Based on the heat and mass transfer theory and the characteristics of general-purpose software FLUENT, a three-dimensional numerical simulation platform, composed of lots of user defined functions(UDF), has been devel...Based on the heat and mass transfer theory and the characteristics of general-purpose software FLUENT, a three-dimensional numerical simulation platform, composed of lots of user defined functions(UDF), has been developed to simulate the thermal performance of natural draft wet cooling towers(NDWCTs). After validation, this platform is used to analyse thermal performances of a 220m high super large cooling tower designed for inland nuclear plant under different operational conditions. Variations of outlet temperature of the cooling tower caused by changes of water flow rates, inlet water temperatures are investigated. Effects of optimization through non-uniform water distributions on outlet water temperature are discussed, and the influences on the flow field inside the cooling tower are analyzed in detail. It is found that the outlet water temperature will increase as the water flow rate increases, but the air flow rate will decrease. The outlet water temperature will decrease 0.095K and 0.205K, respectively, if two non-uniform water distribution approaches are applied.展开更多
Combined with the parameters of the production process of a steel factory, numerical simulations for a new ladle from preheating to turnover are conducted using the finite element analysis system software (ANSYS). T...Combined with the parameters of the production process of a steel factory, numerical simulations for a new ladle from preheating to turnover are conducted using the finite element analysis system software (ANSYS). The measured data proved that the simulated results are reliable. The effects of preheating time, thermal cycling times, and empty package time on steel temperature are calculated, an ideal preheating time is provided, besides, based on the analysis of a single factor and use the nonlinear analysis method, a steel temperature compensating model with di- versified coupling factors is proposed, with the largest error of the present coupling model at 1. 462 ~C, and the er- rors between actual and target steel temperature in tundish after the model is applied to practical production are basi- cally controlled within -4-6 ~C, which can meet the accuracy of the manufacturer and has a practical guiding significance for the production in steelmaking workshops.展开更多
基金the National Natural Science Foundation of China (No. 51176170)Foundation for the Author of National Excellent Doctoral Dissertation of PR China (2007B4) are gratefully acknowledged
文摘Based on the heat and mass transfer theory and the characteristics of general-purpose software FLUENT, a three-dimensional numerical simulation platform, composed of lots of user defined functions(UDF), has been developed to simulate the thermal performance of natural draft wet cooling towers(NDWCTs). After validation, this platform is used to analyse thermal performances of a 220m high super large cooling tower designed for inland nuclear plant under different operational conditions. Variations of outlet temperature of the cooling tower caused by changes of water flow rates, inlet water temperatures are investigated. Effects of optimization through non-uniform water distributions on outlet water temperature are discussed, and the influences on the flow field inside the cooling tower are analyzed in detail. It is found that the outlet water temperature will increase as the water flow rate increases, but the air flow rate will decrease. The outlet water temperature will decrease 0.095K and 0.205K, respectively, if two non-uniform water distribution approaches are applied.
基金Item Sponsored by Technology Supporting Program During the 11th Five-Year Plan Period(BAE03A07)
文摘Combined with the parameters of the production process of a steel factory, numerical simulations for a new ladle from preheating to turnover are conducted using the finite element analysis system software (ANSYS). The measured data proved that the simulated results are reliable. The effects of preheating time, thermal cycling times, and empty package time on steel temperature are calculated, an ideal preheating time is provided, besides, based on the analysis of a single factor and use the nonlinear analysis method, a steel temperature compensating model with di- versified coupling factors is proposed, with the largest error of the present coupling model at 1. 462 ~C, and the er- rors between actual and target steel temperature in tundish after the model is applied to practical production are basi- cally controlled within -4-6 ~C, which can meet the accuracy of the manufacturer and has a practical guiding significance for the production in steelmaking workshops.