期刊文献+
共找到309篇文章
< 1 2 16 >
每页显示 20 50 100
Numerical Studies of Divided Aperture Techniques in Confocal System
1
作者 Haonan Lai 《Journal of Power and Energy Engineering》 2019年第11期42-46,共5页
This paper performs a numerical study of the imaging process in confocal microscopy. We simulate the imaging result using Fresnel diffraction formula. We also consider the divided aperture technique in confocal system... This paper performs a numerical study of the imaging process in confocal microscopy. We simulate the imaging result using Fresnel diffraction formula. We also consider the divided aperture technique in confocal system. Different aperture shapes were varied to achieve best performance in terms of resolution and integrated intensity. Here, the D-shaped achieves the best performance in x-axis resolution, while the annular aperture shape is the worst for integrated intensity. We propose using different aperture shapes for various biomedical applications. 展开更多
关键词 confocal MICROSCOPY APERTURE RESOLUTION Integrated INTENSITY
下载PDF
Probe based confocal laser endomicroscopy of the pancreatobiliary system 被引量:6
2
作者 Majid A Almadi Helmut Neumann 《World Journal of Gastroenterology》 SCIE CAS 2015年第44期12696-12708,共13页
AIM:To review applications of confocal laser endomicroscopy(CLE) in pancreatobiliary lesions and studies that assessed training and interpretation of images. METHODS: A computerized literature search was performed usi... AIM:To review applications of confocal laser endomicroscopy(CLE) in pancreatobiliary lesions and studies that assessed training and interpretation of images. METHODS: A computerized literature search was performed using OVID MEDLINE, EMBASE, Cochrane library, and the ISI Web of Knowledge from 1980 to October 2014. We also searched abstracts from major meetings that included the Digestive Disease Week, Canadian Digestive Disease Week and the United European Gastroenterology Week using a combination of controlled vocabulary and text words related to p CLE, confocal, endomicroscopy, probe-based confocal laser endomicroscopy, and bile duct to identify reports of trials. In addition, recursive searches and crossreferencing was performed, and manual searches of articles identified after the initial search was also completed. We included fully published articles and those in abstract form. Given the relatively recent introduction of CLE we included randomized trials and cohort studies.R E S U LT S : In the evaluation of indeterminate pancreatobiliary strictures CLE with ERCP compared to ERCP alone can increase the detection of cancerous strictures with a sensitivity of(98% vs 45%) andhas a negative predictive value(97% vs 69%), but decreased the specificity(67% vs 100%) and the positive predictive value(71% vs 100%) when compared to index pathology. Modifications in the classification systems in indeterminate biliary strictures have increased the specificity of p CLE from 67% to 73%. In pancreatic cystic lesions there is a need to develop similar systems to interpret and characterize lesions based on CLE images obtained. The presence of superficial vascular network predicts serous cystadenomas accurately. Also training in acquiring and interpretation of images is feasible in those without any prior knowledge in CLE in a relatively simple manner and computer-aided diagnosis software is a promising innovation. CONCLUSION: The role of p CLE in the evaluation of pancreatobiliary disorders might be better suited for those with an intermediate and low probability. 展开更多
关键词 PROBE BASED confocal laser ENDOMICROSCOPY confocal
下载PDF
Real time detection of antibody-antigen interaction using a laser scanning confocal imaging-surface plasmon resonance system 被引量:4
3
作者 Zhang Hong-Yan Yang Li-Quan +5 位作者 Meng Lan Nie Jia-Cai Ning Ting-Yin Liu Wei-Min Sun Jia-Yu Wang Peng-Fei 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第2期224-228,共5页
A laser scanning confocal imaging-surface plasmon resonance (LSCI-SPR) instrument integrated with a wavelength-dependent surface plasmon resonance (SPR) sensor and a laser scanning confocal microscopy (LSCM) is ... A laser scanning confocal imaging-surface plasmon resonance (LSCI-SPR) instrument integrated with a wavelength-dependent surface plasmon resonance (SPR) sensor and a laser scanning confocal microscopy (LSCM) is built to detect the bonding process of human IgG and fluorescent-labeled affinity purified antibodies in real time. The shifts of resonant wavelength at different reaction time stages are obtained by SPR, corresponding well with the changes of the fluorescence intensity collected by using LSCM. The instrument shows the merits of the combination and complementation of the SPR and LSCM, with such advantages as quantificational analysis, high spatial resolution and real time monitor, which are of great importance for practical applications in biosensor and life science. 展开更多
关键词 laser scanning confocal imaging-surface plasmon resonance COMBINATION COMPLEMENTATION real time
下载PDF
Diagnosis of poorly differentiated adenocarcinoma of the stomach by confocal laser endomicroscopy:A case report 被引量:3
4
作者 Jia-Xin Lou Yong Wu +3 位作者 Muren Huhe Jing-Jie Zhang Dong-Wu Jia Zhen-Yu Jiang 《World Journal of Clinical Cases》 SCIE 2024年第8期1481-1486,共6页
BACKGROUND In recent years,confocal laser endomicroscopy(CLE)has become a new endoscopic imaging technology at the microscopic level,which is extensively performed for real-time in vivo histological examination.CLE ca... BACKGROUND In recent years,confocal laser endomicroscopy(CLE)has become a new endoscopic imaging technology at the microscopic level,which is extensively performed for real-time in vivo histological examination.CLE can be performed to distinguish benign from malignant lesions.In this study,we diagnosed using CLE an asymptomatic patient with poorly differentiated gastric adenocarcinoma.CASE SUMMARY A 63-year-old woman was diagnosed with gastric mucosal lesions,which may be gastric cancer,in the small curvature of the stomach by gastroscopy.She consented to undergo CLE for morphological observation of the gastric mucosa.Through the combination of CLE diagnosis and postoperative pathology,the intraoperative CLE diagnosis was considered to be reliable.According to our experience,CLE can be performed as the first choice for the diagnosis of gastric cancer.CONCLUSION CLE has several advantages over pathological diagnosis.We believe that CLE has great potential in the diagnosis of benign and malignant gastric lesions. 展开更多
关键词 confocal laser endomicroscopy Poorly differentiated gastric adenocarcinoma DIAGNOSIS Early stage Case report
下载PDF
THE PARALLEL CONFOCAL DETECTING SYSTEM USING OPTICAL FIBER PLATE
5
作者 朱升成 王昭 赵宏 《Journal of Pharmaceutical Analysis》 SCIE CAS 2005年第2期37-40,共4页
Objective Focusing on the problem such as slow scanning speed, complex system design and low light efficiency, a new parallel confocal 3D profile detecting method based on optical fiber technology, which realizes whol... Objective Focusing on the problem such as slow scanning speed, complex system design and low light efficiency, a new parallel confocal 3D profile detecting method based on optical fiber technology, which realizes whole-field confocal detecting, is proposed. Methods The optical fiber plate generates an 2D point light source array, which splits one light beam into N2 subbeams and act the role of pinholes as point source and point detecting to filter the stray light and reflect light. By introducing the construction and working principle of the multi-beam 3D detecting system, the feasibility is investigated. Results Experiment result indicates that the optical fiber technology is applicable in parallel confocal detecting. Conclusion The equipment needn't mechanical rotation. The measuring parameters that influence the detecting can easily be adapted to satisfy different requirments of measurement. Compared with the conventional confocal method, the parallel confocal detecting system using optical fiber plate is simple in the mechanism, the measuring field is larger and the speed is faster. 展开更多
关键词 confocal microscopy 3D profile parallel detecting optical fiber plate
下载PDF
Simultaneous Measurement of Neural Activities of Acute Mouse Hippocampal Slices Using Multi-Electrode Array System and Laser Confocal Calcium Imaging
6
作者 Yuuta Hamasaki Natsumi Haba +2 位作者 Naoki Iwata Yoshiki Uno Minoru Saito 《Journal of Behavioral and Brain Science》 2017年第2期68-78,共11页
Recently, non-invasive, real-time and multi-point measurement of neural activities has become possible by using a multi-electrode array (MEA). Another method for multi-point measurement is the fluorescent imaging tech... Recently, non-invasive, real-time and multi-point measurement of neural activities has become possible by using a multi-electrode array (MEA). Another method for multi-point measurement is the fluorescent imaging technique using voltage indicator dyes or calcium indicator dyes. Especially, calcium imaging using fluorescent calcium indicator dyes is often more useful, because they exhibit larger changes in the fluorescence intensity than voltage indicator dyes and their fluorescence changes can be detect easily. Additionally, calcium signals play key roles in the brain function, such as the long-term potentiation (LTP) in the hippocampus, and calcium imaging can be a powerful tool to elucidate the brain function. In this study, we constructed a measurement apparatus combining the MEA system and laser confocal calcium imaging and simultaneously measured electric signals and calcium signals in acute mouse hippocampal slices. The obtained results showed the availability of the present method. 展开更多
关键词 MULTI-ELECTRODE Array LASER confocal Calcium Imaging Hippocampus ACUTE SLICE Long-Term POTENTIATION
下载PDF
Research of Confocal Laser Induced Fluorescence Detection System for Micro-fluidic Chip
7
作者 FENG Jin-yuan WANG Xiu-hua ZHANG Hua-feng 《Semiconductor Photonics and Technology》 CAS 2007年第2期104-107,111,共5页
The characteristics such as signal noise ratio(SNR) and sensitivity of the fluorescence detection system for micro-fluidic chip influence the performance of the whole system extremely. The confocal laser induced flu... The characteristics such as signal noise ratio(SNR) and sensitivity of the fluorescence detection system for micro-fluidic chip influence the performance of the whole system extremely. The confocal laser induced fluorescence detection system is presented. Based on the debugging of optical and circuit modules, the results of detecting the samples are given and analyzed theoretically, and the improved project is put forward. 展开更多
关键词 micro-fluidic chip laser induced fluorescence detection SNR sensitivity confocal
下载PDF
THE CONFOCAL INVOLUTIVE SYSTEM AND THE INTEGRABILITY OF THE NONLINEARIZED LAX SYSTEMS FOR AKNS HIERARCHY
8
作者 马文秀 《Acta Mathematica Scientia》 SCIE CSCD 1990年第3期241-249,共9页
The completely integrable Hamiltonian systems generated by the general confocal involutive system are proposed. It is proved that the nonlinearized eigenvalue problem for AKNS hierarchy is such an integrable system an... The completely integrable Hamiltonian systems generated by the general confocal involutive system are proposed. It is proved that the nonlinearized eigenvalue problem for AKNS hierarchy is such an integrable system and showed that the time evolution equations for n≤3 obtained by nonlinearizing the time parts of Lax systems for AKNS hierarchy are Liouville integrable under the constraint of the spatial part. 展开更多
关键词 THE confocal INVOLUTIVE system AND THE INTEGRABILITY OF THE NONLINEARIZED LAX systemS FOR AKNS HIERARCHY 尹公
下载PDF
ERROR ANALYSIS OF 3D DETECTING SYSTEM BASED ON WHOLE-FIELD PARALLEL CONFOCAL MICROSCOPE
9
作者 Wang Yonghong Yu Xiaofen 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2005年第4期623-626,共4页
Compared with the traditional scanning confocal microscopy, the effect of various factors on characteristic in multi-beam parallel confocal system is discussed, the error factors in multi-beam parallel confocal system... Compared with the traditional scanning confocal microscopy, the effect of various factors on characteristic in multi-beam parallel confocal system is discussed, the error factors in multi-beam parallel confocal system are analyzed. The factors influencing the characteristics of the multi-beam parallel confocal system are discussed. The construction and working principle of the non-scanning 3D detecting system is introduced, and some experiment results prove the effect of various factors on the detecting system. 展开更多
关键词 3D profile Parallel detecting confocal Microlens array
下载PDF
Dissolution behavior of Al_(2)O_(3)inclusions into CaO-MgO-SiO_(2)-Al_(2)O_(3)-TiO_(2)system ladle slags
10
作者 Zhiyin Deng Xiaomeng Zhang +2 位作者 Guangyu Hao Chunxin Wei Miaoyong Zhu 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第5期977-987,共11页
To investigate the dissolution behaviors of Al_(2)O_(3)inclusions in CaO-5wt%MgO-SiO_(2)-30wt%Al_(2)O_(3)-TiO_(2)system ladle slags,confocal scanning laser microscopy was conducted on the slags with different TiO_(2)c... To investigate the dissolution behaviors of Al_(2)O_(3)inclusions in CaO-5wt%MgO-SiO_(2)-30wt%Al_(2)O_(3)-TiO_(2)system ladle slags,confocal scanning laser microscopy was conducted on the slags with different TiO_(2)contents(0-10wt%),and scanning electron microscopy was performed to study the interfacial reaction between Al_(2)O_(3)and this slag system.The results disclose that the dissolution of Al_(2)O_(3)inclusions does not result in the formation of new phases at the boundary between the slag and the inclusions.In TiO_(2)-bearing and TiO_(2)-free ladle slags,there is no difference in the dissolution mechanism of Al_(2)O_(3)inclusions at steelmaking temperatures.Boundary layer diffusion is found as the controlling step of the dissolution of Al_(2)O_(3),and the diffusion coefficient is in the range of 4.18×10^(-10)to 2.18×10^(-9)m^(2)/s at 1450-1500℃.Compared with the solubility of Al_(2)O_(3)in the slags,slag viscosity and temperature play a more profound role in the dissolution of Al_(2)O_(3)inclusions.A lower viscosity and a lower melting point of the slags are beneficial for the dissolution.Suitable addition of TiO_(2)(e.g.,5wt%)in ladle slags can enhance the dissolution of Al_(2)O_(3)inclusions because of the low viscosity and melting point of the slags,while excessive addition of TiO_(2)(e.g.,10wt%)shows the opposite trend. 展开更多
关键词 INCLUSIONS DISSOLUTION ladle refining slag titanium dioxide confocal scanning laser microscopy
下载PDF
Investigation on the temperature-dependent diffusion growth of intermetallic compounds in the Mg-Al-Zn system:Experiment and modeling
11
作者 Kaiming Cheng Yan Zheng +12 位作者 Jiaxing Sun Yafei Zhao Jin Wang Huan Yu Dongqing Zhao Hang Li Jixue Zhou Zhenyu Ma Junmin Wang Cuiping Guo Xitao Wang Lijun Zhang Yong Du 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第8期3394-3408,共15页
With the rapid development of Mg alloys,deeper understanding to the thermodynamic and diffusional kinetic behavior of intermetallic compounds(IMCs)is important for studying the effect of alloying elements to the micro... With the rapid development of Mg alloys,deeper understanding to the thermodynamic and diffusional kinetic behavior of intermetallic compounds(IMCs)is important for studying the effect of alloying elements to the microstructure evolution.Specially,a systematic quantitative investigation on the diffusional growth of IMCs is of great necessity.However,the works studying the elemental diffusion behaviors of multiple-element IMCs are rare in magnesium alloy systems.The current work takes the ternary Mg-Al-Zn system as research target,and combines the diffusion couple technique,phase stability diagrams,in-situ observation technique and numerical inverse method to investigate the temperature-dependent kinetic coefficients.The parabolic growth constant(PGC)and interdiffusion coefficients for Mg solid-solution phase andγ-Mg_(17)Al_(12),β-Mg_(2)Al_(3),ε-Mg_(23)Al_(30),MgZn_(2),Mg_(2)Zn_(3),τ-Mg_(32)(Zn,Al)49 andφ-Mg_(5)Zn_(2)Al_(2) IMCs in the Mg-Al-Zn alloy system are determined.By comparing the current experimental with calculation results,the rate-controlling factor of the temperature-dependent diffusion growth ofφ,τandεternary IMCs in the Mg-Al-Zn system is further discussed in detail. 展开更多
关键词 Diffusion couple Phase stability diagram Numerical inverse method(NIM) Interface migration High-temperature laser-scanning confocal microscopy(HTLSCM)
下载PDF
Corneal nerve changes by anti-glaucoma medications examined by in vivo confocal microscopy
12
作者 Xin-Yuan Zhu Qing-Shu Ge +7 位作者 Zong-Yi Li Long-Fang Zhou Qian-Wen Bu Ying Su Xin-Jie Wang Qing-Jun Zhou Xiao-Jing Pan Die Hu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第9期1645-1653,共9页
AIM:To evaluate the effects of antiglaucoma eye drops on corneal nerves by in vivo confocal microscopy(IVCM).METHODS:This study comprised 79 patients diagnosed with glaucoma and 16 healthy control individuals.Among th... AIM:To evaluate the effects of antiglaucoma eye drops on corneal nerves by in vivo confocal microscopy(IVCM).METHODS:This study comprised 79 patients diagnosed with glaucoma and 16 healthy control individuals.Among the glaucoma patients,54 were treated with medication,while 25 remained untreated.Central corneal images were evaluated by IVCM,and then ACCMetrics was used to calculate the following parameters:corneal nerve fiber density(CNFD),branch density(CNBD),fiber length(CNFL),total branch density(CTBD),fiber area(CNFA),fiber width(CNFW),and fractal dimension(CNFrD).The correlation between IVCM parameters and drugs was evaluated using non-parametric measurements of Spearman’s rank correlation coefficient.RESULTS:The CNFD was reduced in glaucoma groups compared to healthy subjects(P<0.01).Patients using anti-glaucoma medications exhibited poorer confocal parameters compared to untreated patients.As the number of medications and usage count increased,CNFD,CNBD,CNFL,CTBD,CNFA,and CNFrD experienced a decline,while CNFW increased(all P<0.01).For the brinzolamide-therapy group,there was a significant decrease in CNFD and CNFL compared to the other monotherapy groups(P<0.001).In the absence of medication,CNFD in males was lower than that in females(P<0.05).Among patients under medication therapy,CNFD remained consistent between males and females.CONCLUSION:Antiglaucoma eye drops affect the microstructure of corneal nerves.IVCM and ACCMetrics are useful tools that could be used to evaluate the corneal nerve changes. 展开更多
关键词 glaucoma therapy corneal nerve fibers in vivo confocal microscopy ACCMetrics
下载PDF
Confocal laser endomicroscopy as a new diagnostic tool for poorly differentiated gastric adenocarcinoma
13
作者 Giuseppe Evola Marco Vacante Francesco R Evola 《World Journal of Clinical Cases》 SCIE 2024年第26期5845-5849,共5页
Gastric cancer(GC)is a multifactorial disease,where both environmental and genetic features can have an impact on its occurrence and development.GC represents one of the leading causes of cancer-related deaths worldwi... Gastric cancer(GC)is a multifactorial disease,where both environmental and genetic features can have an impact on its occurrence and development.GC represents one of the leading causes of cancer-related deaths worldwide.GC is most frequent in males and is believed to arise from a series of premalignant lesions.The detection of GC at an early stage is crucial because early GC,which is an invasive stomach cancer confined to the mucosal or submucosal lining,may be curable with a reported 5-year survival rate of more than 90%.Advanced GC usually has a poor prognosis despite current treatment standards.The diagnostic efficacy of conventional endoscopy(with light endoscopy)is currently limited.Confocal laser endomicroscopy is a novel imaging technique that allows real-time in vivo histological examination of mucosal surfaces during endoscopy.Confocal laser endomicroscopy may be of great importance in the surveillance of precancerous gastric lesions and in the diagnosis of GC.In this editorial we commented on the article about this topic published by Lou et al in the recent issue of the World Journal of Clinical Cases. 展开更多
关键词 confocal laser endomicroscopy In vivo microscopy Optical histology Helicobacter pylori Intestinal metaplasia Gastric atrophy Gastric cancer Early gastric cancer
下载PDF
Confocal laser endomicroscopy for gastric neoplasm
14
作者 Arkadeep Dhali Rick Maity +1 位作者 Roger B Rathna Jyotirmoy Biswas 《World Journal of Gastrointestinal Endoscopy》 2024年第9期540-544,共5页
Confocal laser endomicroscopy(CLE)is a novel endoscopic modality that provides real-time histological information via high-resolution magnified view of the mucosa.CLE has a higher sensitivity,specificity,and diagnosti... Confocal laser endomicroscopy(CLE)is a novel endoscopic modality that provides real-time histological information via high-resolution magnified view of the mucosa.CLE has a higher sensitivity,specificity,and diagnostic accuracy in detecting atrophic gastritis as compared to chromoendoscopy and narrow-band imaging.It can even predict low-grade and high-grade intraepithelial neoplasia by analyzing gastric pit patterns.CLE may have some advantages over the standard biopsy protocol,such as higher diagnostic yield and fewer biopsy requirements.Its diagnostic accuracy in detecting superficial gastric cancer is higher than that of white-light endoscopy.Inherent limitations,such as a narrow field of vision,can be surpassed by technological advancements and integration with other detection methods.Artificial intelligence holds promise in automated analysis of histopathological images.Thus,CLE can be helpful in screening for early gastric cancer and may help reduce the risk of complications from repeated biopsies,such as mucosal damage,bleeding,and infection. 展开更多
关键词 confocal laser endomicroscopy Gastric cancer Narrow band imaging Diagnostic yield
下载PDF
Solidification process of conventional superalloy by confocal scanning laser microscope 被引量:4
15
作者 缪竹骏 单爱党 +3 位作者 王威 卢俊 徐文亮 宋洪伟 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2011年第2期236-242,共7页
The solidification process of a conventional superalloy, IN718, was investigated by confocal scanning laser microscope (CSLM). The liquid fraction during solidification was obtained as a function of real time and te... The solidification process of a conventional superalloy, IN718, was investigated by confocal scanning laser microscope (CSLM). The liquid fraction during solidification was obtained as a function of real time and temperature in reference with the in-situ observation. The characteristics of L→γ transformation were analyzed and the γ growing rate of each stage was also calculated. Scheil equation was employed to predict the segregation behavior, and the predict results are in consistence with the experimental results. As a result, the confocal scanning laser microscope shows a great potential for solidification process research. 展开更多
关键词 IN718 alloy SOLIDIFICATION IN-SITU confocal scanning laser microscope SEGREGATION
下载PDF
Revealing the F_actin Networks in Interphase Nuclei of Garlic Clove Cells by Confocal Fluorescence Microscopy 被引量:2
16
作者 王冬梅 王学臣 张伟成 《Acta Botanica Sinica》 CSCD 2000年第11期1167-1171,共5页
The interphase nuclei of parenchyma cells and epidermal cells of garlic ( Allium sativum L.) clove were labelled with rabbit anti_actin antibody and FITC_conjugated goat anti_rabbit IgG antibody. The authors observ... The interphase nuclei of parenchyma cells and epidermal cells of garlic ( Allium sativum L.) clove were labelled with rabbit anti_actin antibody and FITC_conjugated goat anti_rabbit IgG antibody. The authors observed results with fluorescence microscopy and confocal laser scanning microscopy. The nuclei showed prominent green_yellow fluorescence, indicating the presence of actin in the nuclei. Fluorescence examination with TRITC_phalloidin showed distinctive red fluorescence in the nuclei, indicating that F_actin is present in the nuclei. Confocal laser scanning microscopy indicated the presence of F_actin containing network structures in the nuclei, but the network structures were absent and the nuclei still showed red fluorescence when the cells were treated with cytochalasin D before fixation; the red fluorescence in the nuclei was hard to be observed when the cells were treated with unlabelled phalloidin before the cells were stained with TRITC_phalloidin. These results indicate that F_actin is in the nuclei and forms network structures in the nuclei of garlic cells. 展开更多
关键词 interphase nucleus F_actin TRITC_phalloidin cytochalasin D confocal laser scanning microscopy Allium sativum
下载PDF
Classification of histological severity of Helicobacter pylori-associated gastritis by confocal laser endomicroscopy 被引量:18
17
作者 Peng Wang Rui Ji +5 位作者 Tao Yu Xiu-Li Zuo Chang-Qing Li Zhen Li Yan-Qing Li Cheng-Jun Zhou 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第41期5203-5210,共8页
AIM: To classify the histological severity of Helicobacter pylori (H. pylori) infection-associated gastritis by confocal laser endomicroscopy (CLE). METHODS: Patients with upper gastrointestinal symptoms or individual... AIM: To classify the histological severity of Helicobacter pylori (H. pylori) infection-associated gastritis by confocal laser endomicroscopy (CLE). METHODS: Patients with upper gastrointestinal symptoms or individuals who were screened for gastric cancer were enrolled in this study. Histological severity of H. pylori infection-associated gastritis was graded according to the established CLE criteria. Diagnostic value of CLE for histo-logical gastritis was investigated and compared with that of white light endoscopy (WLE). Targeted biopsies from the sites observed by CLE were performed. RESULTS: A total of 118 consecutive patients with H. pylori infection-associated gastritis were enrolled in this study. Receiver operating characteristic curve analysis showedthat the sensitivity and specifi city of CLE were 82.9% and 90.9% for the diagnosis of H. pylori infection, 94.6% and 97.4% for predicting gastric normal mucosa, 98.5% and 94.6% for predicting histological active inflammation, 92.9% and 95.2% for predicting glan-dular atrophy, 98.6% and 100% for diagnosing intes-tinal metaplasia, respectively. Post-CLE image analysis showed that goblet cells and absorptive cells were the two most common parameters on the CLE-diagnosed intestinal metaplasia (IM) images (P < 0.001). More his-tological lesions of the stomach could be found by CLE than by WLE (P < 0.001). CONCLUSION: CLE can accurately show the histological severity of H. pylori infection-associated gastritis. Mapping IM by CLE has a rather good diagnostic accuracy. 展开更多
关键词 confocal laser endomicroscopy Helicobacter pylori GASTRITIS Classif ication HISTOLOGY
下载PDF
Role of digital chromoendoscopy and confocal laser endomicroscopy for gastric intestinal metaplasia and cancer surveillance 被引量:17
18
作者 Rapat Pittayanon Rungsun Rerknimitr 《World Journal of Gastrointestinal Endoscopy》 CAS 2012年第10期472-478,共7页
In Japan and countries such as South Korea and Tai-wan, China, the standard technique for detecting earlygastric cancer (EGC) is chromoendoscopy. This technique involves a magnified endoscope and the use ofan indigo-c... In Japan and countries such as South Korea and Tai-wan, China, the standard technique for detecting earlygastric cancer (EGC) is chromoendoscopy. This technique involves a magnified endoscope and the use ofan indigo-carmine spray to distinguish between EGCand non-EGC areas. However, this technique is notwidely adopted in many parts of the world. One important reason for limited use is that this technique needsan experienced endoscopist to interpret the imagesduring the procedure. In addition, the sensitivity for detecting gastric intestinal metaplasia (GIM), a precancerous lesion of EGC, is graded as suboptimal. Moreover,the requirement of a cumbersome spraying method isinconvenient and needs preparation time. Easier digitalchromoendoscopy techniques, such as Narrow-bandImaging and Flexible spectral Imaging Color Enhancement, have been reported to facilitate targeted GIM and EGC biopsy. They provide higher sensitivities over conventional white light endoscopy. Recently, the noveltechnology of confocal laser endomicroscopy has been introduced as a high-magnification (1000 ×) real-time evaluation for many early gastrointestinal (GI) cancersand precancerous GI lesions, including colonic polyp,Barrett's esophagus, and GIM. The advantage of this technique is that it can be used as an in vivo confirmation of the presence of GIM and EGC during endoscopic surveillance. This review aims to explain the current information on the usefulness of digital chromoendos-copy and confocal laser endomicroscopy for evaluating GIM and EGC during endoscopic surveillance and the possible future role of these techniques for GI cancerscreening programs. 展开更多
关键词 confocal laser endomicroscope CHROMOENDOSCOPY GASTRIC INTESTINAL METAPLASIA
下载PDF
Confocal laser endomicroscopy in the “in vivo” histological diagnosis of the gastrointestinal tract 被引量:11
19
作者 Giovanni D De Palma 《World Journal of Gastroenterology》 SCIE CAS CSCD 2009年第46期5770-5775,共6页
Recent technological advances in miniaturization have allowed for a confocal scanning microscope to be integrated into a conventional flexible endoscope,or into trans-endoscopic probes,a technique now known as confoca... Recent technological advances in miniaturization have allowed for a confocal scanning microscope to be integrated into a conventional flexible endoscope,or into trans-endoscopic probes,a technique now known as confocal endomicroscopy or confocal laser endomicroscopy.This newly-developed technology has enabled endoscopists to collect real-time in vivo histological images or "virtual biopsies" of the gastrointestinal mucosa during endoscopy,and has stimulated significant interest in the application of this technique in clinical gastroenterology.This review aims to evaluate the current data on the technical aspects and the utility of this new technology in clinical gastroenterology and its potential impact in the future,particularly in the screening or surveillance of gastrointestinal neoplasia. 展开更多
关键词 confocal microscopy Diagnostic imaging Gastrointestinal neoplasms Precancerous conditions ENDOSCOPY Virtual histology
下载PDF
Diagnosis of gastric intraepithelial neoplasia by narrow-band imaging and confocal laser endomicroscopy 被引量:11
20
作者 Shu-Fang Wang Yun-Sheng Yang +7 位作者 Li-Xin Wei Zhong-Sheng Lu Ming-Zhou Guo Jin Huang Li-Hua Peng Gang Sun En-Qiang Ling-Hu Jiang-Yun Meng 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第34期4771-4780,共10页
AIM:To evaluate the diagnosis of different differentiated gastric intraepithelial neoplasia (IN) by magnifica-tion endoscopy combined with narrow-band imaging (ME-NBI) and confocal laser endomicroscopy (CLE). METHODS:... AIM:To evaluate the diagnosis of different differentiated gastric intraepithelial neoplasia (IN) by magnifica-tion endoscopy combined with narrow-band imaging (ME-NBI) and confocal laser endomicroscopy (CLE). METHODS:Eligible patients with suspected gastric IN lesions previously diagnosed by endoscopy in secondary hospitals and scheduled for further diagnosis and tratment were recruited for this study. Excluded from the study were patients who had liver cirrhosis, impaired renal function, acute gastrointestinal (GI) bleeding, coagulopathy, esophageal varices, jaundice, and GI post-surgery. Also excluded were those who were pregnant, breastfeeding, were younger than 18 years old, or were unable to provide informed consent. All patients had all mucus and bile cleared from their stom-achs. They then received upper GI endoscopy. When a mucosal lesion is found during observation with whitelight imaging, the lesion is visualized using maximal magnification, employing gradual movement of the tip of the endoscope to bring the image into focus. Saved images are analyzed. Confocal images were evaluated by two endoscopists (Huang J and Li MY), who were familiar with CLE, blinded to the related information about the lesions, and asked to classify each lesion as either a low grade dysplasia (LGD) or high grade dysplasia (HGD) according to given criteria. The results were compared with the final histopathologic diagnosis. ME-NBI images were evaluated by two endoscopists (Lu ZS and Ling-Hu EQ) who were familiar with NBI, blinded to the related information about the lesions and CLE images, and were asked to classify each lesion as a LGD or HGD according to the "microvascular pattern and surface pattern" classification system. The results were compared with the final histopathologic diagnosis. RESULTS: The study included 32 pathology-proven low grade gastric IN and 26 pathology-proven high grade gastric IN that were detected with any of the modalities. CLE and ME-NBI enabled clear visualization of the vascular microsurface patterns and microvascular structures of the gastric mucosa. The accuracy of the CLE and the ME-NBI diagnosis was 88% (95% CI:78%-98%) and 81% (95% CI: 69%-93%), respectively. The kappa coefficient of agreement between the histopathology and the in vivo CLE imaging was 0.755; between the histopathology and the in vivo CLE imaging was 0.615. McNemar's test (binomial distribution used) indicated that the agreement was significant (P < 0.05). When patients were diagnosed by MENBI with CLE, the overall accuracy of the diagnosis was 86.21% (95% CI:73%-96%), and the kappa coefficient of agreement was 0.713, according to McNemar's test (P < 0.05). CONCLUSION:Higher diagnostic accuracy, sensitivityand specificity of CLE over ME-NBI indicate the feasibility of these two techniques for the efficacious diagnostic classification of gastric IN. 展开更多
关键词 Gastric intraepithelial neoplasia Histologicaldiagnosis confocal laser endomicroscopy Magnifica-tion endoscopy Narrow-band imaging Gastric intraepi-thelial neoplasia lesion
下载PDF
上一页 1 2 16 下一页 到第
使用帮助 返回顶部