期刊文献+
共找到2,351篇文章
< 1 2 118 >
每页显示 20 50 100
Self-centering seismic retrofit scheme for reinforced concrete frame structures:SDOF system study 被引量:5
1
作者 Yunfeng Zhang and Xiaobin Hu Department of Civil and Environmental Engineering,University of Maryland,College Park,MD 20742,USA 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2010年第2期271-283,共13页
This paper presents the results of a parametric study of self-centering seismic retrofit schemes for reinforced concrete (RC) frame buildings. The self-centering retrofit system features flag-shaped hysteresis and min... This paper presents the results of a parametric study of self-centering seismic retrofit schemes for reinforced concrete (RC) frame buildings. The self-centering retrofit system features flag-shaped hysteresis and minimal residual deformation. For comparison purpose,an alternate seismic retrofit scheme that uses a bilinear-hysteresis retrofit system such as buckling-restrained braces (BRB) is also considered in this paper. The parametric study was carried out in a single-degree-of-freedom (SDOF) system framework since a multi-story building structure may be idealized as an equivalent SDOF system and investigation of the performance of this equivalent SDOF system can provide insight into the seismic response of the multi-story building. A peak-oriented hysteresis model which can consider the strength and stiffness degradation is used to describe the hysteretic behavior of RC structures. The parametric study involves two key parameters -the strength ratio and elastic stiffness ratio between the seismic retrofit system and the original RC frame. An ensemble of 172 earthquake ground motion records scaled to the design basis earthquake in California with a probability of exceedance of 10% in 50 years was constructed for the simulation-based parametric study. The effectiveness of the two seismic retrofit schemes considered in this study is evaluated in terms of peak displacement ratio,peak acceleration ratio,energy dissipation demand ratio and residual displacement ratio between the SDOF systems with and without retrofit. It is found from this parametric study that RC structures retrofitted with the self-centering retrofit scheme (SCRS) can achieve a seismic performance level comparable to the bilinear-hysteresis retrofit scheme (BHRS) in terms of peak displacement and energy dissipation demand ratio while having negligible residual displacement after earthquake. 展开更多
关键词 EARTHQUAKE reinforced concrete frame structure nonlinear analysis SDOF system seismic retrofit SELF-CENTERING
下载PDF
Mechanical behaviour analysis and support system field experiment of confined concrete arches 被引量:5
2
作者 WANG Qi LUAN Ying-cheng +2 位作者 JIANG Bei LI Shu-cai YU Heng-chang 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第4期970-983,共14页
Soft rock control is a big challenge in underground engineering.As for this problem,a high-strength support technique of confined concrete(CC)arches is proposed and studied in this paper.Based on full-scale mechanical... Soft rock control is a big challenge in underground engineering.As for this problem,a high-strength support technique of confined concrete(CC)arches is proposed and studied in this paper.Based on full-scale mechanical test system of arch,research is made on the failure mechanism and mechanical properties of CC arch.Then,a mechanical calculation model of circular section is established for the arches with arbitrary section and unequal rigidity;a calculation formula is deduced for the internal force of the arch;an analysis is made on the influence of different factors on the internal force of the arch;and a calculation formula is got for the bearing capacity of CC arch through the strength criterion of bearing capacity.With numerical calculation and laboratory experiment,the ultimate bearing capacity and internal force distribution is analyzed for CC arches.The research results show that:1)CC arch is 2.31 times higher in strength than the U-shaped steel arch and has better stability;2)The key damage position of the arch is the two sides;3)Theoretical analysis,numerical calculation and laboratory experiment have good consistency in the internal force distribution,bearing capacity,and deformation and failure modes of the arch.All of that verifies the correctness of the theoretical calculation.Based on the above results,a field experiment is carried out in Liangjia Mine.Compared with the U-shaped steel arch support,CC arch support is more effective in surrounding rock deformation control.The research results can provide a basis for the design of CC arch support in underground engineering. 展开更多
关键词 confined concrete arch full-scale laboratory experiment theoretical analysis numerical experiment field application
下载PDF
Ion-transport characteristics of new-old concrete composite system 被引量:4
3
作者 龙广成 谢友均 +1 位作者 丁巍巍 Ahmed OMRAN 《Journal of Central South University》 SCIE EI CAS 2014年第2期790-798,共9页
New-old concrete composite system usually exists in concrete repairing structure.In the present work,series of experiments were carried out to investigate permeability and ion diffusion properties of new-old concrete ... New-old concrete composite system usually exists in concrete repairing structure.In the present work,series of experiments were carried out to investigate permeability and ion diffusion properties of new-old concrete composite by measuring 6-hour coulomb charge and chloride diffusivity.The interrelation among transport properties of new-old composites,new,and old concretes was also discussed.Results indicate that the permeability and chloride diffusivity of new-old concrete composite system closely interrelate to the corresponding new concrete and old concrete.The interfacial transition zone between new concrete and old concrete greatly influences the transport property of new-old concrete system.Compared with the corresponding new concrete and old concrete lower permeability and diffusivity values for the new-old concrete composites can be achieved by choosing suitable new concrete.It is possible to design the tailor-made new-old concrete composite system for repair given the transport property. 展开更多
关键词 new-old concrete composite chloride diffusivity PERMEABILITY transport property
下载PDF
Corrosion risk assessment of chloride-contaminated concrete structures using embeddable multi-cell sensor system 被引量:2
4
作者 卢爽 巴恒静 《Journal of Central South University》 SCIE EI CAS 2011年第1期230-237,共8页
Monitoring the service condition of concrete structures requires the quantitative assessment of properties and corrosion rate of structural steels surrounded by concrete.A multi-cell sensor system that included a refe... Monitoring the service condition of concrete structures requires the quantitative assessment of properties and corrosion rate of structural steels surrounded by concrete.A multi-cell sensor system that included a reference electrode,a chloride content sensor,a macrocell current unit and an electrical resistance measurement unit was developed.This system provided the following important electrochemical data in the cover-zone concrete on site:open circuit potential,macrocell current from anodes to cathode,chloride profile,concrete resistance and corrosion rate of built-in anodes.The experimental results show that the macrocell current increases when the chloride content in concrete is higher.Thus,monitoring the chloride content is a good method for monitoring the corrosion state.The chloride ion content and cover depth are the key factors that affect the electrical resistance of concrete.Without considering the temperature and time,a simplified model of the instantaneous corrosion rate of steel rebar in a concrete structure based on the measured chloride contents and concrete resistance was proposed.The test results further prove the reliability of this simplified predicting model. 展开更多
关键词 concrete structures corrosion rate RESISTANCE chloride content macrocell current multi-cell sensor
下载PDF
Methodology for estimating probability of dynamical system's failure for concrete gravity dam 被引量:2
5
作者 王超 张社荣 +1 位作者 孙博 王高辉 《Journal of Central South University》 SCIE EI CAS 2014年第2期775-789,共15页
Methodology for the reliability analysis of hydraulic gravity dam is the key technology in current hydropower construction.Reliability analysis for the dynamical dam safety should be divided into two phases:failure mo... Methodology for the reliability analysis of hydraulic gravity dam is the key technology in current hydropower construction.Reliability analysis for the dynamical dam safety should be divided into two phases:failure mode identification and the calculation of the failure probability.Both of them are studied based on the mathematical statistics and structure reliability theory considering two kinds of uncertainty characters(earthquake variability and material randomness).Firstly,failure mode identification method is established based on the dynamical limit state system and verified through example of Koyna Dam so that the statistical law of progressive failure process in dam body are revealed; Secondly,for the calculation of the failure probability,mathematical model and formula are established according to the characteristics of gravity dam,which include three levels,that is element failure,path failure and system failure.A case study is presented to show the practical application of theoretical method and results of these methods. 展开更多
关键词 concrete gravity dam dynamical system failure mode identification calculation of system failure probability stochastic model
下载PDF
Simplified full-depth precast concrete deck panel systems for accelerated bridge construction 被引量:4
6
作者 Zhongguo John Ma Yulin Zhan +2 位作者 Lin Xiao Lungui Li Weiwei Lu 《Journal of Modern Transportation》 2016年第4期251-260,共10页
A simplified full-depth precast concrete deck panel system for accelerating bridge construction (ABC) is introduced and a finite dement analysis (FEA) is con- ducted to investigate the static and dynamic responses... A simplified full-depth precast concrete deck panel system for accelerating bridge construction (ABC) is introduced and a finite dement analysis (FEA) is con- ducted to investigate the static and dynamic responses of this conceptual deck system. The FEA results are compared to those of the traditional full-depth precast concrete deck panel system. The comparison results show that the mechanical behavior of the new deck system is different from that of the traditional deck system. The concrete decks in the new system act as two-way slabs, instead of the one-way slab in the traditional system. Meanwhile, the connections in both the longitudinal and transverse direc- tions may need to accommodate the negative moments. Compared to those in the traditional system, the longitu- dinal nominal stress at middle span increases a lot in the new deck system and the effective flange width varies significantly. In addition, the dynamic results show that the impact factor is influenced by the spacing of connections. Finally, some design concerns of the new deck system are proposed. 展开更多
关键词 Simplified full-depth precast concrete deckpanel systems ~ Accelerated bridge construction ~ Structuralresponse
下载PDF
An expert system for diagnosing fire-caused damages to reinforced-concrete tunnel lining 被引量:1
7
作者 MANSOOR Yousif A. ZHANG Zhi-qiang 《Journal of Chongqing University》 CAS 2013年第1期16-26,共11页
During the last four decades, reinforced-concrete structure failures have been happening widely for many reasons, such as increased service loads, war accidents, fire, and durability problems. The economic losses due ... During the last four decades, reinforced-concrete structure failures have been happening widely for many reasons, such as increased service loads, war accidents, fire, and durability problems. The economic losses due to those failures are very high. An expert system is an interactive computer-based decision tool that uses both facts and heuristics to solve difficult problems based on knowledge acquired from experts. To realize these requirements, a logic programming visual basic language is used together with visual diagnosis. The expert system, Diagnosis of Fire-Caused Damages to Reinforced-Concrete Tunnel Lining (DFCDRCTL) was developed in this work for diagnosing the annual damages caused by fire. The program is used as an alternative of a human expert to make annual technical decisions in diagnosing fire damages at the second reinforced-concrete tunnel lining segment. It is concluded that the proposed DFCDRCTL expert system is easy to use, and is fast and helpful for engineers. 展开更多
关键词 expert system fire damage of reinforced concrete tunnel lining damage
下载PDF
Preparation of New Cementitious System using Fly Ash and Dehydrated Autoclaved Aerated Concrete 被引量:3
8
作者 水中和 LU Jianxin +2 位作者 TIAN Sufang SHEN Peiliang DING Sha 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2014年第4期726-732,共7页
We experimentally studied the interaction between pozzolanic material(fly ash) and dehydrated autoclaved aerated concrete(DAAC). The DAAC powder was obtained by grinding aerated concrete waste to particles fi ner ... We experimentally studied the interaction between pozzolanic material(fly ash) and dehydrated autoclaved aerated concrete(DAAC). The DAAC powder was obtained by grinding aerated concrete waste to particles fi ner than 75μm and was then heated to temperatures up to 900 ℃. New cementitious material was prepared by proportioning fly ash and DAAC, named as AF. X-ray diffraction(XRD) was employed to identify the crystalline phases of DAAC before and after rehydration. The hydration process of AF was analyzed by the heat of hydration and non-evaporable water content(Wn). The experimental results show that the highest reactivity of DAAC can be obtained by calcining the powder at 700 ℃ and the dehydrated products are mainly β-C2 S and CaO. The cumulative heat of hydration and Wn was found to be strongly dependent on the replacement level of fl y ash, increasing the replacement level of fl y ash lowered them in AF. The strength contribution rates on pozzolanic effect of fl y ash in AF are always negative, showing a contrary tendency of that of cement-fl y ash system. 展开更多
关键词 dehydrated autoclaved aerated concrete pozzolanic reaction heat of hydration nonevaporable water content strength contribution rate
下载PDF
ENERGY-SAVING MATCHING STRATEGY AND EXPERIMENTAL STUDY OF PUMPING SYSTEM FOR TRUCK-MOUNTED CONCRETE PUMP 被引量:1
9
作者 李艾民 陈飞 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2013年第1期104-108,共5页
Aiming at the high fuel consumption and use-cost of truck-mounted concrete pump , an energy-saving matching strategy of pumping system is presented and the experimental study is conducted.Since pumping system occupies... Aiming at the high fuel consumption and use-cost of truck-mounted concrete pump , an energy-saving matching strategy of pumping system is presented and the experimental study is conducted.Since pumping system occupies most resources of engine , the matching strategy between engine and main pump is analyzed to meet the load demand and reduce the engine rational speed drop.The testing method is established to measure the fuel consumption of engine under various working conditions , and the experimental data are analyzed to find the law of the fuel consumption of engine.The system performance can be improved by adjusting the system input value.Finally , the energy-saving matching strategy is established to reduce the fuel consumption of truck for unit workload , which provides a new approach for the energy-saving of truck-mounted concrete pump. 展开更多
关键词 truck-mounted concrete pump pumping systeml energy saving speed drop of engine
下载PDF
Development of Optimal Structural System for Hybrid Cable-Stayed Bridges Using Ultra High Performance Concrete 被引量:1
10
作者 Hee Seok Kim Young Jin Kim +1 位作者 Won Jong Chin Hyejin Yoon 《Engineering(科研)》 2013年第9期720-728,共9页
This study developed an optimal structural system for the hybrid cable-stayed bridge expected to have a durable lifetime of 200 years and of which major structural members are made of ultra high performance concrete (... This study developed an optimal structural system for the hybrid cable-stayed bridge expected to have a durable lifetime of 200 years and of which major structural members are made of ultra high performance concrete (UHPC) with 200 MPa-class compressive strength. This innovative cable-stayed bridge system makes it possible to reduce each of the construction and maintenance costs by 20% compared to the conventional concrete cable-stayed bridge by improving significantly the weight and durability of the bridge. Therefore, detail design is carried out considering a real 800 m cable-stayed bridge and the optimal structure of the hybrid cable-stayed bridge is proposed and verified. 展开更多
关键词 HYBRID CABLE-STAYED Bridge Ultra High Performance concrete (UHPC) OPTIMAL Structural system DURABILITY
下载PDF
Intelligent Small Sample Defect Detection of Concrete Surface Using Novel Deep Learning Integrating Improved YOLOv5 被引量:2
11
作者 Yongming Han Lei Wang +1 位作者 Youqing Wang Zhiqiang Geng 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2024年第2期545-547,共3页
Dear Editor,This letter presents an intelligent small sample defect detection of concrete surface using novel deep learning integrating the improved YOLOv5 based on the Wasserstein GAN(WGAN)enhancement algorithm.The p... Dear Editor,This letter presents an intelligent small sample defect detection of concrete surface using novel deep learning integrating the improved YOLOv5 based on the Wasserstein GAN(WGAN)enhancement algorithm.The proposed method is capable of producing top-notch data sets to address the issues of insufficient samples and substandard quality. 展开更多
关键词 concrete integrating ALGORITHM
下载PDF
Utilization of Basalt Saw Mud as a Spherical Porous Functional Aggregate for the Preparation of Ordinary Structure Concrete 被引量:1
12
作者 周永祥 关青锋 +2 位作者 LENG Faguang WANG Jing LI Tianjun 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS CSCD 2024年第2期364-375,共12页
To promote the production and application of artificial aggregates,save natural sand resources and protect the ecological environment,we evaluated the feasibility of using spherical porous functional aggregates(SPFAs)... To promote the production and application of artificial aggregates,save natural sand resources and protect the ecological environment,we evaluated the feasibility of using spherical porous functional aggregates(SPFAs) formed by basalt saw mud under autoclave curing in ordinary structural concrete.In our work,two types of prewetted functional aggregates were taken as replacements for natural aggregates with different volume substitution rates(0%,5%,10%,15%,20%,25%,and 30%) in the preparation of ordinary structural concrete with water-to-binder ratios(W/B) of 0.48 and 0.33.The effects of the functional aggregate properties and content,W/B,and curing age on the fluidity,density,mechanical properties and autogenous shrinkage of ordinary concrete were analyzed.The experimental results showed that the density of concrete declined at a rate of not more than 5%,and the 28 d compressive strength could reach 31.0-68.2 MPa.Low W/B,long curing age and high-quality functional aggregates were conducive to enhancing the mechanical properties of SPFAs concrete.Through the rolling effects,SPFAs can optimize the particle gradation of aggregate systems and improve the fluidity of concrete,and the water stored inside SPFAs provides an internal curing effect,which prolongs the cement hydration process and considerably reduces the autogenous shrinkage of concrete.SPFAs exhibits high strength and high density,as well as being more cost-effective and ecological,and is expected to be widely employed in ordinary structural concrete. 展开更多
关键词 lightweight concrete civil concrete building basalt saw mud fly ash internal curing environmentally friendly
下载PDF
High-speed penetration of ogive-nose projectiles into thick concrete targets:Tests and a projectile nose evolution model 被引量:1
13
作者 Xu Li Yan Liu +4 位作者 Junbo Yan Zhenqing Shi Hongfu Wang Yingliang Xu Fenglei Huang 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第2期553-571,共19页
The majority of the projectiles used in the hypersonic penetration study are solid flat-nosed cylindrical projectiles with a diameter of less than 20 mm.This study aims to fill the gap in the experimental and analytic... The majority of the projectiles used in the hypersonic penetration study are solid flat-nosed cylindrical projectiles with a diameter of less than 20 mm.This study aims to fill the gap in the experimental and analytical study of the evolution of the nose shape of larger hollow projectiles under hypersonic penetration.In the hypersonic penetration test,eight ogive-nose AerMet100 steel projectiles with a diameter of 40 mm were launched to hit concrete targets with impact velocities that ranged from 1351 to 1877 m/s.Severe erosion of the projectiles was observed during high-speed penetration of heterogeneous targets,and apparent localized mushrooming occurred in the front nose of recovered projectiles.By examining the damage to projectiles,a linear relationship was found between the relative length reduction rate and the initial kinetic energy of projectiles in different penetration tests.Furthermore,microscopic analysis revealed the forming mechanism of the localized mushrooming phenomenon for eroding penetration,i.e.,material spall erosion abrasion mechanism,material flow and redistribution abrasion mechanism and localized radial upsetting deformation mechanism.Finally,a model of highspeed penetration that included erosion was established on the basis of a model of the evolution of the projectile nose that considers radial upsetting;the model was validated by test data from the literature and the present study.Depending upon the impact velocity,v0,the projectile nose may behave as undistorted,radially distorted or hemispherical.Due to the effects of abrasion of the projectile and enhancement of radial upsetting on the duration and amplitude of the secondary rising segment in the pulse shape of projectile deceleration,the predicted DOP had an upper limit. 展开更多
关键词 High-speed penetration concrete target EROSION Projectile nose evolution model
下载PDF
Neuro-fuzzy systems in determining light weight concrete strength
14
作者 Seyed Vahid RAZAVI TOSEE Mehdi NIKOO 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第10期2906-2914,共9页
The adaptive neuro-fuzzy inference systems(ANFIS)are widely used in the concrete technology.In this research,the compressive strength of light weight concrete was determined.To this end,the scoria percentage and curin... The adaptive neuro-fuzzy inference systems(ANFIS)are widely used in the concrete technology.In this research,the compressive strength of light weight concrete was determined.To this end,the scoria percentage and curing day variables were used as the input parameters,and compressive strength and tensile strength were used as the output parameters.In addition,100 patterns were used,70%of which were used for training and 30%were used for testing.To assess the precision of the neuro-fuzzy system,it was compared using two linear regression models.The comparisons were carried out in the training and testing phases.Research results revealed that the neuro-fuzzy systems model offers more potential,flexibility,and precision than the statistical models. 展开更多
关键词 neuro-fuzzy systems compressive strength light weight concrete linear regression model
下载PDF
Fibre Optic Protection System for Concrete Structures
15
作者 J.S.Leng A.Hameed +3 位作者 D.Winter R.A.Barnes G.C.Mays G.F.Fernando 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2006年第3期404-410,共7页
The design concepts, modelling and implementation of various fibre optic sensor protection systems for development in concrete structures were investigated. Design concepts and on-site requirements for surface-mounted... The design concepts, modelling and implementation of various fibre optic sensor protection systems for development in concrete structures were investigated. Design concepts and on-site requirements for surface-mounted and embedded optical fibre sensor in concrete were addressed. Finite element (FE) modelling of selected sensor protection systems in strain-transfer efficiency from the structure to the sensing region was also studied. And experimental validation of specified sensor protection system was reported. Results obtained indicate that the protection system for the sensors performs adequately in concrete environment and there is very good correlation between results obtained by the protected fibre optic sensors and conventional electrical resistance strain gauges. 展开更多
关键词 Fibre optic sensor (FOS) Sensor protection system (SPS) concrete structures Extrinsic Fabry-Perot interferometer (EFPI) sensor Smart Structures Strain transfer
下载PDF
Different Curing Systems on Mechanical Properties of Ultra-High Performance Concrete with Coarse Aggregate
16
作者 赵秋 杨明 +1 位作者 庄一舟 聂宇 《Journal of Donghua University(English Edition)》 EI CAS 2017年第4期492-497,共6页
High durability and high tensile strength makes ultra-high performance concrete( UHPC) an ideal material for bridges,while its early shrinkage in the construction of cast-in-situ mass concrete leads structure crack-ea... High durability and high tensile strength makes ultra-high performance concrete( UHPC) an ideal material for bridges,while its early shrinkage in the construction of cast-in-situ mass concrete leads structure crack-easily,which restricts the application of UHPC in deck system. Whether reasonable amount of coarse aggregate can influence the strength of UHPC and improve the shrinkage performance or reduce the cost is still in doubt. Besides,in order to improve its constructability and workability, whether autoclaved curing system of UHPC can be changed remains to be further researched. In response to these circumstances, a systematic experimental study on the strength of UHPC mixed with coarse aggregate in different ratios has been presented in this paper. The three curing systems,namely standard curing,180-200 ℃/1. 1 MPa autoclaved curing,and hot water curing were tested to reveal the relationship between UHPC's properties and curing systems,and the UHPC ' s microstructure was also preliminarily studied by scanning electron microscope( SEM). The experimental research can draw the following conclusions. Under the condition of the same mix ratio, autoclaved curing guarantees the highest compressive strength,followed by hot water curing and standard curing. The compressive strength of concrete increases with the temperature in the range of 25 to 90 ℃ hot water curing,and high temperature in precuring period can speed up the strength development of UHPC,but the sequence of precuring period does not obviously affect the results. In 90 ℃ hot water and autoclaved curing,the strength is over 150 MPa,and it has little relation with gravel ratio. While the value increases first and then decreases in a lower temperature curing with the increasing of gravel amount,even only about 80 MPa at room temperature. The strength increases moderately along with the increase of the curing age by standard curing,especially in the initial stage. 展开更多
关键词 ultra-high performance concrete(UHPC) coarse aggregate curing system STRENGTH MICROSTRUCTURE
下载PDF
On the treatment of thermal cracks in lining concrete of water conveyance system of Three Gorges Project permanent ship locks
17
作者 王从锋 刘德富 +1 位作者 王东东 段亚辉 《Journal of Coal Science & Engineering(China)》 2008年第1期54-57,共4页
A comprehensive investigation was performed for repairing the different types of cracks appearing on the surface or inside the concrete lining at various depths.The mate- rial properties used in grouting and two metho... A comprehensive investigation was performed for repairing the different types of cracks appearing on the surface or inside the concrete lining at various depths.The mate- rial properties used in grouting and two methods for crack repair were discussed in details, and consequently reliable repair measures were proposed and implemented.It is a better choice to adopt the hole-drilling method for the relatively regular crack.The grouting pres- sure should not be too high and it is generally between 0.4~0.6 MPa.For the second time grouting,the pressure maybe increased to 0.8 MPa.Other method is the pasting nozzles method which is more suitable for irregular cracks such as cracks with intensive density and crossing cracks.Its grouting pressure is generally between 0.6~1.0 MPa.The in-situ tests in Three Gorges Project demonstrate favorably the feasibility and applicability of the proposed methods for crack repair within the lining concrete. 展开更多
关键词 thermal cracks lining concrete Three Gorges Project permanent ship locks
下载PDF
A Critical Examination of the European Standard EN 1504 "Products and Systems for Protection and Repair of Concrete Structures"
18
作者 Cecilia Bartuli Ramen Clgna +1 位作者 Osvaldo Fumei Teodoro Valente 《Journal of Civil Engineering and Architecture》 2012年第2期226-231,共6页
The European Standard EN 1504 "Products and systems for protection and repair of concrete structures -- Definitions, requirements, quality control and evaluation of conformity" can be considered a real milestone for... The European Standard EN 1504 "Products and systems for protection and repair of concrete structures -- Definitions, requirements, quality control and evaluation of conformity" can be considered a real milestone for the companies involved in the rehabilitation of buildings, bridges, piers, pipelines, and other civil or industrial concrete structures. However in some cases the examination and, even more, the practical application of the proposed guidelines are made difficult by a complicated sub-division in principles and methods, and by a confusing and repetitive layout. The paper deals in particular with the principles and methods for the rehabilitation of concrete damage due to reinforcement corrosion, often strictly connected, anyway, to those adopted in order to rehabilitate the concrete itself. Suggestions are given for a possible future update of the Standard, based on the personal experience of the Authors. 展开更多
关键词 concrete repair maintenance PROTECTION European standard sustainability.
下载PDF
Application of the Adaptive Neuro-Fuzzy Inference System for Optimal Design of Reinforced Concrete Beams
19
作者 Jiin-Po Yeh Ren-Pei Yang 《Journal of Intelligent Learning Systems and Applications》 2014年第4期162-175,共14页
Using a genetic algorithm owing to high nonlinearity of constraints, this paper first works on the optimal design of two-span continuous singly reinforced concrete beams. Given conditions are the span, dead and live l... Using a genetic algorithm owing to high nonlinearity of constraints, this paper first works on the optimal design of two-span continuous singly reinforced concrete beams. Given conditions are the span, dead and live loads, compressive strength of concrete and yield strength of steel;design variables are the width and effective depth of the continuous beam and steel ratios for positive and negative moments. The constraints are built based on the ACI Building Code by considering the strength requirements of shear and the maximum positive and negative moments, the development length of flexural reinforcement, and the serviceability requirement of deflection. The objective function is to minimize the total cost of steel and concrete. The optimal data found from the genetic algorithm are divided into three groups: the training set, the checking set and the testing set for the use of the adaptive neuro-fuzzy inference system (ANFIS). The input vector of ANFIS consists of the yield strength of steel, compressive strength of concrete, dead load, span, width and effective depth of the beam;its outputs are the minimum total cost and optimal steel ratios for positive and negative moments. To make ANFIS more efficient, the technique of Subtractive Clustering is applied to group the data to help streamline the fuzzy rules. Numerical results show that the performance of ANFIS is excellent, with correlation coefficients between the three targets and outputs of the testing data being greater than 0.99. 展开更多
关键词 Continuous Reinforced concrete BEAMS GENETIC Algorithm Adaptive NEURO-FUZZY INFERENCE system Correlation COEFFICIENTS
下载PDF
Fractal Study on the Evolution of Micro-Pores in Concrete Under Freeze-Thaw
20
作者 孙浩然 邹春霞 +2 位作者 XU Deru GUO Xiaosong HUANG Kun 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS CSCD 2024年第1期109-117,共9页
After exposure to freeze-thaw cycles, scanning electron microscopy(SEM) and nuclear magnetic resonance(NMR) were used to test the four mixtures. The microstructure is qualitatively analyzed from the 2D SEM image and t... After exposure to freeze-thaw cycles, scanning electron microscopy(SEM) and nuclear magnetic resonance(NMR) were used to test the four mixtures. The microstructure is qualitatively analyzed from the 2D SEM image and the 3D pore distribution curve before and after freezing and thawing. The fractal dimension is utilized to characterize the two-dimensional topography image and the three-dimensional pore distribution, quantitatively. The results reveal that the surface porosity and volume porosity increase as the freeze-thaw action increases. Self-similarity characteristics exist in micro-damage inside the concrete. In the fractal dimension, it is possible to characterize pore evolution quantitatively. The fractal dimension correlates with pore damage evolution. The fractal dimension effectively quantitatively characterizes micro-damage features at various scales from the local to the global level. 展开更多
关键词 fractal dimension freeze-thaw cycle concrete SEM NMR
下载PDF
上一页 1 2 118 下一页 到第