Hydrodynamics characterization in terms offlow regime behavior is a crucial task to enhance the design of bubble column reactors and scaling up related methodologies.This review presents recent studies on the typicalflo...Hydrodynamics characterization in terms offlow regime behavior is a crucial task to enhance the design of bubble column reactors and scaling up related methodologies.This review presents recent studies on the typicalflow regimes established in bubble columns.Some effort is also provided to introduce relevant definitions pertaining to thisfield,namely,that of“void fraction”and related(local,chordal,cross-sectional and volumetric)variants.Experimental studies involving different parameters that affect design and operating conditions are also discussed in detail.In the second part of the review,the attention is shifted to cases with internals of various types(perfo-rated plates,baffles,vibrating helical springs,mixers,and heat exchanger tubes)immersed in the bubble columns.It is shown that the presence of these elements has a limited influence on the global column hydrodynamics.However,they can make the homogeneousflow regime more stable in terms of transition gas velocity and transi-tion holdup value.The last section is used to highlight gaps which have not beenfilled yet and future directions of investigation.展开更多
Pitting corrosion is harmful during bridge construction,which will lead to uneven roughness of steel surfaces and reduce the thickness of steel.Hence,the effect of pitting corrosion on the mechanical properties of col...Pitting corrosion is harmful during bridge construction,which will lead to uneven roughness of steel surfaces and reduce the thickness of steel.Hence,the effect of pitting corrosion on the mechanical properties of cold-formed thin-walled steel stub columns is studied,and the empirical formulas are established through regression fitting to predict the ultimate load of web and flange under pitting corrosion.In detail,the failure modes and load-displacement curves of specimens with different locations,area ratios,and depths are obtained through a large number of non-linear finite element analysis.As for the specimens with pitting corrosion on the web,all the specimens are subject to local buckling failure,and the failure mode will not change with pitting corrosion,but the failure location will change with pitting corrosion location;the size,location,and area ratio of pitting corrosion have little influence on the ultimate load of cold-formed thin-walled steel short columns,but the loss rate of pitting corrosion section area has a greater impact on the ultimate bearing capacity.As for the specimen with flange pitting corrosion,the location and area ratio of pitting corrosion have less influence on the ultimate load of cold-formed thin-walled steel short columns,and the section area loss rate has greater influence on the ultimate bearing capacity;the impact of web pitting corrosion on the ultimate load is greater than that of flange pitting corrosion under the same condition of pitting corrosion section area.The prediction formulas of limit load which are suitable for pitting corrosion of web and flange are established,which can provide a reference for performance evaluation of corroded cold-formed thin-walled steel.展开更多
The constant bubble size modeling approach(CBSM)and variable bubble size modeling approach(VBSM)are frequently employed in Eulerian–Eulerian simulation of bubble columns.However,the accuracy of CBSM is limited while ...The constant bubble size modeling approach(CBSM)and variable bubble size modeling approach(VBSM)are frequently employed in Eulerian–Eulerian simulation of bubble columns.However,the accuracy of CBSM is limited while the computational efficiency of VBSM needs to be improved.This work aims to develop method for bubble size modeling which has high computational efficiency and accuracy in the simulation of bubble columns.The distribution of bubble sizes is represented by a series of discrete points,and the percentage of bubbles with various sizes at gas inlet is determined by the results of computational fluid dynamics(CFD)–population balance model(PBM)simulations,whereas the influence of bubble coalescence and breakup is neglected.The simulated results of a 0.15 m diameter bubble column suggest that the developed method has high computational speed and can achieve similar accuracy as CFD–PBM modeling.Furthermore,the convergence issues caused by solving population balance equations are addressed.展开更多
To enable rapid recovery of a steel bridge column after an earthquake,a novel tubular-section steel bridge column equipped with low-yield-point(LYP)steel tubular plates in the root replaceable pier is proposed.For the...To enable rapid recovery of a steel bridge column after an earthquake,a novel tubular-section steel bridge column equipped with low-yield-point(LYP)steel tubular plates in the root replaceable pier is proposed.For the purpose of discussing the seismic behavior of the novel steel bridge column,quasi-static tests and finite element simulation analyses of the specimens were carried out.The effects of parameters such as the axial compression ratio,eccentricity,and thickness and material strength of the tubular plate in the energy-dissipating zone are discussed.Experimental results from seven specimens that were subjected to four failure modes are presented.The damage to the quasi-static specimens is localized to the replaceable energy-dissipating pier.The seismic behavior of the novel steel bridge columns is significantly influenced by the axial compression ratio and eccentricity of specimens.Numerical results show that the high stress area of the specimens is mainly concentrated in the connection zone between the LYP steel tubular plate and the bottom steel plate,which is consistent with the position of the quasi-static specimen when it was prone to fracture.Finally,a calculation formula is proposed to facilitate the capacity prediction of this new steel tubular bridge column under repeated loading.展开更多
For dividing-wall distillation columns(DWDCs) separating a heavy-component dominated and wide boiling-point ternary(HCDWBT) mixture, a significant amount of excessive heat exists inevitably in stripping the heavy-comp...For dividing-wall distillation columns(DWDCs) separating a heavy-component dominated and wide boiling-point ternary(HCDWBT) mixture, a significant amount of excessive heat exists inevitably in stripping the heavy-component from the intermediate-component and it can be employed to initiate the development of vapor recompression heat pump(VRHP) assisted DWDC(VRHP-DWDC). Despite dividing wall may locate in the top, middle, and bottom, the optimum VRHP-DWDC is found to involve uniformlytwo VRHP circles. While the first one serves to compress and transform the excessive heat resulted from the separation of the heavy-component from the intermediate-component, the second one to compress and transform the overhead vapor stream of the light-component pre-heated sequentially with the condensate from the first one and the bottom product stream of the heavy-component, both releasing the temperature-elevated latent heat to the pre-fractionator's or common stripping section. The processing of two HCDWBT mixtures of benzene/toluene/o-xylene and n-pentane/n-hexane/n-heptane are selected to assess the derived optimum topological configurations of the VRHP-DWDC and their optimality is confirmed through detailed comparisons with the DWDC and two VRHP-DWDCs involving only one VRHP circle. The proposed strategy helps to tap the full potential of the VRHP-DWDC with considerably alleviated complication in process development.展开更多
Monte Carlo simulation of gamma photon transport and interaction with the distillation column and its contents was performed in order to predict the effects of gamma photons when they interact with matter. The results...Monte Carlo simulation of gamma photon transport and interaction with the distillation column and its contents was performed in order to predict the effects of gamma photons when they interact with matter. The results of the interaction and transport of gamma photons are presented as energy deposition on the distillation column and its contents. Energy attenuation was more pronounced on the column walls and trays as compared to the region between the trays, where there is mostly vapour space. Gamma column scanning was then used to verify the Monte Carlo simulation results by scanning and investigating the integrity of two laboratory prototype distillation and industrial distillation columns. One of the prototype distillation columns was 1 m tall with four trays and the other one was 1.8 m tall consisting of six trays and a packed bed. Commonly encountered distillation column malfunctions such as collapsed tray, weeping, flooding and foaming were simulated in the two prototype distillation columns and scanned. The industrial distillation column was a 26 m tall benzole prefractionator column, consisting of 60 single pass trays and a diameter of 0.8 m. A 10 mCi <sup>60</sup>Co gamma radiation source and NaI(Tl) scintillation detector were used to scan the distillation columns. The results from the two prototypes showed that all the simulated malfunctions were clearly detected except for foaming. The results from industrial distillation column showed that all the trays were in their correct position although tray number 32 could be partially damaged and just below tray 41, the scan revealed that there was a loss of column wall thickness. The obtained density profile for the industrial distillation column showed some small variations from the expected density profile and this was attributed to external features on the distillation column and wind bursts that shifted the source and detector from the chosen scan line orientation.展开更多
Eucalyptus nitens(E.nitens)has been much used for producing paper but also shows promise for structural applications.In this study,static compressive tests were undertaken to examine its suitability to be used in an i...Eucalyptus nitens(E.nitens)has been much used for producing paper but also shows promise for structural applications.In this study,static compressive tests were undertaken to examine its suitability to be used in an innovative composite column.The composite column was comprised of a rectangular steel tube with E.nitens timber infill.The nonlinear compressive behaviour of the composite column filled with E.nitens wood for both dry and wet conditions was examined.The same tests on rectangular steel tubes and bare dry and wet E.nitens samples were also undertaken as a comparison.For samples with different conditions,the ultimate capacity was evaluated and the effect of each condition on the compressive behaviour of the composite column was clarified.The steel tubes showed greater ductile behaviour,and more ductility was found in the wet samples.The steel tubes with E.nitens timber infill samples exhibited a greater linear elastic range connected with higher maximum loads,while the bare timber samples could support only lower maximum loads.The results from this research were promising for the use of rectangular steel tubes with E.nitens timber infill in structural applications.展开更多
The vapor recompression heat pump(VRHP) distillation technology offers significant improvements in energy efficiency for distillation systems with small temperature differences between the top and bottom of the column...The vapor recompression heat pump(VRHP) distillation technology offers significant improvements in energy efficiency for distillation systems with small temperature differences between the top and bottom of the column. However, the separation of wide-boiling binary mixtures leads to substantial temperature differences between the top and bottom of the column. This limits the applicability of conventional VRHP due to high capital costs and strict performance requirements of the compressor. To overcome these challenges and to accommodate compressor operating conditions, a novel synthesis and design method is introduced to integrate VRHPs with wide-boiling binary mixture distillation columns(WBMDCs). This method enables quick determination of an initial configuration for the integrated WBMDC-VRHP system and helps identify the optimum configuration with the minimum total annual cost. Two examples, namely the separation of benzene/toluene and isopropanol/chlorobenzene, are employed to derive optimum configurations of the WBMDC-VRHP and compare them with the WBMDC. A systematic comparison between the WBMDC-VRHP and WBMDC demonstrates the superior steady-state performance and economic efficiency of the WBMDC-VRHP.展开更多
During a sea firing training,the intelligent detection of projectile-induced water column targets in a firing video is the prerequisite for and critical to the automatic calculation of miss distance,while the correct ...During a sea firing training,the intelligent detection of projectile-induced water column targets in a firing video is the prerequisite for and critical to the automatic calculation of miss distance,while the correct and precise calculation of miss distance is directly affected by the accuracy,false alarm rate and time delay of detection.After analyzing the characteristics of projectile-induced water columns,an accurate detection algorithm for time backtracked projectile-induced water columns based on the improved you only look once(YOLO)network is put forward.The capability and accuracy of detecting projectileinduced water column targets with the conventional YOLO network are improved by optimizing the anchor box through K-means clustering and embedding the squeeze and excitation(SE)attention module.The detection area is limited by adopting a sea-sky line detection algorithm based on gray level co-occurrence matrix(GLCM),so as to effectively eliminate such disturbances as ocean waves and ship wakes,and lower the false alarm rate of projectile-induced water column detection.The improved algorithm increases the mAP50 of water column detection by 30.3%.On the basis of correct detection,a time backtracking algorithm is designed with mean shift to track images containing projectile-induced water column in reverse time sequence.It accurately detects a projectile-induced water column at the time of its initial appearance as well as its pixel position in images,and considerably reduces detection delay,so as to provide the support for the automatic,accurate,and real-time calculation of miss distance.展开更多
During the modernization or rehabilitation activity,the demolished structural waste causes large soil pollution and unavailability of natural aggregate is the big concern for the construction industry.Therefore,this m...During the modernization or rehabilitation activity,the demolished structural waste causes large soil pollution and unavailability of natural aggregate is the big concern for the construction industry.Therefore,this manuscript deals with the Composite Steel Circular Column(CSCC)with Recycled Aggregate concrete(RAC)as infill is partly used,with the replacement of 25%and 50%in M30 grade of Concrete.And internal reinforcement steel is fully replaced by rolled steel tubes(circular and square)with varied thickness,ISA-unequal angle.Around 14 specimens are cast and examined under axial load for analysis of the deflection characteristics,the load-bearing capacity along with its buckling behavior.The experimental values are estimated through LVDT(linear variable differential transducer)at 3-phase.The curve of load-deflection is drawn with the load pattern.From the date interpretation,it is found column made of 50%-RAC has more than 25%-RAC.展开更多
The addition of dispersed-phase nanoparticles in the liquid phase can enhance the gas-liquid transfer process as the suspended nanoparticles affect the transfer process inside the fluid through microdisturbance or mic...The addition of dispersed-phase nanoparticles in the liquid phase can enhance the gas-liquid transfer process as the suspended nanoparticles affect the transfer process inside the fluid through microdisturbance or micro-convection effects.In this article,a high-speed digital camera was used to visualize the bubble behavior of CO_(2) in pure water and nanofluids to examine the effects of CO_(2) gas flow rate,nanoparticle solid content and type on the bubble behavior in the fluids.The CO_(2) absorption performance in three water-based nanofluids were compared in a bubbler.And the mass transfer characteristics during CO_(2) bubble absorption and the reasons for the enhanced gas-liquid mass transfer effect of nanoparticles were analyzed.The results showed that the presence of nanoparticles affected the formation process of bubbles in the fluid,shortened the bubble detachment time,reduced the detachment diameter,effectively increased the gas-liquid contact area,and improved the bubbles detachment frequency.The system with MCM-41 corresponded to a higher overall mass transfer coefficient.Uncalined MCM-41 contained surfactant that enhanced foaming behavior in water.This prevented the transfer of CO_(2) to some extent,and the CO_(2) absorption by uncalined MCM-41/H_(2)O was 5.34%higher than that by pure water.Compared with SiO_(2) nanoparticles with the same particle size and the same composition,MCM-41 had a higher adsorption capacity and better hydrophilicity due to its larger specific surface area and rich porous structure,which was more favorable to accelerate the collision between nanoparticles and CO_(2) bubbles to cause micro-convection.Under the condition of 0.1%(mass)solid content,the enhancement of CO_(2) absorption process by MCM-41 nanoparticles was more significant and improved by 16.9%compared with pure water.展开更多
This manuscript presents a dataset detailing a method for purifying monomers. Purification plays a crucial role in every chemical process, as it leads to an improvement in product quality through the removal of impuri...This manuscript presents a dataset detailing a method for purifying monomers. Purification plays a crucial role in every chemical process, as it leads to an improvement in product quality through the removal of impurities. The primary method for monomer purification, like acrylonitrile (AN), is the distillation technique. However, this technique is unsafe and hard to set up or handle. A straightforward, risk-free, low-cost method like the column technique resolves these issues. A simple column technique demonstrated the successful execution of purifying AN. Fourier transform infrared (FTIR) and nuclear magnetic resonance (NMR) analyses confirmed that AN was successfully purified, with purity reaching 99.8%. FTIR spectra revealed changes in the position and intensity of the stretching vibration peaks after purification. Also, the functional groups of the inhibitor monomethyl ether of hydroquinone (MeHQ) were undetected after purification. Furthermore, after purification, NMR spectra revealed the absence of aromatic protons and carbons associated with MeHQ. In conclusion, the column technique is a successful and inexpensive way to purify AN monomers. This makes it useful for a wide range of applications, especially in polymerization reactions where MeHQ needs to be removed to prevent self-polymerization during the initiation process.展开更多
In recent years, precast segmental concrete bridge columns became prevalent because of the benefits of accelerated construction, low environmental impact, high quality and low life cycle costs. The lack of a detailed ...In recent years, precast segmental concrete bridge columns became prevalent because of the benefits of accelerated construction, low environmental impact, high quality and low life cycle costs. The lack of a detailed configuration and appropriate design procedure to ensure a comparable performance with monolithic construction has impeded this structural system from being widely used in areas of high seismicity. In this study, precast segmental bridge column cyclic loading tests were conducted to investigate the performance of unbonded post-tensioned segmental bridge columns. One monolithic and two precast segmental columns were tested. The preeast segmental column exhibited minor damage and small residual displacement after the maximum 7% cyclic drift; energy dissipation (ED) can be enhanced byadding ED bars. The experimental results were modeled by a simplified pushover method (SPOM), as well as a fiber model (FIBM) finite element method. Forty-five cases of columns with different aspect ratios, axial load ratios and ED bar ratios were analyzed with the SPOM and FIBM, respectively. Using these parametric results, a simplified design method was suggested by regressive analysis. Satisfactory correlation was found between the experimental results and the simplified design method for preeast segmental columns with different design parameters.展开更多
Tests of nine angle-steel concrete column (ASCC) specimens under low cyclic loading are described in a companion paper (Zheng and Ji, 2008). In this paper, the skeleton curves from the numerical simulation are pre...Tests of nine angle-steel concrete column (ASCC) specimens under low cyclic loading are described in a companion paper (Zheng and Ji, 2008). In this paper, the skeleton curves from the numerical simulation are presented, and show good agreement with the test results. Furthermore, parametric studies are conducted to explore the influence of factors such as the axial compression ratio, shear steel plate ratio, steel ratio, prismatic concrete compression strength, yield strength of angle steel and shear span ratio, etc., on the monotonic load-displacement curves of the ASCCs. Based on a statistical analysis of the calculated results, hysteretic models for load-displacement and moment-curvature are proposed, which agree well with the test results. Finally, some suggestions concerning the conformation of ASCCs are proposed, which could be useful in engineering practice.展开更多
This paper describes low cyclic loading testing of nine angle-steel concrete column (ASCC) specimens. In the tests, the influence of the shear-span ratio, axial compression ratio and shear steel plate ratio on the h...This paper describes low cyclic loading testing of nine angle-steel concrete column (ASCC) specimens. In the tests, the influence of the shear-span ratio, axial compression ratio and shear steel plate ratio on the hysteretic behavior, energy dissipation, strength degradation, stiffness degradation, skeleton curve and ductility of the ASCCs is studied. Based on the test results, some conclusions are presented. The P-A and sectional M -φ hysteretic models for the ASCCs are presented in a companion paper (Zheng and Ji, 2008).展开更多
Isolation of high quality DNA from multiple samples can be both time-consuming and expensive. We have developed a combined protocol to reduce the time component of the hexadecyltrimethylammonium bromide (CTAB) extra...Isolation of high quality DNA from multiple samples can be both time-consuming and expensive. We have developed a combined protocol to reduce the time component of the hexadecyltrimethylammonium bromide (CTAB) extraction method and reduced costs by regenerating the silica columns used to purify genomic DNA. We present data that shows, by in- creasing the temperature used during the CTAB method, the time required to extract crude genomic DNA can be reduced. We show that silica columns can be regenerated using HCI and still maintain their DNA-binding capacity. Furthermore, we show both spectrophotometrically, and by restriction enzyme cutting, that the quality of the eluted DNA is high. Critically, using both genomic DNA from pea and perennial ryegrass we demonstrate, using species-specific PCR primers, that there is no carry-over of DNA from repeated use of a single column. The main advantages of the method are high yield, high quality, cost effectiveness and time-saving. This method could satisfy demand when large numbers of plant genomic DNA samples are required, for example from targeting induced local lesions in genomes (TILLING) populations.展开更多
Experiments and simulations were conducted for bubble columns with diameter of 0.2 m(180 mm i.d.), 0.5 m(476 mm i.d.) and 0.8 m(760 mm i.d.) at high superficial gas velocities(0.12–0.62 m·s-1) and high solid con...Experiments and simulations were conducted for bubble columns with diameter of 0.2 m(180 mm i.d.), 0.5 m(476 mm i.d.) and 0.8 m(760 mm i.d.) at high superficial gas velocities(0.12–0.62 m·s-1) and high solid concentrations(0–30 vol%). Radial profiles of time-averaged gas holdup, axial liquid velocity, and turbulent kinetic energy were measured by using in-house developed conductivity probes and Pavlov tubes. Effects of column diameter, superficial gas velocity, and solid concentration were investigated in a wide range of operating conditions. Experimental results indicated that the average gas holdup remarkably increases with superficial gas velocity, and the radial profiles of investigated flow properties become steeper at high superficial gas velocities. The axial liquid velocities significantly increase with the growth of the column size, whereas the gas holdup was slightly affected. The presence of solid in bubble columns would inhibit the breakage of bubbles, which results in an increase in bubble rise velocity and a decrease in gas holdup, but time-averaged axial liquid velocities remain almost the same as that of the hollow column. Furthermore, a 2-D axisymmetric k–ε model was used to simulate heterogeneous bubbly flow using commercial code FLUENT 6.2. The lateral lift force and the turbulent diffusion force were introduced for the determination of gas holdup profiles and the effects of solid concentration were considered as the variation of average bubble diameter in the model. Results predicted by the CFD simulation showed good agreement with experimental data.展开更多
We present comparisons of the NO2 regional Chemical Transport Model (CTM) simulations over North-eastern North America during the time period from May to September, 1998 with hourly surface NO2 observations and the ...We present comparisons of the NO2 regional Chemical Transport Model (CTM) simulations over North-eastern North America during the time period from May to September, 1998 with hourly surface NO2 observations and the NO2 columns retrieved from the GOME (Global Ozone Monitoring Experiment) satellite instrument. The model calculations were performed using the Mesoscale Meteorological Model 5 (MM5), Sparse Matrix Operator Kernal Emissions (SMOKE), and Community Multiscale Air Quality (CMAQ) modeling systems, using the emission data from the National Emissions Inventory (NEI) databases of 1996 (U.S.) and 1995 (Canada). The major objectives were to assess the performance of the CMAQ model and the accuracy of the emissions inventories as they affected the simulations of this important short-lived atmospheric species. The modeled (NcMAQ) and measured (NGOME) NO2 column amounts, as well as their temporal variations, agreed reasonably well. The absolute differences (NcMAQ-NGOME) across the domain were between ±3.0×10^15 molecules cm^-2, but they were less than ±1.0×10^15 molecules cm^-2 over the majority (80%) of the domain studied. The overall correlation coefficient between the measurements and the simulations was 0.75. The differences were mainly ascribed to a combination of inaccurate emission data for the CTM and the uncertainties in the GOME retrievals. Of these, the former were the more easily identifiable.展开更多
An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic later...An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic lateral loading. Two parameters, replacement percentage of recycled coarse aggregate (RCA) and axial compression level, were considered in the test. Based on the experimental data, the hysteretic loops, skeleton curves, ductility, energy dissipation capacity and stiffness degradation of RCFST columns were analyzed. The test results indicate that the failure modes of RCFST columns are the local buckling of the steel tube at the bottom of the columns, and the hysteretic loops are full and their shapes are similar to normal CFST columns. Furthermore, the ductility coefficient of all specimens are close to 3.0, and the equivalent viscous damping coefficient corresponding to the ultimate lateral load ranges from 0.323 to 0.360, which demonstrates that RCFST columns exhibit remarkable seismic performance.展开更多
文摘Hydrodynamics characterization in terms offlow regime behavior is a crucial task to enhance the design of bubble column reactors and scaling up related methodologies.This review presents recent studies on the typicalflow regimes established in bubble columns.Some effort is also provided to introduce relevant definitions pertaining to thisfield,namely,that of“void fraction”and related(local,chordal,cross-sectional and volumetric)variants.Experimental studies involving different parameters that affect design and operating conditions are also discussed in detail.In the second part of the review,the attention is shifted to cases with internals of various types(perfo-rated plates,baffles,vibrating helical springs,mixers,and heat exchanger tubes)immersed in the bubble columns.It is shown that the presence of these elements has a limited influence on the global column hydrodynamics.However,they can make the homogeneousflow regime more stable in terms of transition gas velocity and transi-tion holdup value.The last section is used to highlight gaps which have not beenfilled yet and future directions of investigation.
基金funded by the‘Research Project of the Sucheng to Sihong Section of the Yanluo Expressway-Measurement Technology and Application of Bridge Quality Project Based on UAV Binocular Imaging(No.00-00-JSFW-20230203-029)’,received by H.Z.Wang.
文摘Pitting corrosion is harmful during bridge construction,which will lead to uneven roughness of steel surfaces and reduce the thickness of steel.Hence,the effect of pitting corrosion on the mechanical properties of cold-formed thin-walled steel stub columns is studied,and the empirical formulas are established through regression fitting to predict the ultimate load of web and flange under pitting corrosion.In detail,the failure modes and load-displacement curves of specimens with different locations,area ratios,and depths are obtained through a large number of non-linear finite element analysis.As for the specimens with pitting corrosion on the web,all the specimens are subject to local buckling failure,and the failure mode will not change with pitting corrosion,but the failure location will change with pitting corrosion location;the size,location,and area ratio of pitting corrosion have little influence on the ultimate load of cold-formed thin-walled steel short columns,but the loss rate of pitting corrosion section area has a greater impact on the ultimate bearing capacity.As for the specimen with flange pitting corrosion,the location and area ratio of pitting corrosion have less influence on the ultimate load of cold-formed thin-walled steel short columns,and the section area loss rate has greater influence on the ultimate bearing capacity;the impact of web pitting corrosion on the ultimate load is greater than that of flange pitting corrosion under the same condition of pitting corrosion section area.The prediction formulas of limit load which are suitable for pitting corrosion of web and flange are established,which can provide a reference for performance evaluation of corroded cold-formed thin-walled steel.
基金the National Natural Science Foundation of China(21625603)for supporting this work。
文摘The constant bubble size modeling approach(CBSM)and variable bubble size modeling approach(VBSM)are frequently employed in Eulerian–Eulerian simulation of bubble columns.However,the accuracy of CBSM is limited while the computational efficiency of VBSM needs to be improved.This work aims to develop method for bubble size modeling which has high computational efficiency and accuracy in the simulation of bubble columns.The distribution of bubble sizes is represented by a series of discrete points,and the percentage of bubbles with various sizes at gas inlet is determined by the results of computational fluid dynamics(CFD)–population balance model(PBM)simulations,whereas the influence of bubble coalescence and breakup is neglected.The simulated results of a 0.15 m diameter bubble column suggest that the developed method has high computational speed and can achieve similar accuracy as CFD–PBM modeling.Furthermore,the convergence issues caused by solving population balance equations are addressed.
基金National Natural Science Foundation of China under Grant No.51778248Natural Science Foundation of Fujian Province under Grant No.2018J01075+1 种基金Education and Science Project for Young and Middle-aged Teacher of Fujian Province under Grant No.JAT200825Research Trained Fund for Outstanding Young Researcher in Higher Education Institutions of Fujian Province。
文摘To enable rapid recovery of a steel bridge column after an earthquake,a novel tubular-section steel bridge column equipped with low-yield-point(LYP)steel tubular plates in the root replaceable pier is proposed.For the purpose of discussing the seismic behavior of the novel steel bridge column,quasi-static tests and finite element simulation analyses of the specimens were carried out.The effects of parameters such as the axial compression ratio,eccentricity,and thickness and material strength of the tubular plate in the energy-dissipating zone are discussed.Experimental results from seven specimens that were subjected to four failure modes are presented.The damage to the quasi-static specimens is localized to the replaceable energy-dissipating pier.The seismic behavior of the novel steel bridge columns is significantly influenced by the axial compression ratio and eccentricity of specimens.Numerical results show that the high stress area of the specimens is mainly concentrated in the connection zone between the LYP steel tubular plate and the bottom steel plate,which is consistent with the position of the quasi-static specimen when it was prone to fracture.Finally,a calculation formula is proposed to facilitate the capacity prediction of this new steel tubular bridge column under repeated loading.
基金The financial support from National Natural Science Foundation of China (21878011)。
文摘For dividing-wall distillation columns(DWDCs) separating a heavy-component dominated and wide boiling-point ternary(HCDWBT) mixture, a significant amount of excessive heat exists inevitably in stripping the heavy-component from the intermediate-component and it can be employed to initiate the development of vapor recompression heat pump(VRHP) assisted DWDC(VRHP-DWDC). Despite dividing wall may locate in the top, middle, and bottom, the optimum VRHP-DWDC is found to involve uniformlytwo VRHP circles. While the first one serves to compress and transform the excessive heat resulted from the separation of the heavy-component from the intermediate-component, the second one to compress and transform the overhead vapor stream of the light-component pre-heated sequentially with the condensate from the first one and the bottom product stream of the heavy-component, both releasing the temperature-elevated latent heat to the pre-fractionator's or common stripping section. The processing of two HCDWBT mixtures of benzene/toluene/o-xylene and n-pentane/n-hexane/n-heptane are selected to assess the derived optimum topological configurations of the VRHP-DWDC and their optimality is confirmed through detailed comparisons with the DWDC and two VRHP-DWDCs involving only one VRHP circle. The proposed strategy helps to tap the full potential of the VRHP-DWDC with considerably alleviated complication in process development.
文摘Monte Carlo simulation of gamma photon transport and interaction with the distillation column and its contents was performed in order to predict the effects of gamma photons when they interact with matter. The results of the interaction and transport of gamma photons are presented as energy deposition on the distillation column and its contents. Energy attenuation was more pronounced on the column walls and trays as compared to the region between the trays, where there is mostly vapour space. Gamma column scanning was then used to verify the Monte Carlo simulation results by scanning and investigating the integrity of two laboratory prototype distillation and industrial distillation columns. One of the prototype distillation columns was 1 m tall with four trays and the other one was 1.8 m tall consisting of six trays and a packed bed. Commonly encountered distillation column malfunctions such as collapsed tray, weeping, flooding and foaming were simulated in the two prototype distillation columns and scanned. The industrial distillation column was a 26 m tall benzole prefractionator column, consisting of 60 single pass trays and a diameter of 0.8 m. A 10 mCi <sup>60</sup>Co gamma radiation source and NaI(Tl) scintillation detector were used to scan the distillation columns. The results from the two prototypes showed that all the simulated malfunctions were clearly detected except for foaming. The results from industrial distillation column showed that all the trays were in their correct position although tray number 32 could be partially damaged and just below tray 41, the scan revealed that there was a loss of column wall thickness. The obtained density profile for the industrial distillation column showed some small variations from the expected density profile and this was attributed to external features on the distillation column and wind bursts that shifted the source and detector from the chosen scan line orientation.
文摘Eucalyptus nitens(E.nitens)has been much used for producing paper but also shows promise for structural applications.In this study,static compressive tests were undertaken to examine its suitability to be used in an innovative composite column.The composite column was comprised of a rectangular steel tube with E.nitens timber infill.The nonlinear compressive behaviour of the composite column filled with E.nitens wood for both dry and wet conditions was examined.The same tests on rectangular steel tubes and bare dry and wet E.nitens samples were also undertaken as a comparison.For samples with different conditions,the ultimate capacity was evaluated and the effect of each condition on the compressive behaviour of the composite column was clarified.The steel tubes showed greater ductile behaviour,and more ductility was found in the wet samples.The steel tubes with E.nitens timber infill samples exhibited a greater linear elastic range connected with higher maximum loads,while the bare timber samples could support only lower maximum loads.The results from this research were promising for the use of rectangular steel tubes with E.nitens timber infill in structural applications.
文摘The vapor recompression heat pump(VRHP) distillation technology offers significant improvements in energy efficiency for distillation systems with small temperature differences between the top and bottom of the column. However, the separation of wide-boiling binary mixtures leads to substantial temperature differences between the top and bottom of the column. This limits the applicability of conventional VRHP due to high capital costs and strict performance requirements of the compressor. To overcome these challenges and to accommodate compressor operating conditions, a novel synthesis and design method is introduced to integrate VRHPs with wide-boiling binary mixture distillation columns(WBMDCs). This method enables quick determination of an initial configuration for the integrated WBMDC-VRHP system and helps identify the optimum configuration with the minimum total annual cost. Two examples, namely the separation of benzene/toluene and isopropanol/chlorobenzene, are employed to derive optimum configurations of the WBMDC-VRHP and compare them with the WBMDC. A systematic comparison between the WBMDC-VRHP and WBMDC demonstrates the superior steady-state performance and economic efficiency of the WBMDC-VRHP.
基金supported by the National Natural Science Foundation of China(51679247)。
文摘During a sea firing training,the intelligent detection of projectile-induced water column targets in a firing video is the prerequisite for and critical to the automatic calculation of miss distance,while the correct and precise calculation of miss distance is directly affected by the accuracy,false alarm rate and time delay of detection.After analyzing the characteristics of projectile-induced water columns,an accurate detection algorithm for time backtracked projectile-induced water columns based on the improved you only look once(YOLO)network is put forward.The capability and accuracy of detecting projectileinduced water column targets with the conventional YOLO network are improved by optimizing the anchor box through K-means clustering and embedding the squeeze and excitation(SE)attention module.The detection area is limited by adopting a sea-sky line detection algorithm based on gray level co-occurrence matrix(GLCM),so as to effectively eliminate such disturbances as ocean waves and ship wakes,and lower the false alarm rate of projectile-induced water column detection.The improved algorithm increases the mAP50 of water column detection by 30.3%.On the basis of correct detection,a time backtracking algorithm is designed with mean shift to track images containing projectile-induced water column in reverse time sequence.It accurately detects a projectile-induced water column at the time of its initial appearance as well as its pixel position in images,and considerably reduces detection delay,so as to provide the support for the automatic,accurate,and real-time calculation of miss distance.
文摘During the modernization or rehabilitation activity,the demolished structural waste causes large soil pollution and unavailability of natural aggregate is the big concern for the construction industry.Therefore,this manuscript deals with the Composite Steel Circular Column(CSCC)with Recycled Aggregate concrete(RAC)as infill is partly used,with the replacement of 25%and 50%in M30 grade of Concrete.And internal reinforcement steel is fully replaced by rolled steel tubes(circular and square)with varied thickness,ISA-unequal angle.Around 14 specimens are cast and examined under axial load for analysis of the deflection characteristics,the load-bearing capacity along with its buckling behavior.The experimental values are estimated through LVDT(linear variable differential transducer)at 3-phase.The curve of load-deflection is drawn with the load pattern.From the date interpretation,it is found column made of 50%-RAC has more than 25%-RAC.
基金financial support from National Natural Science Foundation of China(22108263)Shanxi Province Basic Research Program Project(20210302124060)the 18th Graduate Student Technology Project of North University of China(20221824).
文摘The addition of dispersed-phase nanoparticles in the liquid phase can enhance the gas-liquid transfer process as the suspended nanoparticles affect the transfer process inside the fluid through microdisturbance or micro-convection effects.In this article,a high-speed digital camera was used to visualize the bubble behavior of CO_(2) in pure water and nanofluids to examine the effects of CO_(2) gas flow rate,nanoparticle solid content and type on the bubble behavior in the fluids.The CO_(2) absorption performance in three water-based nanofluids were compared in a bubbler.And the mass transfer characteristics during CO_(2) bubble absorption and the reasons for the enhanced gas-liquid mass transfer effect of nanoparticles were analyzed.The results showed that the presence of nanoparticles affected the formation process of bubbles in the fluid,shortened the bubble detachment time,reduced the detachment diameter,effectively increased the gas-liquid contact area,and improved the bubbles detachment frequency.The system with MCM-41 corresponded to a higher overall mass transfer coefficient.Uncalined MCM-41 contained surfactant that enhanced foaming behavior in water.This prevented the transfer of CO_(2) to some extent,and the CO_(2) absorption by uncalined MCM-41/H_(2)O was 5.34%higher than that by pure water.Compared with SiO_(2) nanoparticles with the same particle size and the same composition,MCM-41 had a higher adsorption capacity and better hydrophilicity due to its larger specific surface area and rich porous structure,which was more favorable to accelerate the collision between nanoparticles and CO_(2) bubbles to cause micro-convection.Under the condition of 0.1%(mass)solid content,the enhancement of CO_(2) absorption process by MCM-41 nanoparticles was more significant and improved by 16.9%compared with pure water.
文摘This manuscript presents a dataset detailing a method for purifying monomers. Purification plays a crucial role in every chemical process, as it leads to an improvement in product quality through the removal of impurities. The primary method for monomer purification, like acrylonitrile (AN), is the distillation technique. However, this technique is unsafe and hard to set up or handle. A straightforward, risk-free, low-cost method like the column technique resolves these issues. A simple column technique demonstrated the successful execution of purifying AN. Fourier transform infrared (FTIR) and nuclear magnetic resonance (NMR) analyses confirmed that AN was successfully purified, with purity reaching 99.8%. FTIR spectra revealed changes in the position and intensity of the stretching vibration peaks after purification. Also, the functional groups of the inhibitor monomethyl ether of hydroquinone (MeHQ) were undetected after purification. Furthermore, after purification, NMR spectra revealed the absence of aromatic protons and carbons associated with MeHQ. In conclusion, the column technique is a successful and inexpensive way to purify AN monomers. This makes it useful for a wide range of applications, especially in polymerization reactions where MeHQ needs to be removed to prevent self-polymerization during the initiation process.
基金Supported by the National Natural Science Foundation (51208268)the Pubiic-Welfare-Technology Research Industry Project of Science Technology Department of Zhejiang (2011 C21078) the Social Development Project of Science Technology Bureau of Ningbo (2011CS0017).
基金National Natural Science Foundation of China under Grants Nos.51208268 and 51178429K.C.Wong Magna Fund in Ningbo University+1 种基金Transportation Science and Technology Project of Ningbo City under Grant No.201507Natural Science Foundation of Ningbo City under Grant No.2015A610293
文摘In recent years, precast segmental concrete bridge columns became prevalent because of the benefits of accelerated construction, low environmental impact, high quality and low life cycle costs. The lack of a detailed configuration and appropriate design procedure to ensure a comparable performance with monolithic construction has impeded this structural system from being widely used in areas of high seismicity. In this study, precast segmental bridge column cyclic loading tests were conducted to investigate the performance of unbonded post-tensioned segmental bridge columns. One monolithic and two precast segmental columns were tested. The preeast segmental column exhibited minor damage and small residual displacement after the maximum 7% cyclic drift; energy dissipation (ED) can be enhanced byadding ED bars. The experimental results were modeled by a simplified pushover method (SPOM), as well as a fiber model (FIBM) finite element method. Forty-five cases of columns with different aspect ratios, axial load ratios and ED bar ratios were analyzed with the SPOM and FIBM, respectively. Using these parametric results, a simplified design method was suggested by regressive analysis. Satisfactory correlation was found between the experimental results and the simplified design method for preeast segmental columns with different design parameters.
基金the New Century Excellent Talents in University Under Grant No.290Heilongjiang Key Program on Science and Technology Under Grant No. GC04A609arbin Key Program on Science and Technology Under Grant No. 2004AA9CS187.
文摘Tests of nine angle-steel concrete column (ASCC) specimens under low cyclic loading are described in a companion paper (Zheng and Ji, 2008). In this paper, the skeleton curves from the numerical simulation are presented, and show good agreement with the test results. Furthermore, parametric studies are conducted to explore the influence of factors such as the axial compression ratio, shear steel plate ratio, steel ratio, prismatic concrete compression strength, yield strength of angle steel and shear span ratio, etc., on the monotonic load-displacement curves of the ASCCs. Based on a statistical analysis of the calculated results, hysteretic models for load-displacement and moment-curvature are proposed, which agree well with the test results. Finally, some suggestions concerning the conformation of ASCCs are proposed, which could be useful in engineering practice.
基金the New Century Excellent Talents in University Under Grant No.290Heilongjiang Key Program on Science and Technology Under Grant No.GC04A609Harbin Key Program on Science and Technology Under Grant No.2004AA9CS187
文摘This paper describes low cyclic loading testing of nine angle-steel concrete column (ASCC) specimens. In the tests, the influence of the shear-span ratio, axial compression ratio and shear steel plate ratio on the hysteretic behavior, energy dissipation, strength degradation, stiffness degradation, skeleton curve and ductility of the ASCCs is studied. Based on the test results, some conclusions are presented. The P-A and sectional M -φ hysteretic models for the ASCCs are presented in a companion paper (Zheng and Ji, 2008).
基金funding and the PhD Scholarship for Fu Zeyu from the New Zealand Foundation for Arable Researchfunding for Song Jiancheng from the National Natural Science Foundation of China (31371616)
文摘Isolation of high quality DNA from multiple samples can be both time-consuming and expensive. We have developed a combined protocol to reduce the time component of the hexadecyltrimethylammonium bromide (CTAB) extraction method and reduced costs by regenerating the silica columns used to purify genomic DNA. We present data that shows, by in- creasing the temperature used during the CTAB method, the time required to extract crude genomic DNA can be reduced. We show that silica columns can be regenerated using HCI and still maintain their DNA-binding capacity. Furthermore, we show both spectrophotometrically, and by restriction enzyme cutting, that the quality of the eluted DNA is high. Critically, using both genomic DNA from pea and perennial ryegrass we demonstrate, using species-specific PCR primers, that there is no carry-over of DNA from repeated use of a single column. The main advantages of the method are high yield, high quality, cost effectiveness and time-saving. This method could satisfy demand when large numbers of plant genomic DNA samples are required, for example from targeting induced local lesions in genomes (TILLING) populations.
基金Supported by the National High Technology Research and Development Program of China(2011AA05A205)the National Natural Science Foundation of China(U1162125,U1361112)
文摘Experiments and simulations were conducted for bubble columns with diameter of 0.2 m(180 mm i.d.), 0.5 m(476 mm i.d.) and 0.8 m(760 mm i.d.) at high superficial gas velocities(0.12–0.62 m·s-1) and high solid concentrations(0–30 vol%). Radial profiles of time-averaged gas holdup, axial liquid velocity, and turbulent kinetic energy were measured by using in-house developed conductivity probes and Pavlov tubes. Effects of column diameter, superficial gas velocity, and solid concentration were investigated in a wide range of operating conditions. Experimental results indicated that the average gas holdup remarkably increases with superficial gas velocity, and the radial profiles of investigated flow properties become steeper at high superficial gas velocities. The axial liquid velocities significantly increase with the growth of the column size, whereas the gas holdup was slightly affected. The presence of solid in bubble columns would inhibit the breakage of bubbles, which results in an increase in bubble rise velocity and a decrease in gas holdup, but time-averaged axial liquid velocities remain almost the same as that of the hollow column. Furthermore, a 2-D axisymmetric k–ε model was used to simulate heterogeneous bubbly flow using commercial code FLUENT 6.2. The lateral lift force and the turbulent diffusion force were introduced for the determination of gas holdup profiles and the effects of solid concentration were considered as the variation of average bubble diameter in the model. Results predicted by the CFD simulation showed good agreement with experimental data.
文摘We present comparisons of the NO2 regional Chemical Transport Model (CTM) simulations over North-eastern North America during the time period from May to September, 1998 with hourly surface NO2 observations and the NO2 columns retrieved from the GOME (Global Ozone Monitoring Experiment) satellite instrument. The model calculations were performed using the Mesoscale Meteorological Model 5 (MM5), Sparse Matrix Operator Kernal Emissions (SMOKE), and Community Multiscale Air Quality (CMAQ) modeling systems, using the emission data from the National Emissions Inventory (NEI) databases of 1996 (U.S.) and 1995 (Canada). The major objectives were to assess the performance of the CMAQ model and the accuracy of the emissions inventories as they affected the simulations of this important short-lived atmospheric species. The modeled (NcMAQ) and measured (NGOME) NO2 column amounts, as well as their temporal variations, agreed reasonably well. The absolute differences (NcMAQ-NGOME) across the domain were between ±3.0×10^15 molecules cm^-2, but they were less than ±1.0×10^15 molecules cm^-2 over the majority (80%) of the domain studied. The overall correlation coefficient between the measurements and the simulations was 0.75. The differences were mainly ascribed to a combination of inaccurate emission data for the CTM and the uncertainties in the GOME retrievals. Of these, the former were the more easily identifiable.
基金the National Natural Science Foundation of China under Grant Nos.51268004 and 51578163the Guangxi Science and Technology Key Project under Grant No.12118023-3
文摘An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic lateral loading. Two parameters, replacement percentage of recycled coarse aggregate (RCA) and axial compression level, were considered in the test. Based on the experimental data, the hysteretic loops, skeleton curves, ductility, energy dissipation capacity and stiffness degradation of RCFST columns were analyzed. The test results indicate that the failure modes of RCFST columns are the local buckling of the steel tube at the bottom of the columns, and the hysteretic loops are full and their shapes are similar to normal CFST columns. Furthermore, the ductility coefficient of all specimens are close to 3.0, and the equivalent viscous damping coefficient corresponding to the ultimate lateral load ranges from 0.323 to 0.360, which demonstrates that RCFST columns exhibit remarkable seismic performance.