In the case of three-layered(air-seawater-seabed)model,the analytical expressions of the static electric and static magnetic field produced by the static electric dipole located in seawater were derived by using the m...In the case of three-layered(air-seawater-seabed)model,the analytical expressions of the static electric and static magnetic field produced by the static electric dipole located in seawater were derived by using the mirror image theory.Combined with the distribution of the underwater electric potential measured in laboratory,an electric dipole model for physical scale of ship was established and the distribution characteristics of an actual ship' s corrosion related magnetic field were obtained.Based on established models,theoretical analysis and calculation were made to catch out the distribution characteristics of static magnetic field related with corrosion and anticorrosion,which can not be measured directly in seawater.The results show that the static magnetic field related with corrosion and anticorrosion is a kind of noteworthy obstacle signal for degaussed ships.展开更多
With the combination of electrochemical corrosion due to stray current in running tunnels of metro, the formula to determine the corrosion products of rebars in reinforced concrete subjected to externally applied dire...With the combination of electrochemical corrosion due to stray current in running tunnels of metro, the formula to determine the corrosion products of rebars in reinforced concrete subjected to externally applied direct current is proposed, and the influence of corrosion on stress in concrete is also discussed. Meanwhile, the concept of corrosion stress field and its mathematical formula are presented in the paper. Finally the failure mode of concrete and its shortest breaking time are also analyzed.展开更多
Carbon nanotube(CNT) cathodes prepared by electrophoretic deposition were treated by a combination of nickel electroplating and cathode corrosion technologies.The characteristics of the samples were measured by scan...Carbon nanotube(CNT) cathodes prepared by electrophoretic deposition were treated by a combination of nickel electroplating and cathode corrosion technologies.The characteristics of the samples were measured by scanning electron microscopy,energy dispersive X-ray spectroscopy,J-E and F-N plots.After the treatment,the CNT cathodes showed improved field emission properties such as turn-on field,threshold electric field,current density,stability and luminescence uniformity.Concretely,the turn-on field decreased from 0.95 to 0.45 V/μm at an emission current density of 1 mA/cm^2,and the threshold electric field decreased from 0.99 to 0.46 V/μm at a current density of 3 mA/cm^2.The maximum current density was up to 7 mA/cm2 at a field of 0.48 V/μm.In addition,the current density of the CNT cathodes fluctuated at around 0.7 mA/cm^2 for 20 h,with an initial current density 0.75 mA/cm^2.The improvement in field emission properties was found to be due to the exposure of more CNT tips,the wider gaps among the CNTs and the infiltration of nickel particles.展开更多
基金Sponsored by National Defense Pre-research Foundation(51444070105JB11)
文摘In the case of three-layered(air-seawater-seabed)model,the analytical expressions of the static electric and static magnetic field produced by the static electric dipole located in seawater were derived by using the mirror image theory.Combined with the distribution of the underwater electric potential measured in laboratory,an electric dipole model for physical scale of ship was established and the distribution characteristics of an actual ship' s corrosion related magnetic field were obtained.Based on established models,theoretical analysis and calculation were made to catch out the distribution characteristics of static magnetic field related with corrosion and anticorrosion,which can not be measured directly in seawater.The results show that the static magnetic field related with corrosion and anticorrosion is a kind of noteworthy obstacle signal for degaussed ships.
文摘With the combination of electrochemical corrosion due to stray current in running tunnels of metro, the formula to determine the corrosion products of rebars in reinforced concrete subjected to externally applied direct current is proposed, and the influence of corrosion on stress in concrete is also discussed. Meanwhile, the concept of corrosion stress field and its mathematical formula are presented in the paper. Finally the failure mode of concrete and its shortest breaking time are also analyzed.
基金Project supported by the National High Technology Research and Development Program of China(No.2008AA03A313)the National Natural Science Foundation of China(No.61106053)the Specialized Research Fund for the Doctoral Program of Higher Education of China(No.20103514110007)
文摘Carbon nanotube(CNT) cathodes prepared by electrophoretic deposition were treated by a combination of nickel electroplating and cathode corrosion technologies.The characteristics of the samples were measured by scanning electron microscopy,energy dispersive X-ray spectroscopy,J-E and F-N plots.After the treatment,the CNT cathodes showed improved field emission properties such as turn-on field,threshold electric field,current density,stability and luminescence uniformity.Concretely,the turn-on field decreased from 0.95 to 0.45 V/μm at an emission current density of 1 mA/cm^2,and the threshold electric field decreased from 0.99 to 0.46 V/μm at a current density of 3 mA/cm^2.The maximum current density was up to 7 mA/cm2 at a field of 0.48 V/μm.In addition,the current density of the CNT cathodes fluctuated at around 0.7 mA/cm^2 for 20 h,with an initial current density 0.75 mA/cm^2.The improvement in field emission properties was found to be due to the exposure of more CNT tips,the wider gaps among the CNTs and the infiltration of nickel particles.