This is an extended version of the same titled paper presented at the 21st CIRED. It discusses a new technique for identification and location of defective insulator strings in power lines based on the analysis of hig...This is an extended version of the same titled paper presented at the 21st CIRED. It discusses a new technique for identification and location of defective insulator strings in power lines based on the analysis of high frequency signals generated by corona effect. Damaged insulator strings may lead to loss of insulation and hence to the corona effect, in other words, to partial discharges. These partial discharges can be detected by a system composed of a capacitive coupling device (region between the phase and the metal body of a current transformer), a data acquisition board and a computer. Analyzing the waveform of these partial discharges through a neural network based software, it is possible to identify and locate the defective insulator string. This paper discusses how this software analysis works and why its technique is suitable for this application. Hence the results of key tests performed along the development are discussed, pointing out the main factors that affect their performance.展开更多
Conductor corona performance is significant in the evaluation of electromagnetic environment for high voltage power transmission lines. The influence of artificial contaminated conductors on corona discharge was studi...Conductor corona performance is significant in the evaluation of electromagnetic environment for high voltage power transmission lines. The influence of artificial contaminated conductors on corona discharge was studied and turned out to be complicated. The ionized field strength on the corona cage was measured by field mill. Meanwhile, photos of corona plumes were photographed and grayed to quantitate the corona discharge intensity. Subsequently, a calculation model for equivalent electric field strength coefficient was established to evaluate the discharge intensity of conductors in coaxial cylindrical electrode. It could be found the computational results achieved an agreement with the observed experimental phenomena. By means of simulation results, a reasonable explanation was given to the finding that the closer the distance between the two protrusions was, the lower the corona discharge intensity and higher corona inception voltage of the conductors would be. In summary, the distributions of corona sources played an important role in the corona discharge and this work would provide an important reference for the evaluation of corona effects on the surface of contaminated conductors.展开更多
文摘This is an extended version of the same titled paper presented at the 21st CIRED. It discusses a new technique for identification and location of defective insulator strings in power lines based on the analysis of high frequency signals generated by corona effect. Damaged insulator strings may lead to loss of insulation and hence to the corona effect, in other words, to partial discharges. These partial discharges can be detected by a system composed of a capacitive coupling device (region between the phase and the metal body of a current transformer), a data acquisition board and a computer. Analyzing the waveform of these partial discharges through a neural network based software, it is possible to identify and locate the defective insulator string. This paper discusses how this software analysis works and why its technique is suitable for this application. Hence the results of key tests performed along the development are discussed, pointing out the main factors that affect their performance.
基金supported by the National Natural Science Foundation of China(Grant No.51377096)Fok Ying-Tong Education Foundation(Grant No.151058)+1 种基金the Fundamental Research Funds for the Central Universities(Grant No.2016YQ01)Young Elite Scientists Sponsorship Program by China Association for Science and Technology(CAST)
文摘Conductor corona performance is significant in the evaluation of electromagnetic environment for high voltage power transmission lines. The influence of artificial contaminated conductors on corona discharge was studied and turned out to be complicated. The ionized field strength on the corona cage was measured by field mill. Meanwhile, photos of corona plumes were photographed and grayed to quantitate the corona discharge intensity. Subsequently, a calculation model for equivalent electric field strength coefficient was established to evaluate the discharge intensity of conductors in coaxial cylindrical electrode. It could be found the computational results achieved an agreement with the observed experimental phenomena. By means of simulation results, a reasonable explanation was given to the finding that the closer the distance between the two protrusions was, the lower the corona discharge intensity and higher corona inception voltage of the conductors would be. In summary, the distributions of corona sources played an important role in the corona discharge and this work would provide an important reference for the evaluation of corona effects on the surface of contaminated conductors.