A flux linkage compensation field oriented control (FOC) method was proposed to suppress the speed and torque ripples of a brushless wound-field synchronous motor in its starting process. The starting process was anal...A flux linkage compensation field oriented control (FOC) method was proposed to suppress the speed and torque ripples of a brushless wound-field synchronous motor in its starting process. The starting process was analyzed and the model of wound-field synchronous electric machine was established. The change of field current of the electric machine was described mathematically for simplified exciter and rotate rectifier. Based on the traditional field control, the flux linkage compensation was introduced in d-axis current to counteract the flux ripple. Some simulation and preliminary experiments were implemented. The results show that the proposed method is feasible and effective.展开更多
In order to study the application of dual clutch transmission (DCT) on tracked vehicles, a simulation moclel and two control methods were performed for starting analysis. Based on a certain transmission of an existi...In order to study the application of dual clutch transmission (DCT) on tracked vehicles, a simulation moclel and two control methods were performed for starting analysis. Based on a certain transmission of an existing tracked vehicle, a DCT structure was proposed. Matlab/Simulink was a dopted as a platform to develop the simulation model. The engine speed was controlled to follow the target speed as a launch strategy. Two control methods, a proportional integral derivative ( PID ) control method and a fuzzy control method, were proposed to control the engine throttle and oil pressure in order to track the target engine speed. Simulation results show that either the PID control or fuzzy control method can improve the starting performance compared with no loop control meth od. Fuzzy control method can lead a better starting quality compared with PID control method.展开更多
Synchronous condensers(SCs)are generally used at the receiving-end stations of ultra-high-voltage direct current(UHVDC)transmission systems due to their strong reactive power support and flexible regulation of reactiv...Synchronous condensers(SCs)are generally used at the receiving-end stations of ultra-high-voltage direct current(UHVDC)transmission systems due to their strong reactive power support and flexible regulation of reactive power according to the interconnected grids operating conditions.In this paper,different starting control schemes of a SC integrated power grid are investigated providing four main contributions:1)The principle of reactive power support of the SC on the interconnected power grid is analytically studied,providing the establishment of mathematical models.2)Four different starting control schemes are developed for the initialization and SC integration,i.e.in Scheme 1,a preset initial falling speed is directly utilized without initialization;in Scheme 2,a black start sequential control approach with a static frequency converter(SFC)is proposed;in Scheme 3,PI/PD/PID controllers are respectively applied for the excitation device at the speed-falling stage;in Scheme 4,a pre-insertion approach of an energy absorption component with R/L/RL is utilized to suppress the surges at the SC integration instant.3)The dynamic behaviors of four different starting schemes at specific operating stages are evaluated.4)The success rate of SC integration is analyzed to evaluate starting control performance.Performance of the SC interconnected system with four different starting control schemes is evaluated in the timedomain simulation environment PSCAD/EMTDC^(TM).The results prove the superiority of the proposed starting control approach in Scheme 4.展开更多
After the trajectory simulation model of rudder control rocket with six degrees of freedom is established by Matlab/ Simulink, the simulated targeting of rudder control rocket with rudder angle error and starting cont...After the trajectory simulation model of rudder control rocket with six degrees of freedom is established by Matlab/ Simulink, the simulated targeting of rudder control rocket with rudder angle error and starting control moment error is carried out respectively by means of Monte Carlo method and the distribution of impact points of rudder control rocket is counted from all the successful subsamples. In the case of adding interference errors associated with rudder angle error and starting time error, the simulation analysis of impact point dispersion is done and its lateral and longitudinal correction abilities at different targeting angles are simulated to identify the effects of these factors on characteristics and control precision of the rudder control rocket, which provides the relevant reference for high-precision design of rudder control system.展开更多
Ultrasonic vibration feeding(UVF) method which can quantitatively feed and precisely deposit fine powder is a potential technique for micro feeding.The excitation sources transmit vibration to capillary though the t...Ultrasonic vibration feeding(UVF) method which can quantitatively feed and precisely deposit fine powder is a potential technique for micro feeding.The excitation sources transmit vibration to capillary though the third medium for most UVF devices.The vibrator is directly touched with the capillary can transmit mechanical energy on the capillary as much as possible,and the powder feeding can be controlled more precise.However,there are few reports about it.A direct UVF system which integrates the function of micro feeding,process observing,and powder forming was developed in this work.In order to analyze the effect of the system factors on feeding,a group of L9(3^3) orthogonal experiments are selected to confirm the effect of level change of factors.The three factors are capillary nozzle diameter,amplitude and signal.The flow rate was stable for each combined factors,and the optimum combination for the minimum flow rate are choosing small capillary,small amplitude,and triangular wave orderly.The whole process of feeding includes start point,middle stage and stop stage.Starting of feeding was synchronized to vibration when the amplitude of capillary nozzle is larger than critical amplitude.Then,the feeding process enters the middle stage,the feeding state is observed by the CCD,and it is very stable in the middle stage.Overflow of feeding can't be eliminated during the stop stage.The features of the deposited powder lines are analyzed; the overflow can be diminished by choosing small capillary and appropriate ratio of the capillary nozzle diameter to the particle size.Chinese characters lattices were deposited to validate the ability of quantitatively feeding and fixed feeding of UVF.Diameters of all powder dots show normal distribution,and more than 60% dots are concentrated from 550 μm to 650 μm,and the average diameter for all the dots is 597 μm.Most dots positions are well approached to their scheduled positions,and the maximum deviation is 0.27 mm.The new direct UVF system is used to implement experiments,which confirms the precise controllable of feeding.According improve the feeding technique,it suits well for rapid prototyping,chemistry,pharmaceutics and many other fields,which require precise measurement and feed minim powder.展开更多
In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response w...In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response when system starts up, the starting voltage prediction control and the current feed-forward control are proposed and used, which improve the dynamic performance of the system in the PAC.The experimental results carried out on a three-phase grid-connected inverter proved the validity of the proposed method.展开更多
We consider the problem of stabilization near zero of semilinear normal parabolic equations connected with the 3D Helmholtz system with periodic boundary conditions and arbitrary initial datum.This problem was previou...We consider the problem of stabilization near zero of semilinear normal parabolic equations connected with the 3D Helmholtz system with periodic boundary conditions and arbitrary initial datum.This problem was previously studied in Fursikov and Shatina(2018).As it was recently revealed,the control function suggested in that work contains a term impeding transferring the stabilization construction on the 3D Helmholtz system.The main concern of this paper is to prove that this term is not necessary for the stabilization result,and therefore the control function can be changed by a proper way.展开更多
基金Sponsored by the NSFC General Project (51177135)the Key Project of Natural Science Foundation of Shaanxi Province (2011GZ013)
文摘A flux linkage compensation field oriented control (FOC) method was proposed to suppress the speed and torque ripples of a brushless wound-field synchronous motor in its starting process. The starting process was analyzed and the model of wound-field synchronous electric machine was established. The change of field current of the electric machine was described mathematically for simplified exciter and rotate rectifier. Based on the traditional field control, the flux linkage compensation was introduced in d-axis current to counteract the flux ripple. Some simulation and preliminary experiments were implemented. The results show that the proposed method is feasible and effective.
基金Supported by Defense Advanced Research Support Project(62301030303)111 Project(B08043)
文摘In order to study the application of dual clutch transmission (DCT) on tracked vehicles, a simulation moclel and two control methods were performed for starting analysis. Based on a certain transmission of an existing tracked vehicle, a DCT structure was proposed. Matlab/Simulink was a dopted as a platform to develop the simulation model. The engine speed was controlled to follow the target speed as a launch strategy. Two control methods, a proportional integral derivative ( PID ) control method and a fuzzy control method, were proposed to control the engine throttle and oil pressure in order to track the target engine speed. Simulation results show that either the PID control or fuzzy control method can improve the starting performance compared with no loop control meth od. Fuzzy control method can lead a better starting quality compared with PID control method.
基金supported by the National Natural Science Foundation of China under Grant 51807091the Natural Science Foundation of Jiangsu Province BK20180478+2 种基金the China Postdoctoral Science Foundation under Grant 2019M661846the State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources under Grant LAPS20016Engineering and Physical Sciences Research Council under Grant EP/N032888/1.
文摘Synchronous condensers(SCs)are generally used at the receiving-end stations of ultra-high-voltage direct current(UHVDC)transmission systems due to their strong reactive power support and flexible regulation of reactive power according to the interconnected grids operating conditions.In this paper,different starting control schemes of a SC integrated power grid are investigated providing four main contributions:1)The principle of reactive power support of the SC on the interconnected power grid is analytically studied,providing the establishment of mathematical models.2)Four different starting control schemes are developed for the initialization and SC integration,i.e.in Scheme 1,a preset initial falling speed is directly utilized without initialization;in Scheme 2,a black start sequential control approach with a static frequency converter(SFC)is proposed;in Scheme 3,PI/PD/PID controllers are respectively applied for the excitation device at the speed-falling stage;in Scheme 4,a pre-insertion approach of an energy absorption component with R/L/RL is utilized to suppress the surges at the SC integration instant.3)The dynamic behaviors of four different starting schemes at specific operating stages are evaluated.4)The success rate of SC integration is analyzed to evaluate starting control performance.Performance of the SC interconnected system with four different starting control schemes is evaluated in the timedomain simulation environment PSCAD/EMTDC^(TM).The results prove the superiority of the proposed starting control approach in Scheme 4.
文摘After the trajectory simulation model of rudder control rocket with six degrees of freedom is established by Matlab/ Simulink, the simulated targeting of rudder control rocket with rudder angle error and starting control moment error is carried out respectively by means of Monte Carlo method and the distribution of impact points of rudder control rocket is counted from all the successful subsamples. In the case of adding interference errors associated with rudder angle error and starting time error, the simulation analysis of impact point dispersion is done and its lateral and longitudinal correction abilities at different targeting angles are simulated to identify the effects of these factors on characteristics and control precision of the rudder control rocket, which provides the relevant reference for high-precision design of rudder control system.
基金supported by National Hi-tech Research and Development Program of China (863 Program, Grant No. 2008AA03A238)National Natural Science Foundation of China (Grant No. 51005186)Foundation for the Author of National Excellent Doctoral Dissertation of China (Grant No. 2007B39)
文摘Ultrasonic vibration feeding(UVF) method which can quantitatively feed and precisely deposit fine powder is a potential technique for micro feeding.The excitation sources transmit vibration to capillary though the third medium for most UVF devices.The vibrator is directly touched with the capillary can transmit mechanical energy on the capillary as much as possible,and the powder feeding can be controlled more precise.However,there are few reports about it.A direct UVF system which integrates the function of micro feeding,process observing,and powder forming was developed in this work.In order to analyze the effect of the system factors on feeding,a group of L9(3^3) orthogonal experiments are selected to confirm the effect of level change of factors.The three factors are capillary nozzle diameter,amplitude and signal.The flow rate was stable for each combined factors,and the optimum combination for the minimum flow rate are choosing small capillary,small amplitude,and triangular wave orderly.The whole process of feeding includes start point,middle stage and stop stage.Starting of feeding was synchronized to vibration when the amplitude of capillary nozzle is larger than critical amplitude.Then,the feeding process enters the middle stage,the feeding state is observed by the CCD,and it is very stable in the middle stage.Overflow of feeding can't be eliminated during the stop stage.The features of the deposited powder lines are analyzed; the overflow can be diminished by choosing small capillary and appropriate ratio of the capillary nozzle diameter to the particle size.Chinese characters lattices were deposited to validate the ability of quantitatively feeding and fixed feeding of UVF.Diameters of all powder dots show normal distribution,and more than 60% dots are concentrated from 550 μm to 650 μm,and the average diameter for all the dots is 597 μm.Most dots positions are well approached to their scheduled positions,and the maximum deviation is 0.27 mm.The new direct UVF system is used to implement experiments,which confirms the precise controllable of feeding.According improve the feeding technique,it suits well for rapid prototyping,chemistry,pharmaceutics and many other fields,which require precise measurement and feed minim powder.
基金supported by the Shanghai Education Committee Scientific Research Subsidization (Grant No.05AZ30)the Specialized Research Fund for the Doctoral Program of Higher Education (Grant No. 20060280018)
文摘In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response when system starts up, the starting voltage prediction control and the current feed-forward control are proposed and used, which improve the dynamic performance of the system in the PAC.The experimental results carried out on a three-phase grid-connected inverter proved the validity of the proposed method.
基金supported by the Ministry of Education and Science of the Russian Federation (Grant No. 14.Z50.31.0037)supported by the Russian Foundation for Basic Research (Grant Nos. 15-01-03576 and 15-01-08023)
文摘We consider the problem of stabilization near zero of semilinear normal parabolic equations connected with the 3D Helmholtz system with periodic boundary conditions and arbitrary initial datum.This problem was previously studied in Fursikov and Shatina(2018).As it was recently revealed,the control function suggested in that work contains a term impeding transferring the stabilization construction on the 3D Helmholtz system.The main concern of this paper is to prove that this term is not necessary for the stabilization result,and therefore the control function can be changed by a proper way.