期刊文献+
共找到336篇文章
< 1 2 17 >
每页显示 20 50 100
Effectiveness of toric soft contact lenses for vision correction in patients with different degrees of astigmatism: a real-world study
1
作者 Guo-Yun Zhang Lu Ye +3 位作者 Wen-Jun Wang Yi-Ming Guo Jun-Han Wei Mei-Xia Ren 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第11期1845-1853,共9页
AIM:To assess the visual correction of patients with different degrees of astigmatism with toric soft contact lenses(TSC).METHODS:It was a real-world study with prospective and single-arm design.A total of 384 patient... AIM:To assess the visual correction of patients with different degrees of astigmatism with toric soft contact lenses(TSC).METHODS:It was a real-world study with prospective and single-arm design.A total of 384 patients with astigmatism who came for TSC fitting and alignment from November 2022 to January 2023 were included.According to the difference in astigmatism,patients were divided into groups A(cylinder degree:-0.75 to-0.50 D),B(cylinder degree:-1.75 to-1.00 D)and C(cylinder degree≤-2.00 D),and followed up on the day of wear,1wk,1 and 3mo,mainly to observe visual acuity,refraction,lens fit,visual quality and comfort at 1wk after wear.The visual acuity success rate and the overall success rate of the fitting were evaluation indicators(taking into account the four dimensions of visual acuity,fitting,quality of vision and comfort).The visual acuity success rate was calculated by taking“corrected visual acuity with contact lenses is no less than 1 line or better than best spectacle-corrected visual acuity”(i.e.corrected visual acuity with contact lenses is 1 line below,equal to,one line above or more than best spectaclecorrected visual acuity)as the criterion for visual success,and the the overall success rate of the fitting was calculated by using the comprehensive indicators(visual acuity,fit,visual quality,comfort)to meet certain conditions as the judgment criteria for successful fitting.RESULTS:After 1wk of wearing TSC,the visual acuity success rates of patients were 100%(207/207),98.58%(139/141)and 97.22%(35/36)in the three groups,respectively,with residual cylinder closed to 0.The acceptability of the lens fitting was over 95%;the incidence of adverse visual symptoms was within 10%and the comfort acceptability was over 97%.The overall success rate of fitting for patients with high,medium and low astigmatism was 93.72%(194/207),90.78%(128/141)and 88.89%(32/36),respectively.CONCLUSION:TSC(model:G&G POP·CT)are effective in correcting astigmatism in patients with different degrees of astigmatism. 展开更多
关键词 toric soft contact lenses ASTIGMATISM visual acuity
下载PDF
Clinic study on silicone hydrogel contact lenses used as bandage contact lenses after LASEK surgery 被引量:7
2
作者 Xiao-Mei Qu Jin-Hui Dai +1 位作者 Zhen-Ying Jiang and Yi-Feng Qian 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2011年第3期314-318,共5页
AIM: To compare the clinical performance of two types of silicon hydrogel contact lenses used as bandage lenses after LASEK surgery. METHODS: A prospective, double-masked study was conducted on 42 eyes of 21 patients ... AIM: To compare the clinical performance of two types of silicon hydrogel contact lenses used as bandage lenses after LASEK surgery. METHODS: A prospective, double-masked study was conducted on 42 eyes of 21 patients who received binocular LASEK surgeries. The interocular difference in spherical equivalent power was less than -1.50D. Patients were randomly assigned to wear Galyfilcon A (Lens A) bandage contact lens in one eye and Balafilcon A (Lens B) in the fellow eye after the surgery. The responses to a subjective questionnaire on comfort of wearing, corneal epithelial status, conjunctival hyperemia, limbal neovascularization, lens fitting and contact lens debris were assessed 1 and 5 days postoperatively. Corneal endothelium was assessed before and 5 days after the surgery upon bandage lens removal. RESULTS: There was no difference between the two groups in terms of conjunctival hyperemia, limbal neovascularization, contact lens fitting, corneal epithelial status, corneal endothelium cell density (CD) and endothelium cell size (CS) at any postoperative visit. Complaints of discomfort, including foreign body sensation, pain and intolerance were statistically more among Lens B wearers at any postoperative visit (P < 0.05). Lens B appeared to attract much more debris than Lens A at the 5-day post-operative follow-up visit (P < 0.01). CONCLUSION: The two types of silicon hydrogel lenses investigated in this study demonstrated similar clinical performance in terms of corneal responses and lens fitting. However, Lens A showed a better performance in terms of comfort of wearing and deposit resistance. 展开更多
关键词 therapeutic contact lens bandage contact lens silicone hydrogel contact lens LASEK
下载PDF
Contact lens as an emerging platform for ophthalmic drug delivery:A systematic review
3
作者 Hongyu Yang Ming Zhao +8 位作者 Dandan Xing Jian Zhang Ting Fang Faxing Zhang Zhihao Nie Yaming Liu Lihua Yang Ji Li Dongkai Wang 《Asian Journal of Pharmaceutical Sciences》 SCIE CAS 2023年第5期26-50,共25页
The number of people with eye diseases has increased with the use of electronics.However,the bioavailability of eye drops remains low owing to the presence of the ocular barrier and other reasons.Although many drug de... The number of people with eye diseases has increased with the use of electronics.However,the bioavailability of eye drops remains low owing to the presence of the ocular barrier and other reasons.Although many drug delivery systems have been developed to overcome these problems,they have certain limitations.In recent years,the development of contact lenses that can deliver drugs for long periods with high bioavailability and without affecting vision has increased the interest in using contact lenses for drug delivery.Hence,a review of the current state of research on drug delivery contact lenses has become crucial.This article reviews the key physical and chemical properties of drug-laden contact lenses,development and classification of contact lenses,and features of the commonly used materials.A review of the methods commonly used in current research to create contact lenses has also been presented.An overview on how drug-laden contact lenses can overcome the problems of high burst and short release duration has been discussed.Overall,the review focuses on drug delivery methods using smart contact lenses,and predicts the future direction of research on contact lenses. 展开更多
关键词 Drug-loaded contact lenses Drug-loaded smart contact lenses Corneal diseases Ocular drug delivery Key attributes of contact lenses
下载PDF
Aberration changes of the corneal anterior surface following discontinued use of rigid gas permeable contact lenses 被引量:5
4
作者 Qing Yu Jiang-Xiu Wu +3 位作者 He-Ning Zhang Sheng Ye Shi-Qi Dong Chen-Hao Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第2期178-182,共5页
AIM: To record aberrations with a corneal topographic device on the anterior surface of the cornea at different time-points prior to wearing and following discontinued use of rigid gas permeable (RGP) contact lenses. ... AIM: To record aberrations with a corneal topographic device on the anterior surface of the cornea at different time-points prior to wearing and following discontinued use of rigid gas permeable (RGP) contact lenses. The effect of wearing RGP on the anterior surface of the cornea was discussed to provide guidance for clinical refractive error correction.METHODS: The study objects were 24 eyes from 24 patients. All patients underwent identical examination procedures prior to lens use, as well as afterwards, including slit-lamp examination, non-contact tonometer measurement, computer optometry and corneal curvature measurement, subjective refraction test, and corneal topography analysis. The patients wore contact lenses everyday for 1 month and then discontinued. Corneal topographies were recorded at certain time points of 30 minutes, 1 day, 3, 7 and 14 days following use.RESULTS: Total corneal aberration at each time point following discontinued use of RGP contact lenses was less than the time point prior to use. Detailed results were as follows: root mean square (RMS) (pre)=(1.438± 0.328)μm, RMS (30 minutes) =(1.076 ±0.355)μm, RMS (1 day) =(1.362 ±0.402)μm, RMS (3 days) =(1.373 ±0.398)μm, RMS (7 days) =(1.387 ±0.415)μm, and RMS (14 days) = (1.430±0.423)μm. Results showed that at 30 minutes after discontinued use of RGP contact lenses, almost all 2 ndand 3 rd-order aberrations change. Quadrafoil Z10 and spherical Z12 of the 4 th-order were also changed. Alterations to Z5, Z6, and Z12 at 1 day after discontinued use were significant differences compared with the time period prior to RGP use: Z5 and Z6 decreased, and Z12 increased slightly. Z5 and Z6 remained decreased at 3 days after discontinued use, but Z9 and Z10 continued to increase and Z12 returned to levels prior to RGP use. At 14 days after discontinued use, all aberrations were notsignificantly different from the values prior to use.CONCLUSION: The use RGP contact lenses greatly reduced total aberration of the anterior surface of the cornea. Changes to 2 ndand 3 rd-order aberrations (including Z3, Z4, Z5, Z6, Z7, and Z8) were more significant. Following discontinued use of RGP contact lenses, the majority of lower order aberrations returned to original levels in a short period of time. During this process, a transient higher order aberration appeared, but all changes disappeared within 14 days after discontinued use of RGP contact lenses. 展开更多
关键词 ABERRATION rigid gas permeable contact lens CORNEA
下载PDF
Objective assessment of the effect of pupil size upon the power distribution of multifocal contact lenses 被引量:2
5
作者 Eleni Papadatou Antonio J.Del Aguila-Carrasco +2 位作者 Jose J.Esteve-Taboada David Madrid-Costa Alejandro Cervino-Exposito 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第1期103-108,共6页
AIM: To analytically assess the effect of pupil size upon the refractive power distributions of different designs of multifocal contact lenses.METHODS: Two multifocal contact lenses of center-near design and one mul... AIM: To analytically assess the effect of pupil size upon the refractive power distributions of different designs of multifocal contact lenses.METHODS: Two multifocal contact lenses of center-near design and one multifocal contact lens of center-distance design were used in this study. Their power profiles were measured using the NIMO TR1504 device (LAMBDA-X, Belgium). Based on their power profiles, the power distribution was assessed as a function of pupil size. For the high addition lenses, the resulting refractive power as a function of viewing distance (far, intermediate, and near) and pupil size was also analyzed.RESULTS: The power distribution of the lenses was affected by pupil size differently. One of the lenses showed a significant spread in refractive power distribution, from about ?3 D to 0 D. Generally, the power distribution of the lenses expanded as the pupil diameter became greater. The surface of the lens dedicated for each distance varied substantially with the design of the lens.CONCLUSION: In an experimental basis, our results show how the lenses power distribution is affected by the pupil size and underlined the necessity of careful evaluation of the patient’s visual needs and the optical properties of a multifocal contact lens for achieving the optimal visual outcome. 展开更多
关键词 multifocal contact lenses pupil size power profiles refractive power distribution
下载PDF
Contact lens impact on quality of life in keratoconus patients: rigid gas permeable versus soft siliconehydrogel keratoconus lenses 被引量:4
6
作者 Elvin Hatice Yildiz Mesut Erdurmus +2 位作者 Emine Savran Elibol Banu Acar Ece Turan Vural 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第5期1074-1077,共4页
AIMTo determine the impact of rigid gas permeable (RGP) and silicone-hydrogel keratoconus lenses on the quality of life (QoL) in keratoconus (KCN) patients using the self-reported results from the Contact Lens Impact ... AIMTo determine the impact of rigid gas permeable (RGP) and silicone-hydrogel keratoconus lenses on the quality of life (QoL) in keratoconus (KCN) patients using the self-reported results from the Contact Lens Impact on Quality of Life (CLIQ) Questionnaire.METHODSFrom January 2013 to April 2013, 27 consecutive KCN patients who wore RGP contact lenses (conflexair100 UV KE Zeiss-W&#x000f6;hlk) or soft silicone-hydrogel contact lenses (SHCLs) for KCN (KeraSoft IC- Bausch&#x00026;Lomb or Hydrocone Toris K-Swiss lens) completed the CLIQ questionnaire.RESULTSThe mean age of 27 patients was 29.6&#x000b1;8.0y. Fifteen patients were RGP user. The groups were comparable with respect to the mean patient age, sex, and mean K values (P=0.1, P=0.8 and P=0.1, respectively). The mean CLIQperson measure was 42.8&#x000b1;5.5 in RGP group and 39.6&#x000b1;5.5 in SHCLs for KCN group (P=0.06). CLIQperson measure was positively correlated with steep K value (r=0.301, P=0.04). When eyes were stratified by visual acuity with contact lenses, the mean CLIQperson measure was 42.01&#x000b1;5.6 in eyes with a visual acuity of 20/20-20/25 (n=44) and 38.4&#x000b1;5.26 in eyes with a visual acuity of 20/32 or less (n=10; P=0.097).CONCLUSIONRGP lenses and SHCLs for KCN have similar impact on QoL. 展开更多
关键词 silicone hydrogel contact lens rigid gas permeable quality of life KERATOCONUS
下载PDF
Endothelial parameters in central and peripheral cornea in patients wearing contact lenses 被引量:2
7
作者 Saulius Galgauskas Justina Ignataviciute +1 位作者 Zivile Vieversyte Rimvydas Asoklis 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第11期1768-1773,共6页
AIM: To measure the parameters of endothelium in the central and peripheral parts of the cornea and evaluate the influence of wearing the hard and soft contact lenses on the mentioned parameters.METHODS: A specular ... AIM: To measure the parameters of endothelium in the central and peripheral parts of the cornea and evaluate the influence of wearing the hard and soft contact lenses on the mentioned parameters.METHODS: A specular microscope was used to measure the corneal endothelium parameters in both eyes of 139 Caucasians(a total of 278). All participants were divided into three groups: soft lens wearers, hard lens wearers and a control group. Factors, such as age, smoking, types of lens material, duration of lens wear and lens air permeability were assessed to determine their impact on the morphometric parameters of the endothelium.RESULTS: A lower percentage of hexagon-like cells and higher cell variation than in other groups were determined in hard contact lens wearers. The difference in density of endotheliocytes between the groups was not observed. The measurements of the morphometric parameters in soft contact lens wearers did not depend neither on the duration of lens wear, nor on air permeability. The relation between the patients' age and the variation of endothelium parameters was determined in the group of hard contact lens wearers.CONCLUSION: Wearing hard contact lenses provokes pleomorphism and polymegethism of the corneal endothelium, while soft contact lenses do not impact any parameters of the endothelium, most likely due to higher air permeability. 展开更多
关键词 corneal endothelium morphometry endothelial changes contact lenses
下载PDF
Enhanced drug loading efficiency of contact lenses via salt-induced modulation 被引量:1
8
作者 Qiang Zhu Shirui Mao 《Asian Journal of Pharmaceutical Sciences》 SCIE CAS 2019年第2期204-215,共12页
Low drug loading efficiency is one of the main obstacles hindering the application of contact lenses(CLs) as the carrier for extended ocular drug delivery. Here in this study, a simple and effective drug loading metho... Low drug loading efficiency is one of the main obstacles hindering the application of contact lenses(CLs) as the carrier for extended ocular drug delivery. Here in this study, a simple and effective drug loading method based on salt induced modulation was proposed and demonstrated with mechanism elucidation. First of all, using poly(2-hydroxyethyl methacrylate)(p-HEMA) as the contact lens material, betaxolol hydrochloride, Diclofenac Sodium and Betaxolol Base as the model drugs with different solubility, influence of salt concentration,salt type(sodium salts of sulfate, chloride, and sulfocyanate) and drug properties in the loading solution on drug loading efficiency was investigated. Mechanism of enhanced drug loading in contact lens was further explored via studying the influence of salt on the absorption isotherm, drug solubility and water content of CLs. Applicability of this method to other CLs materials was also investigated. It was demonstrated that adjusting the ionic strength of loading solutions resulted in significant increase of drug loading in CLs. Type and concentration of the salts and solubility of the drug were the main factors influencing enhancement ratio of drug loading. The mechanism for improved drug loading was related to the reduced drug solubility in loading solutions and the reduced bound water content in contact lenses. Modulation of drug loading by adjusting ionic strength was also applicable to other CLs and the light transmittance was not affected. This method was more suitable for salt-form drugs with high solubility. In summary, adjusting ionic strength of loading solution is an economical and effective way to improve drug loading in CLs, and this simple method may also find application in other hydrogel based drug delivery systems. 展开更多
关键词 contact lenses DRUG loading IONIC strength ABSORPTION isotherms DRUG SOLUBILITY BOUND water content
下载PDF
Evaluation of the safety and efficacy of therapeutic bandage contact lenses on post-cataract surgery patients 被引量:6
9
作者 Dan-Na Shi Hang Song +2 位作者 Tong Ding Wei-Qiang Qiu Wei Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第2期230-234,共5页
AIM: To evaluate the safety of therapeutic bandage contact lens for post-cataract surgery patients and to illustrate its efficacy on post-operative comfort and tear-film stability. METHODS: A total of 40 participant... AIM: To evaluate the safety of therapeutic bandage contact lens for post-cataract surgery patients and to illustrate its efficacy on post-operative comfort and tear-film stability. METHODS: A total of 40 participants were recruited and randomly divided into two groups. Group one was instructed to wear bandage contact lenses for a week and use antibiotic eye drops for a month since the first day after surgery. Group two received sub-conjunctival injection of tobramycin and was asked to wear eye pads on the first day after surgery and then were instructed to use antibiotic eye drops as the first group did. Ocular surface disease index(OSDI) questionnaire, slit-lamp microscope examination of tear break-up time(TBUT), corneal fluorescein score(CFS), tear meniscus height(TMH) together with anterior segment optical coherence tomography(AS-OCT) and corneal topography were evaluated preoperatively and postoperatively. RESULTS: The subjective feeling(P=0.004), TBUT(P〈0.001) and TMH(P=0.02) post-surgery had improved in patients who used bandage contact lenses compared with those who did not at 1wk post-surgery. Until three month postoperatively, the comfort degree(P=0.004) and TMH(P=0.01) of group two were still worse than group one. Moreover, TBUT(P〈0.001) and CFS(P=0.004) of the group with eye pads got worse than the results before, whereas the group with bandage contact lenses recovered to normal. None of these patients had infections or other complications. CONCLUSION: Wearing therapeutic bandage contact lens after cataract surgery, compared with traditional eye-pads, is a safe method to improve tear-film stability and reduce post-operative discomfort without hindering corneal incision recovery. 展开更多
关键词 bandage contact lens cataract surgery tearfilm stability comfort
下载PDF
Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses 被引量:1
10
作者 Kazunori Hirasawa Hikaru Ito +2 位作者 Yukari Ohori Yui Takano Nobuyuki Shoji 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第10期1559-1565,共7页
AIM:To evaluate the refractive correction for standard automated perimetry(SAP)in eyes with refractive multifocal contact lenses(CL)in healthy young participants.METHODS:Twenty-nine eyes of 29 participants were ... AIM:To evaluate the refractive correction for standard automated perimetry(SAP)in eyes with refractive multifocal contact lenses(CL)in healthy young participants.METHODS:Twenty-nine eyes of 29 participants were included.Accommodation was paralyzed in all participants with 1%cyclopentolate hydrochloride.SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions:monofocal CL corrected for near distance(baseline);multifocal CL corrected for distance(m CL-D);and m CL-D corrected for near vision using a spectacle lens(m CL-N).Primary outcome measures were the foveal threshold,mean deviation(MD),and pattern standard deviation(PSD).RESULTS:The foveal threshold of m CL-N with both the24-2 and 10-2 protocols significantly decreased by 2.2-2.5 d B(P〈0.001),while that of m CL-D with the 24-2 protocol significantly decreased by 1.5 d B(P=0.0427),as compared with that of baseline.Although there was no significant difference between the MD of baseline and m CL-D with the24-2 and 10-2 protocols,the MD of m CL-N was significantly decreased by 1.0-1.3 d B(P〈0.001)as compared with that of both baseline and m CL-D,with both 24-2 and 10-2 protocols.There was no significant difference in the PSD among the three refractive conditions with both the 24-2 and 10-2 protocols.CONCLUSION:Despite the induced mydriasis and the optical design of the multifocal lens used in this study,our results indicated that,when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs,distance correction without additional near correction is to be recommended. 展开更多
关键词 intraocular lens multifocal contact lens refractive correction standard automated perimetry visual field
下载PDF
Impact of multifocal gas-permeable lens designs on short-term choroidal response, axial length, and retinal defocus profile
11
作者 Muteb Alanazi Patrick Caroline +1 位作者 Amane Alshamrani Maria Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期247-256,共10页
AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defoc... AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defocus profile in young adults.METHODS:Seventeen young adults(2 males and 15 females;age 23.17±4.48y)were randomly assigned to wear two designs binocularly with a one-week washout period in between.Total of four MFGPCL designs were assessed.All designs were distance-center that varied in two add power(+1.50 and 3.00 D)and/or two distance zone(DZ)diameters(1.50 and 3.00 mm;design A:DZ 1.5/add 3.0,B:DZ 1.5/add 1.5,C:DZ 3.0/add 3.0,D:DZ 3.0/add 1.5).ChT,AL,and peripheral refraction data were collected on each subject at baseline,on days 1 and 7 of MFGPCL daily wear.ChT was assessed in four quadrants using a spectraldomain optical coherence tomography.RESULTS:AL was shortened by-26±44μm with lens C,-18±27μm with lens D,-13±29μm with lens A,and-8±30μm with lens B(all P<0.05).A significant overall increase in ChT was observed with all 4 designs(lens A:+6±6μm,B:+3±7μm,C:+8±7μm,and D:+8±7μm).Temporal and superior choroid exhibited more choroidal thickening associated with MFGPCL.All designs induced significant relative peripheral myopia(RPM)beyond the central 20o across the horizontal meridian in both nasal and temporal fields(P<0.05).CONCLUSION:MFGPCLs show a significant influence on ChT and AL,which are associated with significant increase in RPM after short-term wear.The reliability and feasibility of quantifying short-term changes in ChT support its use as a promising marker for the long-term efficacy of myopia-controlling treatments. 展开更多
关键词 CHOROID gas-permeable contact lens retinal defocus axial length MYOPIA
下载PDF
Application of Flipped Classroom Teaching Model Based on Micro-Course in Practical Training Teaching of Contact Lens Fitting Technology
12
作者 Ying Zou 《Journal of Contemporary Educational Research》 2023年第9期98-104,共7页
Objective:This paper aims to study the application of flipped classroom teaching model based on micro-course in the practical training teaching of contact lens fitting technology.Methods:From September 21 to July 23,1... Objective:This paper aims to study the application of flipped classroom teaching model based on micro-course in the practical training teaching of contact lens fitting technology.Methods:From September 21 to July 23,120 students majoring in ophthalmology and optometry were selected and randomly divided into groups.The control group adopted the traditional teaching mode,and the study group adopted the flipped classroom teaching mode based on micro-course.Teaching scores and the skills,observation and judgment,adaptability,and communication skills were compared between the groups.Results:Statistical comparison of teaching scores under different management methods showed that the clinical thinking score and practice work quality in the study group were higher than those of the control group,and the effect of the study group was better(P<0.05).The overall scores of skills,observation and judgment,adaptability,and communication skills of the study group were better than those in the control group,and the comprehensive ability scores in the two groups were significantly different(P<0.05).Conclusion:In practical training teaching of contact lens fitting technology,the application of flipped classroom teaching based on micro-course can improve the skill scores of personnel,and the overall effect is good.This can lay the foundation for advanced ophthalmology and optometry talents with profound theoretical knowledge and professional skills. 展开更多
关键词 contact lens fitting technology practical training and teaching Micro-course based Flipped classroom teaching APPLICATION
下载PDF
Application of Sodium Ion Sensor Based on the SnO_2/ITO Glass in the Detection of Rinsing Solution for Contact Lenses
13
作者 Jui-Fu Cheng Jung-Chuan Chou +1 位作者 Tai-Ping Sun Shen-Kan Hsiung 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期240-241,共2页
This paper presents the studying results of the sodium ion sensor device based on the SnO_2/ITO glass structure in the detection of rinsing solution for contact lenses.The selective membrane contains poly (vinyl chlor... This paper presents the studying results of the sodium ion sensor device based on the SnO_2/ITO glass structure in the detection of rinsing solution for contact lenses.The selective membrane contains poly (vinyl chloride) (PVC),bis (2-ethylhexyl) sebacate (DOS),(12-crown-4) methylmalonate (B12C4),and sodium tetrakis (4-fluoropbenyl) borate dehydrate (NaTFBD). The final weight ratios are PVC:DOS:B12C4:NaTFBD=33:66:2:2.In this condition,the sensor has performances with linear sensitivity,short response time,good repeatability and selectivity.The sensor was used to measure the rinsing solution for the contact lenses.Because the experimental results show close to the accurate value for four commercial products,this sensor can preliminary be used in detecting the rinsing solution for the contact lenses.Using this structure and sodium-sensing membrane to construct the sodium sensor is proven successfully in this application. 展开更多
关键词 sodium ion sensor solution for contact lenses tin oxide electrode B12C4
下载PDF
Is the Use of Empirically Designed Custom Soft Contact Lenses a Good Option for Challenging Patients?
14
作者 Frank Spors Donald J. Egan +2 位作者 Lance E. McNaughton Jie Shen Matthew J. Lampa 《Open Journal of Ophthalmology》 2013年第3期54-60,共7页
Purpose: Reasons for the lack of success for contact lens patients range from poor fit, to discomfort or to a less than optimum wearing schedule. This project was a preliminary investigation of customized soft toric c... Purpose: Reasons for the lack of success for contact lens patients range from poor fit, to discomfort or to a less than optimum wearing schedule. This project was a preliminary investigation of customized soft toric contact lenses as an alternative for unsuccessful contact lens patients or potential drop-outs. Methods: Fifteen healthy non-compromised, previously unsuccessful contact lens wearing patients (13 women, 2 men) with ages from 21 to 33 years (25.1 ± 2.7 years) were the subjects for this study. They were empirically fitted with 15 astigmatic and 5 spherical customized SpecialEyes soft contact lenses. Visual acuities, comfort, lens movement, and rotation were evaluated. Results: Patients fitted with customized SpecialEyes soft contact lenses had statistically significant better visual acuities than with Phoropter Manifest Refraction. The lenses used in this study centered well and moved no more than 1 mm upon each blink. Lens rotation was less than 10 degrees for all toric lenses. Patients gave very positive vision and comfort ratings. Conclusion: This preliminary study supports the application of a software program to empirically design and manufacture Special Eyes custom soft lenses based upon corneal topographical parameters and subjective manifest refraction for those patients who either have challenging corneal parameters, high sphero-cylindrical prescriptions, or are currently dissatisfied with their contact lenses and are potential drop-outs. 展开更多
关键词 Soft contact lenses CUSTOM contact lenses TORIC contact lenses contact lenses for ASTIGMATISM Empirical contact lens FITTING
下载PDF
ZERNIKE ASTIGMATISM AND VISUAL PERFORMANCE IN MYOPIC EYES BY RIGID GAS PERMEABLE CONTACT LENSES WEAR
15
作者 JINHUA BAO XINJIE MAO +2 位作者 HAIRONG WANG JI CHE FAN LU 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2012年第3期8-14,共7页
To investigate the effects of rigid-gas-permeable contact lens(RGP-CL)wear on Zernike astigmatism and visual performance in myopic eyes.Methods:A wavefront sensor was used to evaluate Zernike astigmatism for 21 eyes w... To investigate the effects of rigid-gas-permeable contact lens(RGP-CL)wear on Zernike astigmatism and visual performance in myopic eyes.Methods:A wavefront sensor was used to evaluate Zernike astigmatism for 21 eyes with minimum astigmatism and 18 eyes with moderate astigmatism under three different modes of refractive correction:the RGP-CL,spectacle lens correcting spherical equivalent(SL)and spectacle lens fully correcting spherical error and astigmatism(fSL).Contrast visual acuity was assessed with a VA tester at four contrast levels and two luminance backgrounds.Results:Compared to the SL wear,RGP-CL wear changed the main axis astigmatism(Z_(2)^(2))from0:09-0:34 to 0.34-0.22 for the minimum astigmatism group,while the contrast VA was improved about 0.05 LogMAR(F=8:06,p<0:01).For the group with moderate astigmatism,significant reduction in Z_(2)^(2)was found for both fSL wear(t=4:78,p<0:001)and RGP-CL wear(t=6:29,p<0:0001).The changes in astigmatism were significantly correlated between the fSL and RGP-CL wears(r=0:897,p<0:0001 for Z_(2)^(-2);and r=0:643,p=0:004 for Z_(2)^(2)).Contrast VA was significantly improved for both fSL and RGP-CL wears and the improvements were significantly correlated between each other for all four contrast levels and two backgrounds.Conclusion:RGP-CL wear induces astigmatism for the eyes with minor astigmatism probably due to a correction of corneal astigmatism and thus a manifesting of the lens astigmatism.For the astigmatic eyes,RGP-CL wear has similar effect on correcting astigmatism as the spectacle lens wear with spherical-cylinder correction and also produces similar visual improvement. 展开更多
关键词 Wavefront aberration Zernike aberration contrast visual acuity rigid-gas-permeable contact lens spectacle lens
下载PDF
Oxygen permeability of soft contact lenses in different pH, osmolality and buffering solution
16
作者 Se Eun Lee So Ra Kim Mijung Park 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第5期1037-1042,共6页
AIMTo determine the effect of pH, osmolality, and buffering system on the oxygen permeability (Dk) of soft contact lenses.METHODSTwo hydrogel lenses (nelfilcon A and etafilcon A) and 2 silicone hydrogel lenses (lotraf... AIMTo determine the effect of pH, osmolality, and buffering system on the oxygen permeability (Dk) of soft contact lenses.METHODSTwo hydrogel lenses (nelfilcon A and etafilcon A) and 2 silicone hydrogel lenses (lotrafilcon A and balafilcon A) were used in the study. These lenses were incubated in phosphate-buffered saline (PBS) and borate-buffered saline (BBS) solutions adjusted by 0.8 pH increments to a pH in the range of 5.8-9.0 or in hypotonic (280 mOsmol/kg), isotonic (310 mOsmol/kg) and hypertonic (380 mOsmol/kg) PBS solutions. Polarographic method was used for measuring the Dk and lenses were stacked as 4 layers to correct the boundary effect.RESULTSDk values of all contact lenses measured in BBS solutions were more stable than those in PBS solutions. Especially the etafilcon A lens showed a relative big change compared with other types of contact lenses at the same conditions. When the osmolality of PBS solution increased from hypotonic to hypertonic, Dk of all contact lenses decreased. Variations in Dk existed depending on lens materials, etafilcon A lens was the most affected and nelfilcon A was the least affected by osmolality.CONCLUSIONFrom the result obtained, it is revealed that Dk of contact lenses is changed by the pH, osmolality, and buffering condition of tear. Thus, Dk of contact lens can be varied by the lens wearers' physiological and/or pathological conditions. 展开更多
关键词 soft contact lens oxygen permeability buffer solutions OSMOLALITY PH
下载PDF
Corneal Wavefront Aberrations in Patients Wearing Multifocal Soft Contact Lenses for Myopia Control
17
作者 Frank Spors Donald J. Egan +3 位作者 Jie Shen Lance E. McNaughton Stuart Mann Neil M. Patel 《Open Journal of Ophthalmology》 2012年第3期45-53,共9页
Purpose: The purpose of this study was to evaluate the change in corneal wavefront aberrations in young adults who have been fit with multifocal soft contact lenses for myopia progression control. Findings have been a... Purpose: The purpose of this study was to evaluate the change in corneal wavefront aberrations in young adults who have been fit with multifocal soft contact lenses for myopia progression control. Findings have been analyzed for statistical significance and clinical relevance and compared to reportedly successful Orthokeratology outcomes. Methods: The dominant eye of 40 participants (27 women, 13 men;mean age 27.3 ± 3.2 years;range 23 to 39 years) was fit with Proclear Multifocal center distance lenses (Coopervision, Pleasanton, USA) having a variety of distance powers and reading additions. Refractive errors were limited to a range of –6.00 D up to +1.00 D of sphere, and no greater than –1.00 D of cylinder. Corneal wavefront measurements were performed over 6 mm diameters with a Zeiss Atlas 9000 corneal topographer (Zeiss Meditec, Dublin, USA) prior to, and following lens fitting. Data were converted into rectangular Fourier optics terms M, J0, J45 and RMS values for each reading addition were statistically analyzed. Following evaluation of statistical significance and clinical relevance, results were compared to published data from successful Orthokeratology treatments. Results: Statistically significant changes in higher order aberrations were detected for lenses of all reading additions. Lens groups with higher Add-powers demonstrated stronger changes with increased significance. Final RMS values relating to 2nd, 3rd and 4th Zernike Orders reached clinical significance with a wavefront error of 0.10 μm, the equivalent of 0.25D. Moreover, as Add-powers increased, 3rd and 4th order aberrations likewise showed an increase. Pre-fitting astigmatism values accounted for the highest recorded aberrations and remained predominantly unchanged. Conclusion: Proclear Multifocal center-distance contact lenses were found to increase higher order wavefront aberrations in a manner dependent on their Add-power. In comparison to successful Orthokeratology outcomes, the amounts of resulting aberrations are notably different. 展开更多
关键词 MULTIFOCAL Soft contact lenses Wavefront Aberrations MYOPIA MYOPIA Progression CONTROL ORTHOKERATOLOGY ZERNIKE Polynomials
下载PDF
A survey of corneal changes caused by daily wear silicone hydrogel contact lenses
18
作者 Beata Kettesy Julianna Vardai +2 位作者 Andras Berta Laszlo Modis Jr. Adam Kemeny-Beke 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2015年第6期92-100,共9页
The examination of the effects of second generation lotra filcon B silicone hydrogel(SiH)lenses on the cornea when worn for three years of daily wear.Material and Methods:55 healthy patients were divided into two grou... The examination of the effects of second generation lotra filcon B silicone hydrogel(SiH)lenses on the cornea when worn for three years of daily wear.Material and Methods:55 healthy patients were divided into two groups:current hydrogel contact lens wearers refitted with lotrafilcon B lenses(Group 1;28 patients)and neophyte contact lens wearers(Group 2;27 patients).Each patient's subjective eye comfort was measured with a self-administered questionnaire.The corneas were analyzed using contact specular microscope to measure corneal thickness and the endothelium before the SiH lenses werefitted after four weeks,one month,six months,one year,two years,and three years of lens wear.Results:Subjective complaints of patients in Group 1 were reduced;however patients in Group 2 experienced discomfort during the first two to four weeks of use.In Group 1,objective examinations identified a decrease in endothelial cell density.In Group 2,the endothelial cell density increased slightly in the first two years but decreased after three years.The results indicate that lotra filcon B slows down the deleterious effects of contact lenses.The coe±cient of variation significantly decreased after six months in Group 1(0.47 vs 0.44;p?0:049),whereas,in Group 2,the hexagonal cells improved significantly after one month(27.78 vs 28.25;p=0.025).Conclusion:Based on the subjects involved and the period of time under examination,it can be concluded that high-Dk SiH lenses support the physiological metabolism and functions of the cornea by improving oxygen provision. 展开更多
关键词 contact lens corneal endothelium silicone hydrogels specular microscopy cell density
下载PDF
Comparison of efficacy of two different silicone hydrogel bandage contact lenses after T-PRK
19
作者 Hua Li Ting Shao +3 位作者 Jia-Fan Zhang Lin Leng Sai Liu Ke-Li Long 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第2期299-305,共7页
AIM:To compare the efficacy between two different silicone hydrogel bandage contact lenses after transepithelial photorefractive keratectomy(T-PRK).METHODS:In this randomized controlled trial,a total of 89 patients(17... AIM:To compare the efficacy between two different silicone hydrogel bandage contact lenses after transepithelial photorefractive keratectomy(T-PRK).METHODS:In this randomized controlled trial,a total of 89 patients(178 eyes) who underwent T-PRK at the Qingdao Eye Hospital from October to December 2019 were selected.One random eye wore a Senofilcon A bandage contact lens after surgery,and the other eye a Balafilcon A bandage contact lens.Pain scores,uncorrected visual acuity(UCVA),spherical equivalent(SE),corneal epithelial healing status,epithelial thickness,bandage lenses deposits,lenses movement,and ocular surface conditions were measured and compared.RESULTS:There were no differences between the two groups in UCVA,SE,corneal epithelial healing status,corneal epithelial thickness,tear river heights and tear film rupture time at each follow-up visit.However,postoperative pain scores in the Senofilcon A group were significantly lower than those of the Balafilcon A group(F_(intergroups)=67.833,P<0.001;F_(time)=383.773,P<0.001;F_(interaction)=57.344,P<0.001).The duration of pain in eyes in the Senofilcon A group was shorter than that of the Balafilcon A group(t=-3.326,P=0.001).The surface deposition scores and movement scores of Senofilcon A bandage lenses on the first and fourth days after surgery were lower than those of Balafilcon A bandage lenses(Z=-5.385,-6.782,P<0.001;Z=-8.336,-8.906,P<0.001).CONCLUSION:Both Senofilcon A and Balafilcon A bandage lenses have good efficacy after T-PRK.Senofilcon A lenses are associated with less pain and more comfort compared to Balafilcon A. 展开更多
关键词 transepithelial photorefractive keratectomy bandage contact lenses corneal epithelium PAIN clinical results
下载PDF
Optical Modeling and Analysis of Peripheral Optics of Contact Lenses
20
作者 Jie Shen Frank Spors 《Open Journal of Ophthalmology》 2012年第3期54-59,共6页
Background: Degraded peripheral vision has been hypothesized to be a stimulus for the development of foveal refractive error. Contact lenses have been widely used to correct central vision, but their impacts on periph... Background: Degraded peripheral vision has been hypothesized to be a stimulus for the development of foveal refractive error. Contact lenses have been widely used to correct central vision, but their impacts on peripheral vision are still unknown. The purpose of this study was to use optical model software to evaluate the peripheral optics of rigid gas permeable (RGP) and soft contact lenses (SCLs) in isolation. This will better assist us in understanding their peripheral optical performances on human eyes. Methods: An optical design software package (Zemax EE) was used to model peripheral optics of Menicon RGP lens and Acuvue 2 SCLs. Profiles of sphero-cylindrical power and major higher-order aberrations were computed in 10osteps out to 40o off-axis eccentricity for –3.0 D central focal power contact lens. The results of optical modeling were analyzed and compared with previously published experimental data. Results: –3.0 D RGP lenses and SCLs had –1.4 D and –2.0 D dioptric power at 40o eccentricity, respectively. The reduced dioptric power in the periphery of the analyzed contact lenses quantitatively matched with the reduced amount of hyperopic field curvature found from experimental data when these contact lenses fitted on human eyes. Cylindrical power increased to 0.3 D ~ 0.4 D at 40o eccentricity for both lens types. In addition, both contact lens types produced higher order aberrations, namely 1.2 μm coma and 0.15 μm spherical aberration at 40o eccentricity. Conclusions: Compared to SCLs, RGP lenses with equal focal power had less dioptric power in the periphery. Both RGP lenses and SCLs produced the same amount of major higher-order aberrations with increasing of the field angle. Some of these results can be used to predict and understand the peripheral optical performance of contact lenses on human eyes. 展开更多
关键词 contact lens PERIPHERAL OPTICS ABERRATIONS OPTICAL Model
下载PDF
上一页 1 2 17 下一页 到第
使用帮助 返回顶部