期刊文献+
共找到172篇文章
< 1 2 9 >
每页显示 20 50 100
Experimental investigation of axially loaded steel fiber reinforced high strength concrete-filled steel tube columns 被引量:9
1
作者 卢亦焱 李娜 +1 位作者 李杉 梁鸿骏 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第6期2287-2296,共10页
An experimental study on the compressive behavior of steel fiber reinforced concrete-filled steel tube columns is presented. Specimens were tested to investigate the effects of the concrete strength, the thickness of ... An experimental study on the compressive behavior of steel fiber reinforced concrete-filled steel tube columns is presented. Specimens were tested to investigate the effects of the concrete strength, the thickness of steel tube and the steel fiber volume fraction on the ultimate strength and the ductility. The experimental results indicate that the addition of steel fibers in concrete can significantly improve the ductility and the energy dissipation capacity of the concrete-filled steel tube columns and delay the local buckling of the steel tube, but has no obvious effect on the failure mode. It has also been found that the addition of steel fibers is a more effective method than using thicker steel tube in enhancing the ductility, and more advantageous in the case of higher strength concrete. An analytical model to estimate the load capacity is proposed for steel tube columns filled with both plain concrete and steel fiber reinforced concrete. The predicted results are in good agreement with the experimental ones obtained in this work and literatures. 展开更多
关键词 concrete-filled steel tube (CFST) zolumns steel fiber high strength concrete axial load DUCTILITY load capacity
下载PDF
Seismic performance of recycled concrete-filled square steel tube columns 被引量:9
2
作者 Chen Zongping Jing Chenggui +1 位作者 Xu Jinjun Zhang Xianggang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第1期119-130,共12页
An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic later... An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic lateral loading. Two parameters, replacement percentage of recycled coarse aggregate (RCA) and axial compression level, were considered in the test. Based on the experimental data, the hysteretic loops, skeleton curves, ductility, energy dissipation capacity and stiffness degradation of RCFST columns were analyzed. The test results indicate that the failure modes of RCFST columns are the local buckling of the steel tube at the bottom of the columns, and the hysteretic loops are full and their shapes are similar to normal CFST columns. Furthermore, the ductility coefficient of all specimens are close to 3.0, and the equivalent viscous damping coefficient corresponding to the ultimate lateral load ranges from 0.323 to 0.360, which demonstrates that RCFST columns exhibit remarkable seismic performance. 展开更多
关键词 recycled concrete-filled square steel tube (RCFST) COLUMN replacement percentage cyclic loading seismicperformance
下载PDF
Axial Compression Behavior and Analytical Method of L-Shaped Column Composed of Concrete-Filled Square Steel Tubes 被引量:5
3
作者 荣彬 陈志华 +1 位作者 APOSTOLOS Fafitis 杨楠 《Transactions of Tianjin University》 EI CAS 2012年第3期180-187,共8页
Based on the characteristics of an L-shaped column composed of concrete-filled square steel tubes, the axial compression experiment and nonlinear finite element analysis were carried out to study the mechanical proper... Based on the characteristics of an L-shaped column composed of concrete-filled square steel tubes, the axial compression experiment and nonlinear finite element analysis were carried out to study the mechanical property of the L-shaped column. The load-displacement curve for the L-shaped column, the deflection and load-strain curves for the mono columns were obtained by the axial compression experiment. The results show that the L-shaped column exhibits a flexural-torsional buckling failure mode. The numerical simulation by the finite element analysis shows that the bearing capacity and failure mode are in accordance with those of the axial compression experiment and the feasi- bility of the finite element analysis is proved. For the calculation of the bearing capacity of the L-shaped column com- posed of concrete-filled square steel tubes, an analytical method is proposed based on the theory of the elastic stability and spatial truss model. The results of the analytical method are in good agreement with those of the axial compression experiment and the finite element analysis. 展开更多
关键词 L-shaped column concrete-filled square steel tube axial compression experiment finite element analy-sis analytical method
下载PDF
Effect of contact thermal resistance on temperature distributions of concrete-filled steel tubes in fire 被引量:5
4
作者 吕学涛 杨华 张素梅 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2011年第1期81-88,共8页
To predicate the temperature distribution of concrete-filled steel tubes(CFSTs) being exposure to fire,a finite element analysis model was developed using a finite element package,ANSYS.A suggested value of contact th... To predicate the temperature distribution of concrete-filled steel tubes(CFSTs) being exposure to fire,a finite element analysis model was developed using a finite element package,ANSYS.A suggested value of contact thermal resistance was therefore proposed with the supporting of massive numbers of collected test data.Parametric analysis was conducted subsequently towards the cross-sectional temperature distribution of CFST columns in four-side fire,in which the exposure time,width of the cross section,steel ratio were taken into account with considering contact thermal resistance.It was found that contact thermal resistance has little effect on the overall temperature regulation with the exposure time,the width of cross-section or the change of steel ratio.However,great temperature dropping at the concrete adjacent to the contact interface,and gentle temperature increase at steel tube,exist if considering contact thermal resistance.The results of the study are expected to provide theoretical basis for the fire resistance behavior and design of the CFST columns being exposure to fire. 展开更多
关键词 contact thermal resistance temperature distribution concrete-filled steel tube heal transfer
下载PDF
Bending behaviour of lightweight aggregate concrete-filled steel tube spatial truss beam 被引量:3
5
作者 傅中秋 吉伯海 +1 位作者 朱伟 葛汉彬 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第8期2110-2117,共8页
A lightweight aggregate concrete-filled steel tube(LACFST) spatial truss beam was tested under bending load. The performance was studied by the analysis of the beam deflection and strains in its chords and webs. Accor... A lightweight aggregate concrete-filled steel tube(LACFST) spatial truss beam was tested under bending load. The performance was studied by the analysis of the beam deflection and strains in its chords and webs. According to the test results, several assumptions were made to deduce the bearing capacity calculation method based on the force balance of the whole section. An optimal dimension relationship for the truss beam chords was proposed and verified by finite element analysis. Results show that the LACFST spatial truss beam failed after excessive deflection. The strain distribution agreed with Bernoulli-Euler theoretical prediction. The truss beam flexural bearing capacity calculation results matched test evidence with only a 3% difference between the two. Finite element analyses with different chord dimensions show that the ultimate bearing capacity increases as the chord dimensions increase when the chords have a diameter smaller than optimal one; otherwise, it remains almost unchanged as the chord dimensions increase. 展开更多
关键词 lightweight aggregate concrete-filled steel tube spatial truss beam bending behaviour bearing capacity
下载PDF
Application of Compactness Detection to Complicated Concrete-Filled Steel Tube by Ultrasonic Method 被引量:1
6
作者 杨建江 王飞 +1 位作者 陆苏亮 王川 《Transactions of Tianjin University》 EI CAS 2014年第2期126-132,共7页
An example of using ultrasonic method to detect the compactness of complicated concrete-filled steel tube in certain high-rise building was discussed in this study.Because of the particularity of the complicated concr... An example of using ultrasonic method to detect the compactness of complicated concrete-filled steel tube in certain high-rise building was discussed in this study.Because of the particularity of the complicated concrete-filled steel tubular column,the plane detection method and embedded sounding pipe method were adopted in the process of effectively detecting the column.According to the results of the plane detection method and embedded sounding pipe method,the cementing status of steel tube and concrete can be concluded,which cannot be judged by the hammering method in the rectangular steel tube-reinforced concrete. 展开更多
关键词 ultrasonic method concrete-filled steel tube plane detection method embedded sounding pipe method COMPACTNESS
下载PDF
Concrete-Filled Steel Tube Arch Bridges in China 被引量:68
7
作者 Jielian Zheng Jianjun wang 《Engineering》 2018年第1期143-155,共13页
In the past 20 years, great progress has been achieved in China in the construction of concrete-filled steel tube (CFST) arch bridges and concrete arch bridges with a CFST skeleton. The span of these bridges has bee... In the past 20 years, great progress has been achieved in China in the construction of concrete-filled steel tube (CFST) arch bridges and concrete arch bridges with a CFST skeleton. The span of these bridges has been increasing rapidly, which is rare in the history of bridge development. The large-scale construction of expressways and high-speed railways demands the development of long-span arch bridges, and advances in design and construction techniques have made it possible to construct such bridges. In the present study, the current status, development, and major innovative technologies of CFST arch bridges and concrete arch bridges with a CFST skeleton in China are elaborated. This paper covers the key con- struction technologies of CFST arch bridges, such as the design, manufacture, and installation of steel tube arch trusses, the preparation and pouring of in-tube concrete, and the construction of the world's longest CFST arch bridge-the First Hejiang Yangtze River Bridge. The main construction technologies of rein- forced concrete arch bridges are also presented, which include cable-stayed fastening-hanging cantilever assembly, adjusting the load by means of stay cables, surrounding the concrete for arch rib pouring, and so forth. In addition, the construction of two CFST skeleton concrete arch bridges-the Guangxi Yongning Yong River Bridge and the Yunnan-Guangxi Railway Nanpan River Bridge--is discussed. CFST arch bridges in China have already gained a world-leading position; with the continuous innovation of key technologies, China will become the new leader in promoting the development of arch bridges. 展开更多
关键词 concrete-filled steel tube (CFST) ARCH BRIDGE steel-reinforced CONCRETE ARCH BRIDGE CABLE-STAYED fastening-hanging cantileverassembly VACUUM-ASSISTED pouring in-tube CONCRETE Adjusting load by stay cables
下载PDF
Reliability analysis of circular concrete-filled steel tube with material and geometrical nonlinearity 被引量:1
8
作者 Tengfei XU Tianyu XIANG +1 位作者 Yulin ZHAN Renda ZHAO 《Journal of Modern Transportation》 2012年第3期138-147,共10页
Most of the previous research on concrete-filled steel tube is restricted to a deterministic approach. To gain clear insight into the random properties of circular concrete-filled steel tube, reliability analysis is c... Most of the previous research on concrete-filled steel tube is restricted to a deterministic approach. To gain clear insight into the random properties of circular concrete-filled steel tube, reliability analysis is carried out in the present study. To obtain the Structural nonlinear response and ultimate resistance capacity, material and geometrical nonlinear analysis of circular concrete-filled steel tube is performed with a three-dimensional degenerated beam ele- ment. Then we investigate the reliability of concrete-filled steel tube using the first-order reliability method combined with nonlinear finite element analysis. The influences of such parameters as material strength, slenderness, initial geo- metrical imperfection, etc. on the reliability of circular concrete-filled steel tube column are studied. It can be con- cluded that inevitable random fluctuation of those parameters has significant influence on structural reliability, and that stochastic or reliability methods can provide a more rational and subjective evaluation on the safety of CFT structures than a deterministic approach. 展开更多
关键词 concrete-filled steel tube RELIABILITY material nonlinearity geometrical nonlinearity
下载PDF
A new calculation method for axial load capacity of separated concrete-filled steel tubes based on limit equilibrium theory
9
作者 刘夏平 孙卓 +2 位作者 唐述 黄海云 刘爱荣 《Journal of Central South University》 SCIE EI CAS 2013年第6期1750-1758,共9页
A new calculation method for axial load capacity of separated concrete-filled steel tubes based on limit equilibrium theory was proposed,which took into account the decrease of confinement effect by steel tube and the... A new calculation method for axial load capacity of separated concrete-filled steel tubes based on limit equilibrium theory was proposed,which took into account the decrease of confinement effect by steel tube and the non-uniform distribution of ultimate stress in cored concrete.The accuracy of the analytical result is validated through running the numerical result by finite element method (FEM) and experimental data as well.The influences of the key parameters on the load capacity of the concrete-filled steel tube (CFST) was studied,including the separation ratio,concrete compressive strength,and steel strength.The results indicate that the load capacity of the tube increases with concrete strength and steel strength under the separation ratio less than 4%,while decreases with a higher separation ratio improved. 展开更多
关键词 concrete-filled steel tube limit equilibrium theory axial load capacity
下载PDF
Experimental study on centrifugal concrete-filled steel tubes under bending and torsion
10
作者 金伟良 曲晨 于戈 《Journal of Zhejiang University Science》 EI CSCD 2003年第5期565-572,共8页
A real-size experiment on 11 tubes was done to study the performance o f centrifugal concrete-filled steel tubes under bending and torsion. This pape r first introduces the relevant operating method,equipment,subjects... A real-size experiment on 11 tubes was done to study the performance o f centrifugal concrete-filled steel tubes under bending and torsion. This pape r first introduces the relevant operating method,equipment,subjects and process es. The factors that affect deformation and stiffness and the break mechanism un der different loading were studied. Experimental stress analysis showed that the values of practical critical stress of steel tubes accorded well with the MISES Yielding Rule. The correlative equation (on the bearing capacity of a structura l member under bending and torsion) deduced in this study may provide valuable reference for the design of this structural member. 展开更多
关键词 Centrifugal concrete-filled steel tube Bending an d torsion Stiffness DISTORTION Bearing capacity
下载PDF
Ductility and Ultimate Capacity of Concrete-Filled Lattice Rectangular Steel Tube Columns
11
作者 Chengquan Wang Yun Zou +3 位作者 Tianqi Li Jie Ding Xiaoping Feng Tiange Lei 《Structural Durability & Health Monitoring》 EI 2018年第2期99-110,共12页
A kind of concrete-filled lattice rectangular steel tube(CFLRST)column was put forward.The numerical simulation was modeled to analyze the mechanical characteristic of CFLRST column.By comparing the load-deformation c... A kind of concrete-filled lattice rectangular steel tube(CFLRST)column was put forward.The numerical simulation was modeled to analyze the mechanical characteristic of CFLRST column.By comparing the load-deformation curves from the test results,the rationality and reliability of the finite element model has been confirmed,moreover,the change of the section stiffness and stress in the forcing process and the ultimate bearing capacity of the column were analyzed.Based on the model,the comparison of ultimate bearing capacity and ductility between CFLRST column and reinforced concrete(RC)column were also analyzed.The results of the finite element analysis show that the loading process of CFLRST column consists of elastic stage,yield stage and failure stage.The failure modes are mainly strength failure and failure of elastoplastic instability.CFLRST column has higher bearing capacities in comparison with reinforced concrete columns with the same steel ratio.In addition,the stiffness degeneration of CFLRST column is slower than RC column and CFLRST column has good ductility. 展开更多
关键词 steel-concrete composite structure concrete-filled lattice rectangular steel tube column nonlinear finite element ultimate strength DUCTILITY
下载PDF
Prediction of Axial Capacity of Concrete-Filled Square Steel Tubes Using Neural Networks
12
作者 朱美春 王清湘 冯秀峰 《Journal of Southwest Jiaotong University(English Edition)》 2005年第2期151-155,共5页
The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concret... The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concrete compressive strength, yield strength of steel tube, confinement index, sectional dimension and width-to-thickness ratio. The ultimate bearing capacity is the only output parameter. A multilayer feedforward neural network is used to describe the nonlinear relationships between the input and output variables. Fifty-five experimental data of CFST short columns under axial loading are used to train and test the neural network. A comparison between the neural network model and three parameter models shows that the neural network model possesses good accuracy and could be a practical method for predicting the ultimate strength of axially loaded CFST short columns. 展开更多
关键词 concrete-filled square steel tubes Neural networks Axial capacity Short columns
下载PDF
Axial Bearing Capacity of Short FRP Confined Concrete-filled Steel Tubular Columns 被引量:7
13
作者 刘兰 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2010年第3期454-458,共5页
The bearing capacity of FRP confined concrete-filled steel tubular (FRP-CFST) columns under axial compression was investigated. This new type of composite column is a concrete-filled steel tube (CFST) confined wit... The bearing capacity of FRP confined concrete-filled steel tubular (FRP-CFST) columns under axial compression was investigated. This new type of composite column is a concrete-filled steel tube (CFST) confined with fiber-reinforced polymer (FRP) wraps. Totally 11 short column specimens were tested to failure under axial compression. The influences of the type and quantity of FRP, the thickness of steel tube and the concrete strength were studied. It was found that the bearing capacity of short FRP-CFST column was much higher than that of comparable CFST column. Furthermore, the formulas for calculating the bearing capacity of the FRP-CFST columns are proposed. The analytical calculated results agree well with the experimental results. 展开更多
关键词 COLUMNS concrete-filled steel tubes (CFST) fiber reinforced polymer (FRP) CONFINEMENT bearing capacity.
下载PDF
Behavior of High Strength Concrete Filled Square Steel Tube Stub Columns with Inner CFRP Tube Under Biaxial Eccentric Compression 被引量:1
14
作者 Zhijian Yang Guochang Li +1 位作者 Yan Lang Zengmei Qiu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2021年第4期273-290,共18页
This paper studies the contribution of CFRP(carbon fiber-reinforced polymer)to the mechanical behavior of high strength concrete-filled square steel tube(HCFST)under biaxial eccentric compression.The new type of compo... This paper studies the contribution of CFRP(carbon fiber-reinforced polymer)to the mechanical behavior of high strength concrete-filled square steel tube(HCFST)under biaxial eccentric compression.The new type of composite member is composed of an inner CFRP tube and an outer steel tube with concrete filled in the two tubes.The finite element analysis was made by ABAQUS on the behavior of high strength concrete filled square steel tubular columns with inner CFRP circular tube subjected to bi-axial eccentric loading.The results obtained from the finite element analysis were verified with the experimental results.In addition,the load-deflection curves in the whole process were calculated and analyzed,which can be divided into three segments:Elastic phase,plastic phase,descending phase.Based on the load-deflection curves,the stresses analysis on the core concrete,CFRP tube and steel tube were conducted.The confinement effect of the CFRP tube improves the ductility of HCFST-CFRP stub column.CFRP ratio and eccentricity affect the ultimate bearing capacity of HCFST stub column.Finally,a calculation formula of ultimate bearing capacity was proposed in the paper. 展开更多
关键词 CFRP tube concrete-filled square steel tube high strength concrete bi-axial bending stub column
下载PDF
Expansive Performance of Self-stressing and Self-compacting Concrete Confined with Steel Tube
15
作者 徐磊 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2007年第2期341-345,共5页
Combining with the technology of self-compacting concrete, self-stressing concrete and concrete-filled steel tube, we can get self-compacting and self-stressing concrete-filled steel tube. In order to study the expans... Combining with the technology of self-compacting concrete, self-stressing concrete and concrete-filled steel tube, we can get self-compacting and self-stressing concrete-filled steel tube. In order to study the expansive mechanism of self-stressing concrete, the continuous observation of 47 days on six specimens was carried on. The specimens have different steel area to concrete area ratio. The expansive process in hoop and axial direction were studied, and the expansive mechanism was discussed too. The experimental results identify that the creep and elastic deformation take a large proportion in effective free expansion. The calculating formulas of self-stress in hoop and axial directions were presented here. 展开更多
关键词 self-compacting concrete self-stressing concrete concrete-filled steel tube restrained ex- pansion free expansion CREEP
下载PDF
局部环向变厚度方钢管混凝土柱偏压力学性能研究
16
作者 张望喜 廖宏臻 +3 位作者 解圆聪 张倚天 张瑾熠 易伟建 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2024年第5期1-11,共11页
针对海洋环境中飞溅区造成的钢管混凝土柱局部环向腐蚀现象,采用机械削减方式模拟钢管壁厚局部环向腐蚀,进行了7个方钢管混凝土柱偏压试验,揭示了削弱率和偏心率对其偏压承载力的影响,并通过数值模拟对削弱率进行拓展分析.提出了基于削... 针对海洋环境中飞溅区造成的钢管混凝土柱局部环向腐蚀现象,采用机械削减方式模拟钢管壁厚局部环向腐蚀,进行了7个方钢管混凝土柱偏压试验,揭示了削弱率和偏心率对其偏压承载力的影响,并通过数值模拟对削弱率进行拓展分析.提出了基于削弱率的偏压承载力降低系数,代入中、美规范进行偏压承载力计算.结果表明:钢管的局部环向变厚度严重削弱了方钢管混凝土柱的偏压承载力和侧向挠曲能力;较大的加载偏心率也降低了其偏压承载力,但增大了其侧向挠曲能力.引入偏压承载力降低系数后,根据中、美规范计算得到的偏压承载力与试验值均吻合较好;相比于我国规范,美国规范在计算偏压承载力时相对更加保守. 展开更多
关键词 方钢管混凝土 变厚度 偏压构件 有限元模拟 承载力计算修正
下载PDF
配筋空心方钢管高强混凝土纯弯构件受力性能有限元分析
17
作者 杨志坚 张澍 李帼昌 《沈阳建筑大学学报(自然科学版)》 CAS 北大核心 2024年第1期20-28,共9页
目的 研究配筋空心钢管高强混凝土构件的抗弯性能,推动其在建筑结构中的应用。方法 采用有限元分析软件ABAQUS建立配筋空心钢管混凝土构件有限元模型,在验证模型准确的基础上,分析构件的受力全过程及钢材屈服强度、混凝土抗压强度、钢... 目的 研究配筋空心钢管高强混凝土构件的抗弯性能,推动其在建筑结构中的应用。方法 采用有限元分析软件ABAQUS建立配筋空心钢管混凝土构件有限元模型,在验证模型准确的基础上,分析构件的受力全过程及钢材屈服强度、混凝土抗压强度、钢管壁厚、钢筋直径、普通钢筋数量对构件受弯性能的影响。结果 纯弯试件在荷载作用下受力过程可分为3个阶段:弹性阶段、弹塑性阶段和强化阶段;试件破坏形态均为受弯破坏,表现出较好地延性。结论 组合构件在弯矩作用下可以很好地协同工作;钢材屈服强度和钢管壁厚的增加对构件承载力的提高影响最显著,建议配置普通钢筋数量在6~8根为最优。 展开更多
关键词 空心方钢管混凝土 高强混凝土 纯弯构件 分担荷载
下载PDF
含钢率对GFRP管-钢骨混凝土组合构件抗冲击性能的影响
18
作者 张海霞 陈欢 鞠士龙 《爆炸与冲击》 EI CAS CSCD 北大核心 2024年第4期81-94,共14页
为了研究含钢率对GFRP(glass fiber reinforced polymer)管-钢骨混凝土组合构件抗冲击性能的影响,建立15个组合构件的数值模型,在验证模型正确的基础上,通过分析典型构件的冲击全过程、截面弯矩发展以及破坏时应变分布规律,研究构件在... 为了研究含钢率对GFRP(glass fiber reinforced polymer)管-钢骨混凝土组合构件抗冲击性能的影响,建立15个组合构件的数值模型,在验证模型正确的基础上,通过分析典型构件的冲击全过程、截面弯矩发展以及破坏时应变分布规律,研究构件在侧向冲击荷载作用下的破坏模式;通过分析构件冲击力时程曲线、侧移时程曲线以及能量变化情况,探究含钢率对不同长细比构件抗冲击性能的影响。结果表明:与未配置钢骨的构件相比,GFRP管-钢骨混凝土构件的抗冲击承载力提高了7%~134%,侧向位移减小了13%~68%。在侧向冲击荷载作用下,构件的破坏模式以弯曲破坏为主,同时伴随着GFRP管和混凝土冲击区域的局部破坏,抗弯刚度是影响构件抗冲击性能的主要因素之一。构件的抗冲击承载力随着含钢率的增高而提高,随着构件长细比的增大而降低。含钢率相差1.5%时,截面惯性矩较大的窄翼缘型钢对构件的抗冲击性能更有利。对于长细比大于20的构件,钢骨耗能是组合构件总能耗的主要组成部分。 展开更多
关键词 GFRP管-钢骨混凝土组合构件 侧向冲击 含钢率 破坏模式
下载PDF
广州白云国际会议中心国际会堂结构设计和施工重难点
19
作者 王嵩 江毅 梁韬 《建筑结构》 北大核心 2024年第15期89-95,共7页
采用YJK和ETABS对广州白云国际会议中心国际会堂结构进行弹性分析,采用Perform-3D进行罕遇地震作用下的整体结构弹塑性动力分析,并通过采取针对性的加强措施,改善了结构受力,提高了结构抗震性能,达到了预设的抗震性能目标。对大跨度钢... 采用YJK和ETABS对广州白云国际会议中心国际会堂结构进行弹性分析,采用Perform-3D进行罕遇地震作用下的整体结构弹塑性动力分析,并通过采取针对性的加强措施,改善了结构受力,提高了结构抗震性能,达到了预设的抗震性能目标。对大跨度钢结构构件进行方案选型,提出了大跨度钢结构桁架局部构件后装施工控制法和大悬挑钢结构桁架构件局部弯矩释放法,可以有效地减小结构构件局部受力,更加经济合理。对主会场大跨度楼盖进行竖向舒适度分析,结果表明竖向振动加速度满足规范要求,人群激励模式起控制性作用。通过采用合理的结构方案,以及与建筑专业的密切配合,很好地实现了建筑功能及建筑造型,以及项目快速建造的要求。 展开更多
关键词 方钢管混凝土柱+钢梁/钢桁架框架结构 大跨度 大悬挑 舒适度分析 局部构件后装施工控制法 构件局部弯矩释放法
下载PDF
Joint member angle limits of composite beams and CFT square columns 被引量:2
20
作者 LEE Seung-Jo LEE Kang-Guk 《Journal of Central South University》 SCIE EI CAS 2013年第1期199-206,共8页
This work aims to understand the relationship between the member angle limit and the energy ratio for 24 test samples of composite beams and CFT square steel tube columns. This work also compares the formula applicabi... This work aims to understand the relationship between the member angle limit and the energy ratio for 24 test samples of composite beams and CFT square steel tube columns. This work also compares the formula applicability for member angle limit with the previous test result to provide the basic data for the design of composite beam-CFT column. The evaluation of the member angle limit was performed with concrete compressive strength (fC =22.16 MPa, 30.49 MPa), breadth-to-thickness ratio (B/t=25.0, 33.3, 43.5), and axial capacity ratio (N/N0=0, 0.3, 0.4, 0.5) as the main variables of the test samples. For the relationship between the member angle limit (Ru) and the energy ratio (ES/EC ), the test result shows that the energy ratio becomes lower as the axial capacity ratio and the breadth-to-thickness ratio increase. The energy ratio is lower for the Type B test sample compared with that of Types A and C. For the formula suggested by SATO, the test samples are distributed evenly for comparison between test values and the member angle limit; however, other formulas indicate a deviation. Specifically, for the comparison between R u,cal and R u (Test), Maeda's formula shows severe deviation. 展开更多
关键词 square steel tube axial capacity ratio member angle limit breadth-to-thickness ratio
下载PDF
上一页 1 2 9 下一页 到第
使用帮助 返回顶部