In this paper, operation characteristic of condensate polishing system is studied during startup, based on generator blowdown limit, given limit ion concentration in condensate during condenser leakage. Further give c...In this paper, operation characteristic of condensate polishing system is studied during startup, based on generator blowdown limit, given limit ion concentration in condensate during condenser leakage. Further give conclusion about condensate polishing system configuration and operation requirement: full flow condensate polishing system (CPS) is necessary to the units cooled by sea water, and it is better that one or two series put in service during normal operation other than all of them in hot standby. While continuous condensate tube leakage is 256 L/h, the units cooled by fresh water will be shutdown immediately, for this level leakage, whichever condensate polishing system capacity is 50% (30%) or 100%, action level 2 will be preformed, so 50% (30%) is enough for fresh water cooled units.展开更多
Sulfate mass transfer coefficient(MTC) is a sensitive parameter to evaluate the kinetic leakage of anion exchange resin used in condensate polishing system of thermal and nuclear power plant.However,a sufficiently pre...Sulfate mass transfer coefficient(MTC) is a sensitive parameter to evaluate the kinetic leakage of anion exchange resin used in condensate polishing system of thermal and nuclear power plant.However,a sufficiently precise determination method has not been well established.In this paper,the final expression of sulfate MTC derived based on plug flow reactor model is the same as Harries' model,which is widely acknowledged in this field.In the determining system we constructed,in-situ calibration of the concentration of sulfate and its cation conductivity was conducted and sulfate MTCs of four typical strongly basic anion exchange resin samples were determined.The systematic error is 8.26% and the calibrated curve used for quantifying sulfate is obtained.The repeatability and reproducibility standard deviation are 0.05×10^(-4) m·s^(-1) and 0.07×10^(-4) m·s^(-1) respectively,which are lower than previous works.By controlling test condition accurately,this study has developed a more precise sulfate MTC determining method.This method provides a basis for further research.展开更多
In air-cooled condenser, high temperature condensing water m summer which approaching and exceed 60* C, which may result in filter materials degradation and release impurities. This paper discusses an influencing fac...In air-cooled condenser, high temperature condensing water m summer which approaching and exceed 60* C, which may result in filter materials degradation and release impurities. This paper discusses an influencing factor, water-filter ratio (soaking solution and filter quality ratio), on leachable dissolution rate and filter material degradation rate m high temperature water. The UV absorption at 254nm (A254) and the exchange capacity ware measured after heat test as composite indicators. In addition, the Wends of A254 variation with heating time were measured in different water-filter ratio. The stability is probably due to the effect of water-filter ratio. This has been further borne out that, water-filter ratio increases, leachable concentration decreases exponentially and tends to a fLxed value.展开更多
文摘In this paper, operation characteristic of condensate polishing system is studied during startup, based on generator blowdown limit, given limit ion concentration in condensate during condenser leakage. Further give conclusion about condensate polishing system configuration and operation requirement: full flow condensate polishing system (CPS) is necessary to the units cooled by sea water, and it is better that one or two series put in service during normal operation other than all of them in hot standby. While continuous condensate tube leakage is 256 L/h, the units cooled by fresh water will be shutdown immediately, for this level leakage, whichever condensate polishing system capacity is 50% (30%) or 100%, action level 2 will be preformed, so 50% (30%) is enough for fresh water cooled units.
文摘Sulfate mass transfer coefficient(MTC) is a sensitive parameter to evaluate the kinetic leakage of anion exchange resin used in condensate polishing system of thermal and nuclear power plant.However,a sufficiently precise determination method has not been well established.In this paper,the final expression of sulfate MTC derived based on plug flow reactor model is the same as Harries' model,which is widely acknowledged in this field.In the determining system we constructed,in-situ calibration of the concentration of sulfate and its cation conductivity was conducted and sulfate MTCs of four typical strongly basic anion exchange resin samples were determined.The systematic error is 8.26% and the calibrated curve used for quantifying sulfate is obtained.The repeatability and reproducibility standard deviation are 0.05×10^(-4) m·s^(-1) and 0.07×10^(-4) m·s^(-1) respectively,which are lower than previous works.By controlling test condition accurately,this study has developed a more precise sulfate MTC determining method.This method provides a basis for further research.
文摘In air-cooled condenser, high temperature condensing water m summer which approaching and exceed 60* C, which may result in filter materials degradation and release impurities. This paper discusses an influencing factor, water-filter ratio (soaking solution and filter quality ratio), on leachable dissolution rate and filter material degradation rate m high temperature water. The UV absorption at 254nm (A254) and the exchange capacity ware measured after heat test as composite indicators. In addition, the Wends of A254 variation with heating time were measured in different water-filter ratio. The stability is probably due to the effect of water-filter ratio. This has been further borne out that, water-filter ratio increases, leachable concentration decreases exponentially and tends to a fLxed value.