The ammonium salt corrosion is a typical failure mode for the hydrogenation reaction effluent air cooler(REAC) system. In order to investigate the corrosion characteristics in the REAC system, numerical simulations we...The ammonium salt corrosion is a typical failure mode for the hydrogenation reaction effluent air cooler(REAC) system. In order to investigate the corrosion characteristics in the REAC system, numerical simulations were performed by using the mixture model, the heating transfer model, and the particles tracking model. The results show that the differences between the temperature and the velocity at each cross section of the first-row and second-row tubes are small. The inertia of the particles plays an important role in the particle’s deposition, and the smaller particles distribute more uniformly in the air cooler. However, for larger particles, they prefer falling from the inner side of the vertical elbow, and preferentially depositing at the inlet header and pipes before saturation. In the heat exchanger tubes, the particle deposition number is larger in the second-row tubes than that in the first-row tubes, and the high-risk tubes mainly concentrate on the middle and right side of the air cooler. The kinetic parameters of the particles are in accordance with the blocking-prone position in many real operating conditions.展开更多
The air cooler is an important equipment in the petroleum refining industry.Ammonium chloride(NH4 Cl)deposition-induced corrosion is one of its main failure forms.In this study,the ammonium salt crystallization temper...The air cooler is an important equipment in the petroleum refining industry.Ammonium chloride(NH4 Cl)deposition-induced corrosion is one of its main failure forms.In this study,the ammonium salt crystallization temperature is chosen as the key decision variable of NH4 Cl deposition-induced corrosion through in-depth mechanism research and experimental analysis.The functional link neural network(FLNN)is adopted as the basic algorithm for modeling because of its advantages in dealing with non-linear problems and its fast-computational ability.A hybrid FLNN attached to a small norm is built to improve the generalization performance of the model.Then,the trained model is used to predict the NH4 Cl salt crystallization temperature in the air cooler of a sour water stripper plant.Experimental results show the proposed improved FLNN algorithm can achieve better generalization performance than the PLS,the back propagation neural network,and the conventional FLNN models.展开更多
Radiant syngas cooler(RSC)is widely used as a waste heat recovery equipment in industrial gasification.In this work,an RSC with radiation screens is established and the impact of gaseous radiative property models,gas ...Radiant syngas cooler(RSC)is widely used as a waste heat recovery equipment in industrial gasification.In this work,an RSC with radiation screens is established and the impact of gaseous radiative property models,gas components,and ash particles on heat transfer is investigated by the numerical simulation method.Considering the syngas components and the pressure environment of the RSC,a modified weighted-sum-of-gray-gases model was developed.The modified model shows high accuracy in validation.In computational fluid dynamics simulation,the calculated steam production is only 0.63%in error with the industrial data.Compared with Smith's model,the temperature decay along the axial direction calculated by the modified model is faster.Syngas components are of great significance to heat recovery capacity,especially when the absorbing gas fraction is less than 10%.After considering the influence of particles,the outlet temperature and the proportion of radiative heat transfer are less affected,but the difference in steam output reaches 2.7 t·h^(-1).The particle deposition on the wall greatly reduces the heat recovery performance of an RSC.展开更多
Corrosion leakages often occur in the air cooler of a hydrocracking unit,with the failure sites mainly located in the entrance area of the tubes.An analysis of the macroscopic morphology and corrosion products confirm...Corrosion leakages often occur in the air cooler of a hydrocracking unit,with the failure sites mainly located in the entrance area of the tubes.An analysis of the macroscopic morphology and corrosion products confirmed that the damage was caused by erosion-corrosion(E-C).Numerical and experimental methods were applied to investigate the E-C mechanism in the air cooler.Computational fluid dynamics(CFD)was used to calculate the hydrodynamic parameters of the air cooler.The results showed that there was a biased flow in the air cooler,which led to a significant increase in velocity,turbulent kinetic energy and wall shear within 0.2 m of the tube entrance.A visualization experiment was then performed to determine the principles of migration and transformation of multiphase flow in the air cooler tubes.Various flow patterns(pure droplet flow,mist flow,and annular flow)and their evolutionary processes were clearly depicted experimentally.The initiation mechanism and processes leading to the development of E-C in the air cooler were also determined.This study provided a comprehensive explanation for the E-C failures that occur in air coolers during operation.展开更多
Highly accurate manufacture in machining industry can only be obtained with precise temperature control of the coolant (oil or water).Machine tool with more accurate,stable and advanced the precision of the working ...Highly accurate manufacture in machining industry can only be obtained with precise temperature control of the coolant (oil or water).Machine tool with more accurate,stable and advanced the precision of the working component cannot be developed without appropriate cooling.However,the machine tool coolers are facing the control hunting of cooling temperature and the dramatic variation of heat load in high-accuracy machining.The main objective of this study is to evaluate the influence of the hot-gas by-pass scheme and suction regulation for capacity control of a machine tool cooler system.In this study,experimental investigation on both hot-gas by-pass scheme and suction valve regulation for capacity control has been proposed.Effects of using capillary tube and thermostatic expansion valve along with different capacity control scheme have been investigated extensively in an environmental testing room.Cooling performance and power consumption of the cooler system have been measured and analyzed as well by comparing with different opening percentage of throttling valve under specific coolant temperature.The experimental results reveal that the power consumption will reduce slightly by capacity control using the hot-gas by-pass scheme but the coefficient of performance (COP) of the overall system will decrease.Lower coolant temperature will result in higher compressor power consumption as well.While conducting suction valve regulating for capacity control,energy-saving at 10%-12% can be obtained by using thermostatic expansion valve under different evaporator load.It also reveals that suction valve regulation along with adequate choice of thermostatic expansion valve can provide alternative choice for steady capacity control and substantial energy-saving.The proposed cooler systems with different capacity control schemes are not only more cost-effective than inverter driven system,but also can perform energy-saving and precise temperature control specific for high-accuracy machine tool cooling.展开更多
The so-called indirect evaporative cooling technology is widely used in air conditioning applications.The thermal characterization of tube-type indirect evaporative coolers,however,still presents challenges which need...The so-called indirect evaporative cooling technology is widely used in air conditioning applications.The thermal characterization of tube-type indirect evaporative coolers,however,still presents challenges which need to be addressed to make this technology more reliable and easy to implement.This experimental study deals with the performances of a tube-type indirect evaporative cooler based on an aluminum tube with a 10 mm diameter.In particular,the required tests were carried out considering a range of dry-bulb temperatures between 16℃ and 18℃ and a temperature difference between the wet-bulb and dry-bulb temperature of 2℃∼4℃.The integrated convective heat transfer coefficient inside the tube in the drenching condition has been found to lie in the range between 36.10 and 437.4(W/(m^(2)⋅K)).展开更多
To improve the wall surface hydrophilicity of a tube type indirect evaporative cooler,a new method adopting porous ceramics is proposed.This method realizes the combination of porous ceramics and the evaporative cooli...To improve the wall surface hydrophilicity of a tube type indirect evaporative cooler,a new method adopting porous ceramics is proposed.This method realizes the combination of porous ceramics and the evaporative cooling technique.The design calculation of the porous ceramics tube type dew point indirect evaporative cooler are carried out from such aspects as the volumes and status parameters of the primary and secondary air,the cooler structure,the heat transfer of the solid porous ceramic tubes and the resistance of the cooler.The calculation results show that the design is reasonable.Finally,based on the design calculation,the porous ceramics tube type dew point indirect evaporative cooler is successfully manufactured.展开更多
Based on the fluid network theory,the possibility of utilizing regenerator flow resistance to suppress the direct current (DC) flow induced by the introduction of a double-inlet in a pulse tube cooler is investigate...Based on the fluid network theory,the possibility of utilizing regenerator flow resistance to suppress the direct current (DC) flow induced by the introduction of a double-inlet in a pulse tube cooler is investigated theoretically. The calculation results show that increasing regenerator flow resistance can lead to a smaller extent of DC flow.Therefore,a better stability performance of the cooler can be realized.On this basis,the stability characteristics of the cooler with various regenerator matrix arrangements are studied by experiments.By replacing 30% space of 247 screens of stainless steel mesh at the cold part of the regenerator by lead balls of 0.25 mm diameter,a long-time stable temperature output at 80 K region is achieved. This achievement provides a new way to obtain stable performance for pulse tube coolers at high temperature and is helpful for its application.展开更多
Oxy-combustion is a promising carbon-capture technology,but atmospheric-pressure oxy-combustion has a relatively low net efficiency,limiting its application in power plants.In pressurized oxycombustion(POC),the boiler...Oxy-combustion is a promising carbon-capture technology,but atmospheric-pressure oxy-combustion has a relatively low net efficiency,limiting its application in power plants.In pressurized oxycombustion(POC),the boiler,air separation unit,flue gas recirculation unit,and CO_(2)purification and compression unit are all operated at elevated pressure;this makes the process more efficient,with many advantages over atmospheric pressure,such as low NO_(x)emissions,a smaller boiler size,and more.POC is also more promising for industrial application and has attracted widespread research interest in recent years.It can produce high-pressure CO_(2)with a purity of approximately 95%,which can be used directly for enhanced oil recovery or geo-sequestration.However,the pollutant emissions must meet the standards for carbon capture,storage,and utilization.Because of the high oxygen and moisture concentrations in POC,the formation of acids via the oxidation and solution of SO_(x)and NO_(x)can be increased,causing the corrosion of pipelines and equipment.Furthermore,particulate matter(PM)and mercury emissions can harm the environment and human health.The main distinction between pressurized and atmospheric-pressure oxy-combustion is the former’s elevated pressure;thus,the effect of this pressure on the pollutants emitted from POC—including SO_(x),NO_(x),PM,and mercury—must be understood,and effective control methodologies must be incorporated to control the formation of these pollutants.This paper reviews recent advances in research on SO_(x),NO_(x),PM,and mercury formation and control in POC systems that can aid in pollutant control in such systems.展开更多
When sinters are filled into the sinter cooler from the sintering machine, it is commonly seen that, due to segregation effects, sinters of larger size usually accumulate closer to the inner wall of the sinter cooler,...When sinters are filled into the sinter cooler from the sintering machine, it is commonly seen that, due to segregation effects, sinters of larger size usually accumulate closer to the inner wall of the sinter cooler, whereas those of smaller size are to the outer wall. This nonuniform distribution of sinters has led to uneven cooling effect throughout the cooler. This causes the sinters leaving the cooler at a large temperature difference. This undesired temperature difference leads to the deformation and even the destruction of the conveyors. The computational fluid dynamics (CFD) technique was used in the present work to investigate the heat and fluid flow phenomena within the sinter cooler corresponding to the different distribution of sinter layer porosity, which was highly dependent on the arrangement and orientation of sinters within the sinter cooler. It is confirmed that a high mass flow rate within the sinter layer causes a low temperature region and vice versa. The flow fields for vertically reducing porosity distribution and random distribution are almost identical indicating the relative insignificance of convective heat transfer mechanism.展开更多
5G网络建设和大规模数据中心建设带来了大量光模块需求。在光模块生产制造中,为了保障光模块在环境温度变化情况下能够长时间正常工作,需要检测模块在不同温度下的性能,而进行高低温测试。高低温测试在光模块制造成本中占了很大比重。...5G网络建设和大规模数据中心建设带来了大量光模块需求。在光模块生产制造中,为了保障光模块在环境温度变化情况下能够长时间正常工作,需要检测模块在不同温度下的性能,而进行高低温测试。高低温测试在光模块制造成本中占了很大比重。设计了一种基于半导体制冷器(Thermo Electric Cooler)的光模块高低温测试系统,相较传统基于热流仪的方案,不需要压缩空气,能够大幅降低功耗、噪声和整体成本,且能够实现与热流仪相当的升降温时间。该系统对于节能减排、降低光模块制造成本有重要意义。展开更多
基金supported by the National Key R&D Program of China(Grant No.2017YFF0210403)the Zhejiang Provincial Natural Science Foundation of China(Grant No.LY17E060008)the Talent Project of Zhejiang Association for Science and Development Project of SINOPEC(No.318023-2)
文摘The ammonium salt corrosion is a typical failure mode for the hydrogenation reaction effluent air cooler(REAC) system. In order to investigate the corrosion characteristics in the REAC system, numerical simulations were performed by using the mixture model, the heating transfer model, and the particles tracking model. The results show that the differences between the temperature and the velocity at each cross section of the first-row and second-row tubes are small. The inertia of the particles plays an important role in the particle’s deposition, and the smaller particles distribute more uniformly in the air cooler. However, for larger particles, they prefer falling from the inner side of the vertical elbow, and preferentially depositing at the inlet header and pipes before saturation. In the heat exchanger tubes, the particle deposition number is larger in the second-row tubes than that in the first-row tubes, and the high-risk tubes mainly concentrate on the middle and right side of the air cooler. The kinetic parameters of the particles are in accordance with the blocking-prone position in many real operating conditions.
基金supported by the National Natural Science Foundation of China(Grant No.51876194,U1909216)the China Petrochemical Corporation Research Project(318023-2)the Zhejiang Public Welfare Technology Research Project(LGG20F030007)。
文摘The air cooler is an important equipment in the petroleum refining industry.Ammonium chloride(NH4 Cl)deposition-induced corrosion is one of its main failure forms.In this study,the ammonium salt crystallization temperature is chosen as the key decision variable of NH4 Cl deposition-induced corrosion through in-depth mechanism research and experimental analysis.The functional link neural network(FLNN)is adopted as the basic algorithm for modeling because of its advantages in dealing with non-linear problems and its fast-computational ability.A hybrid FLNN attached to a small norm is built to improve the generalization performance of the model.Then,the trained model is used to predict the NH4 Cl salt crystallization temperature in the air cooler of a sour water stripper plant.Experimental results show the proposed improved FLNN algorithm can achieve better generalization performance than the PLS,the back propagation neural network,and the conventional FLNN models.
基金supported by the National Natural Science Foundation of China(21878082).
文摘Radiant syngas cooler(RSC)is widely used as a waste heat recovery equipment in industrial gasification.In this work,an RSC with radiation screens is established and the impact of gaseous radiative property models,gas components,and ash particles on heat transfer is investigated by the numerical simulation method.Considering the syngas components and the pressure environment of the RSC,a modified weighted-sum-of-gray-gases model was developed.The modified model shows high accuracy in validation.In computational fluid dynamics simulation,the calculated steam production is only 0.63%in error with the industrial data.Compared with Smith's model,the temperature decay along the axial direction calculated by the modified model is faster.Syngas components are of great significance to heat recovery capacity,especially when the absorbing gas fraction is less than 10%.After considering the influence of particles,the outlet temperature and the proportion of radiative heat transfer are less affected,but the difference in steam output reaches 2.7 t·h^(-1).The particle deposition on the wall greatly reduces the heat recovery performance of an RSC.
基金supported by the National Key R&D Program of China(2021YFB3301100)Beijing University of Chemical Technology Interdisciplinary Program(XK2023-07).
文摘Corrosion leakages often occur in the air cooler of a hydrocracking unit,with the failure sites mainly located in the entrance area of the tubes.An analysis of the macroscopic morphology and corrosion products confirmed that the damage was caused by erosion-corrosion(E-C).Numerical and experimental methods were applied to investigate the E-C mechanism in the air cooler.Computational fluid dynamics(CFD)was used to calculate the hydrodynamic parameters of the air cooler.The results showed that there was a biased flow in the air cooler,which led to a significant increase in velocity,turbulent kinetic energy and wall shear within 0.2 m of the tube entrance.A visualization experiment was then performed to determine the principles of migration and transformation of multiphase flow in the air cooler tubes.Various flow patterns(pure droplet flow,mist flow,and annular flow)and their evolutionary processes were clearly depicted experimentally.The initiation mechanism and processes leading to the development of E-C in the air cooler were also determined.This study provided a comprehensive explanation for the E-C failures that occur in air coolers during operation.
基金supported by Science Committee of Taiwan,China(Grant No. NSC 98-2622-E-167-029-CC3),and Industrial Technology Research Institute,Taiwan,China
文摘Highly accurate manufacture in machining industry can only be obtained with precise temperature control of the coolant (oil or water).Machine tool with more accurate,stable and advanced the precision of the working component cannot be developed without appropriate cooling.However,the machine tool coolers are facing the control hunting of cooling temperature and the dramatic variation of heat load in high-accuracy machining.The main objective of this study is to evaluate the influence of the hot-gas by-pass scheme and suction regulation for capacity control of a machine tool cooler system.In this study,experimental investigation on both hot-gas by-pass scheme and suction valve regulation for capacity control has been proposed.Effects of using capillary tube and thermostatic expansion valve along with different capacity control scheme have been investigated extensively in an environmental testing room.Cooling performance and power consumption of the cooler system have been measured and analyzed as well by comparing with different opening percentage of throttling valve under specific coolant temperature.The experimental results reveal that the power consumption will reduce slightly by capacity control using the hot-gas by-pass scheme but the coefficient of performance (COP) of the overall system will decrease.Lower coolant temperature will result in higher compressor power consumption as well.While conducting suction valve regulating for capacity control,energy-saving at 10%-12% can be obtained by using thermostatic expansion valve under different evaporator load.It also reveals that suction valve regulation along with adequate choice of thermostatic expansion valve can provide alternative choice for steady capacity control and substantial energy-saving.The proposed cooler systems with different capacity control schemes are not only more cost-effective than inverter driven system,but also can perform energy-saving and precise temperature control specific for high-accuracy machine tool cooling.
基金This work was supported by Natural Science Basic Research Program of Shaanxi(2021JQ-689).
文摘The so-called indirect evaporative cooling technology is widely used in air conditioning applications.The thermal characterization of tube-type indirect evaporative coolers,however,still presents challenges which need to be addressed to make this technology more reliable and easy to implement.This experimental study deals with the performances of a tube-type indirect evaporative cooler based on an aluminum tube with a 10 mm diameter.In particular,the required tests were carried out considering a range of dry-bulb temperatures between 16℃ and 18℃ and a temperature difference between the wet-bulb and dry-bulb temperature of 2℃∼4℃.The integrated convective heat transfer coefficient inside the tube in the drenching condition has been found to lie in the range between 36.10 and 437.4(W/(m^(2)⋅K)).
基金The National Natural Science Foundation of China(No.50846056)
文摘To improve the wall surface hydrophilicity of a tube type indirect evaporative cooler,a new method adopting porous ceramics is proposed.This method realizes the combination of porous ceramics and the evaporative cooling technique.The design calculation of the porous ceramics tube type dew point indirect evaporative cooler are carried out from such aspects as the volumes and status parameters of the primary and secondary air,the cooler structure,the heat transfer of the solid porous ceramic tubes and the resistance of the cooler.The calculation results show that the design is reasonable.Finally,based on the design calculation,the porous ceramics tube type dew point indirect evaporative cooler is successfully manufactured.
基金The National Natural Science Foundation of China(No.50406009).
文摘Based on the fluid network theory,the possibility of utilizing regenerator flow resistance to suppress the direct current (DC) flow induced by the introduction of a double-inlet in a pulse tube cooler is investigated theoretically. The calculation results show that increasing regenerator flow resistance can lead to a smaller extent of DC flow.Therefore,a better stability performance of the cooler can be realized.On this basis,the stability characteristics of the cooler with various regenerator matrix arrangements are studied by experiments.By replacing 30% space of 247 screens of stainless steel mesh at the cold part of the regenerator by lead balls of 0.25 mm diameter,a long-time stable temperature output at 80 K region is achieved. This achievement provides a new way to obtain stable performance for pulse tube coolers at high temperature and is helpful for its application.
基金support of the National Key Research and Development Program of China(2022YFE0206600)the National Natural Science Foundation of China(52376125)Fundamental Research Funds for the Central Universities.
文摘Oxy-combustion is a promising carbon-capture technology,but atmospheric-pressure oxy-combustion has a relatively low net efficiency,limiting its application in power plants.In pressurized oxycombustion(POC),the boiler,air separation unit,flue gas recirculation unit,and CO_(2)purification and compression unit are all operated at elevated pressure;this makes the process more efficient,with many advantages over atmospheric pressure,such as low NO_(x)emissions,a smaller boiler size,and more.POC is also more promising for industrial application and has attracted widespread research interest in recent years.It can produce high-pressure CO_(2)with a purity of approximately 95%,which can be used directly for enhanced oil recovery or geo-sequestration.However,the pollutant emissions must meet the standards for carbon capture,storage,and utilization.Because of the high oxygen and moisture concentrations in POC,the formation of acids via the oxidation and solution of SO_(x)and NO_(x)can be increased,causing the corrosion of pipelines and equipment.Furthermore,particulate matter(PM)and mercury emissions can harm the environment and human health.The main distinction between pressurized and atmospheric-pressure oxy-combustion is the former’s elevated pressure;thus,the effect of this pressure on the pollutants emitted from POC—including SO_(x),NO_(x),PM,and mercury—must be understood,and effective control methodologies must be incorporated to control the formation of these pollutants.This paper reviews recent advances in research on SO_(x),NO_(x),PM,and mercury formation and control in POC systems that can aid in pollutant control in such systems.
文摘When sinters are filled into the sinter cooler from the sintering machine, it is commonly seen that, due to segregation effects, sinters of larger size usually accumulate closer to the inner wall of the sinter cooler, whereas those of smaller size are to the outer wall. This nonuniform distribution of sinters has led to uneven cooling effect throughout the cooler. This causes the sinters leaving the cooler at a large temperature difference. This undesired temperature difference leads to the deformation and even the destruction of the conveyors. The computational fluid dynamics (CFD) technique was used in the present work to investigate the heat and fluid flow phenomena within the sinter cooler corresponding to the different distribution of sinter layer porosity, which was highly dependent on the arrangement and orientation of sinters within the sinter cooler. It is confirmed that a high mass flow rate within the sinter layer causes a low temperature region and vice versa. The flow fields for vertically reducing porosity distribution and random distribution are almost identical indicating the relative insignificance of convective heat transfer mechanism.
文摘5G网络建设和大规模数据中心建设带来了大量光模块需求。在光模块生产制造中,为了保障光模块在环境温度变化情况下能够长时间正常工作,需要检测模块在不同温度下的性能,而进行高低温测试。高低温测试在光模块制造成本中占了很大比重。设计了一种基于半导体制冷器(Thermo Electric Cooler)的光模块高低温测试系统,相较传统基于热流仪的方案,不需要压缩空气,能够大幅降低功耗、噪声和整体成本,且能够实现与热流仪相当的升降温时间。该系统对于节能减排、降低光模块制造成本有重要意义。