Previous studies in literatures adequately emphasized that inserting fins into phase change material is among the most promising techniques to augment thermal performance of shell-and-tube latent heat thermal energy s...Previous studies in literatures adequately emphasized that inserting fins into phase change material is among the most promising techniques to augment thermal performance of shell-and-tube latent heat thermal energy storage unit.In this study,the novel unequal-length fins are designed from the perspective of synergistic benefits of heat transfer and energy storage performance,and the effects of arrangement,number and total length of unequal-length fins are numerically investigated.Results show that utilization of fins with ascending length,when short and long fins are located in the inlet and outlet of heat transfer fluid respectively,can further promote the heat transfer and energy storage performance compared with equal length fins,and a maximum 6.17%and 0.43%increment of heat transfer performance and stored energy is achieved in full melting time,respectively.The number of unequal-length fins plays a major role in the energy storage,and 18.95%and 0.91%improvement of heat transfer performance and stored energy is realized when equipped with 2 unequal-length fins.A 21.17%improvement of the heat transfer performance is obtained when the total length of unequal-length fins is 18 mm.The present study is helpful to make further efforts to enhance heat transfer and energy storage of shell-and-tube latent heat thermal energy storage unit with unequal-length fins.展开更多
The new type of heat exchanger elements-Ni-based Implanted Spiral FinnedTurbes (NISFT) was studied and tested, which can contribute to increase the efficiency andreliability. The relation of Nu, Eu and Re with differe...The new type of heat exchanger elements-Ni-based Implanted Spiral FinnedTurbes (NISFT) was studied and tested, which can contribute to increase the efficiency andreliability. The relation of Nu, Eu and Re with different fin pitch, fin height, transverse pitchand longitudinal pitch were gained, which constituted the basic foundation for the engineeringapplication of NISFT.展开更多
In this article,a new evaporative condenser with an annular elliptic firmed tube heat exchanger that includes a round inner tube and elliptic outer finned tube was designed and analyzed.The refrigerant flows between t...In this article,a new evaporative condenser with an annular elliptic firmed tube heat exchanger that includes a round inner tube and elliptic outer finned tube was designed and analyzed.The refrigerant flows between the round inner tube and the elliptic outer tube,and it simultaneously exchanges heat with the cooling water in the inner tube,the spray water,and the cooling air flowing past the outer tube.Using field measurement for the traditional round finned tube evaporative condenser in the Futong Metro Station of Line 14 in Beijing,China,the theoretical heat transfer performance of the annular elliptic finned tube evaporative condenser was analyzed and simulated.Compared with a round finned tube heat exchanger,the heat exchange capacity of the annular elliptic finned tube increased by 2.34%to 9.28%;the total heat transfer coefficient increased by 47.42%,and the power consumption of the fan in the air-conditioning system with an annular elliptic finned tube heat exchanger decreased by 11.18%to 14.65%.Therefore,the energy-saving performance and the heat transfer performance of the new annular elliptic finned tube heat exchanger were enhanced compared to the round finned tube heat exchanger.展开更多
基金This investigation was financially supported by the National Science Foundation of China(NSFC)(No.52078110)the Natural Science Foundation of Heilongjiang Province(No.LH2019E015)the Scientific Project of Ministry of Housing and Urban-Rural Development of China(No.2020-K-184,No.2021-K-160).
文摘Previous studies in literatures adequately emphasized that inserting fins into phase change material is among the most promising techniques to augment thermal performance of shell-and-tube latent heat thermal energy storage unit.In this study,the novel unequal-length fins are designed from the perspective of synergistic benefits of heat transfer and energy storage performance,and the effects of arrangement,number and total length of unequal-length fins are numerically investigated.Results show that utilization of fins with ascending length,when short and long fins are located in the inlet and outlet of heat transfer fluid respectively,can further promote the heat transfer and energy storage performance compared with equal length fins,and a maximum 6.17%and 0.43%increment of heat transfer performance and stored energy is achieved in full melting time,respectively.The number of unequal-length fins plays a major role in the energy storage,and 18.95%and 0.91%improvement of heat transfer performance and stored energy is realized when equipped with 2 unequal-length fins.A 21.17%improvement of the heat transfer performance is obtained when the total length of unequal-length fins is 18 mm.The present study is helpful to make further efforts to enhance heat transfer and energy storage of shell-and-tube latent heat thermal energy storage unit with unequal-length fins.
文摘The new type of heat exchanger elements-Ni-based Implanted Spiral FinnedTurbes (NISFT) was studied and tested, which can contribute to increase the efficiency andreliability. The relation of Nu, Eu and Re with different fin pitch, fin height, transverse pitchand longitudinal pitch were gained, which constituted the basic foundation for the engineeringapplication of NISFT.
基金The work was supported by the Natural Science Foundation of Shaanxi Province(No.2018JM5084)“the 13th Five-Year”National Science and Technology Major Project of China(No.2017YFC0702202)+1 种基金the Shaanxi Key Science and Technology Innovative Tea m Project(No.2016KCT-22)the Fundamental Research Funds for the Central Universities(CHD300102289203).
文摘In this article,a new evaporative condenser with an annular elliptic firmed tube heat exchanger that includes a round inner tube and elliptic outer finned tube was designed and analyzed.The refrigerant flows between the round inner tube and the elliptic outer tube,and it simultaneously exchanges heat with the cooling water in the inner tube,the spray water,and the cooling air flowing past the outer tube.Using field measurement for the traditional round finned tube evaporative condenser in the Futong Metro Station of Line 14 in Beijing,China,the theoretical heat transfer performance of the annular elliptic finned tube evaporative condenser was analyzed and simulated.Compared with a round finned tube heat exchanger,the heat exchange capacity of the annular elliptic finned tube increased by 2.34%to 9.28%;the total heat transfer coefficient increased by 47.42%,and the power consumption of the fan in the air-conditioning system with an annular elliptic finned tube heat exchanger decreased by 11.18%to 14.65%.Therefore,the energy-saving performance and the heat transfer performance of the new annular elliptic finned tube heat exchanger were enhanced compared to the round finned tube heat exchanger.