A heat transfer model on the solidification process has been established onthe basis of the technical conditions of the slab caster in No.3 steel works of Wuhan Iron & SteelCorporation, and the temperature field i...A heat transfer model on the solidification process has been established onthe basis of the technical conditions of the slab caster in No.3 steel works of Wuhan Iron & SteelCorporation, and the temperature field in the solidifying slab was calculated which was verified bythe measured slab surface temperature. The influences of the main operating factors includingcasting speed, spray cooling patterns, superheat of melt and slab size on the solidification processwere analyzed and the means of enhancing the slab temperature was brought forward. Raising thecasting speed to 1.3 m/min, controlling the flowrate of secondary cooling water and improving thecooling pattern at the lower segments of secondary cooling zone could improve the slab temperatureeffectively. And the increasing the superheat is adverse to the production of high temperature slab.展开更多
An unsteady, two-dimensional, explicitly solved fmite difference heat transfer model of a billet caster was presented to clarify the influence of the thermal conductivity of steel on model accuracy. Different approach...An unsteady, two-dimensional, explicitly solved fmite difference heat transfer model of a billet caster was presented to clarify the influence of the thermal conductivity of steel on model accuracy. Different approaches were utilized for calculating the thermal conductivity of solid, mushy and liquid steels. Model results predicted by these approaches were compared, and the advantages of advocated approaches were discussed. It is found that the approach for calculating the thermal conductivity of solid steel notably influences model predictions. Convection effects of liquid steel should be considered properly while calculating the thermal conductivity of mushy steel. Different values of the effective thermal conductivity of liquid steel adopted could partly be explained by the fact that different models adopted dissimilar ap- proaches for calculating the thermal conductivity of solid and mushy steels.展开更多
Continuous casting of steel involving different grades in the same casting sequence remains a challenge to billet caster operators. The intermixed composition obtained during the grade change does not meet the specifi...Continuous casting of steel involving different grades in the same casting sequence remains a challenge to billet caster operators. The intermixed composition obtained during the grade change does not meet the specification of either grade and must be downgraded. Incorrect identification of this intermixed region may result in non-conforming products reaching the customer. In this study, a numerical model based on CFD (computational fluid dynamics approach) has been developed which predicts the start and end of the intermixed composition and the tonnage to be downgraded under different casting conditions. This model was validated and the results were in good agreement with the actual plant data for a 6-strand billet caster at LD-1 of TATA Steel, India. This model is used to calculate transition tonnage for different scenarios, e.g. when one of the outermost strands is not functional or some combinations are not functional and varying casting speed during operation. Furthermore, impact of different design of baffles on performance of Tundish has been evaluated to find a way to reduce transition or intermixed composition.展开更多
基金This work was financially sponsored by Jiangsu Youth Science Foundation (No.JDQ2001003).
文摘A heat transfer model on the solidification process has been established onthe basis of the technical conditions of the slab caster in No.3 steel works of Wuhan Iron & SteelCorporation, and the temperature field in the solidifying slab was calculated which was verified bythe measured slab surface temperature. The influences of the main operating factors includingcasting speed, spray cooling patterns, superheat of melt and slab size on the solidification processwere analyzed and the means of enhancing the slab temperature was brought forward. Raising thecasting speed to 1.3 m/min, controlling the flowrate of secondary cooling water and improving thecooling pattern at the lower segments of secondary cooling zone could improve the slab temperatureeffectively. And the increasing the superheat is adverse to the production of high temperature slab.
基金financially supported by the National Natural Science Foundation of China(No.51074019)
文摘An unsteady, two-dimensional, explicitly solved fmite difference heat transfer model of a billet caster was presented to clarify the influence of the thermal conductivity of steel on model accuracy. Different approaches were utilized for calculating the thermal conductivity of solid, mushy and liquid steels. Model results predicted by these approaches were compared, and the advantages of advocated approaches were discussed. It is found that the approach for calculating the thermal conductivity of solid steel notably influences model predictions. Convection effects of liquid steel should be considered properly while calculating the thermal conductivity of mushy steel. Different values of the effective thermal conductivity of liquid steel adopted could partly be explained by the fact that different models adopted dissimilar ap- proaches for calculating the thermal conductivity of solid and mushy steels.
文摘Continuous casting of steel involving different grades in the same casting sequence remains a challenge to billet caster operators. The intermixed composition obtained during the grade change does not meet the specification of either grade and must be downgraded. Incorrect identification of this intermixed region may result in non-conforming products reaching the customer. In this study, a numerical model based on CFD (computational fluid dynamics approach) has been developed which predicts the start and end of the intermixed composition and the tonnage to be downgraded under different casting conditions. This model was validated and the results were in good agreement with the actual plant data for a 6-strand billet caster at LD-1 of TATA Steel, India. This model is used to calculate transition tonnage for different scenarios, e.g. when one of the outermost strands is not functional or some combinations are not functional and varying casting speed during operation. Furthermore, impact of different design of baffles on performance of Tundish has been evaluated to find a way to reduce transition or intermixed composition.