To develop technically feasible and economically favorable dynamic process control(DPC)strategies for an alternating activated sludge(AAS)system,a bench-scale continuous-flow alternating aerobic and anoxic reactor,per...To develop technically feasible and economically favorable dynamic process control(DPC)strategies for an alternating activated sludge(AAS)system,a bench-scale continuous-flow alternating aerobic and anoxic reactor,performing short-cut nitrogen removal from real domestic wastewater was operated under different control strategies for more than five months.A fixed-time control(FTC) study showed that bending-points on pH and oxidation-reduction potential(ORP)profiles accurately coincided with the major biologic...展开更多
Aerobic granules were formed in a conven- tional, continuous flow, completely mixed activated sludge system (CMAS). The reactor was inoculated with seed sludge containing few filaments and fed with synthetic municip...Aerobic granules were formed in a conven- tional, continuous flow, completely mixed activated sludge system (CMAS). The reactor was inoculated with seed sludge containing few filaments and fed with synthetic municipal wastewater. The settling time of the sludge and the average dissolved oxygen (DO) of the reactor were 2 h and 4.2 mg. L 1, respectively. The reactor was agitated by a stirrer, with a speed of 250r·min^-1, to ensure good mixing . The granular sludge had good settleability, and the sludge volume index (SVI) was between 50 and 90 mL ·g ^-1. The laser particle analyzer showed the diameter of the granules to be between 0.18 and 1.25 mm. A scanning electron microscope (SEM) investigation revealed the predominance of sphere-like and rod-like bacteria, and only few filaments grew in the granules. The microbial community structure of the granules was also analyzed by polymerase chain reaction-denaturing gradient gel electro- phoresis (PCR-DGGE). Sequencing analysis indicated the dominant species were α, β, and γ-Proteobacteria, Bacteroidetes, and Firmicutes. The data from the study suggested that aerobic granules could form, if provided with sufficient number of filaments and high shear force. It was also observed that a high height-to-diameter ratio of the reactor and short settling time were not essential for the formation of aerobic granular sludge.展开更多
文摘To develop technically feasible and economically favorable dynamic process control(DPC)strategies for an alternating activated sludge(AAS)system,a bench-scale continuous-flow alternating aerobic and anoxic reactor,performing short-cut nitrogen removal from real domestic wastewater was operated under different control strategies for more than five months.A fixed-time control(FTC) study showed that bending-points on pH and oxidation-reduction potential(ORP)profiles accurately coincided with the major biologic...
基金Acknowledgements This research was supported by the National Natural Science Foundation of China (Grant No. 50878180).
文摘Aerobic granules were formed in a conven- tional, continuous flow, completely mixed activated sludge system (CMAS). The reactor was inoculated with seed sludge containing few filaments and fed with synthetic municipal wastewater. The settling time of the sludge and the average dissolved oxygen (DO) of the reactor were 2 h and 4.2 mg. L 1, respectively. The reactor was agitated by a stirrer, with a speed of 250r·min^-1, to ensure good mixing . The granular sludge had good settleability, and the sludge volume index (SVI) was between 50 and 90 mL ·g ^-1. The laser particle analyzer showed the diameter of the granules to be between 0.18 and 1.25 mm. A scanning electron microscope (SEM) investigation revealed the predominance of sphere-like and rod-like bacteria, and only few filaments grew in the granules. The microbial community structure of the granules was also analyzed by polymerase chain reaction-denaturing gradient gel electro- phoresis (PCR-DGGE). Sequencing analysis indicated the dominant species were α, β, and γ-Proteobacteria, Bacteroidetes, and Firmicutes. The data from the study suggested that aerobic granules could form, if provided with sufficient number of filaments and high shear force. It was also observed that a high height-to-diameter ratio of the reactor and short settling time were not essential for the formation of aerobic granular sludge.