期刊文献+
共找到15篇文章
< 1 >
每页显示 20 50 100
Development of OPTO-LDR coupled timer based voltage to frequency converter 被引量:1
1
作者 Akash Kumar Anindya Debnath +4 位作者 Antar Banik Kabirul Islam Mondal Partha Pratim Biswas Rik Bhattacharyya T K Maiti 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2017年第1期17-20,共4页
This paper describes the development of a timer based voltage to frequency converter(V FC).Timer LM555is used in astable multivibrator mode with two OPTO-LDRs(light dependent resistors)in the circuitry.The frequency o... This paper describes the development of a timer based voltage to frequency converter(V FC).Timer LM555is used in astable multivibrator mode with two OPTO-LDRs(light dependent resistors)in the circuitry.The frequency of timer output waveform which is measured using a digital storage oscillator(DSO)is almost linearly proportional to the applied input voltage.Hence we obtain a linear relationship between the frequency of timer output waveform and the input voltage.Because of its quasi-digital output,the main advantages of this developed converter are linear input-output relationship,small size,easy portabilityand high cost performance.In addition,the timer output waveform can be directly interfaced with personal computer or microprocessor/microcontroller for further processing of the input voltage signal without intervening any analog-to-digital converter(ADC). 展开更多
关键词 timer LM 555 astable multivibrator light emitting diode (LED) light dependent resistor (LDR) voltage to frequency converter (V FC) digital storage oscillator (DSO)
下载PDF
A linear-to-circular polarization converter based on I-shaped circular frequency selective surfaces
2
作者 吴家梁 林宝勤 +1 位作者 达新宇 吴凯 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第9期184-189,共6页
In this paper, a linear-to-circular polarization converter using a three-layer frequency selective surface based on Ishaped circular structure resonant is presented and investigated. Numerical simulations exhibit that... In this paper, a linear-to-circular polarization converter using a three-layer frequency selective surface based on Ishaped circular structure resonant is presented and investigated. Numerical simulations exhibit that when the normal ypolarized waves impinge on this device propagating towards +z direction, the two orthogonal components of the transmitted waves have a 90° phase difference as well as the nearly equal amplitudes at the resonant frequency of 7.04 GHz, which means that the left-hand circular polarization is realized in transmission. For validating the proposed design, a prototype which consists of 25 × 25 elements has been designed, manufactured and measured. The measured results are in good agreement with the simulated ones, showing that the polarization conversion transmission is over-3 dB in the frequency range of 5.22–8.08 GHz and the axial ratio is below 3 dB from 5.86 GHz to 7.34 GHz. 展开更多
关键词 polarization converter metasurface frequency selective surface
下载PDF
Bifurcation and chaos in high-frequency peak current mode Buck converter
3
作者 常昌远 赵欣 +1 位作者 杨帆 吴承恩 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第7期171-178,共8页
Bifurcation and chaos in high-frequency peak current mode Buck converter working in continuous conduction mode(CCM) are studied in this paper. First of all, the two-dimensional discrete mapping model is established.... Bifurcation and chaos in high-frequency peak current mode Buck converter working in continuous conduction mode(CCM) are studied in this paper. First of all, the two-dimensional discrete mapping model is established. Next, reference current at the period-doubling point and the border of inductor current are derived. Then, the bifurcation diagrams are drawn with the aid of MATLAB. Meanwhile, circuit simulations are executed with PSIM, and time domain waveforms as well as phase portraits in i_L–v_C plane are plotted with MATLAB on the basis of simulation data. After that, we construct the Jacobian matrix and analyze the stability of the system based on the roots of characteristic equations. Finally, the validity of theoretical analysis has been verified by circuit testing. The simulation and experimental results show that,with the increase of reference current I_(ref), the corresponding switching frequency f is approaching to low-frequency stage continuously when the period-doubling bifurcation happens, leading to the converter tending to be unstable. With the increase of f, the corresponding Irefdecreases when the period-doubling bifurcation occurs, indicating the stable working range of the system becomes smaller. 展开更多
关键词 peak current mode Buck converter high frequency bifurcation chaos
下载PDF
Model Predictive Control Circuit of the Current Source Matrix Converter
4
作者 Grzegorz Tadra Zbigniew Fedyczak Pawel Szczesniak 《Journal of Power and Energy Engineering》 2015年第4期136-145,共10页
In this paper, a new predictive control strategy for current source matrix converter (CSMC) is presented. Proposed predictive control strategy allows for creating output voltages with boost type voltage transfer ratio... In this paper, a new predictive control strategy for current source matrix converter (CSMC) is presented. Proposed predictive control strategy allows for creating output voltages with boost type voltage transfer ratio and desired frequency. The description of predictive control circuit of the CSMC is presented. Furthermore the simulation test results to confirm functionality of the proposed control strategy and converter properties under this strategy are shown. 展开更多
关键词 AC/AC frequency converters Current Source Matrix converter Predictive Control Strategy
下载PDF
MICROPROCESSOR BASED MODEL FOLLOWING ADAPTIVE CONTROL SYSTEM FOR CSIM DRIVES
5
作者 张春明 左敦稳 王珉 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 1996年第2期40+35-39,共6页
A model following adaptive control system for CSIM is presented in this paper. A dynamic mathematical model of slip control based system is obtained. With the help of model reducing technique, full order model is ... A model following adaptive control system for CSIM is presented in this paper. A dynamic mathematical model of slip control based system is obtained. With the help of model reducing technique, full order model is reduced to simplify the design without degrading much of the performance. Model following adaptive control laws in discrete form are derived. These laws satisfy the hyperstability condition for taking care of the load and machine parameter changes of the drive. A microprocessor 8098 is used to develop the speed controller. The implementation of the control system uses only available variables of the reference model and the controlled plant. Experimental results are given to demonstrate the good performance of the system. 展开更多
关键词 induction motors frequency converters microprocessors adaptive control model following
下载PDF
Evaluation of thermal imaging system and thermal radiation detector for real-time condition monitoring of high power frequency converters 被引量:1
6
作者 Anders Eriksen D. Osinski D. R. Hjelme 《Advances in Manufacturing》 SCIE CAS 2014年第1期88-94,共7页
We have carried out at laboratory test to study the feasibility of using thermal radiation detectors for online thermal monitoring of electrical systems in wind turbines. A 25 kW frequency converter is instrumented wi... We have carried out at laboratory test to study the feasibility of using thermal radiation detectors for online thermal monitoring of electrical systems in wind turbines. A 25 kW frequency converter is instrumented with a thermal camera, operating in the 8-14 μm wave- length range, and a single-pixel thermopile sensor, operating in the 4-8 μm wavelength range, to monitor the temperature development of the power electronics under various load sequences. Both systems performed satisfactorily with insignificant temperature deviations when compared to data from calibrated point contact sensor. With spatial averaging over a 7 mm × 7 mm for the camera and temporal averaging over 60 s for the thermo- pile sensor, we reduce the root mean square noise to 45 mK and 68 mK respectively. The low cost and simple operation of the thermopile sensor make it very attractive for condition monitoring applications, whereas the attractive feature of the camera is the possibility of multi-point or distributed temperature measurements. 展开更多
关键词 Temperature measurement Conditionmonitoring frequency converter Wind turbine
原文传递
Development of capacitive sensor signal conditioning system for angular displacement measurement using timer IC LM555 and UFDC 被引量:2
7
作者 Sumitesh Majumder T K Maiti 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第1期49-54,共6页
In this research paper,we have presented variable area type capacitive sensor signal conditioning system for angular displacement measurement and for this purpose we have used timer LM555 based astable multivibrator a... In this research paper,we have presented variable area type capacitive sensor signal conditioning system for angular displacement measurement and for this purpose we have used timer LM555 based astable multivibrator and universal frequency to digital converter (UFDC). Due to variation in angular displacement in the variable area type capacitor which is connected in the timer based astable circuit,capacitance changes which in turn changes the time period of the timer circuit output. The time period of the timer output waveform is linear with the capacitance and hence linear with angular displacement. The timer output is further processed with UFDC for the measurement. The experimental results show that the time period is linear with the angular displacement in the range of 0- 180° and the uncertainty we should associate it with this average time period value is the standard deviation of the mean,often called the standard error (SE),which is ± 0.023 μs. Because of the simplicity,this measurement system can be used in both electronic and industrial instrumentation. 展开更多
关键词 variable area type capacitive sensor timer circuit sensor interfacing astable multivibrator universal frequency to digital converter (UFDC)
下载PDF
西门子SOMATOM Perspective CT故障维修三例 被引量:1
8
作者 何铁 杨利鹏 《医疗装备》 2021年第21期139-140,共2页
西门子SOMATOM Perspective CT是一台64排128层螺旋CT,具有扫描速度快、成像清晰度高、辐射剂量小、后处理功能强的特点,除可进行常规CT检查、普通增强CT检查外,还可对全身大血管、脑血管、心脏血管进行检查,现介绍其在使用过程中出现... 西门子SOMATOM Perspective CT是一台64排128层螺旋CT,具有扫描速度快、成像清晰度高、辐射剂量小、后处理功能强的特点,除可进行常规CT检查、普通增强CT检查外,还可对全身大血管、脑血管、心脏血管进行检查,现介绍其在使用过程中出现的三例故障,将故障分析和处理归纳总结,仅供同行参考。 展开更多
关键词 温度传感器 PACS 数据库 frequency converter STANDBY
下载PDF
产生高功率UV光硼酸盐晶体的可靠性改进
9
作者 Y.K.Yap, M.Yoshimura, Y.Mori, T.Sasaki (Department of Electrical Engineering,Osaka University,2 1 Yamadaoka,Suita,Osaka 565 0871,Japan) (TEL +81 6 6879 7707,FAX +81 6 6879 7708) 《人工晶体学报》 EI CAS CSCD 北大核心 2000年第S1期11-11,共1页
All solid state UV lasers have been in demand for various industrial and medical applications because of the convenient operation procedure and cost effectiveness as alternative to corrosive gas based excimer laser.Th... All solid state UV lasers have been in demand for various industrial and medical applications because of the convenient operation procedure and cost effectiveness as alternative to corrosive gas based excimer laser.The performance of such lasers seems to depend on the capability and reliability of UV frequency converter.In the third decade,CsLiB 6O 10 (CLBO)and Gd xY 1 x Ca 4O(BO 3) 3 (GdYCOB)were developed by the authors group.CLBO is the most effective nonlinear optical crystal to generate high power fourth and fifth harmonics of Nd∶YAG laser.GdYCOB is the first material which can achieve noncritical phase matching (NCPM) condition for THG of Nd∶YAG laser.The NCPM condition is advantageous owing to its large angular acceptance and the elimination of walk off between fundamental and harmonic lights.On the other hand,reliability is very importmat for actual application of these crystals.Here,we will present about techniques to improve durability of NLO crystals for high power UV light generation.For instance,we found that removal of surface polishing compound by means of ion beam etching can imrpove surface durability of CLBO.Also,we will discussed about photo induced damages in GdYCOB and its solution. 展开更多
关键词 nonlinear optical crystal borate crystal UV frequency converter
下载PDF
Research and improvement of leakage protection system in traction motor
10
作者 陈霞 席新博 +3 位作者 褚鹏 裴咏春 尹俊华 王德兰 《Journal of Measurement Science and Instrumentation》 CAS 2012年第3期294-297,共4页
Because the leakage protection circuit in traction motor of coal mining machine is impacted by frequency converter devices,malfunctions appear frequently.This paper makes an in-depth analysis,proposes a solution of us... Because the leakage protection circuit in traction motor of coal mining machine is impacted by frequency converter devices,malfunctions appear frequently.This paper makes an in-depth analysis,proposes a solution of using the subtraction circuit to offset interference signals and conducts a simulation analysis.The above scheme,which is simple and easily realized,can improve the reliability of leakage protection device in traction motor. 展开更多
关键词 coal mining machine traction motor leakage protection frequency converter
下载PDF
Strategies of "Power-off Reset" Failure for Siemens MM440 in the Application of Gas Press
11
作者 MIN Haibin ZHANG Hao JIN Yikun 《International Journal of Plant Engineering and Management》 2018年第3期179-185,共7页
Gas pressurized fan speed control and remote monitoring was achieved based on three sets of gas pressure MM440 frequency converter control system, through the Profibus-DP network transmission of exchange data and sign... Gas pressurized fan speed control and remote monitoring was achieved based on three sets of gas pressure MM440 frequency converter control system, through the Profibus-DP network transmission of exchange data and signal instructions. In operation, one converter which adopted " power-off reset" has broken down, so as to cause two other gas pressurized frequency converter tripping. This paper proposed method to achieve capture and process failures, and application to converter control system. The result shows that the present method solves the fault, improves the system operation stability and meets the requirement of production. 展开更多
关键词 gas press frequency converter electronic control network composition
下载PDF
Analysis and Prototyping of Multicellular DC-DC Transformer for Environmentally Friendly Data Centers
12
作者 Yusuke Hayashi Tamotsu Ninomiya 《Journal of Energy and Power Engineering》 2016年第5期313-323,共11页
A multicellular DCX (dc-dc transformer) using unregulated cell converters has been proposed for the environmentally friendly data centers. The high speed cell converter with the switching frequency over MHz behaves ... A multicellular DCX (dc-dc transformer) using unregulated cell converters has been proposed for the environmentally friendly data centers. The high speed cell converter with the switching frequency over MHz behaves as an ideal transformer, and this behavior solves the voltage imbalance issue in the multicellular converter topology. The analysis of the unregulated cell converter is conducted by using the state space averaging method, and the operation condition for the ideal transformer is specified. The behavior of the multicellular DCX using the high speed cell converters has been also analyzed, and the voltage imbalance issue among cell converters is discussed quantitatively. A prototype of a 19.2 kW 384 V-384 V multicellular DCX using sixty-four unregulated cell converters is fabricated and the validity of the analyses is verified. 展开更多
关键词 DCX (dc-dc transformer) high frequency dc-dc converter ISOP (input series output parallel) IPOS (input parallel output series) state space averaging method.
下载PDF
Optimal Initialization and Starting Approach of Synchronous Condenser Integrated Power Grid
13
作者 Puyu Wang Xing Liu +6 位作者 Qingwen Mou Tao Yuan Tianming Gu Hemin Yang Xiao-Ping Zhang Zhengrong Xiang Chunyi Guo 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第1期248-260,共13页
Synchronous condensers(SCs)are generally used at the receiving-end stations of ultra-high-voltage direct current(UHVDC)transmission systems due to their strong reactive power support and flexible regulation of reactiv... Synchronous condensers(SCs)are generally used at the receiving-end stations of ultra-high-voltage direct current(UHVDC)transmission systems due to their strong reactive power support and flexible regulation of reactive power according to the interconnected grids operating conditions.In this paper,different starting control schemes of a SC integrated power grid are investigated providing four main contributions:1)The principle of reactive power support of the SC on the interconnected power grid is analytically studied,providing the establishment of mathematical models.2)Four different starting control schemes are developed for the initialization and SC integration,i.e.in Scheme 1,a preset initial falling speed is directly utilized without initialization;in Scheme 2,a black start sequential control approach with a static frequency converter(SFC)is proposed;in Scheme 3,PI/PD/PID controllers are respectively applied for the excitation device at the speed-falling stage;in Scheme 4,a pre-insertion approach of an energy absorption component with R/L/RL is utilized to suppress the surges at the SC integration instant.3)The dynamic behaviors of four different starting schemes at specific operating stages are evaluated.4)The success rate of SC integration is analyzed to evaluate starting control performance.Performance of the SC interconnected system with four different starting control schemes is evaluated in the timedomain simulation environment PSCAD/EMTDC^(TM).The results prove the superiority of the proposed starting control approach in Scheme 4. 展开更多
关键词 Black start dynamic behaviors excitation system pre-insertion of energy absorption components starting control schemes static frequency converter(SFC) success rate of integration synchronous condenser(SC)
原文传递
Dual-output modulation in time-wavelength interleaved photonic analog-to-digital converter based on actively mode-locked laser 被引量:3
14
作者 张华杰 邹卫文 +1 位作者 杨光 陈建平 《Chinese Optics Letters》 SCIE EI CAS CSCD 2016年第3期18-22,共5页
This Letter demonstrates the application of dual-output modulation in a photonic analog-to-digital converter (PADC) with a high sampling rate and resolution. The PADC is time-wavelength interleaved and based on an a... This Letter demonstrates the application of dual-output modulation in a photonic analog-to-digital converter (PADC) with a high sampling rate and resolution. The PADC is time-wavelength interleaved and based on an actively mode-locked laser. According to theoretical analysis, the dual-output PADC system shows a better linearity for achieving a higher dynamic range. In the experiment, third-order distortion is significantly sup- pressed by -40 dB when the dual-output modulator is used and the effective number of bits of the PADC has reached 9.0 bits below 0.2 GHz and 6.4 bits at 6.1 GHz in our PADC with a sampling rate of 20 GS/s. 展开更多
关键词 frequency converters Lasers Locks (fasteners) Mode locked fiber lasers MODULATION
原文传递
A 10 MHz ripple-based on-time controlled buck converter with dual ripple compensation
15
作者 吕旦竹 虞佳乐 洪志良 《Journal of Semiconductors》 EI CAS CSCD 2013年第2期86-92,共7页
A 10 MHz ripple-based on-time controlled buck converter is presented. A novel low-cost dual ripple compensation, which consists of coupling capacitor compensation and passive equivalent series resistance compensation,... A 10 MHz ripple-based on-time controlled buck converter is presented. A novel low-cost dual ripple compensation, which consists of coupling capacitor compensation and passive equivalent series resistance compensation, is proposed to achieve a fast load transient response and robust stability simultaneously. Implemented in a 2P4M 0.35 um CMOS process, the converter achieves fix-frequency output with a ripple of below 10 mV and an overshoot of 10 mV at 400 mA step load transient response. With width optimization of the power transistors in an ultra-heavy load and PFM control in a light load, the efficiency stays at over 83% for a load range from 20 mA to 1.5 A and the peak efficiency reaches 90.16%. 展开更多
关键词 ripple-based on-time control dual ripple compensation high switching frequency buck converter
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部