期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
A Novel Belief Rule-Based Fault Diagnosis Method with Interpretability 被引量:1
1
作者 Zhijie Zhou Zhichao Ming +4 位作者 Jie Wang Shuaiwen Tang You Cao Xiaoxia Han Gang Xiang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第8期1165-1185,共21页
Fault diagnosis plays an irreplaceable role in the normal operation of equipment.A fault diagnosis model is often required to be interpretable for increasing the trust between humans and the model.Due to the understan... Fault diagnosis plays an irreplaceable role in the normal operation of equipment.A fault diagnosis model is often required to be interpretable for increasing the trust between humans and the model.Due to the understandable knowledge expression and transparent reasoning process,the belief rule base(BRB)has extensive applications as an interpretable expert system in fault diagnosis.Optimization is an effective means to weaken the subjectivity of experts in BRB,where the interpretability of BRB may be weakened.Hence,to obtain a credible result,the weakening factors of interpretability in the BRB-based fault diagnosis model are firstly analyzed,which are manifested in deviation from the initial judgement of experts and over-optimization of parameters.For these two factors,three indexes are proposed,namely the consistency index of rules,consistency index of the rule base and over-optimization index,tomeasure the interpretability of the optimizedmodel.Considering both the accuracy and interpretability of amodel,an improved coordinate ascent(I-CA)algorithmis proposed to fine-tune the parameters of the fault diagnosis model based on BRB.In I-CA,the algorithm combined with the advance and retreat method and the golden section method is employed to be one-dimensional search algorithm.Furthermore,the random optimization sequence and adaptive step size are proposed to improve the accuracy of the model.Finally,a case study of fault diagnosis in aerospace relays based on BRB is carried out to verify the effectiveness of the proposed method. 展开更多
关键词 Fault diagnosis belief rule base INTERPRETABILITY weakening factors improved coordinate ascent
下载PDF
An Improved Inventory Coordination Model in a Multi-stage Multi-customer Supply Chain
2
作者 Hanwu Hu Chunlin Xing 《Chinese Business Review》 2006年第3期15-20,34,共7页
To solve the inventory coordination model in a multi-stage, multi-customer supply chain, this paper first analyzes the third model (integer powers of two multipliers at each firm) studied by Moutaz Khouja (2003), ... To solve the inventory coordination model in a multi-stage, multi-customer supply chain, this paper first analyzes the third model (integer powers of two multipliers at each firm) studied by Moutaz Khouja (2003), and the authors take a numerical example to prove that the third model is irrational to miss feasible solution. Then this paper puts up a new improved model (integer multiplier at each firm), and takes the example to prove it gives better results than the integer powers of two multipliers at each firm. 展开更多
关键词 inventory coordination model supply chain cycle time improve
下载PDF
Comparisons and Improvements of Key Operating Characteristics of Current Source Converter Applied in HVDC System
3
作者 Wenwen Zhang Longlong Chen +4 位作者 Xiaoguang Wei Guangfu Tang Lei Qi Chong Gao Zhiyuan He 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第5期1601-1612,共12页
Because of its controlled power factor and no commutation failure,current source converter(CSC)made up of reverse-blocking IGCTs(RB-IGCTs)offers broad application prospects in the field of HVDC system.Valve voltage an... Because of its controlled power factor and no commutation failure,current source converter(CSC)made up of reverse-blocking IGCTs(RB-IGCTs)offers broad application prospects in the field of HVDC system.Valve voltage and power operating range as the most important operating characteristics should be paid attention to but they are always contradictory.First,the relationship between valve voltage and modulation index is obtained.In particular,valve voltage of converter under the three typical modulation methods is compared,analyzed,and verified.Second,with the help of the independent control strategy and coordinated control strategy of both ends,power operating ranges of the three modulation methods are comprehensively analyzed and compared.Third,in order to solve power coupling at a low active power,the improved coordination control strategy at both ends in this paper is proposed and the relationships among active power,reactive power,DC current and phase angle difference are given in detail.Finally,a 500 kV/3 kA simulation system was built in PSCAD/EMTDC to obtain comparison results of the key operating characteristics of CSC under different modulation methods and the converter can realize unity power operation under random active power after adopting the improved coordinated control strategy,and DC current does not decrease to zero,verifying effectiveness of the coordinated control strategy. 展开更多
关键词 Current source converter improved coordinated control strategy reverse-blocking IGCT valve voltage
原文传递
上一页 1 下一页 到第