期刊文献+

二次检索

题名
关键词
文摘
作者
第一作者
机构
刊名
分类号
参考文献
作者简介
基金资助
栏目信息

年份

共找到2篇文章
< 1 >
每页显示 20 50 100
Resistance Measurements and Interpretations Relating to Flashover of Artificially Contaminated Ceramic Insulator Strings
1
作者 B.SubbaReddy G.R.Nagabhushana 《Plasma Science and Technology》 SCIE EI CAS CSCD 2003年第6期2093-2100,共8页
The flashover of insulator strings occurring at normal working voltages undercontaminated/polluted conditions, obviously deserves serious consideration. Though much researchhas been gone into pollution-induced flashov... The flashover of insulator strings occurring at normal working voltages undercontaminated/polluted conditions, obviously deserves serious consideration. Though much researchhas been gone into pollution-induced flashover phenomena but grey areas still exist in ourknowledge. In the present experimental study the breakdown (flashover) voltages across gaps oninsulator top surfaces and gaps between sheds (on the underside of an insulator), also the flashoverstudies on a single unit and a 3-unit insulator strings were carried out. An attempt has been madeto correlate the values obtained for all the cases. From the present investigation it was found thatresistance measurement of individual units of a polluted 3-unit string before and after flashoverindicates that strongly differing resistances could be the cause of flashover of ceramic discinsulator strings. 展开更多
关键词 artificially contaminated/polluted insulator strings resistancemeasurements insulator flashover breakdown voltages ceramic insulators
下载PDF
户外绝缘子积污特性的试验与仿真(英文) 被引量:9
2
作者 顾春晖 李江涛 +3 位作者 张磊洲 李孟 肖嵘 钱之银 《高电压技术》 EI CAS CSCD 北大核心 2011年第11期2822-2829,共8页
Flashover on polluted insulators is the most common accident occuring in power system.A great amount of work has been done to study the flashover characteristics on various kinds of insulators with several theoretical... Flashover on polluted insulators is the most common accident occuring in power system.A great amount of work has been done to study the flashover characteristics on various kinds of insulators with several theoretical models proposed.In these models,the amount and the distribution of the pollution on the insulator is critical to the flashover performance.However,very few simulation works has been carried out to study the pollution accumulation characteristics on the insulators.In this paper,both experimental and numerical efforts were given to study the pollution accumulation characteristics in order to evaluate the flashover probability.Experiments were performed first to have a bird view on the overall pollution distributions considering several crucial influential factors such as the wind speed and wind direction.AC porcelain insulators(XWP_2-160 type) were selected as the experimental samples and the equivalent salt deposit density(ESDD) was measured after the total predetermined amount of pollution was reached.Then, aerodynamic simulation was carried out to study the airflow and velocity distributions on each part of the insulator in clean air with regard to different wind speed and direction.It was found that the amount of the pollution on each section of the insulator has clear connections to the wind speed or air pressure distribution on the insulator surface.These distributions coincide to the pollution distribution obtained from experiments.Besides,the wind speed and air pressure distribution along the insulator chain was also studied.This work has shown that the numerical simulation may predict the pollution distribution on the insulators with practical accuracy.It is also possible to design new insulator shapes to reduce the pollution accumulation on critical areas according to the analysis in this work. 展开更多
关键词 artificial contamination test characteristic of flow field FLUENT insulator contamination numerical simulation XWP2-160 insulator
下载PDF