期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Comparing Two Methods for Measuring Soil Bulk Density and Moisture Content 被引量:1
1
作者 Jalal D. Jabro William B. Stevens William M. Iversen 《Open Journal of Soil Science》 2020年第6期233-243,共11页
<span style="font-family:Verdana;">Soil bulk density and moisture content are dynamic properties that vary with changes in soil and field conditions and have many agricultural, hydrological and environ... <span style="font-family:Verdana;">Soil bulk density and moisture content are dynamic properties that vary with changes in soil and field conditions and have many agricultural, hydrological and environmental implications. The main objective of this study was to compare between a soil core sampling method (core) and the CPN MC-3 Elite<span style="white-space:nowrap;"><sup>TM</sup></span> nuclear gauge method (radiation) for measuring bulk density (<span style="white-space:nowrap;"><i><span style="font-family:Verdana;white-space:normal;"></span><span style="font-family:Verdana;white-space:normal;"><span style="white-space:nowrap;"><i>ρ<sub>B</sub></i></span></span></i></span>) and volumetric moisture content (<span style="white-space:nowrap;"><i><span style="font-family:Verdana;white-space:normal;"><span style="white-space:nowrap;"><i>θ<span style="font-size:10.9091px;">v</span></i></span></span></i></span>) in a clay loam soil. Soil <span style="white-space:nowrap;"><i><span style="font-family:Verdana;white-space:normal;"><span style="white-space:nowrap;"><i>ρ<sub>B</sub></i></span></span></i></span> and <span style="white-space:nowrap;"><i><span style="font-family:Verdana;white-space:normal;"></span><span style="font-family:Verdana;white-space:normal;"><span style="white-space:nowrap;"><i>θ<span style="font-size:10.9091px;">v</span></i></span></span></i></span> measurements were determined using the core and radiation methods at 0 - 10 and 10 - 20 cm soil depths. The mean values of soil <span style="white-space:nowrap;"><i><span style="font-family:Verdana;white-space:normal;"><span style="white-space:nowrap;"><i>ρ<sub>B</sub></i></span></span></i></span> obtained using the core method (1.454, 1.492 g<span style="color:#4F4F4F;font-family:" font-size:14px;white-space:normal;background-color:#f7f7f7;"="">·</span>cm<span style="white-space:nowrap;"><sup>&minus;3</sup></span>) were greater than those obtained using the radiation method (1.343, 1.476 g<span style="color:#4F4F4F;font-family:" font-size:14px;white-space:normal;background-color:#f7f7f7;"="">·</span>cm<span style="white-space:nowrap;"><sup>&minus;3</sup></span>) at the 0 - 10 and 10 - 20 cm depths, respectively. Mean <span style="white-space:nowrap;"><i><span style="font-family:Verdana;white-space:normal;"><span style="white-space:nowrap;"><i>ρ<sub>B</sub></i></span></span></i></span> and <span style="white-space:nowrap;"><i><span style="font-family:Verdana;white-space:normal;"><span style="white-space:nowrap;"><i>θ<span style="font-size:10.9091px;">v</span></i></span></span></i></span> values averaged across both depths (referred to as the 0 - 20 cm depth) measured by the core method were 4.47% and 22.74% greater, respectively, than those obtained by the radiation method. The coefficients of variation (CV) of soil <span style="white-space:nowrap;"><i><span style="font-family:Verdana;white-space:normal;"></span><span style="font-family:Verdana;white-space:normal;"><span style="white-space:nowrap;"><i>ρ<sub>B</sub></i></span></span></i></span> values measured by the core method were lower than the CV values of those measured by the radiation method at both depths;however, the CV’s of <span style="white-space:nowrap;"><i><span style="font-family:Verdana;white-space:normal;"><span style="white-space:nowrap;"><i>ρ<sub>B</sub></i></span></span></i></span> values for both methods were larger at the 0 - 10 cm depth than those measured at the 10 - 20 cm depth. Similarly, the CV values of soil <span style="white-space:nowrap;"><i><span style="font-family:Verdana;white-space:normal;"><span style="white-space:nowrap;"><i>θ<sub>v</sub></i></span></span></i></span> values measured by the core method were lower than the CV values of those measured by the radiation method at both depths. There were significant differences between two methods in terms of <span style="white-space:nowrap;"><i><span style="font-family:Verdana;white-space:normal;"><span style="white-space:nowrap;"><i>ρ<sub>B</sub></i></span></span></i></span> and <span style="white-space:nowrap;"><i><span style="font-family:Verdana;white-space:normal;"><span style="white-space:nowrap;"><i>θ<sub>v</sub></i></span></span></i></span>, with the core method generating greater values than the radiation method at the 0 - 20 cm depth. These discrepancies between the two methods could have resulted from soil compaction and soil disturbance caused by the core and radiation techniques, respectively, as well as by other sources of error. Nevertheless, the core sampling method is considered the most common one for measuring <span style="white-space:nowrap;"><i><span style="font-family:Verdana;white-space:normal;"><span style="white-space:nowrap;"><i>ρ<sub>B</sub></i></span></span></i></span> for many agricultural, hydrological and environmental studies in most soils.</span> 展开更多
关键词 SOIL Bulk Density Moisture Content Core method Radiation method
下载PDF
Diversified Teaching Methods in Nursing:Using Animal Experimentation to Promote Core Professional Competencies in Basic Nursing Training 被引量:1
2
作者 Hui Lin Wei Wang Yin-Jun Ye 《Chinese Nursing Research》 CAS 2015年第4期155-159,共5页
Objective: The aim of this project was to train highly professional and specialized nursing students from medical colleges to adapt to bedside clinical care by exploring and discussing various methods of injection an... Objective: The aim of this project was to train highly professional and specialized nursing students from medical colleges to adapt to bedside clinical care by exploring and discussing various methods of injection and IV infusion in animal experimentation to hone the core professional nursing competencies. Methods: Two classes from the 2012 senior graduating nursing class were randomly selected by a computer to conduct the diversified practical teaching methods based on animal experimentation. A hospital environment was simulated by requiring students to perform different types of injections and practical IV infusion techniques. A comprehensive evaluation of the core professional competencies, as well as other integrated competencies, was conducted to determine the effectiveness of the teaching methods. Results: Two-sampled, pairwise u-tests were performed between the scores of the experimental (nursing class 2) and control (nursing class 1) groups. These findings showed that the overall test scores were significantly higher in the experimental group compared to the control group and that the average P-values for the competencies in various categories were 〈0.01, which indicated statistically significant results. Conclusions: Based on the data from this project, diversified teaching methods for basic nursing training founded on animal experimentation can help nursing students perfect their core professional competencies and improve their overall professional standing. The introduction of animal experimentation requires further verification, and an increased acknowledgement of its benefits through the widespread dissemination of this information. 展开更多
关键词 Core professional competencies Basic nursing Experimentation on animals Diversified teaching methods
下载PDF
Magic wavelengths for 6s_(1/2)→5d_(3/2,5/2)transitions of Yb~+ions
3
作者 陈婷 吴磊 +3 位作者 张儒奎 唐永波 蒋军 董晨钟 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第5期405-412,共8页
The wave functions,energy levels and matrix elements of Yb+ions are calculated using the relativistic configuration interaction plus core polarization(RCICP)method.The static and dynamic electric dipole polarizabiliti... The wave functions,energy levels and matrix elements of Yb+ions are calculated using the relativistic configuration interaction plus core polarization(RCICP)method.The static and dynamic electric dipole polarizabilities of the ground state and low-lying excited states are determined.Then,the magic wavelengths of the magnetic sublevel 6s_(1/2,m=1/2)→5d_(3/2,m=±3/2,±1/2)and 6s_(1/2,m=1/2)→5_(d5/2,m=±5/2,±3/2,±1/2)transitions in the linearly,right-handed,and left-handed polarized light are further determined.The dependence of the magic wavelengths upon the angle between the direction of magnetic field and the direction of laser polarization is analyzed. 展开更多
关键词 matrix elements POLARIZABILITIES magic wavelengths relativistic configuration interaction plus core polarization(RCICP)method
下载PDF
Charge density at the nucleus and radial behavior of ground state for lithium-like ions with Z=21 to 30 被引量:1
4
作者 于伟威 王治文 +2 位作者 陈超 蔡娟 张楠 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第7期229-234,共6页
By using the full-core plus correlation (FCPC) type wave functions, the accurate charge densities p(0) at the nucleus and the radial expectation values of the ground states for the lithium-like systems with Z =- 2... By using the full-core plus correlation (FCPC) type wave functions, the accurate charge densities p(0) at the nucleus and the radial expectation values of the ground states for the lithium-like systems with Z =- 21 to 30 are obtained. The determinantal conditions and the electron-nucleus cusp condition are used to calculate the inequalities of the upper and the lower bounds to p(0) with two or more expectation values. These inequalities, derived by Angulo and Dehesa [Phys. Rev. A 44 1516 (1991)], are verified to be also valid for these ions with higher nuclear charge. The present results show that the wave functions used in this paper are satisfactory in the whole configuration space for these ions with higher nuclear charge. 展开更多
关键词 electron density radial expectation values upper and lower bounds full core plus cor- relation method
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部