期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Experimental study of single-translated fieldreversed configuration in KMAX
1
作者 Hui LIAO Chaoqi HU +2 位作者 Yilin LI Baoming REN Xuan SUN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第9期37-44,共8页
For collisional merging fleld-reversed conflgurations(FRCs),it is desired to have both FRCs tuned to be approximately the same,as well as to optimize each FRC to have high temperature and high translation speed so as ... For collisional merging fleld-reversed conflgurations(FRCs),it is desired to have both FRCs tuned to be approximately the same,as well as to optimize each FRC to have high temperature and high translation speed so as to retain most of the equilibrium flux after traveling a distance to the middle plane for merging.The present study reports the experimental study of a single-translated FRC in the KMAX-FRC device with various diagnostics,including a triple probe,a bolometer,several magnetic probe arrays,and a novel 2 D internal magnetic probe array.According to the measurements conducted in the present study,a maximum toroidal magnetic fleld equal to~1/3 of the external magnetic fleld inside the FRC separatrix radius is observed,and the typical parameters of a single-translated FRC near the device’s mid-plane are ne~(2–4)×10^(19)m^(-3),T_(e)~8e V,T_(i)~5 e V,r_(s)~0.2 m,l_(s)~0.6 m andφ_(()p(RR))~0.2 m Wb.The 2 D magnetic topology measurement revealed,for the flrst time,the time evolution of the overall internal magnetic flelds of a single-translated FRC,and an optimized operation regime is given in the paper. 展开更多
关键词 fleld-reversed conflguration FRC formation FRC translation probe measurement
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部