期刊文献+
共找到3,073篇文章
< 1 2 154 >
每页显示 20 50 100
Assessment of liver ablation using cone beam computed tomography 被引量:6
1
作者 Mohamed Abdel-Rehim Maxime Ronot +1 位作者 Annie Sibert Valérie Vilgrain 《World Journal of Gastroenterology》 SCIE CAS 2015年第2期517-524,共8页
AIM: To investigate the feasibility and accuracy of cone beam computed tomography(CBCT) in assessing the ablation zone after liver tumor ablation.METHODS: Twenty-three patients(17 men and 6 women, range: 45-85 years o... AIM: To investigate the feasibility and accuracy of cone beam computed tomography(CBCT) in assessing the ablation zone after liver tumor ablation.METHODS: Twenty-three patients(17 men and 6 women, range: 45-85 years old, mean age 65 years) with malignant liver tumors underwent ultrasoundguided percutaneous tumor ablation [radiofrequency(n = 14), microwave(n = 9)] followed by intravenous contrast-enhanced CBCT. Baseline multidetector computed tomography(MDCT) and peri-procedural CBCT images were compared. CBCT image quality was assessed as poor, good, or excellent. Image fusion was performed to assess tumor coverage, and quality of fusion was rated as bad, good, or excellent. Ablation zone volumes on peri-procedural CBCT and post-procedural MDCT were compared using the nonparametric paired Wilcoxon t-test.RESULTS: Rate of primary ablation effectiveness was 100%. There were no complications related to ablation. Local tumor recurrence and new liver tumors were found 3 mo after initial treatment in one patient(4%). The ablation zone was identified in 21/23(91.3%) patients on CBCT. The fusion of baseline MDCT and peri-procedural CBCT images was feasible in all patients and showed satisfactory tumor coverage(at least 5-mm margin). CBCT image quality was poor, good, and excellent in 2(9%), 8(35%), and 13(56%), patients respectively. Registration quality between periprocedural CBCT and post-procedural MDCT images was good to excellent in 17/23(74%) patients. The median ablation volume on peri-procedural CBCT and post-procedural MDCT was 30 cm3(range: 4-95 cm3) and 30 cm3(range: 4-124 cm3), respectively(P-value > 0.2). There was a good correlation(r = 0.79) between the volumes of the two techniques. CONCLUSION: Contrast-enhanced CBCT after tumor ablation of the liver allows early assessment of the ablation zone. 展开更多
关键词 Ablation cone beam COMPUTED tomography LIVER Malig
下载PDF
Use of cone beam computed tomography in periodontology 被引量:9
2
作者 Buket Acar Kivan Kamburoglu 《World Journal of Radiology》 CAS 2014年第5期139-147,共9页
Diagnosis of periodontal disease mainly depends on clinical signs and symptoms. However, in the case of bone destruction, radiographs are valuable diagnostic tools as an adjunct to the clinical examination. Two dimens... Diagnosis of periodontal disease mainly depends on clinical signs and symptoms. However, in the case of bone destruction, radiographs are valuable diagnostic tools as an adjunct to the clinical examination. Two dimensional periapical and panoramic radiographs are routinely used for diagnosing periodontal bone levels. In two dimensional imaging, evaluation of bone craters, lamina dura and periodontal bone level is limited by projection geometry and superpositions of adjacent anatomical structures. Those limitations of 2D radiographs can be eliminated by three-dimensional imaging techniques such as computed tomography. Cone beam computed tomography(CBCT) generates 3D volumetric images and is also commonly used in dentistry. All CBCT units provide axial, coronal and sagittal multi-planar reconstructed images without magnification. Also, panoramic images without distortion and magnification can be generated with curved planar reformation. CBCT displays 3D images that are necessary for the diagnosis of intra bony defects, furcation involvements and buccal/lingual bone destructions. CBCT applications provide obvious benefits in periodontics, however; it should be used only in correctindications considering the necessity and the potential hazards of the examination. 展开更多
关键词 cone beam COMPUTED tomography PERIODONTOLOGY RADIOLOGY DENTISTRY ORAL diagnosis
下载PDF
Impacted Lower Third Molar Fused with a Supernumerary Tooth—Diagnosis and Treatment Planning Using Cone-Beam Computed Tomography 被引量:11
3
作者 Osny Ferreira-Junior Luciana Dorigatti de .&.Aila +3 位作者 Marcelo Bonifacio da Silva Sampieri Eduardo Dias- Ribeiro Wei-liang Chen Song Fan 《International Journal of Oral Science》 SCIE CAS CSCD 2009年第4期224-228,共5页
This paper reported a case of fusion between an impacted third molar and a supernumerary tooth, in which a surgical intervention was carried out, with the objective of removing the dental elements. The panoramic radio... This paper reported a case of fusion between an impacted third molar and a supernumerary tooth, in which a surgical intervention was carried out, with the objective of removing the dental elements. The panoramic radiography was complemented by the Donovan's radiographic technique; but because of the proximity of the dental element to the mandibular ramus, it was not possible to have a final fusion diagnosis. Hence, the Cone-Beam Computed Tomography―which provides precise threedimensional information―was used to determinate the fusion diagnosis and also to help in the surgical planning. In this case report we observed that the periapical, occlusal and panoramic were not able to show details which could only be examined through the cone-beam computed tomography. 展开更多
关键词 口腔科学 磨牙 临床 护理
下载PDF
Three-dimensional Localization of Impacted Canines and Root Resorption Assessment Using Cone Beam Computed Tomography 被引量:5
4
作者 Eyad Almuhtaseb 毛靖 +2 位作者 Derek Mahony Rawan Bader 张智星 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2014年第3期425-430,共6页
The purpose of this study was to develop a new way to localize the impacted canines from three dimensions and to investigate the root resorption of the adjacent teeth by using cone beam computed tomography(CBCT). Fort... The purpose of this study was to develop a new way to localize the impacted canines from three dimensions and to investigate the root resorption of the adjacent teeth by using cone beam computed tomography(CBCT). Forty-six patients undergoing orthodontic treatments and having impacted canines in Tongji Hospital were examined. The images of CBCT scans were obtained from KaVo 3D exam vision. Angular and linear measurements of the cusp tip and root apex according to the three planes(mid-sagittal, occlusal and frontal) have been taken using the cephalometric tool of the InVivo Dental Anatomage Version 5.1.10. The measurements of the angular and linear coordinates of the maxillary and mandibular canines were obtained. Using this technique the operators could envision the location of the impacted canine according to the three clinical planes. Adjacent teeth root resorption of 28.26 % was in the upper lateral incisors while 17.39% in upper central incisors, but no lower root resorption was found in our samples. Accurate and reliable localization of the impacted canines could be obtained from the novel analysis system, which offers a better surgical and orthodontic treatment for the patients with impacted canines. 展开更多
关键词 三维定位 锥束CT 吸收 牙根 评估 线性测量 CT扫描 3D视觉
下载PDF
Transcatheter arterial chemoembolization combined with simultaneous cone beam computed tomography-guided multipolar microwave ablation for massive hepatocellular carcinoma(≥10 cm):Safety and primary clinical results 被引量:2
5
作者 Xiongying Jiang Xue Han +6 位作者 Tianqi Zhang Zhimei Huang Jingxian Shen Yajun Bo Guiqun Chen Minshan Chen Jinhua Huang 《Journal of Interventional Medicine》 2019年第2期65-68,共4页
Purpose:To explore the safety and clinical efficacy of transcatheter arterial chemoembolization(TACE)combined with simultaneous cone beam computed tomography(CBCT)-guided multipolar microwave ablation(MWA)in the treat... Purpose:To explore the safety and clinical efficacy of transcatheter arterial chemoembolization(TACE)combined with simultaneous cone beam computed tomography(CBCT)-guided multipolar microwave ablation(MWA)in the treatment of massive hepatocellular carcinoma(HCC).Materials and methods:Records of nine patients who underwent TACE combined with simultaneous CBCT-guided multipolar MWA for massive HCC,between January and June 2015,were retrospectively reviewed.Technical success rate,blood levels of liver function indicators,complications,and tumor response one month after treatmentwere investigated.Results:The technical success rate of TACE combined with simultaneous MWA was 100%.The mean procedure time was 195.0 min(range,125-350 min),the mean hospital stay after the treatment was 4.0±1.0 days(range,3-7 days),and no serious complications occurred.Minor complications were experienced by some patients but were relieved after conservative treatment.One month after treatment,enhanced CT revealed a complete response rate of 66.7%(6/9),a partial response rate of 22.2%(2/9),and a stable disease rate of 11.1%(1/9).Mild and reversible injury of liver function occurred in these patients.Conclusion:TACE combined with simultaneous CBCT-guided MWA for massive HCC was feasible and safe,and yielded a high response rate. 展开更多
关键词 cone beam CT SIMULTANEOUS Microwave ablation MASSIVE HEPATOCELLULAR carcinoma
下载PDF
Cone beam computed tomographic analyses of alveolar bone anatomy at the maxillary anterior region in Chinese adults 被引量:15
6
作者 Zhixuan Zhou Wu Chen +3 位作者 Ming Shen Chao Sun Jun Li Ning Chen 《The Journal of Biomedical Research》 CAS 2014年第6期498-505,共8页
To provide an anatomical basis for clinical implant esthetics,we evaluated the morphology of the nasopalatine canal(NPC) and analyzed labial and interproximal bone anatomy at the maxillary anterior region.We sought to... To provide an anatomical basis for clinical implant esthetics,we evaluated the morphology of the nasopalatine canal(NPC) and analyzed labial and interproximal bone anatomy at the maxillary anterior region.We sought to investigate the effect of maxillary protrusion and tooth labiolingual inclination on labial bone anatomy in Chinese adults.Three dimensional(3D) images were reconstructed using cone-beam computed tomography(CBCT) images from 80 Chinese subjects and by SimPlant 11.04.The dimensions of the NPC,the thickness and profile of the labial bone,the width and height of the interproximal bone,angle sella-nasion-subspinale(SNA) and angle upper central incisor-nasion,subspinale(U1-NA) were measured.The incisive foramen of the NPC was markedly wider than its nasal foramen.The dimension of its labial bone wall demonstrated an increasing width from the crestal to apical measurements.The labial bone at the maxillary anterior region was rather thin,especially at 3 mm below the cemento-enamel junction(CEJ) and the mid-root level;the profile of the labial bone was more curved at the central incisor,and the interproximal bone became wider and shorter posteriorly.There were significant relationships between maxillary protrusion and labial bone profile,tooth labiolingual inclination and labial bone thickness(P < 0.02).To achieve optimal esthetic outcome of implant,bone augmentation is necessary at the maxillary anterior region.For immediate or early placement at the maxillary anterior region,the implant should be located palatally to reduce labial bone resorption and marginal recession;its apex should be angulated palatally to avoid labial perforation at the apical region.To protect the NPC,implants at the central incisor region should be placed away from NPC. 展开更多
关键词 计算机断层摄影 解剖学 成年人 中国 全国人民代表大会 锥体 图像重建 NPC
下载PDF
Applied Anatomic Site Study of Palatal Anchorage Implants Using Cone Beam Computed Tomography 被引量:7
7
作者 Ren-fa Lai Hui Zou +1 位作者 Wei-dong Kong Wei Lin 《International Journal of Oral Science》 SCIE CAS CSCD 2010年第2期98-104,共7页
Aim The purpose of this study was to conduct quantitative research on bone height and bone mineral density of palatal implant sites for implantation, and to provide reference sites for safe and stable palatal implants... Aim The purpose of this study was to conduct quantitative research on bone height and bone mineral density of palatal implant sites for implantation, and to provide reference sites for safe and stable palatal implants. Methodology Three-dimensional reformatting images were reconstructed by cone beam computed tomography (CBCT) in 34 patients, aged 18 to 35 years, using EZ Implant software. Bone height was measured at 20 sites of interest on the palate. Bone mineral density was measured at the 10 sites with the highest implantation rate, classified using K-mean cluster analysis based on bone height and bone mineral density. Results According to the cluster analysis, 10 sites were classified into three clusters. Significant differences in bone height and bone mineral density were detected between these three clusters (P<0.05). The greatest bone height was obtained in cluster 2, followed by cluster 1 and cluster 3. The highest bone mineral density was found in cluster 3, followed by cluster 1 and cluster 2. Conclusion CBCT plays an important role in pre-surgical treatment planning. CBCT is helpful in identifying safe and stable implantation sites for palatal anchorage. 展开更多
关键词 腭骨 植入体 骨密度 定量研究
下载PDF
Effects of Irregular Respiratory Motion on the Positioning Accuracy of Moving Target with Free Breathing Cone-Beam Computerized Tomography 被引量:1
8
作者 Xiang Li Tianfang Li +9 位作者 Ellen Yorke Gig Mageras Xiaoli Tang Maria Chan Weijun Xiong Marsha Reyngold Richard Gewanter Abraham Wu John Cuaron Margie Hunt 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2018年第2期173-183,共11页
For positioning a moving target, a maximum intensity projection (MIP) or average intensity projection (AIP) image derived from 4DCT is often used as the reference image which is matched to free breathing cone-beam CT ... For positioning a moving target, a maximum intensity projection (MIP) or average intensity projection (AIP) image derived from 4DCT is often used as the reference image which is matched to free breathing cone-beam CT (FBCBCT) before treatment. This method can be highly accurate if the respiratory motion of the patient is stable. However, a patient’s breathing pattern is often irregular. The purpose of this study is to investigate the effects of irregular respiration on positioning accuracy for a moving target aligned with FBCBCT. Nine patients’ respiratory motion curves were selected to drive a Quasar motion phantom with one embedded cubic and two spherical targets. A 4DCT of the phantom was acquired on a CT scanner (Philips Brilliance 16) equipped with a Varian RPM system. The phase binned 4DCT images and the corresponding MIP and AIP images were transferred into Eclipse for analysis. FBCBCTs of the phantom driven by the same respiratory curves were also acquired on a Varian TrueBeam and fused such that both CBCT and MIP/AIP images share the same target zero positions. The sphere and cube volumes and centroid differences (alignment error) determined by MIP, AIP and FBCBCT images were calculated, respectively. Compared to the volume determined by MIP, the volumes of the cube, large sphere, and small sphere in AIP and FBCBCT images were smaller. The alignment errors for the cube, large sphere and small sphere with center to center matches between MIP and FBCBCT were 2.5 ± 1.8 mm, 2.4 ± 2.1 mm, and 3.8 ± 2.8 mm, and the alignment errors between AIP and FBCBCT were 0.5 ± 1.1 mm, 0.3 ± 0.8 mm, and 1.8 ± 2.0 mm, respectively. AIP images appear to be superior reference images to MIP images. However, irregular respiratory pattern could compromise the positioning accuracy, especially for smaller targets. 展开更多
关键词 cone beam COMPUTERIZED tomography RESPIRATORY Motion Effect
下载PDF
Bone mineral density in cone beam computed tomography:Only a few shades of gray 被引量:3
9
作者 Marcio José da Silva Campos Thainara Salgueiro de Souza +2 位作者 Sergio Luiz Mota Júnior Marcelo Reis Fraga Robert Willer Farinazzo Vitral 《World Journal of Radiology》 CAS 2014年第8期607-612,共6页
Cone beam computed tomography(CBCT) has often been used to determine the quality of craniofacial bone structures through the determination of mineral density, which is based on gray scales of the images obtained. Howe... Cone beam computed tomography(CBCT) has often been used to determine the quality of craniofacial bone structures through the determination of mineral density, which is based on gray scales of the images obtained. However, there is no consensus regarding the accuracy of the determination of the gray scales in these exams. This study aims to provide a literature review concerning the reliability of CBCT to determine bone mineral density. The gray values obtained with CBCT show a linear relationship with the attenuation coefficients of the materials, Hounsfield Units values obtained with medical computed tomography, and density values from dual energy X-ray absorciometry. However, errors are expected when CBCT images are used to define the quality of the scanned structures be-cause these images show inconsistencies and arbitrari-ness in the gray values, particularly when related to abrupt change in the density of the object, X-ray beam hardening effect, scattered radiation, projection data discontinuity-related effect, differences between CBCTdevices, changes in the volume of the field of view(FOV), and changes in the relationships of size and position between the FOV and the object evaluated. A few methods of mathematical correction of the gray scales in CBCT have been proposed; however, they do not generate consistent values that are independent of the devices and their configurations or of the scanned objects. Thus, CBCT should not be considered the ex-amination of choice for the determination of bone and soft tissue mineral density at the current stage, par-ticularly when values obtained are to be compared to predetermined standard values. Comparisons between symmetrically positioned structures inside the FOV and in relation to the exomass of the object, as it occurs with the right and left sides of the skull, seem to be viable because the effects on the gray scale in the re-gions of interest are the same. 展开更多
关键词 tomography cone-beam COMPUTED tomography Bone mineral density REPRODUCIBILITY of results
下载PDF
Clinical Endodontic Applications of Cone Beam-Computed Tomography in Modern Dental Practice 被引量:1
10
作者 Johnah C. Galicia Jeffrey Kawilarang Peter Z. Tawil 《Open Journal of Stomatology》 2017年第7期314-326,共13页
Nearly two decades since Cone Beam-Computed Tomography (CBCT) was introduced in dentistry, this technology has been proven to be a useful asset in modern dental practice. The information gleaned from a CBCT scan influ... Nearly two decades since Cone Beam-Computed Tomography (CBCT) was introduced in dentistry, this technology has been proven to be a useful asset in modern dental practice. The information gleaned from a CBCT scan influences treatment decisions and prognostication of challenging endodontic cases. The authors present six cases that utilized CBCT to diagnose vertical root fracture, to assess resorption, to guide the clinician in overcoming anatomical complexities, to hurdle diagnostic dilemmas and to perform pre-surgical evaluation. Initially, a thorough clinical assessment was performed;however, conventional periapical radiographs were not able to provide sufficient information to arrive at a definite diagnosis or a thorough treatment plan. CBCT was therefore deemed helpful for these cases. Clearly, there are advantages to using CBCT. With a better understanding of each case, the clinician can plan a definitive treatment plan and offer a clearer case prognosis to their patient. 展开更多
关键词 ENDODONTICS cone-beam COMPUTED tomography Case REPORTS RADIOGRAPHY
下载PDF
Improvements to conventional X-ray tube-based cone-beam computed tomography system 被引量:2
11
作者 Cui Zhang Xiao-Dong Pan +2 位作者 Hong-Jie Shang Yan-Hong Luo Gong-Ping Li 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第3期156-164,共9页
Conventional X-ray tube-based cone-beam computed tomography(CX-CBCT) systems have great potential in industrial applications. Such systems can rapidly obtain a three-dimensional(3D) image of an object.Conventional X-r... Conventional X-ray tube-based cone-beam computed tomography(CX-CBCT) systems have great potential in industrial applications. Such systems can rapidly obtain a three-dimensional(3D) image of an object.Conventional X-ray tubes fulfill the requirements for industrial applications, because of their high tube voltage and power. Continuous improvements have been made to CX-CBCT systems, such as imaging time shortening,acquisition strategy optimization, and imaging software development, etc. In this study, a CX-CBCT system is developed. Additionally, some improvements to the CX-CBCT system are proposed based on the hardware conditions of the X-ray tube and detector. A near-detector(ND)geometry condition is employed to obtain a sharper image and larger detection area. An improved acquisition strategy is proposed to simplify operations and reduce total imaging time. In the ND geometry condition, a simplified method called FBP slice stacking(SS-FBP) is proposed, which can be applied to 3D image reconstruction. SS-FBP is timesaving relative to traditional methods. Furthermore, imaging software for the CX-CBCT system is developed in the MATLAB environment. Several imaging experiments were performed. The results suggest that the CX-CBCT system works properly, and that the above improvements are feasible and practical. 展开更多
关键词 cone-beam CT CONVENTIONAL X-RAY TUBE NONDESTRUCTIVE testing X-RAY imaging
下载PDF
Genial tubercles: Morphological study of the controversial anatomical landmark using cone beam computed tomography
12
作者 Yasser A Araby Ahmed A Alhirabi Abdelaleem H Santawy 《World Journal of Radiology》 CAS 2019年第7期94-101,共8页
BACKGROUND Identification of the morphology of the genial tubercles (GTs) is valuable for different dental applications. The morphological pattern of the GTs is still controversial, and therefore, the study of its mor... BACKGROUND Identification of the morphology of the genial tubercles (GTs) is valuable for different dental applications. The morphological pattern of the GTs is still controversial, and therefore, the study of its morphology using cone beam computed tomography (CBCT) plays a valuable role in resolving the controversy. AIM To assess the morphological pattern, dimensions and position of the GTs using CBCT among a selected Saudi population. METHODS CBCT records of 155 Saudi subjects (49 female and 106 male) were used to assess the pattern and size of the GTs and to determine the distance from the apices of the lower central incisors to the superior border of the incisors (I-SGT) and the distance from the inferior border of the GTs to the menton (IGT-M). RESULTS The results of this study showed that the most common morphological pattern was of two superior GTs and a rough impression below them (36.8%), followed by two superior GTs and a median ridge representing fused inferior GTs below them (22.6%) and a single median eminence or projection (20%). The classically described pattern, of two superior and two inferior GTs placed one above the other, was found in only 14.2% of cases, while 6.4% of the studied cases had no GTs. The mean width and height were 6.23 ± 1.93 mm and 6.67 ± 3.04 mm, respectively, while the mean I-SGT and IGT-M measurements were 8.26 ± 2.7 mm and 8.13 ± 3.07 mm, respectively. CONCLUSION The GTs are a controversial anatomical landmark with wide variation in their morphological pattern. The most common pattern among the studied Saudi sample was of two superior GTs and a rough impression below them, and there were no significant differences between males and females. 展开更多
关键词 Genial tubercles cone beam COMPUTED tomography MORPHOLOGICAL analysis MANDIBLE ANATOMICAL LANDMARK
下载PDF
Analysis of Dose Calculation Accuracy in Cone Beam Computed Tomography with Various Amount of Scattered Photon Contamination
13
作者 Keisuke Usui Koichi Ogawa Keisuke Sasai 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2017年第3期233-251,共19页
Cone-beam computed tomography (CBCT) images have inaccurate CT numbers because of scattered photons. Thus, quantitative analysis of scattered photons that affect an electron density (ED) curve and calculated doses may... Cone-beam computed tomography (CBCT) images have inaccurate CT numbers because of scattered photons. Thus, quantitative analysis of scattered photons that affect an electron density (ED) curve and calculated doses may be effective information to achieve CBCT-based radiation treatment planning. We quantitatively evaluated the effect of scattered photons on the accuracy of dose calculations from a lung image. The Monte Carlo method was used to calculate CBCT projection data, and we made two calibration curves for conditions with or without scattered photons. Moreover, we applied cupping artifact correction and evaluated the effects on image uniformity and dose calculation accuracy. Dose deviations were compared with those of conventional CT in conventional and volumetric intensity modulated arc therapy (VMAT) planning by using γ analysis and dose volume histogram (DVH) analysis. We found that cupping artifacts contaminated the scattered photons, and the γ analysis showed that the dose distribution was most decreased for a scattered photon ratio of 40%. Cupping artifact correction significantly improved image uniformity;therefore, ED curves were near ideal, and the pass rate results were significantly higher than those associated with the scattered photon effect in 65.1% and 78.4% without correction, 99.5% and 97.7% with correction, in conventional and VMAT planning, respectively. In the DVH analysis, all organ dose indexes were reduced in the scattered photon images, but dose index error rates with cupping artifact correction were improved within approximately 10%. CBCT image quality was strongly affected by scattered photons, and the dose calculation accuracy based on the CBCT image was improved by removing cupping artifacts caused by the scattered photons. 展开更多
关键词 cone beam COMPUTED tomography SCATTERED PHOTON Dose Calculation CUPPING ARTIFACT
下载PDF
Efficacy of Daily Cone-Beam Computed Tomography as Part of a Rescan Protocol for Large Offset to Reduce the Inter-Fractional Motion of the Prostate
14
作者 Shinsaku Yamaguchi Takayuki Ohguri +7 位作者 Hajime Imada Katsuya Yahara Hiroyuki Narisada Satoshi Iwasaki Toshihiro Onoda Yuta Ezaki Eiji Hamada Yukunori Korogi 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2014年第4期193-200,共8页
Purpose: To prospectively analyze the inter-fractional motion of the prostate in patients with prostate cancer treated with intensity-modulated radiation therapy (IMRT) using image-guided radiotherapy (IGRT) with dail... Purpose: To prospectively analyze the inter-fractional motion of the prostate in patients with prostate cancer treated with intensity-modulated radiation therapy (IMRT) using image-guided radiotherapy (IGRT) with daily cone-beam computed tomography (CBCT) as part of a rescan protocol for large offset, and to evaluate the efficacy of our protocol. Materials and Methods: Eligible patients were treated with the following protocol: 1) magnesium oxide and dimethylpolysiloxane were administered to ensure that patients had regular bowel movements;2) the patients were instructed to have an appropriately distended bladder during the planning CT and daily irradiation;3) the daily CBCT image was fused with the planning CT image using the prostate outline;and 4) if large offset was recognized, a rescan CBCT image was obtained after appropriate countermeasures, such as the discharge of gas and defecation, and re-registration was performed. Three shifts for the inter-fractional motion of the prostate were analyzed, in the fractions which needed the CBCT rescan;the displacement data after the final rescan were used. Results: Sixty-one patients were eligible, and a total of 2302 fractions were available for the analysis. Rescans of the CBCT for large offset were performed in 113 (5%) of the 2302 fractions. After the first rescan, the large offset was resolved in 106 (94%) of the 113 fractions. Excessive rectal gas was the reason for the large offset in 94 (83%) of the 113 fractions. The total mean and standard deviation of the inter-fractional motion of the prostate in the AP, LR, and SI directions were 1.1 ± 2.4, -0.1 ± 2.3, and 0.7 ± 3.0 mm, respectively. Conclusion: Large offset was recognized in 5% of all fractions. Daily CBCT with our rescan protocol could resolve the large offset, which was mainly caused by excessive rectal gas, and it may therefore be promising to reduce the inter-fractional motion of the prostate. 展开更多
关键词 INTENSITY-MODULATED Radiotherapy PROSTATE Cancer DAILY cone beam Computed tomography Inter-Fractional MOTION
下载PDF
Knowledge and Practices of Dentists, Oral and Maxillofacial Surgeons of Cone Beam Computed Tomography (CBCT) and the Dentascanner in a Low Income Country: Case of Togo
15
作者 Mazamaesso Tchaou Haréfétéguéna Bissa +7 位作者 Plaodesina Essobozou Pegbessou Abdoulatif Amadou Bidamin N’timon Mawuena Dansou Abdoul-Razakou Adam Lantam Sonhaye Lama-Kegdigoma Agoda-Koussema Komlan Adjenou 《Open Journal of Radiology》 2017年第1期1-8,共8页
Background: In dental-maxillofacial imaging, 3D sectional imaging progressively replaces conventional 2D imaging in developed countries. They are based specially on Computed tomography (CT-Scan), with the Dentascan ap... Background: In dental-maxillofacial imaging, 3D sectional imaging progressively replaces conventional 2D imaging in developed countries. They are based specially on Computed tomography (CT-Scan), with the Dentascan application and cone beam computed tomography (CBCT). In developing countries those technics are newly introduced. Aim: This study aimed at studying the knowledge and practices of dentist and oral and maxillofacial surgeons on sectional imaging such as Dentascan and Cone Beam Computed Tomography (CBCT). Materials and Methods: We conducted an anonymous survey among dentists and oral maxillofacial surgeons in Togo over one month. Results: The response rate was 78.79% (27/33). They were mainly male sex (sex ratio of 2.25 men for one woman). They were aged between 27 and 71 years old with an average of 49.69 years old. The majority (61.54%) had a professional experience over 20 years. The majority of respondents (65.38%) believed their level of knowledge about dental x-Ray was poor. Half of them (50%) confirmed that they had never asked for a Dentascan, and 15.38% asked from time to time for it and only two (7.69%) asked often for this test. 96.15% confirm they have no knowledge of the Dentascan. Regarding the CBCT, 84.62% didn’t ask for it because this technique did not exist in Togo before. 69.20% of respondents confessed to be interested in continuing training on sectional imaging. Conclusion: This study shows that sectional imaging is very little used by oral and dental practitioners in Togo because of the ignorance of the new techniques and the absence of the CBCT. It is therefore necessary to promote the teaching of the new technique of sectional imaging in the training syllabus of oral and dental specialists and to initiate continuing medical training. 展开更多
关键词 KNOWLEDGE Practice Dentascan cone beam Computed tomography (CBCT) DENTIST Oral and Maxillofacial Surgeon TOGO
下载PDF
Cone beam computed tomographic evaluation of pharyngeal airway in North Indian children with different skeletal patterns
16
作者 Anuraj Singh Kochhar Maninder Singh Sidhu +4 位作者 Ritasha Bhasin Gulsheen Kaur Kochhar Himanshu Dadlani Jagpreet Sandhu Bobby Virk 《World Journal of Radiology》 2021年第2期40-52,共13页
BACKGROUND In growing patients with skeletal discrepancies,early assessment of functional factors can be vital for the restoration of normal craniofacial growth.AIM To compare airway volumes in patients with mandibula... BACKGROUND In growing patients with skeletal discrepancies,early assessment of functional factors can be vital for the restoration of normal craniofacial growth.AIM To compare airway volumes in patients with mandibular retrognathism with the normal anteroposterior skeletal relationship,thereby assessing the association between cephalometric variables and airway morphology.METHODS Cone-beam computed tomography volume scans,and lateral cephalograms,3-dimensional airway volume and cross-sectional areas of 120 healthy children(54 boys and 66 girls mean age 15.19±1.28)which were done for orthodontic assessment were evaluated.The subjects were divided into 2 groups based on the angle formed between point A,Nasion and point B(ANB)values and cephalometric variables(such as anterior and posterior facial height,gonial angle etc.)airway volumes,and cross-sectional measurements were compared using independent t tests.Pearson’s correlation coefficient test was used to detect any relationship of different parts of the airway and between airway volume and 2-dimensional cephalometric variables.RESULTS Means and standard deviations for cephalometric,cross-sectional,and volumetric variables were compared.ANB,mandibular body length and facial convexity were statistically highly significant(P<0.01)whereas condylion to point A,nasal airway and total airway volume(P<0.05)were statistically significant.The nasal airway volume and the superior pharyngeal airway volume had a positive correlation(P<0.01),nasal airway was correlated to middle(P<0.05)and total airway superior had a relation with middle(P<0.05),inferior and total airway(P<0.05),middle was related to all other airways;inferior was also related to all the airways except nasal.Lateral cephalometric values were positively correlated with the airway volume with Frankfurt Mandibular Plane Angle and facial convexity showed significant correlations with total airway volume(P<0.05).Additionally,ANB angle was significantly correlated with total airway volume and superior airway(P<0.05).CONCLUSION The mean total airway volume in patients with retrognathic mandible was significantly smaller than that of patients with a normal mandible. 展开更多
关键词 Pharyngeal airway cone beam computed tomography Skeletal pattern MALOCCLUSION Retrognathic Airway volume
下载PDF
Practical limitations of cone-beam computed tomography in 3D cephalometry
17
作者 Janalt Damstra Zacharias Fourie 《上海口腔医学》 CAS CSCD 2011年第6期662-668,共7页
3D cone beam computed tomography(CBCT) images offer a unique and new appreciation of the anatomical structures and underlying anomalies not possible with conventional radiographs.However,in almost all aspects of CBCT ... 3D cone beam computed tomography(CBCT) images offer a unique and new appreciation of the anatomical structures and underlying anomalies not possible with conventional radiographs.However,in almost all aspects of CBCT imaging,from utilization to application,inherent limitations and pitfalls exist.Importantly,these inherent limitations and pitfalls have practical implications which need to be addressed before the potential of this technology can be fully realized.The purpose of this review was to explore the current limitations and pitfalls associated with CBCT imaging to allow for better and more accurate understanding of the possibilities this imaging modality could offer,particularly pertaining to 3D cephalometry. 展开更多
关键词 三维锥束CT CT成像技术 成像方式 测量方法
下载PDF
Strategies for Segmenting the Upper Airway in Cone-Beam Computed Tomography (CBCT) Data
18
作者 N. Kabaliuk A. Nejati +3 位作者 C. Loch D. Schwass J. E. Cater M. C. Jermy 《Open Journal of Medical Imaging》 2017年第4期196-219,共24页
The wide availability, low radiation dose and short acquisition time of Cone-Beam CT (CBCT) scans make them an attractive source of data for compiling databases of anatomical structures. However CBCT has higher noise ... The wide availability, low radiation dose and short acquisition time of Cone-Beam CT (CBCT) scans make them an attractive source of data for compiling databases of anatomical structures. However CBCT has higher noise and lower contrast than helical slice CT, which makes segmentation more challenging and the optimal methods are not yet known. This paper evaluates several methods of segmenting airway geometries (nares, nasal cavities and pharynx) from typical dental quality head and neck CBCT data. The nasal cavity has narrow and intricate passages and is separated from the paranasal sinuses by thin walls, making it is susceptible to either over- or under-segmentation. The upper airway was split into two: the nasal cavity and the pharyngeal region (nasopharynx to larynx). Each part was segmented using global thresholding, multi-step level-set, and region competition methods (the latter using thresholding, clustering and classification initialisation and edge attraction techniques). The segmented 3D surfaces were evaluated against a reference manual segmentation using distance-, overlap- and volume-based metrics. Global thresholding, multi-step level-set, and region competition all gave satisfactory results for the lower part of the airway (nasopharynx to larynx). Edge attraction failed completely. A semi-automatic region-growing segmentation with multi-thresholding (or classification) initialization offered the best quality segmentation. With some minimal manual editing, it resulted in an accurate upper airway model, as judged by the similarity and volumetric indices, while being the least time consuming of the semi-automatic methods, and relying the least on the operator’s expertise. 展开更多
关键词 cone beam CT CBCT Segmentation UPPER AIRWAY NASAL Cavity PHARYNGEAL AIRWAY
下载PDF
Application of cone beam computed tomography in facial imaging science
19
作者 Zacharias Fourie Janalt Damstra 《上海口腔医学》 CAS CSCD 北大核心 2012年第2期220-231,共12页
Facial imaging is used to study the facial shapeand its developmental changes over time.This isimportant to diagnose acquired malformations,to studynormal and abnormal growth and to differentiatebetween the results of... Facial imaging is used to study the facial shapeand its developmental changes over time.This isimportant to diagnose acquired malformations,to studynormal and abnormal growth and to differentiatebetween the results of treatment and normal growth,and to validate facial recognition.The two mainmethods to study and record facial imaging are bymeans of cephalometry and anthropometry[1].Cephalometrics is the scientific study of themeasurements of the 展开更多
关键词 口腔医学 临床分析 患者 症状
下载PDF
Scattering correction method for panel detector based cone beam computed tomography system
20
作者 贾鹏翔 张峰 +1 位作者 闫镔 包尚联 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第8期609-613,共5页
A scattering correction method for a panel detector based cone beam computed tomography system is presented. First,the x-ray spectrum of the system is acquired by using the Monte Carlo simulation method.Secondly,scatt... A scattering correction method for a panel detector based cone beam computed tomography system is presented. First,the x-ray spectrum of the system is acquired by using the Monte Carlo simulation method.Secondly,scattered photon distribution is calculated and stored as correction matrixes by using the Monte Carlo simulation method according to scanned objects and computed tomography system specialties.Thirdly,scattered photons are removed from projection data by correction matrixes.A comparison of reconstruction image between before and after scattering correction demonstrates that the scattering correction method is effective for the panel detector based cone beam computed tomography system. 展开更多
关键词 平板探测器 CT系统 散射光子 校正方法 锥束 蒙特卡罗模拟方法 校正矩阵 X射线谱
下载PDF
上一页 1 2 154 下一页 到第
使用帮助 返回顶部