement combination considered slabs of 50 mm in depth with square plan dimensions ranging from 50 to 500 mm, resulting in a total of 30 test specimens. The first part of the paper discusses the test specimens, the test setup, and the test procedure. The second part of the paper presents the experimental results and establishes the energy absorption of different concrete- secondary reinforcement combinations. Sieve analysis results of the crushed specimens were used to derive a "work index" value that relates the pulverized particle size distributions to energy inputs. The work index values of concrete-secondary reinforcement systems can be used to assess the energy dissipation potential associated with such floor slabs in buildings undergoing progressive collapse. The results indicate that floors with secondary reinforcements could play an important role in helping arrest global progressive collapse.
文摘Stiffening-ribbed-hollow-pipe cast-in place reinforced concrete girderless floor is a new-style hollow girderless floor system. Model experimental researches of simply-supported floor and four-corners bearing floor have been done on this new kind of floor system in this paper. The experiment results show that the floor system has good mechanical property such as high bearing capacity, big rigidity and good tensility. A theoretical method is presented in this paper that the stiffening-ribbed-hollow-pipe girderless floor can be analyzed by being converted equivalently to orthotropic solid slab. It is indicated that the method is correct and reasonable according to the contrast between theoretical calculated results and experimental measured results. The theoretical results coincide with the measured results well.