The physical model of a ten-strand billet caster tundish was established to study the effects of various flow control devices on the melt flow. Before and after the optimization of the melt flow, the inclusion removal...The physical model of a ten-strand billet caster tundish was established to study the effects of various flow control devices on the melt flow. Before and after the optimization of the melt flow, the inclusion removal in the tundish was evaluated by plant trials. The physical modeling results show that when combined with a baffle, the turbulence inhibitor, instead of the impact pad, can significantly improve the melt flow. A turbulence inhibitor with a longer length of inner cavity and without an extending lip at the top of the sidewall seems to be efficient in the improvement of the melt flow. Various types and designs of baffles all influence the flow characteristics significantly. The "V" type baffles are better than the straight baffles for flow control. The "V" type baffle with four inclined holes at the sidewall away from the stopper rods is better in melt flow control than the one with one inclined hole at each sidewall. The combination of a well-designed turbulence inhibitor and an appropriate baffle shows high efficiency on improving the melt flow and an optimal proposal was presented. Plant trials indicate that, compared with the original tundish configuration in prototype, the inclusions reduce by 42% and the inclusion distribution of individual strands is more similar with the optimal one. The optimal tundish configuration effectively improves the melt flow in the ten-strand billet caster tundish.展开更多
Fields of fluid flow and temperature, and residence time distribution(RTD) curves were investigated by mathematical simulation in a one-strand tundish for continuous casting. It was known from the investigation that a...Fields of fluid flow and temperature, and residence time distribution(RTD) curves were investigated by mathematical simulation in a one-strand tundish for continuous casting. It was known from the investigation that a big "spring uprush" formed on surface around the long shroud when molten steel flowed into a turbulence inhibitor(TI) with extending lips and rushed up reversely out of the TI, while four small "spring uprushes" existed on surface when a TI without extending lips because the liquid steel flowed mainly out of the 4 corners of the TI. The flow of liquid steel in the former tundish configuration was not reasonable and the height of an area where temperature was less than 1819 K was about half of liquid surface height on the right side of the stopper, which meant that big dead zone existed in the former tundish configuration. In the optimal one, the height of such area was only seventh of the liquid surface height. The RTD curves obtained from the mathematical simulation basically agreed with those from the physical modeling and the flow characteristics obtained from these two methods agreed with each other.展开更多
基金supported by the National Natural Science Foundation of China(No.51474059,No.51204042)the Program for Liaoning Excellent Talents in University(No.LJQ2014031)the Fundamental Research Funds for the Central Universities(No.N140205003)
文摘The physical model of a ten-strand billet caster tundish was established to study the effects of various flow control devices on the melt flow. Before and after the optimization of the melt flow, the inclusion removal in the tundish was evaluated by plant trials. The physical modeling results show that when combined with a baffle, the turbulence inhibitor, instead of the impact pad, can significantly improve the melt flow. A turbulence inhibitor with a longer length of inner cavity and without an extending lip at the top of the sidewall seems to be efficient in the improvement of the melt flow. Various types and designs of baffles all influence the flow characteristics significantly. The "V" type baffles are better than the straight baffles for flow control. The "V" type baffle with four inclined holes at the sidewall away from the stopper rods is better in melt flow control than the one with one inclined hole at each sidewall. The combination of a well-designed turbulence inhibitor and an appropriate baffle shows high efficiency on improving the melt flow and an optimal proposal was presented. Plant trials indicate that, compared with the original tundish configuration in prototype, the inclusions reduce by 42% and the inclusion distribution of individual strands is more similar with the optimal one. The optimal tundish configuration effectively improves the melt flow in the ten-strand billet caster tundish.
基金Item Sponsored by Key Project of National Natural Science Foundation of China(61333006)
文摘Fields of fluid flow and temperature, and residence time distribution(RTD) curves were investigated by mathematical simulation in a one-strand tundish for continuous casting. It was known from the investigation that a big "spring uprush" formed on surface around the long shroud when molten steel flowed into a turbulence inhibitor(TI) with extending lips and rushed up reversely out of the TI, while four small "spring uprushes" existed on surface when a TI without extending lips because the liquid steel flowed mainly out of the 4 corners of the TI. The flow of liquid steel in the former tundish configuration was not reasonable and the height of an area where temperature was less than 1819 K was about half of liquid surface height on the right side of the stopper, which meant that big dead zone existed in the former tundish configuration. In the optimal one, the height of such area was only seventh of the liquid surface height. The RTD curves obtained from the mathematical simulation basically agreed with those from the physical modeling and the flow characteristics obtained from these two methods agreed with each other.