Developing a novel drop counter by introducing the Internet of Things concept has been vigorously conducted in recent years. Understanding the newly introduced drop counter’s flow rate control accuracy and flow rate ...Developing a novel drop counter by introducing the Internet of Things concept has been vigorously conducted in recent years. Understanding the newly introduced drop counter’s flow rate control accuracy and flow rate count feature is essential for improving safety in infusion management. This study aimed to verify if the new drop counters could secure accurate flow rate and drip count by conducting actual flow rate measurements using gravimetry and functional evaluation. A drop counter was attached to each drip chamber of the infusion set, and an IV drip was conducted at the 100 ml/h flow rate. The weight of discharged physiological saline was measured to plot trumpet curves. Next, three different types of drop counters were evaluated to determine if they maintained drip count accuracy according to the changes in their position angles. The flow rate errors in all conditions indicated trumpet-like curves, exhibiting an overall error range within ±10% in all observation windows. Although every drop counter successfully detected and measured dripping, it was challenging in some counters to detect dripping when the drip chamber was tilted. In comparing adult and pediatric IV sets, the adult IV set was found to be less likely to detect dripping in the angled position. No significant differences in results were confirmed between high and low flow rates, suggesting that the drop count function would not be affected by the flow rate in the ranges of typical infusion practices. Doppler sensors have a wide range of measurements and high sensitivity;the dripping was detected successfully even when the drip chamber was tilted, probably due to the advantages of these sensors. In contrast, miscounts occurred in those equipped with infrared sensors, which could not detect light intensity changes in tilted positions. Understanding the tendencies in flow rate errors in infusion can be valuable information for infusion management.展开更多
In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the ...In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the etched tracks from radon alpha particles on this detector are usually counted by means of an optical microscope or a spark counter. An optimal reading of the track densities which must be converted into radon concentrations, can’t be done without a good mastery of the mode of operation and use of these devices. Furthermore, investigations to know as to whether or not each of those can be used to determine radon concentration are necessary. These are the objectives of the present work in which LR 115 samples exposed to radon for at least 3 months, were chemically developed under standard conditions and read. The track densities obtained with the microscope are very much higher than those of the counter for each sample. These results are consistent with those published by other authors. However, each of these devices can be used interchangeably for alpha tracks counting, as both provide radon concentrations with a very good linear correlation coefficient of 0.95 taking into account their respective calibration factors for the reading of this detector. In addition, the saturation phenomenon for the spark counter reading of LR 115 detector occurs beyond 11,000 tr/cm<sup>2</sup>, a density never reached during our environmental radon measurements.展开更多
Taking a propfan engine as the research object,the CFD method was used for 3D modeling and unsteady slip flow for numerical calculation.The propfan rotation domain and the nacelle outside flow domain were meshed by us...Taking a propfan engine as the research object,the CFD method was used for 3D modeling and unsteady slip flow for numerical calculation.The propfan rotation domain and the nacelle outside flow domain were meshed by using the partition splicing grid technology.Used the Reynolds⁃averaged of N⁃S equation,the Reynolds stress term uses the RNG turbulence model;and based on the slip grid method,numerical calculation of the flow field with different Mach numbers,front and rear blade angles and engine state were carried out;and the change law of propeller fan characteristics and the influence of slip flow on the inlet flow field were analyzed.The blade angle was the key parameter of the propeller fan characteristic conditions.When the blade angle increases from 41°to 50°,the thrust coefficient increases by 31.2%,and the power coefficient increases by 33.4%;in the climbing state of the propeller fan,the maximum total pressure distortion at the inlet port of 6.8%;the cross section is less affected by the slip flow of the propfan;and the pressure distribution is relatively uniform,but the area of the flow channel is small.The research results can provide a solution for the matching of the counter⁃rotating propeller fan and the engine and the arrangement of the air inlet measuring rake.展开更多
The influence of filling parameters including pouring temperature, filling speed, boost pressure and synchronous pressure on the fatigue of A357 alloy produced by counter pressure plaster casting was studied. The Tagu...The influence of filling parameters including pouring temperature, filling speed, boost pressure and synchronous pressure on the fatigue of A357 alloy produced by counter pressure plaster casting was studied. The Taguchi method was used to investigate the relationship between the fatigue performance and filling parameters. The results show that filling speed is the most significant factor among the four parameters. Synchronous pressures is less influential on the fatigue life when the value of synchronous pressure is from 400 kPa to 600 kPa.展开更多
Significant progress has been made in the development of non-precious metal electrocatalysts (NPMEs) during the past decade. Correspondingly, there is an urgent demand for an appropriate measurement method to be est...Significant progress has been made in the development of non-precious metal electrocatalysts (NPMEs) during the past decade. Correspondingly, there is an urgent demand for an appropriate measurement method to be established for the reliable evaluation of NPMEs. In this study, platinum and graphite counter electrodes were used to investigate the impact of counter electrode material on the accelerated durability testing (ADT) of NPMEs in acidic medium. Platinum used as the coun- ter electrode in a traditional three-electrode electrochemical cell was found to dissolve in acidic medium and re-deposit on NPME coated on the working electrode during ADT. Such re-deposition causes the oxygen reduction reaction (ORR) performance of NPMEs to remarkably improve, and thus will seriously mislead our judgment of NPMEs if we are unaware of it. The phenomenon can be avoided using a graphite counter electrode.展开更多
文章通过对Counting Online Usage of Networked Electronic Resources Codes of Practice(COUNTER)项目的成立背景、组织成员、日常管理、业务的介绍以及其成功因素的分析,认为我国也亟需加强对数字期刊及其他资源利用情况的统计,并提...文章通过对Counting Online Usage of Networked Electronic Resources Codes of Practice(COUNTER)项目的成立背景、组织成员、日常管理、业务的介绍以及其成功因素的分析,认为我国也亟需加强对数字期刊及其他资源利用情况的统计,并提出了相关建议。展开更多
提出了一种基于双层Counter Bloom Filter的长流识别算法(algorithm based on double counter bloom filter for long flows identification,简称CCBF).该算法使用两层Counter Bloom Filter结构,将长流过滤和长流存在分开处理.分析了该...提出了一种基于双层Counter Bloom Filter的长流识别算法(algorithm based on double counter bloom filter for long flows identification,简称CCBF).该算法使用两层Counter Bloom Filter结构,将长流过滤和长流存在分开处理.分析了该算法的误判率,通过模拟数据分析了算法错误率和内存资源限制的关系,并在相同内存资源限制的条件下,将该算法与类似算法的准确性进行了比较.结果表明,在数据量较大的情况下,该算法具有比现有算法更小的平均错误率;对算法的时间效率分析表明,该算法可以达到1500kpps的处理速度.各项指标反映出,该算法可以应用于大规模主干网的长流监测.展开更多
文摘Developing a novel drop counter by introducing the Internet of Things concept has been vigorously conducted in recent years. Understanding the newly introduced drop counter’s flow rate control accuracy and flow rate count feature is essential for improving safety in infusion management. This study aimed to verify if the new drop counters could secure accurate flow rate and drip count by conducting actual flow rate measurements using gravimetry and functional evaluation. A drop counter was attached to each drip chamber of the infusion set, and an IV drip was conducted at the 100 ml/h flow rate. The weight of discharged physiological saline was measured to plot trumpet curves. Next, three different types of drop counters were evaluated to determine if they maintained drip count accuracy according to the changes in their position angles. The flow rate errors in all conditions indicated trumpet-like curves, exhibiting an overall error range within ±10% in all observation windows. Although every drop counter successfully detected and measured dripping, it was challenging in some counters to detect dripping when the drip chamber was tilted. In comparing adult and pediatric IV sets, the adult IV set was found to be less likely to detect dripping in the angled position. No significant differences in results were confirmed between high and low flow rates, suggesting that the drop count function would not be affected by the flow rate in the ranges of typical infusion practices. Doppler sensors have a wide range of measurements and high sensitivity;the dripping was detected successfully even when the drip chamber was tilted, probably due to the advantages of these sensors. In contrast, miscounts occurred in those equipped with infrared sensors, which could not detect light intensity changes in tilted positions. Understanding the tendencies in flow rate errors in infusion can be valuable information for infusion management.
文摘In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the etched tracks from radon alpha particles on this detector are usually counted by means of an optical microscope or a spark counter. An optimal reading of the track densities which must be converted into radon concentrations, can’t be done without a good mastery of the mode of operation and use of these devices. Furthermore, investigations to know as to whether or not each of those can be used to determine radon concentration are necessary. These are the objectives of the present work in which LR 115 samples exposed to radon for at least 3 months, were chemically developed under standard conditions and read. The track densities obtained with the microscope are very much higher than those of the counter for each sample. These results are consistent with those published by other authors. However, each of these devices can be used interchangeably for alpha tracks counting, as both provide radon concentrations with a very good linear correlation coefficient of 0.95 taking into account their respective calibration factors for the reading of this detector. In addition, the saturation phenomenon for the spark counter reading of LR 115 detector occurs beyond 11,000 tr/cm<sup>2</sup>, a density never reached during our environmental radon measurements.
文摘Taking a propfan engine as the research object,the CFD method was used for 3D modeling and unsteady slip flow for numerical calculation.The propfan rotation domain and the nacelle outside flow domain were meshed by using the partition splicing grid technology.Used the Reynolds⁃averaged of N⁃S equation,the Reynolds stress term uses the RNG turbulence model;and based on the slip grid method,numerical calculation of the flow field with different Mach numbers,front and rear blade angles and engine state were carried out;and the change law of propeller fan characteristics and the influence of slip flow on the inlet flow field were analyzed.The blade angle was the key parameter of the propeller fan characteristic conditions.When the blade angle increases from 41°to 50°,the thrust coefficient increases by 31.2%,and the power coefficient increases by 33.4%;in the climbing state of the propeller fan,the maximum total pressure distortion at the inlet port of 6.8%;the cross section is less affected by the slip flow of the propfan;and the pressure distribution is relatively uniform,but the area of the flow channel is small.The research results can provide a solution for the matching of the counter⁃rotating propeller fan and the engine and the arrangement of the air inlet measuring rake.
文摘The influence of filling parameters including pouring temperature, filling speed, boost pressure and synchronous pressure on the fatigue of A357 alloy produced by counter pressure plaster casting was studied. The Taguchi method was used to investigate the relationship between the fatigue performance and filling parameters. The results show that filling speed is the most significant factor among the four parameters. Synchronous pressures is less influential on the fatigue life when the value of synchronous pressure is from 400 kPa to 600 kPa.
基金supported by the Fundamental Research Funds for the Central Universities(DUT15RC(3)001,DUT15ZD225)the Program for Liao-ning Excellent Talents in University(LR2015014)+1 种基金the Liaoning BaiQianWan Talents Program(201519)Dalian Excellent Young Scientific and Technological Talents(2015R006)
文摘Significant progress has been made in the development of non-precious metal electrocatalysts (NPMEs) during the past decade. Correspondingly, there is an urgent demand for an appropriate measurement method to be established for the reliable evaluation of NPMEs. In this study, platinum and graphite counter electrodes were used to investigate the impact of counter electrode material on the accelerated durability testing (ADT) of NPMEs in acidic medium. Platinum used as the coun- ter electrode in a traditional three-electrode electrochemical cell was found to dissolve in acidic medium and re-deposit on NPME coated on the working electrode during ADT. Such re-deposition causes the oxygen reduction reaction (ORR) performance of NPMEs to remarkably improve, and thus will seriously mislead our judgment of NPMEs if we are unaware of it. The phenomenon can be avoided using a graphite counter electrode.
文摘文章通过对Counting Online Usage of Networked Electronic Resources Codes of Practice(COUNTER)项目的成立背景、组织成员、日常管理、业务的介绍以及其成功因素的分析,认为我国也亟需加强对数字期刊及其他资源利用情况的统计,并提出了相关建议。
文摘提出了一种基于双层Counter Bloom Filter的长流识别算法(algorithm based on double counter bloom filter for long flows identification,简称CCBF).该算法使用两层Counter Bloom Filter结构,将长流过滤和长流存在分开处理.分析了该算法的误判率,通过模拟数据分析了算法错误率和内存资源限制的关系,并在相同内存资源限制的条件下,将该算法与类似算法的准确性进行了比较.结果表明,在数据量较大的情况下,该算法具有比现有算法更小的平均错误率;对算法的时间效率分析表明,该算法可以达到1500kpps的处理速度.各项指标反映出,该算法可以应用于大规模主干网的长流监测.