Using the finite element method (FEM) in two dimensions and the CST MICROWAVE STUDIO? (CST MWS) Transient Solver, the electromagnetic (EM) analysis and the design of a novel compact ultra wideband (UWB) bandpass filte...Using the finite element method (FEM) in two dimensions and the CST MICROWAVE STUDIO? (CST MWS) Transient Solver, the electromagnetic (EM) analysis and the design of a novel compact ultra wideband (UWB) bandpass filter using rectangular coaxial cables with square inner conductors, convenient for high power applications, are presented. The design of the UWB BP filter is based on the use of impedance steps and coupled-line sections. The center frequency around 6.85 GHz was selected, the bandwidth is between 3-10 GHz, the insertion-loss amounts to around 0.35 dB and the return loss is found higher than 10 dB in a large frequency range (4-9.5) GHz. The simulated results of stopband performances are better than 15 dB for a frequency range up to 11 GHz. For the selected center frequency and on a substrate with a dielectric constant of 2.03, the rectangular coaxial cables BPF with square inner conductors is only 6.7 × 8.9 × 33.4 mm in size.展开更多
Single-ion conductors based on covalent organic frameworks(COFs)have garnered attention as a potential alternative to currently prevalent inorganic ion conductors owing to their structural uniqueness and chemical vers...Single-ion conductors based on covalent organic frameworks(COFs)have garnered attention as a potential alternative to currently prevalent inorganic ion conductors owing to their structural uniqueness and chemical versatility.However,the sluggish Li+conduction has hindered their practical applications.Here,we present a class of solvent-free COF single-ion conductors(Li-COF@P)based on weak ion-dipole interaction as opposed to traditional strong ion-ion interaction.The ion(Li+from the COF)-dipole(oxygen from poly(ethylene glycol)diacrylate embedded in the COF pores)interaction in the Li-COF@P promotes ion dissociation and Li+migration via directional ionic channels.Driven by this single-ion transport behavior,the Li-COF@P enables reversible Li plating/stripping on Li-metal electrodes and stable cycling performance(88.3%after 2000 cycles)in organic batteries(Li metal anode||5,5’-dimethyl-2,2’-bis-p-benzoquinone(Me2BBQ)cathode)under ambient operating conditions,highlighting the electrochemical viability of the Li-COF@P for all-solid-state organic batteries.展开更多
High-temperature superconducting(HTS)rare-earth Ba_(2)Cu_(3)O_(7-x)(REBCO)coated conductors(CCs)have significant potential in high-current and high-field applications.However,owing to the weak interface strength of th...High-temperature superconducting(HTS)rare-earth Ba_(2)Cu_(3)O_(7-x)(REBCO)coated conductors(CCs)have significant potential in high-current and high-field applications.However,owing to the weak interface strength of the laminated composite REBCO CCs,the damage induced by the thermal mismatch stress under a combination of epoxy impregnation,cooling,and quenching can cause premature degradation of the critical current.In this study,a three-dimensional(3D)electromagnetic-thermal-mechanical model based on the H-formulation and cohesive zone model(CZM)is developed to study the critical current degradation characteristics in an epoxy-impregnated REBCO CC caused by the damage during a quench.The temperature variation,critical current degradation of the REBCO CC,and its degradation onset temperature calculated by the numerical model are in agreement with the experimental data taken from the literature.The delamination of the REBCO CC predicted by the numerical model is consistent with the experimental result.The numerical results also indicate that the shear stress is the main contributor to the damage propagation inside the REBCO CC.The premature degradation of the critical current during a quench is closely related to the interface shear strength inside the REBCO CC.Finally,the effects of the coefficient of thermal expansion(CTE)of the epoxy resin,thickness of the substrate,and substrate material on the critical current degradation characteristics of the epoxy-impregnated REBCO CC during a quench are also discussed.These results help us understand the relationship between the current-carrying degradation and damage in the HTS applications.展开更多
This paper studies the method for measuring the loop resistance of GIS conductor pole based on the super capacitor producing impulse current up to several thousand amperes. This method overcomes the limitations of con...This paper studies the method for measuring the loop resistance of GIS conductor pole based on the super capacitor producing impulse current up to several thousand amperes. This method overcomes the limitations of conventional diagnostic method. Typical GIS conductor poles are chosen. Based on FEA and lab tests, the effect of different forms of current and contact condition, relationship between the temperature of contact and the loop resistance is researched. In full- scale testing under realistic operating conditions on the new 220 kV GIS using prototype instrumentation a very good sensitivity in an early stage was obtained.展开更多
The proximity effect is very significant to investigate transient peak voltages and EMC related problems of a conductor system. In this paper, effect of energized single conductor in close proximity of an Al plate whe...The proximity effect is very significant to investigate transient peak voltages and EMC related problems of a conductor system. In this paper, effect of energized single conductor in close proximity of an Al plate when an Al plate is used as return path is investigated to find out proximity effect. The analysis involves simulation by the Finite Time Domain Method (FDTD) in comparison with field measurements. It is observed that the current distribution is uneven in pipe conductor due to the proximity effect of varying heights from ground.展开更多
Serious ice accumulating,pile-up and ice jamming occur around the conductor array of offshore jacket platforms during the winter every year in Bohai Sea,which could cause grave threats to the stability of platform str...Serious ice accumulating,pile-up and ice jamming occur around the conductor array of offshore jacket platforms during the winter every year in Bohai Sea,which could cause grave threats to the stability of platform structure,the safety of people and equipment,and even severer calamity.Therefore,the process of ice accumulation and ice jamming in the jacket platform area needs more concern.This study focuses on ice accumulation and jamming behaviors in the jacket platform conductor area by using a coupled two-dimensional hydro-ice dynamics model.A series of cases are conducted with different flow conditions,such as flow velocity,drifting direction and oscillatory flow.Through the simulation,the ice pile-up process is described and changes in ice-jamming thickness,ice pile-up location and ice pile-up volume are investigated.The differences in ice pile-up in the steady flow and oscillatory flow are analyzed.This study proposes a new approach to simulate the ice jamming process in the jacket platform conductor area,providing a reference for ice management on the platform.展开更多
A novel expandable conductor was designed and applied in deep-water drilling to improve the vertical and lateral bearing capacity with a significant reduction of conductor jetting depth and soaking time. The vertical ...A novel expandable conductor was designed and applied in deep-water drilling to improve the vertical and lateral bearing capacity with a significant reduction of conductor jetting depth and soaking time. The vertical and lateral bearing capability of expandable conductors was depicted based on the ultimate subgrade reaction method and pile foundation bearing theory. The load-bearing characteristics of a laboratory-scale expandable conductor were analyzed through laboratory experiments. The serial simulation experiments are accomplished to study the bearing characteristics(vertical ultimate bearing capacity, lateral soil pressure, and lateral displacement) during the conductor soaking process. The laboratory experimental results show that the larger the length and thickness of expandable materials are,the higher the bearing capacity of the wellhead will be. During the conductor soaking process, the soil pressure around the three expandable conductors increases faster, strings representing a stronger squeezing effect and resulting in higher vertical bearing capacity. Furthermore, the lateral displacement of novel expandable conductor is smaller than that of the conventional conductor. All the advantages mentioned above contributed to the reduction of conductor’s jetting depth and soaking time. Lastly, the application workflow of a novel expandable deep-water drilling conductor was established and the autonomous expandable conductor was successfully applied in the South China Sea with a significant reduction of conductor’s jetting depth and soaking time. According to the soil properties and designed installation depth of the surface conductor, the arrangement of expandable materials should be designed reasonably to meet the safety condition and reduce the construction cost of the subsea wellhead.展开更多
A floating conductor exhibits a bipolar corona phenomenon with microscopic discharge characteristics that are still unclear.In this study,a plasma simulation model of the bipolar corona with 108 chemical reaction equa...A floating conductor exhibits a bipolar corona phenomenon with microscopic discharge characteristics that are still unclear.In this study,a plasma simulation model of the bipolar corona with 108 chemical reaction equations is established by combining hydrodynamics and plasma chemical reactions.The evolution characteristics of electrons,positive ions,negative ions and neutral particles,as well as the distribution characteristics of space charges are analyzed,and the evolutionary flow of microscopic particles is summarized.The results indicate that the positive end of the bipolar corona initiates discharge before the negative end,but the plasma chemistry at the negative end is more vigorous.The electron generation rate can reach 1240 mol(m^(3) s)^(-1),and the dissipation rate can reach 34 mol(m^(3) s)^(-1).The positive ion swarm is dominated by O_(4)^(+),and the maximum generation rate can reach 440 mol((m^(3) s)^(-1).The negative ion swarm is mainly O_(2) and O_(4).The O_(2) content is approximately 1.5-3 times that of O_(4),and the maximum reaction rate can reach 51 mol(m^(3) s)^(-1).The final destination of neutral particles is an accumulation in the form of O_(3) and NO,and the amount of O3 produced is approximately 4-6 times that of NO.The positive end of the bipolar corona is dominated by positive space charges,which continue to develop and spread outwards in the form of a pulse wave.The negative end exhibits a space charge distribution structure of concentrated positive charges and diffused negative charges.The validity of the microscopic simulation analysis is verified by the macroscopic discharge phenomenon.展开更多
In the harsh environment,the structural health of the anti-vibration hammer,which suffers from the coupled effects of corrosion and fatigue damage,is significantly reduced.As part of the conductor structure,the anti-v...In the harsh environment,the structural health of the anti-vibration hammer,which suffers from the coupled effects of corrosion and fatigue damage,is significantly reduced.As part of the conductor structure,the anti-vibration hammer is rigidly attached to the conductor,effectively suppressing conductor vibration.The conductor’s breeze vibration law and natural modal frequency are altered damage to the anti-vibration hammer structure.Through built a vibration experiment platform to simulate multiple faults such as anti-vibration hammer head drop off and position slippage,which to obtained the vibration acceleration signal of the conductor.The acceleration vibration signal is processed and analyzed in the time and frequency domains.The results are used to derive the breeze vibration law of the conductor under multiple faults and propose an anti-vibration hammer damage online monitoring technology.The results show that the vibration acceleration value and vibration intensity of the conductor are significantly increased after the anti-vibration hammer damage.The natural frequency increases for each order,with an absolute change ranging from 0.15 to 6.49 Hz.The anti-vibration hammer slipped due to a loose connection,the 1st natural frequency increases from 8.18 to 16.62 Hz.Therefore,in engineering applications,there can be no contact to determine the anti-vibration hammer damage situation by monitoring the modal natural frequency of the conductor.This is even a tiny damage that cannot be seen.This method will prevent the further expansion of the damage that can cause accidents.展开更多
On the basis of expounding the corrosion mechanism of the stator hollow copper conductor in the water-cooling generator, methods of preventing corrosion of the stator hollow copper conductor in the wa-ter-cooling gene...On the basis of expounding the corrosion mechanism of the stator hollow copper conductor in the water-cooling generator, methods of preventing corrosion of the stator hollow copper conductor in the wa-ter-cooling generator through adjusting water quality of its cooling water have been proposed. For internal water cooling systems which are airtight, the corrosion of the hollow copper conductor can be prevented through keeping foreign oxygen and carbon dioxide from entering the system, and the amount of oxygen in the internal water can be lowered by blowing high purity nitrogen. For systems not airtight, the corrosion of the hollow copper conductor can be inhibited through lowering the amount of oxygen to some extent by sealing and increasing pH value by processing part of cooling water with bypass small flow sodium-type mix-bed.展开更多
Conductor externalization and insulation failure are frequent complications with the recalled St. Jude Medical Riata implantable cardioverter-defibrillator(ICD) leads. Conductor externalization is a "unique"...Conductor externalization and insulation failure are frequent complications with the recalled St. Jude Medical Riata implantable cardioverter-defibrillator(ICD) leads. Conductor externalization is a "unique" failure mechanism: Cables externalize through the insulation("inside-out" abrasion) and appear outside the lead body. Recently, single reports described a similar failure also for Biotronik leads. Moreover, some studies reported a high rate of electrical dysfunction(not only insulation failure) with Biotronik Linox leads and a reduced survival rate in comparison with the competitors. In this paper we describe the case of a patient with a Biotronik Kentrox ICD lead presenting with signs of insulation failure and conductor externalization at fluoroscopy. Due to the high risk of extraction we decided to implant a new lead, abandoning the damaged one; lead reimplant was uneventful. Subsequently, we review currently available literature about Biotronik Kentrox and Linox ICD lead failure and in particular externalized conductors. Some single-center studies and a nonprospective registry reported a survival rate between 88% and 91% at 5 years for Linox leads, significantly worse than that of other manufacturers. However, the preliminary results of two ongoing multicenter, prospective registries(GALAXY and CELESTIAL) showed 96% survival rate at 5 years after implant, well within industry standards. Ongoing data collection is needed to confirm longer-term performance of this family of ICD leads.展开更多
Turbulence is expected to play a relevant role in the so-called conductor gallop phenomena,namely,the high-amplitude,low-frequency oscillation of overhead power lines due to the formation of ice structures and the ens...Turbulence is expected to play a relevant role in the so-called conductor gallop phenomena,namely,the high-amplitude,low-frequency oscillation of overhead power lines due to the formation of ice structures and the ensu-ing effect that wind can have on these.In this work,the galloping time history of a wire with distorted(fixed in time)shape due to the formation of ice is analyzed numerically in the frame of afluid-solid coupling method for different wind speeds and levels of turbulence.The results show that the turbulence intensity has a moderate effect on the increase of the conductor’s aerodynamic lift and drag coefficients due to ice accretion;nevertheless,the corresponding changes in the torsion coefficient are very significant and complicated.A high turbulence intensity can affect the torsion coefficient in a certain range of attack angles and increase the torsion angle of the conductor.Through comparison of the galloping phenomena for different wind velocities,it is found that the related amplitude grows significantly with an increase of the wind speed.For a relatively large wind speed,the galloping amplitude is more sensitive to the turbulence intensity.Moreover,the larger the turbulence intensity,the larger the conductor’s vertical and horizontal galloping amplitudes after icing.The torsion angle also increases with an increase in the wind speed and turbulence intensity.展开更多
A novel planar leaky-wave antenna of conductor modulating periodic structure formillimeter wave application is proposed.Using the theory of two-dimensional periodic admittancesurface,theoretical analysis,numerical cal...A novel planar leaky-wave antenna of conductor modulating periodic structure formillimeter wave application is proposed.Using the theory of two-dimensional periodic admittancesurface,theoretical analysis,numerical calculation and experimental study are carried out for thiskind of antenna.A planar antenna of conductor modulating periodic structure is realized in 8mmwave band.It has an aperture area of 90×90mm^2.The measured performances of the antennaare good.展开更多
A novel solid solution Ce6MoO15 was achieved. Their structure and oxide ionic conductivity were studied.Based on Ce6MoO15, rare earth element substitution on cerium site shows that all resulting oxides enhance the con...A novel solid solution Ce6MoO15 was achieved. Their structure and oxide ionic conductivity were studied.Based on Ce6MoO15, rare earth element substitution on cerium site shows that all resulting oxides enhance the conductivity further, and have high oxide-ion conductivity, which may be a kind of promising material for SOFCs.展开更多
In research of YBCO coated conductors, the development of a oxide template for epitaxial growth of YBCO is very important. Matsumoto et al have demonstrated the potential of the surface oxidation epitaxial (SOE) route...In research of YBCO coated conductors, the development of a oxide template for epitaxial growth of YBCO is very important. Matsumoto et al have demonstrated the potential of the surface oxidation epitaxial (SOE) route for formation a cube textured NiO layer on nickel tapes. The epitaxial NiO functions as a buffer layer of chemical reaction between YBCO and nickel, and as a template for the epitaxial growth of YBCO. However, the surface quality of NiO is difficult to control and defects such as crack, spall and deep grooves exist in SOE NiO layer. A new approach combining sputtering and SOE method to obtain crack-free and cube textured NiO layer were reported. Ni tapes prepared by the combination of rolling and recrystallization were used for this work. A coating of Ni was first deposited on the tapes via magnetron sputtering. Then on the coating tapes, continuous and textured NiO layer were achieved by SOE technology.展开更多
Ice accumulation on transmission lines often leads to great damage to power systems.Super-hydrophobic surfaces are proposed to inhibit ice accumulation on electrical power equipment.A novel anti-icing method was prese...Ice accumulation on transmission lines often leads to great damage to power systems.Super-hydrophobic surfaces are proposed to inhibit ice accumulation on electrical power equipment.A novel anti-icing method was presented for conductors with super-hydrophobic sleeves.The super-hydrophobic sleeves were prepared by applying polydimethylsiloxane(PDMS) and nano-silica hybrid coating on the outer surface of polyethylen terephthalate(PET) sleeves.Hydrophobicity and ice adhesion strength of the super-hydrophobic surface were investigated.Ice accumulation experiments were carried out on ordinary conductors,super-hydrophobic coated conductors,PET sleeve-covered conductors,and super-hydrophobic PET sleeve-covered conductors.Ice accumulation morphology,accumulated ice weight,and the icicle length of these four types of conductors were studied and analyzed.At the end of the 3 h ice accumulation experiment,the ice weight and icicle length on the conductor with super-hydrophobic PET sleeve was only approximately one tenth and one seventh of that on the untreated conductor respectively.Furthermore,the water contact angles of super-hydrophobic coated aluminum surface and super-hydrophobic coated PET sleeve were about 163o in average.The results indicate that the super-hydrophobic coating is effective in inhibiting ice accumulation on conductors.However,the use of a super-hydrophobic PET sleeve is a significantly more effective method,comparing with the application of a super-hydrophobic coating directly on the conductor.展开更多
YBa2Cu3O7-x(YBCO) films were fabricated on an LAO substrate using the trifluoroacetic acid-metal organic deposition(TFA-MOD) method and the effects of the humidity and heat treatment temperatures on the microstructure...YBa2Cu3O7-x(YBCO) films were fabricated on an LAO substrate using the trifluoroacetic acid-metal organic deposition(TFA-MOD) method and the effects of the humidity and heat treatment temperatures on the microstructure,degree of texture and critical properties of the films were evaluated.In order to understand the combined effects of the humidity and the calcining and firing temperatures on critical properties,heat-treatment was performed at various temperatures with the other processing variables fixed.The films were calcined at 400-430 ℃ and fired at 750-800 ℃ in a 0-12.1% humidified Ar-O2 atmosphere.The texture was determined by pole-figure analysis.The amount of the BaF2 phase was effectively reduced and a sharp and strong biaxial texture was formed under a humidified atmosphere,which led to increased critical properties.In addition,the microstructure varied significantly with firing temperature but changed little with calcining temperature.The highest IC of 40 A/cm-width,which corresponds to JC value of 1.8 MA/cm2,was obtained for the films fired at 775 ℃(in 12.1% humidity) after calcining at 400-430 ℃.It is likely that the highest IC value is due to the formation of a more pure YBCO phase,c-axis grains,and a denser microstructure.展开更多
The dynamic behaviour of power line cables have been a source of interest to researchers ever since the phenomenon was first noticed in the 1920s. Conductor oscillation is mostly caused by the dynamic forces of nature...The dynamic behaviour of power line cables have been a source of interest to researchers ever since the phenomenon was first noticed in the 1920s. Conductor oscillation is mostly caused by the dynamic forces of nature such as wind loading. This imposes a periodic force on the conductors which is highly undesirable. It is therefore important for engineers to account for the possible effect of the wind loading when designing the power line. Investigations have shown that modeling the exact dynamic behaviour of a conductor is very difficult. Based on this fact, getting the exact analytical solution to conductor vibration is difficult, which is almost impossible, hence the numerical approximation becomes an option. This paper presents the developed finite element method used to analyse the dynamic behaviour of transmission line conductors. The developed FEM (finite element method) is implemented on MATLAB. The numerical analysis using MATLAB that is presented in this paper is used to simulate the response of the conductor when subjected to external loading in the time domain. The simulation is used to analyse the transverse vibration of the conductor. The formulation of the stiffness matrix and load vector is done and the results obtained are used to evaluate the conductor's internal energy dissipation. This finite element solution is compared with the results documented in literature. This numerical simulation is also used to investigate the effects of varying the axial tension on energy dissipation within the strands. Hence, this evolved in physically appropriate energy characterization process that can be used to evaluate the conductor self-damping with respect to line contact.展开更多
文摘Using the finite element method (FEM) in two dimensions and the CST MICROWAVE STUDIO? (CST MWS) Transient Solver, the electromagnetic (EM) analysis and the design of a novel compact ultra wideband (UWB) bandpass filter using rectangular coaxial cables with square inner conductors, convenient for high power applications, are presented. The design of the UWB BP filter is based on the use of impedance steps and coupled-line sections. The center frequency around 6.85 GHz was selected, the bandwidth is between 3-10 GHz, the insertion-loss amounts to around 0.35 dB and the return loss is found higher than 10 dB in a large frequency range (4-9.5) GHz. The simulated results of stopband performances are better than 15 dB for a frequency range up to 11 GHz. For the selected center frequency and on a substrate with a dielectric constant of 2.03, the rectangular coaxial cables BPF with square inner conductors is only 6.7 × 8.9 × 33.4 mm in size.
基金supported by the Basic Science Research Program (No.RS-2024-00344021) through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT and future Planningthe financial support from the National Natural Science Foundation of China (52103277)+2 种基金the Program for Science & Technology Innovation Talents in Universities of Henan Province (23HASTIT015)Natural Science Foundation of Henan Province (242300421073)supported by the Technology Innovation Program (20010960) funded by the Ministry of Trade, Industry & Energy (MOTIE, Korea)
文摘Single-ion conductors based on covalent organic frameworks(COFs)have garnered attention as a potential alternative to currently prevalent inorganic ion conductors owing to their structural uniqueness and chemical versatility.However,the sluggish Li+conduction has hindered their practical applications.Here,we present a class of solvent-free COF single-ion conductors(Li-COF@P)based on weak ion-dipole interaction as opposed to traditional strong ion-ion interaction.The ion(Li+from the COF)-dipole(oxygen from poly(ethylene glycol)diacrylate embedded in the COF pores)interaction in the Li-COF@P promotes ion dissociation and Li+migration via directional ionic channels.Driven by this single-ion transport behavior,the Li-COF@P enables reversible Li plating/stripping on Li-metal electrodes and stable cycling performance(88.3%after 2000 cycles)in organic batteries(Li metal anode||5,5’-dimethyl-2,2’-bis-p-benzoquinone(Me2BBQ)cathode)under ambient operating conditions,highlighting the electrochemical viability of the Li-COF@P for all-solid-state organic batteries.
基金Project supported by the National Natural Science Foundation of China(Nos.12302278,U2241267,12172155,and 11932008)the Fundamental Research Funds for the Central Universities of China(No.lzujbky-2022-48)the Natural Science Foundation of Gansu Province of China(No.24JRRA473)。
文摘High-temperature superconducting(HTS)rare-earth Ba_(2)Cu_(3)O_(7-x)(REBCO)coated conductors(CCs)have significant potential in high-current and high-field applications.However,owing to the weak interface strength of the laminated composite REBCO CCs,the damage induced by the thermal mismatch stress under a combination of epoxy impregnation,cooling,and quenching can cause premature degradation of the critical current.In this study,a three-dimensional(3D)electromagnetic-thermal-mechanical model based on the H-formulation and cohesive zone model(CZM)is developed to study the critical current degradation characteristics in an epoxy-impregnated REBCO CC caused by the damage during a quench.The temperature variation,critical current degradation of the REBCO CC,and its degradation onset temperature calculated by the numerical model are in agreement with the experimental data taken from the literature.The delamination of the REBCO CC predicted by the numerical model is consistent with the experimental result.The numerical results also indicate that the shear stress is the main contributor to the damage propagation inside the REBCO CC.The premature degradation of the critical current during a quench is closely related to the interface shear strength inside the REBCO CC.Finally,the effects of the coefficient of thermal expansion(CTE)of the epoxy resin,thickness of the substrate,and substrate material on the critical current degradation characteristics of the epoxy-impregnated REBCO CC during a quench are also discussed.These results help us understand the relationship between the current-carrying degradation and damage in the HTS applications.
文摘This paper studies the method for measuring the loop resistance of GIS conductor pole based on the super capacitor producing impulse current up to several thousand amperes. This method overcomes the limitations of conventional diagnostic method. Typical GIS conductor poles are chosen. Based on FEA and lab tests, the effect of different forms of current and contact condition, relationship between the temperature of contact and the loop resistance is researched. In full- scale testing under realistic operating conditions on the new 220 kV GIS using prototype instrumentation a very good sensitivity in an early stage was obtained.
文摘The proximity effect is very significant to investigate transient peak voltages and EMC related problems of a conductor system. In this paper, effect of energized single conductor in close proximity of an Al plate when an Al plate is used as return path is investigated to find out proximity effect. The analysis involves simulation by the Finite Time Domain Method (FDTD) in comparison with field measurements. It is observed that the current distribution is uneven in pipe conductor due to the proximity effect of varying heights from ground.
基金jointly supported by the National Key R&D Program of China (Grant No.2021YFB2600700)the Central PublicInterest Scientific Institution Basal Research Fund of China (Grant Nos.Y221007 and Y223005)。
文摘Serious ice accumulating,pile-up and ice jamming occur around the conductor array of offshore jacket platforms during the winter every year in Bohai Sea,which could cause grave threats to the stability of platform structure,the safety of people and equipment,and even severer calamity.Therefore,the process of ice accumulation and ice jamming in the jacket platform area needs more concern.This study focuses on ice accumulation and jamming behaviors in the jacket platform conductor area by using a coupled two-dimensional hydro-ice dynamics model.A series of cases are conducted with different flow conditions,such as flow velocity,drifting direction and oscillatory flow.Through the simulation,the ice pile-up process is described and changes in ice-jamming thickness,ice pile-up location and ice pile-up volume are investigated.The differences in ice pile-up in the steady flow and oscillatory flow are analyzed.This study proposes a new approach to simulate the ice jamming process in the jacket platform conductor area,providing a reference for ice management on the platform.
基金financially supported by the National Natural Science Foundation of China (Grant Nos.51434009 and 51221003)。
文摘A novel expandable conductor was designed and applied in deep-water drilling to improve the vertical and lateral bearing capacity with a significant reduction of conductor jetting depth and soaking time. The vertical and lateral bearing capability of expandable conductors was depicted based on the ultimate subgrade reaction method and pile foundation bearing theory. The load-bearing characteristics of a laboratory-scale expandable conductor were analyzed through laboratory experiments. The serial simulation experiments are accomplished to study the bearing characteristics(vertical ultimate bearing capacity, lateral soil pressure, and lateral displacement) during the conductor soaking process. The laboratory experimental results show that the larger the length and thickness of expandable materials are,the higher the bearing capacity of the wellhead will be. During the conductor soaking process, the soil pressure around the three expandable conductors increases faster, strings representing a stronger squeezing effect and resulting in higher vertical bearing capacity. Furthermore, the lateral displacement of novel expandable conductor is smaller than that of the conventional conductor. All the advantages mentioned above contributed to the reduction of conductor’s jetting depth and soaking time. Lastly, the application workflow of a novel expandable deep-water drilling conductor was established and the autonomous expandable conductor was successfully applied in the South China Sea with a significant reduction of conductor’s jetting depth and soaking time. According to the soil properties and designed installation depth of the surface conductor, the arrangement of expandable materials should be designed reasonably to meet the safety condition and reduce the construction cost of the subsea wellhead.
基金supported by the Aeronautical Science Foundation of China(No.201944057001)the National Key Research and Development Program of China(No.2017YFC1501506).
文摘A floating conductor exhibits a bipolar corona phenomenon with microscopic discharge characteristics that are still unclear.In this study,a plasma simulation model of the bipolar corona with 108 chemical reaction equations is established by combining hydrodynamics and plasma chemical reactions.The evolution characteristics of electrons,positive ions,negative ions and neutral particles,as well as the distribution characteristics of space charges are analyzed,and the evolutionary flow of microscopic particles is summarized.The results indicate that the positive end of the bipolar corona initiates discharge before the negative end,but the plasma chemistry at the negative end is more vigorous.The electron generation rate can reach 1240 mol(m^(3) s)^(-1),and the dissipation rate can reach 34 mol(m^(3) s)^(-1).The positive ion swarm is dominated by O_(4)^(+),and the maximum generation rate can reach 440 mol((m^(3) s)^(-1).The negative ion swarm is mainly O_(2) and O_(4).The O_(2) content is approximately 1.5-3 times that of O_(4),and the maximum reaction rate can reach 51 mol(m^(3) s)^(-1).The final destination of neutral particles is an accumulation in the form of O_(3) and NO,and the amount of O3 produced is approximately 4-6 times that of NO.The positive end of the bipolar corona is dominated by positive space charges,which continue to develop and spread outwards in the form of a pulse wave.The negative end exhibits a space charge distribution structure of concentrated positive charges and diffused negative charges.The validity of the microscopic simulation analysis is verified by the macroscopic discharge phenomenon.
基金supported by the National Natural Science Foundation of China(No.52007138)the Natural Science Basis Research Plan in Shaanxi Province of China(No.2022JQ-568)the Key Research and Development Program of Shaanxi Province(No.2023-YBGY-069).
文摘In the harsh environment,the structural health of the anti-vibration hammer,which suffers from the coupled effects of corrosion and fatigue damage,is significantly reduced.As part of the conductor structure,the anti-vibration hammer is rigidly attached to the conductor,effectively suppressing conductor vibration.The conductor’s breeze vibration law and natural modal frequency are altered damage to the anti-vibration hammer structure.Through built a vibration experiment platform to simulate multiple faults such as anti-vibration hammer head drop off and position slippage,which to obtained the vibration acceleration signal of the conductor.The acceleration vibration signal is processed and analyzed in the time and frequency domains.The results are used to derive the breeze vibration law of the conductor under multiple faults and propose an anti-vibration hammer damage online monitoring technology.The results show that the vibration acceleration value and vibration intensity of the conductor are significantly increased after the anti-vibration hammer damage.The natural frequency increases for each order,with an absolute change ranging from 0.15 to 6.49 Hz.The anti-vibration hammer slipped due to a loose connection,the 1st natural frequency increases from 8.18 to 16.62 Hz.Therefore,in engineering applications,there can be no contact to determine the anti-vibration hammer damage situation by monitoring the modal natural frequency of the conductor.This is even a tiny damage that cannot be seen.This method will prevent the further expansion of the damage that can cause accidents.
文摘On the basis of expounding the corrosion mechanism of the stator hollow copper conductor in the water-cooling generator, methods of preventing corrosion of the stator hollow copper conductor in the wa-ter-cooling generator through adjusting water quality of its cooling water have been proposed. For internal water cooling systems which are airtight, the corrosion of the hollow copper conductor can be prevented through keeping foreign oxygen and carbon dioxide from entering the system, and the amount of oxygen in the internal water can be lowered by blowing high purity nitrogen. For systems not airtight, the corrosion of the hollow copper conductor can be inhibited through lowering the amount of oxygen to some extent by sealing and increasing pH value by processing part of cooling water with bypass small flow sodium-type mix-bed.
文摘Conductor externalization and insulation failure are frequent complications with the recalled St. Jude Medical Riata implantable cardioverter-defibrillator(ICD) leads. Conductor externalization is a "unique" failure mechanism: Cables externalize through the insulation("inside-out" abrasion) and appear outside the lead body. Recently, single reports described a similar failure also for Biotronik leads. Moreover, some studies reported a high rate of electrical dysfunction(not only insulation failure) with Biotronik Linox leads and a reduced survival rate in comparison with the competitors. In this paper we describe the case of a patient with a Biotronik Kentrox ICD lead presenting with signs of insulation failure and conductor externalization at fluoroscopy. Due to the high risk of extraction we decided to implant a new lead, abandoning the damaged one; lead reimplant was uneventful. Subsequently, we review currently available literature about Biotronik Kentrox and Linox ICD lead failure and in particular externalized conductors. Some single-center studies and a nonprospective registry reported a survival rate between 88% and 91% at 5 years for Linox leads, significantly worse than that of other manufacturers. However, the preliminary results of two ongoing multicenter, prospective registries(GALAXY and CELESTIAL) showed 96% survival rate at 5 years after implant, well within industry standards. Ongoing data collection is needed to confirm longer-term performance of this family of ICD leads.
基金This work was supported in part by the National Natural Science Foundation of China[Grant No.51867013].
文摘Turbulence is expected to play a relevant role in the so-called conductor gallop phenomena,namely,the high-amplitude,low-frequency oscillation of overhead power lines due to the formation of ice structures and the ensu-ing effect that wind can have on these.In this work,the galloping time history of a wire with distorted(fixed in time)shape due to the formation of ice is analyzed numerically in the frame of afluid-solid coupling method for different wind speeds and levels of turbulence.The results show that the turbulence intensity has a moderate effect on the increase of the conductor’s aerodynamic lift and drag coefficients due to ice accretion;nevertheless,the corresponding changes in the torsion coefficient are very significant and complicated.A high turbulence intensity can affect the torsion coefficient in a certain range of attack angles and increase the torsion angle of the conductor.Through comparison of the galloping phenomena for different wind velocities,it is found that the related amplitude grows significantly with an increase of the wind speed.For a relatively large wind speed,the galloping amplitude is more sensitive to the turbulence intensity.Moreover,the larger the turbulence intensity,the larger the conductor’s vertical and horizontal galloping amplitudes after icing.The torsion angle also increases with an increase in the wind speed and turbulence intensity.
文摘A novel planar leaky-wave antenna of conductor modulating periodic structure formillimeter wave application is proposed.Using the theory of two-dimensional periodic admittancesurface,theoretical analysis,numerical calculation and experimental study are carried out for thiskind of antenna.A planar antenna of conductor modulating periodic structure is realized in 8mmwave band.It has an aperture area of 90×90mm^2.The measured performances of the antennaare good.
文摘A novel solid solution Ce6MoO15 was achieved. Their structure and oxide ionic conductivity were studied.Based on Ce6MoO15, rare earth element substitution on cerium site shows that all resulting oxides enhance the conductivity further, and have high oxide-ion conductivity, which may be a kind of promising material for SOFCs.
文摘In research of YBCO coated conductors, the development of a oxide template for epitaxial growth of YBCO is very important. Matsumoto et al have demonstrated the potential of the surface oxidation epitaxial (SOE) route for formation a cube textured NiO layer on nickel tapes. The epitaxial NiO functions as a buffer layer of chemical reaction between YBCO and nickel, and as a template for the epitaxial growth of YBCO. However, the surface quality of NiO is difficult to control and defects such as crack, spall and deep grooves exist in SOE NiO layer. A new approach combining sputtering and SOE method to obtain crack-free and cube textured NiO layer were reported. Ni tapes prepared by the combination of rolling and recrystallization were used for this work. A coating of Ni was first deposited on the tapes via magnetron sputtering. Then on the coating tapes, continuous and textured NiO layer were achieved by SOE technology.
基金Project supported by National Natural Science Foundation of China(51107152), Ftmd for Innovation Research Groups(51021005), Key Science and Technology Project of Chongqing Eleelric Power Company (2012 Yu Electricity Science and Technoloyg 18).
文摘Ice accumulation on transmission lines often leads to great damage to power systems.Super-hydrophobic surfaces are proposed to inhibit ice accumulation on electrical power equipment.A novel anti-icing method was presented for conductors with super-hydrophobic sleeves.The super-hydrophobic sleeves were prepared by applying polydimethylsiloxane(PDMS) and nano-silica hybrid coating on the outer surface of polyethylen terephthalate(PET) sleeves.Hydrophobicity and ice adhesion strength of the super-hydrophobic surface were investigated.Ice accumulation experiments were carried out on ordinary conductors,super-hydrophobic coated conductors,PET sleeve-covered conductors,and super-hydrophobic PET sleeve-covered conductors.Ice accumulation morphology,accumulated ice weight,and the icicle length of these four types of conductors were studied and analyzed.At the end of the 3 h ice accumulation experiment,the ice weight and icicle length on the conductor with super-hydrophobic PET sleeve was only approximately one tenth and one seventh of that on the untreated conductor respectively.Furthermore,the water contact angles of super-hydrophobic coated aluminum surface and super-hydrophobic coated PET sleeve were about 163o in average.The results indicate that the super-hydrophobic coating is effective in inhibiting ice accumulation on conductors.However,the use of a super-hydrophobic PET sleeve is a significantly more effective method,comparing with the application of a super-hydrophobic coating directly on the conductor.
基金supported by Samsung Research Fund,Sungkyunkwan University,2006
文摘YBa2Cu3O7-x(YBCO) films were fabricated on an LAO substrate using the trifluoroacetic acid-metal organic deposition(TFA-MOD) method and the effects of the humidity and heat treatment temperatures on the microstructure,degree of texture and critical properties of the films were evaluated.In order to understand the combined effects of the humidity and the calcining and firing temperatures on critical properties,heat-treatment was performed at various temperatures with the other processing variables fixed.The films were calcined at 400-430 ℃ and fired at 750-800 ℃ in a 0-12.1% humidified Ar-O2 atmosphere.The texture was determined by pole-figure analysis.The amount of the BaF2 phase was effectively reduced and a sharp and strong biaxial texture was formed under a humidified atmosphere,which led to increased critical properties.In addition,the microstructure varied significantly with firing temperature but changed little with calcining temperature.The highest IC of 40 A/cm-width,which corresponds to JC value of 1.8 MA/cm2,was obtained for the films fired at 775 ℃(in 12.1% humidity) after calcining at 400-430 ℃.It is likely that the highest IC value is due to the formation of a more pure YBCO phase,c-axis grains,and a denser microstructure.
文摘The dynamic behaviour of power line cables have been a source of interest to researchers ever since the phenomenon was first noticed in the 1920s. Conductor oscillation is mostly caused by the dynamic forces of nature such as wind loading. This imposes a periodic force on the conductors which is highly undesirable. It is therefore important for engineers to account for the possible effect of the wind loading when designing the power line. Investigations have shown that modeling the exact dynamic behaviour of a conductor is very difficult. Based on this fact, getting the exact analytical solution to conductor vibration is difficult, which is almost impossible, hence the numerical approximation becomes an option. This paper presents the developed finite element method used to analyse the dynamic behaviour of transmission line conductors. The developed FEM (finite element method) is implemented on MATLAB. The numerical analysis using MATLAB that is presented in this paper is used to simulate the response of the conductor when subjected to external loading in the time domain. The simulation is used to analyse the transverse vibration of the conductor. The formulation of the stiffness matrix and load vector is done and the results obtained are used to evaluate the conductor's internal energy dissipation. This finite element solution is compared with the results documented in literature. This numerical simulation is also used to investigate the effects of varying the axial tension on energy dissipation within the strands. Hence, this evolved in physically appropriate energy characterization process that can be used to evaluate the conductor self-damping with respect to line contact.