In order to check the traditional core loss formula, the core loss spectrum P(f) of Co-based amorphous soft magnetic alloy with constant permeability has been studied. It is found that within a high frequency range fr...In order to check the traditional core loss formula, the core loss spectrum P(f) of Co-based amorphous soft magnetic alloy with constant permeability has been studied. It is found that within a high frequency range from 10 kHz to 200 kHz and at Bm = 0. 1 T,the P(f) has the fractal structure P (f) = Po, and with the increasing of induced anisotropy energy Ku, the fractal dimension Dfrises, thus the total power loss at high frequency increases and the frequency characteristic of P(f) becomes worse.展开更多
Ca1-xRbxCu3Ti4O12 (x=0, 0.01, 0.02 and 0.03) ceramics were synthesized by the sol-gel method. Doping Rb+ reduces dielectric loss, which reaches minimum when x=0.02. By measuring properties of electrical conduction,...Ca1-xRbxCu3Ti4O12 (x=0, 0.01, 0.02 and 0.03) ceramics were synthesized by the sol-gel method. Doping Rb+ reduces dielectric loss, which reaches minimum when x=0.02. By measuring properties of electrical conduction, larger leakage current density and height of grain-boundary Sehottky potential barrier (φB) were found in the doped samples, and φB became maximum when x=0.02. These results are attributed to the increase in the amount of oxygen vacancies and the formation of Cu-rich/Ti-poor grain-boundary layers, and it can be concluded that the dielectric loss in CCTO ceramic can be reduced by manipulating the composition and electrical properties of grain boundary.展开更多
Superconducting TF and PF coils have been measured in SULTAN test facility. Segregated copper strands are included in four NbTi CICC and this is a technical innovation. Two AC losses measurement methods, calorimetric ...Superconducting TF and PF coils have been measured in SULTAN test facility. Segregated copper strands are included in four NbTi CICC and this is a technical innovation. Two AC losses measurement methods, calorimetric and electromagnetic methods, have been used in the experiments, and a broad frequency range (from 0.05 Hz to 6 Hz) is covered in sample test. The purpose of this experiment was to investigate AC losses of TF and PF CICC conductor including segregated copper and to check the design of PF and TF CICC coated with different resistive barriers (Pb-30Sn-2Sb and Ni plating on NbTi strands).展开更多
Irradiation effects of γ-radiation on the physical and electrical properties of polycarbonate (Makrofol-E( film has been studied to be able to investigate the dielectric response of irradiated polymers for a wide ran...Irradiation effects of γ-radiation on the physical and electrical properties of polycarbonate (Makrofol-E( film has been studied to be able to investigate the dielectric response of irradiated polymers for a wide range of fluence and frequency. The dielectric constant (ε') The loss tangent (tanδ), dielectric loss factor (ε''), the a.c electrical conductivity (σ) and the relaxation time (τ), were measured in the frequency range from (40) Hz to (4) MHz. These samples were irradiated by means of γ-rays from 10 up to 200 KGy. The change in different properties as a function of absorbed dose was studied. Degradation of the polymers leading to amorphisation was observed by increasing the absorbed γ- dose. The induced changes in the electrical conductivity due to γ-rays irradiation of Makrofol-E provide a better method for γ -dose measurements. A semi-empirical equation was developed to use Makrofol-E as a dielectric dosimeter. Furthermore, Makrofol-E has much greater resistance to radiation damage;the attained results suggested strongly the applicability of Makrofol-E to be used in medical products applications.展开更多
文摘In order to check the traditional core loss formula, the core loss spectrum P(f) of Co-based amorphous soft magnetic alloy with constant permeability has been studied. It is found that within a high frequency range from 10 kHz to 200 kHz and at Bm = 0. 1 T,the P(f) has the fractal structure P (f) = Po, and with the increasing of induced anisotropy energy Ku, the fractal dimension Dfrises, thus the total power loss at high frequency increases and the frequency characteristic of P(f) becomes worse.
基金Funded by The National Natural Science Foundation of China(Nos.51172166,51202078,and 61106005)
文摘Ca1-xRbxCu3Ti4O12 (x=0, 0.01, 0.02 and 0.03) ceramics were synthesized by the sol-gel method. Doping Rb+ reduces dielectric loss, which reaches minimum when x=0.02. By measuring properties of electrical conduction, larger leakage current density and height of grain-boundary Sehottky potential barrier (φB) were found in the doped samples, and φB became maximum when x=0.02. These results are attributed to the increase in the amount of oxygen vacancies and the formation of Cu-rich/Ti-poor grain-boundary layers, and it can be concluded that the dielectric loss in CCTO ceramic can be reduced by manipulating the composition and electrical properties of grain boundary.
文摘Superconducting TF and PF coils have been measured in SULTAN test facility. Segregated copper strands are included in four NbTi CICC and this is a technical innovation. Two AC losses measurement methods, calorimetric and electromagnetic methods, have been used in the experiments, and a broad frequency range (from 0.05 Hz to 6 Hz) is covered in sample test. The purpose of this experiment was to investigate AC losses of TF and PF CICC conductor including segregated copper and to check the design of PF and TF CICC coated with different resistive barriers (Pb-30Sn-2Sb and Ni plating on NbTi strands).
文摘Irradiation effects of γ-radiation on the physical and electrical properties of polycarbonate (Makrofol-E( film has been studied to be able to investigate the dielectric response of irradiated polymers for a wide range of fluence and frequency. The dielectric constant (ε') The loss tangent (tanδ), dielectric loss factor (ε''), the a.c electrical conductivity (σ) and the relaxation time (τ), were measured in the frequency range from (40) Hz to (4) MHz. These samples were irradiated by means of γ-rays from 10 up to 200 KGy. The change in different properties as a function of absorbed dose was studied. Degradation of the polymers leading to amorphisation was observed by increasing the absorbed γ- dose. The induced changes in the electrical conductivity due to γ-rays irradiation of Makrofol-E provide a better method for γ -dose measurements. A semi-empirical equation was developed to use Makrofol-E as a dielectric dosimeter. Furthermore, Makrofol-E has much greater resistance to radiation damage;the attained results suggested strongly the applicability of Makrofol-E to be used in medical products applications.