AIM: To analyze the correlations between ocular biomechanical and biometric data of the eye,measured by Scheimpflug-based devices on healthy subjects.METHODS: Three consecutive measurements were carried out using th...AIM: To analyze the correlations between ocular biomechanical and biometric data of the eye,measured by Scheimpflug-based devices on healthy subjects.METHODS: Three consecutive measurements were carried out using the corneal visualization Scheimpflug technology(Cor Vis ST) device on healthy eyes and the 10 device-specific parameters were recorded.Pentacam HR-derived parameters(corneal curvature radii on the anterior and posterior surfaces;apical pachymetry;corneal volume;corneal aberration data;depth,volume and angle of the anterior chamber) and axial length(AL) from IOLMaster were correlated with the 10 specific CorV is ST parameters.RESULTS: Measurements were conducted in 43 eyes of 43 volunteers(age 61.24±15.72y).The 10 specific Cor Vis ST data showed significant relationships with corneal curvature radii both on the anterior and posterior surface,pachymetric data,root mean square(RMS) data of lower-order aberrations,and posterior RMS of higher-order aberrations and spherical aberration of the posterior cornea.Anterior chamber depth showed a significant relationship,but there were no significant correlations between corneal volume,anterior chamber volume,mean chamber angle or AL and the 10 specific CorV is ST parameters.CONCLUSION: Cor Vis ST-generated parameters are influenced by corneal curvature radii,some corneal RMS data,but corneal volume,anterior chamber volume,chamber angle and AL have no correlation with the biomechan-ical parameters.The parameters measured by CorV is ST seem to refer mostly to corneal properties of the eye.展开更多
目的:比较角膜生物力学分析仪(Corvis ST)、A型超声测厚仪(A超)、Lenstar LS 900(Lenstar)在测量近视眼角膜厚度的差异,为屈光术前筛查提供参考。方法:纳入2020年3至12月佛山市第二人民医院收治的屈光术前近视患者244例(244只右眼),并...目的:比较角膜生物力学分析仪(Corvis ST)、A型超声测厚仪(A超)、Lenstar LS 900(Lenstar)在测量近视眼角膜厚度的差异,为屈光术前筛查提供参考。方法:纳入2020年3至12月佛山市第二人民医院收治的屈光术前近视患者244例(244只右眼),并按中央角膜厚度(central corneal thickness,CCT)将患者分为3组:薄角膜组(CCT≤520μm)、正常角膜组(520μm<CCT≤570μm)、厚角膜组(CCT>570μm),分别采用Corvis ST、A超、Lenstar三种仪器测量3组患者的中央角膜厚度,并纳入对比指标。结果:Cor vis ST与A超、Lenstar在薄角膜组、正常角膜组、厚角膜组的测量值对比差异均有统计学意义(均P<0.05);在相关性方面,Corvis ST与A超、Lenstar在薄角膜组、正常角膜组、厚角膜组呈正相关(r=0.841,P<0.001 vs r=0.832,P<0.001;r=0.866,P<0.001 vs r=0.918,P<0.001;r=0.497,P<0.001 vs r=0.801,P<0.001);在一致性方面,Corvis ST与A超、Lenstar在薄角膜组、正常角膜组、厚角膜组上一致性系数ICC及95%置信区间分别为0.602(0.091,0.857),0.758(0.221,0.901)、0.741(0.207,0.890),0.845(0.396,0.938)、0.417(0.005,0.679),0.667(0.172,0.851),95%一致性区间范围分别是(−2.2~24.2μm,−6.7~19.5μm;−8.4~24.6μm,−6.8~19.4μm;−8.7~23.8μm,−7.0~18.3μm)。结论:通过对3组数据统计分析得出,Corvis ST与A超、Lens tar的测量值相比,差异均有统计学意义,且Corvis ST的测量值均高于后两种仪器;Cor vis ST与后两者均有着较高的相关性,且在正常角膜厚度测量上相关性最高;在一致性方面,从ICC点估计及95%置信区间数值分析,一致性较差;从Bland-Altman角度分析,Corvis ST与后两者的绝对值最大差值超过10μm,一致性较差,但在与Lenstar的绝对值最大差值均在20μm内。因此,在测量精度要求较高的屈光手术筛查方面,Corvis ST与A超、Lenstar之间不能相互替代,而对于大规模临床筛查,其角膜厚度测量值对眼压的影响有一定的临床参考意义。展开更多
文摘AIM: To analyze the correlations between ocular biomechanical and biometric data of the eye,measured by Scheimpflug-based devices on healthy subjects.METHODS: Three consecutive measurements were carried out using the corneal visualization Scheimpflug technology(Cor Vis ST) device on healthy eyes and the 10 device-specific parameters were recorded.Pentacam HR-derived parameters(corneal curvature radii on the anterior and posterior surfaces;apical pachymetry;corneal volume;corneal aberration data;depth,volume and angle of the anterior chamber) and axial length(AL) from IOLMaster were correlated with the 10 specific CorV is ST parameters.RESULTS: Measurements were conducted in 43 eyes of 43 volunteers(age 61.24±15.72y).The 10 specific Cor Vis ST data showed significant relationships with corneal curvature radii both on the anterior and posterior surface,pachymetric data,root mean square(RMS) data of lower-order aberrations,and posterior RMS of higher-order aberrations and spherical aberration of the posterior cornea.Anterior chamber depth showed a significant relationship,but there were no significant correlations between corneal volume,anterior chamber volume,mean chamber angle or AL and the 10 specific CorV is ST parameters.CONCLUSION: Cor Vis ST-generated parameters are influenced by corneal curvature radii,some corneal RMS data,but corneal volume,anterior chamber volume,chamber angle and AL have no correlation with the biomechan-ical parameters.The parameters measured by CorV is ST seem to refer mostly to corneal properties of the eye.
文摘目的:比较角膜生物力学分析仪(Corvis ST)、A型超声测厚仪(A超)、Lenstar LS 900(Lenstar)在测量近视眼角膜厚度的差异,为屈光术前筛查提供参考。方法:纳入2020年3至12月佛山市第二人民医院收治的屈光术前近视患者244例(244只右眼),并按中央角膜厚度(central corneal thickness,CCT)将患者分为3组:薄角膜组(CCT≤520μm)、正常角膜组(520μm<CCT≤570μm)、厚角膜组(CCT>570μm),分别采用Corvis ST、A超、Lenstar三种仪器测量3组患者的中央角膜厚度,并纳入对比指标。结果:Cor vis ST与A超、Lenstar在薄角膜组、正常角膜组、厚角膜组的测量值对比差异均有统计学意义(均P<0.05);在相关性方面,Corvis ST与A超、Lenstar在薄角膜组、正常角膜组、厚角膜组呈正相关(r=0.841,P<0.001 vs r=0.832,P<0.001;r=0.866,P<0.001 vs r=0.918,P<0.001;r=0.497,P<0.001 vs r=0.801,P<0.001);在一致性方面,Corvis ST与A超、Lenstar在薄角膜组、正常角膜组、厚角膜组上一致性系数ICC及95%置信区间分别为0.602(0.091,0.857),0.758(0.221,0.901)、0.741(0.207,0.890),0.845(0.396,0.938)、0.417(0.005,0.679),0.667(0.172,0.851),95%一致性区间范围分别是(−2.2~24.2μm,−6.7~19.5μm;−8.4~24.6μm,−6.8~19.4μm;−8.7~23.8μm,−7.0~18.3μm)。结论:通过对3组数据统计分析得出,Corvis ST与A超、Lens tar的测量值相比,差异均有统计学意义,且Corvis ST的测量值均高于后两种仪器;Cor vis ST与后两者均有着较高的相关性,且在正常角膜厚度测量上相关性最高;在一致性方面,从ICC点估计及95%置信区间数值分析,一致性较差;从Bland-Altman角度分析,Corvis ST与后两者的绝对值最大差值超过10μm,一致性较差,但在与Lenstar的绝对值最大差值均在20μm内。因此,在测量精度要求较高的屈光手术筛查方面,Corvis ST与A超、Lenstar之间不能相互替代,而对于大规模临床筛查,其角膜厚度测量值对眼压的影响有一定的临床参考意义。
基金Supported by Xi'an Social Development Research Project Grant[No.SF1513(2)]Shaanxi Social Development Research Project Grant(No.2016SF-274)Shaanxi Provincial Health Research Project(No.2016E002)~~
文摘目的:应用可视化角膜生物力学分析仪(Corvis ST)及眼反应分析仪(ORA)评估飞秒激光制瓣准分子激光原位角膜磨镶术(laser in situ keratomileusis,LASIK)术后角膜生物力学变化,并分析与其他参数的相关性。方法:收集63例飞秒制瓣LASIK手术患者,所有收集对象采用右眼数据进行分析。角膜生物力学测量仪器应用可视化角膜生物力学分析仪Corvis ST及眼反应分析仪ORA,手术前及手术后1mo进行生物力学数据采集分析。配对t检验或Mann-Whitney U检验进行手术前后生物力学对比分析。Pearson或Spearman统计学方法进行相关性分析。结果:与FS-LASIK手术前相比,手术后1stA-time,Vin,2ndA length,Vout以及Radius下降,有统计学差异(P=0.00,P=0.00,P=0.00,P=0.00,P=0.00)。2ndA-time,DA以及PD手术后增加,有统计学差异(P=0.00,P=0.00,P=0.00)。1stA length以及HC time手术后改变不明显,无统计学差异(P=0.96,P=0.08)。与FS-LASIK手术前相比,手术后CH,CRF下降,有统计学差异(P=0.00,P=0.00)。手术后1stA-time,2ndA-time,DA and Radius变化量与手术前角膜中央厚度有明显相关性(P=0.01,P=0.04,P=0.03,P=0.01)。结论:飞秒激光LASIK手术后角膜生物力学参数有较明显改变,可通过Corvis ST及ORA生物力学参数计算得出相应变化,手术后生物力学参数变化与角膜厚度相关性明显。