Objective: To carry out empirical research on the role of project-achieving quality control circle (QCC) in constructing a new model of contactless medical service for outpatients. Methods: A QCC, consisting of inform...Objective: To carry out empirical research on the role of project-achieving quality control circle (QCC) in constructing a new model of contactless medical service for outpatients. Methods: A QCC, consisting of information office members from a grade A tertiary hospital in Wenzhou, was established to conduct a research project with the theme “Constructing a new model of contactless medical service based on outpatients’ experience.” According to the ten steps and PDCA cycle, an analysis was carried out before and after the QCC activities, focusing on improving pre-consultation services, providing steward-like services, and facilitating post-consultation management. Results: After the QCC activities, the mobile appointment rate, missed appointment rate, the proportion of smart check-ins, and the average check-in time were 55.68%, 4.02%, 39.75%, and 8.24 ± 3.66 min, respectively;in contrast, before the activities, they were 32.00%, 7.88%, 0.00%, and 14.96 ± 4.98 min, respectively;the difference between the two groups was statistically significant (χ2 = 3480.112, 4994.496;Fisher’s exact probability = 963788.570;t = 5.323, P < 0.001). Many experts have also visited the hospital to learn about this system, thus rendering social and economic benefits. Conclusion: Project-achieving QCC activities are suitable for complex situations, such as constructing a new model of contactless medical service, and can significantly improve outpatient service quality, enhance patients’ experience, and improve the abilities of circle members.展开更多
The sensitivity of contactless ultrasonic sensor is improved from 3.3% to 26% through acoustic and electric matching technique in this paper.Along dual crest lines auto seam tracking is firstly realized with contactle...The sensitivity of contactless ultrasonic sensor is improved from 3.3% to 26% through acoustic and electric matching technique in this paper.Along dual crest lines auto seam tracking is firstly realized with contactless ultrasonic sensing.The focused acoustic lens is accurately designed, and a sonic beam with 0.5 mm in diameter is achieved. By means of software and hardware technique the accuracy of seam tracking with ultrasonic sensing is 0.5 mm in lateral direction and 0.2 mm in longitudinal direction respectively.展开更多
A new method for the determination of arecoline in Semen Arecae decoction pieces by microchip capillary electrophoresis with contactless conductivity detection (MCE-CCD) was proposed. The effects of various electrop...A new method for the determination of arecoline in Semen Arecae decoction pieces by microchip capillary electrophoresis with contactless conductivity detection (MCE-CCD) was proposed. The effects of various electrophoretic operating parameters on the analysis of arecoline were studied. Under the optimal conditions, arecoline was rapidly separated and detected in 1 rain with good linearity over the concentration range of 20 1500 uM (r2=0.9991) and the detection limit of 5 uM (S/N=3). The method was used for the analysis of arecoline satisfactorily with a recovery of 96.8 -104%.展开更多
This paper reported a compact system of capacitively coupled contactless conductivity detection (C4D) based on the square wave excitation voltage for capillary electrophoresis, and it exhibited excellent sensitivity...This paper reported a compact system of capacitively coupled contactless conductivity detection (C4D) based on the square wave excitation voltage for capillary electrophoresis, and it exhibited excellent sensitivity at the optimal frequency of 198 kHz. The feasibility and sensitivity of this detector was demonstrated by simultaneous detection of thirteen ions including alkali, alkaline earth and heavy metal ions. And the detection limits (S/N 3) were in the range of 0.2-1μmol/L for Mn^2+, K^+, Na^+, Mg^2+, Ca^2+, Li^+, Ba^2+, and 7-25 μmol/L for Ni^2+, Cu^2+, Cd^2+, Pb^2+, Co^2+, Zn^2+.展开更多
文摘Objective: To carry out empirical research on the role of project-achieving quality control circle (QCC) in constructing a new model of contactless medical service for outpatients. Methods: A QCC, consisting of information office members from a grade A tertiary hospital in Wenzhou, was established to conduct a research project with the theme “Constructing a new model of contactless medical service based on outpatients’ experience.” According to the ten steps and PDCA cycle, an analysis was carried out before and after the QCC activities, focusing on improving pre-consultation services, providing steward-like services, and facilitating post-consultation management. Results: After the QCC activities, the mobile appointment rate, missed appointment rate, the proportion of smart check-ins, and the average check-in time were 55.68%, 4.02%, 39.75%, and 8.24 ± 3.66 min, respectively;in contrast, before the activities, they were 32.00%, 7.88%, 0.00%, and 14.96 ± 4.98 min, respectively;the difference between the two groups was statistically significant (χ2 = 3480.112, 4994.496;Fisher’s exact probability = 963788.570;t = 5.323, P < 0.001). Many experts have also visited the hospital to learn about this system, thus rendering social and economic benefits. Conclusion: Project-achieving QCC activities are suitable for complex situations, such as constructing a new model of contactless medical service, and can significantly improve outpatient service quality, enhance patients’ experience, and improve the abilities of circle members.
文摘The sensitivity of contactless ultrasonic sensor is improved from 3.3% to 26% through acoustic and electric matching technique in this paper.Along dual crest lines auto seam tracking is firstly realized with contactless ultrasonic sensing.The focused acoustic lens is accurately designed, and a sonic beam with 0.5 mm in diameter is achieved. By means of software and hardware technique the accuracy of seam tracking with ultrasonic sensing is 0.5 mm in lateral direction and 0.2 mm in longitudinal direction respectively.
基金support from the National Natural Science Foundation of China (Nos. 20727006,21075139)Guangdong Provincial Science and Technology Project (2008A030102009)the Medical Scientific Research Foundation of Guangdong Province(A2012155)
文摘A new method for the determination of arecoline in Semen Arecae decoction pieces by microchip capillary electrophoresis with contactless conductivity detection (MCE-CCD) was proposed. The effects of various electrophoretic operating parameters on the analysis of arecoline were studied. Under the optimal conditions, arecoline was rapidly separated and detected in 1 rain with good linearity over the concentration range of 20 1500 uM (r2=0.9991) and the detection limit of 5 uM (S/N=3). The method was used for the analysis of arecoline satisfactorily with a recovery of 96.8 -104%.
基金support from the National Natural Science Foundation of China(No.20475018)the Key Program of Guangdong Natural Science Foundation(No.05103552)
文摘This paper reported a compact system of capacitively coupled contactless conductivity detection (C4D) based on the square wave excitation voltage for capillary electrophoresis, and it exhibited excellent sensitivity at the optimal frequency of 198 kHz. The feasibility and sensitivity of this detector was demonstrated by simultaneous detection of thirteen ions including alkali, alkaline earth and heavy metal ions. And the detection limits (S/N 3) were in the range of 0.2-1μmol/L for Mn^2+, K^+, Na^+, Mg^2+, Ca^2+, Li^+, Ba^2+, and 7-25 μmol/L for Ni^2+, Cu^2+, Cd^2+, Pb^2+, Co^2+, Zn^2+.