Counter gravity casting equipments(CGCE) were widely used to produce large thin-walled A357 aluminum alloy components. To improve the pressure control precision of CGCE to get high quality castings, a pressure control...Counter gravity casting equipments(CGCE) were widely used to produce large thin-walled A357 aluminum alloy components. To improve the pressure control precision of CGCE to get high quality castings, a pressure control system based on fuzzy-PID hybrid control technology and the digital assembled valve was developed. The actual pressure tracking experiment results show that the special system by applying PID controller and fuzzy controller to varied phases, is not only able to inherit the small error and good static stability of classical PID control, but also has fuzzy control’s advantage of fully adapting itself to the object. The pressure control error is less than 0.3 kPa. By using this pressure control system, large complex thin-walled A357 aluminum alloy castings with high quality was successfully produced.展开更多
Coptis chinensis Franch, a widely used Traditional Chinese Medicine, shows various kinds of bioactivity. The major active components of the herb are considered to be alkaloids. Thus, preparative separation of these al...Coptis chinensis Franch, a widely used Traditional Chinese Medicine, shows various kinds of bioactivity. The major active components of the herb are considered to be alkaloids. Thus, preparative separation of these alkaloids is critical important for further pharmacology and mechanism studies. In the paper, five alkaloids from C. chinensis were purified by HSCCC using the solvent system composed of chloro-form-metha- nol-water (2:1:1, v/v/v) single prepared. The content of each solvent in solvent system were determined by gas chromatography (GC), then according the ratios of solvents in each phase to prepare the mobile and stationary phase respectively. And a comparative study was carried out between together preparation and single preparation of the solvent system. The purities and recoveries of all the products were over 98.5% and 92%. However, 134 mL chloroform, 336 mL methanol and 452 mL water were saved when the two phase were singled by GC. Our research showed an economical method for separating alkaloids from C. chinensis by HSCCC using the solvent system single prepared by GC.展开更多
Developing a novel drop counter by introducing the Internet of Things concept has been vigorously conducted in recent years. Understanding the newly introduced drop counter’s flow rate control accuracy and flow rate ...Developing a novel drop counter by introducing the Internet of Things concept has been vigorously conducted in recent years. Understanding the newly introduced drop counter’s flow rate control accuracy and flow rate count feature is essential for improving safety in infusion management. This study aimed to verify if the new drop counters could secure accurate flow rate and drip count by conducting actual flow rate measurements using gravimetry and functional evaluation. A drop counter was attached to each drip chamber of the infusion set, and an IV drip was conducted at the 100 ml/h flow rate. The weight of discharged physiological saline was measured to plot trumpet curves. Next, three different types of drop counters were evaluated to determine if they maintained drip count accuracy according to the changes in their position angles. The flow rate errors in all conditions indicated trumpet-like curves, exhibiting an overall error range within ±10% in all observation windows. Although every drop counter successfully detected and measured dripping, it was challenging in some counters to detect dripping when the drip chamber was tilted. In comparing adult and pediatric IV sets, the adult IV set was found to be less likely to detect dripping in the angled position. No significant differences in results were confirmed between high and low flow rates, suggesting that the drop count function would not be affected by the flow rate in the ranges of typical infusion practices. Doppler sensors have a wide range of measurements and high sensitivity;the dripping was detected successfully even when the drip chamber was tilted, probably due to the advantages of these sensors. In contrast, miscounts occurred in those equipped with infrared sensors, which could not detect light intensity changes in tilted positions. Understanding the tendencies in flow rate errors in infusion can be valuable information for infusion management.展开更多
The influence of filling parameters including pouring temperature, filling speed, boost pressure and synchronous pressure on the fatigue of A357 alloy produced by counter pressure plaster casting was studied. The Tagu...The influence of filling parameters including pouring temperature, filling speed, boost pressure and synchronous pressure on the fatigue of A357 alloy produced by counter pressure plaster casting was studied. The Taguchi method was used to investigate the relationship between the fatigue performance and filling parameters. The results show that filling speed is the most significant factor among the four parameters. Synchronous pressures is less influential on the fatigue life when the value of synchronous pressure is from 400 kPa to 600 kPa.展开更多
Significant progress has been made in the development of non-precious metal electrocatalysts (NPMEs) during the past decade. Correspondingly, there is an urgent demand for an appropriate measurement method to be est...Significant progress has been made in the development of non-precious metal electrocatalysts (NPMEs) during the past decade. Correspondingly, there is an urgent demand for an appropriate measurement method to be established for the reliable evaluation of NPMEs. In this study, platinum and graphite counter electrodes were used to investigate the impact of counter electrode material on the accelerated durability testing (ADT) of NPMEs in acidic medium. Platinum used as the coun- ter electrode in a traditional three-electrode electrochemical cell was found to dissolve in acidic medium and re-deposit on NPME coated on the working electrode during ADT. Such re-deposition causes the oxygen reduction reaction (ORR) performance of NPMEs to remarkably improve, and thus will seriously mislead our judgment of NPMEs if we are unaware of it. The phenomenon can be avoided using a graphite counter electrode.展开更多
文章通过对Counting Online Usage of Networked Electronic Resources Codes of Practice(COUNTER)项目的成立背景、组织成员、日常管理、业务的介绍以及其成功因素的分析,认为我国也亟需加强对数字期刊及其他资源利用情况的统计,并提...文章通过对Counting Online Usage of Networked Electronic Resources Codes of Practice(COUNTER)项目的成立背景、组织成员、日常管理、业务的介绍以及其成功因素的分析,认为我国也亟需加强对数字期刊及其他资源利用情况的统计,并提出了相关建议。展开更多
AIM: To evaluate the accuracy of automated blood cell counters for ascitic polymorphonuclear (PMN) determination for: (1) diagnosis, (2) efficacy of the ongoing antibiotic therapy, and (3) resolution of spon...AIM: To evaluate the accuracy of automated blood cell counters for ascitic polymorphonuclear (PMN) determination for: (1) diagnosis, (2) efficacy of the ongoing antibiotic therapy, and (3) resolution of spontaneous bacterial peritonitis (SBP). METHODS: One hundred and twelve ascitic fluid samples were collected from 52 consecutive cirrhotic patients, 16 of them with SBP. The agreement between the manual and the automated method for PMN count was assessed. The sensitivity/specificity and the positive/negative predictive value of the automated blood cell counter were also calculated by considering the manual method as the "gold standard" RESULTS: The mean + SD of the difference between manual and automated measurements was 7.8 4- 58 cells/ram3, while the limits of agreement were +124 cells/mm3 [95% confidence interval (CI): +145 to +103] and -108 cells/mm3 (95% CI: -87 to -129). The automated cell counter had a sensitivity of 100% and a specificity of 97.7% in diagnosing SBP, and a sensitivity of 91% and a specificity of 100% for the efficacy of the ongoing antibiotic therapy. The two methods showed a complete agreement for the resolution of infection. CONCLUSION: Automated cell counters not only have a good diagnostic accuracy, but are also very effectivein monitoring the antibiotic treatment in patients with SBP. Because of their quicker performance, they should replace the manual counting for PMN determination in the ascitic fluid of patients with SBP.展开更多
基金Project(2006CB605202) supported by the Basic Research Development Program of China
文摘Counter gravity casting equipments(CGCE) were widely used to produce large thin-walled A357 aluminum alloy components. To improve the pressure control precision of CGCE to get high quality castings, a pressure control system based on fuzzy-PID hybrid control technology and the digital assembled valve was developed. The actual pressure tracking experiment results show that the special system by applying PID controller and fuzzy controller to varied phases, is not only able to inherit the small error and good static stability of classical PID control, but also has fuzzy control’s advantage of fully adapting itself to the object. The pressure control error is less than 0.3 kPa. By using this pressure control system, large complex thin-walled A357 aluminum alloy castings with high quality was successfully produced.
文摘Coptis chinensis Franch, a widely used Traditional Chinese Medicine, shows various kinds of bioactivity. The major active components of the herb are considered to be alkaloids. Thus, preparative separation of these alkaloids is critical important for further pharmacology and mechanism studies. In the paper, five alkaloids from C. chinensis were purified by HSCCC using the solvent system composed of chloro-form-metha- nol-water (2:1:1, v/v/v) single prepared. The content of each solvent in solvent system were determined by gas chromatography (GC), then according the ratios of solvents in each phase to prepare the mobile and stationary phase respectively. And a comparative study was carried out between together preparation and single preparation of the solvent system. The purities and recoveries of all the products were over 98.5% and 92%. However, 134 mL chloroform, 336 mL methanol and 452 mL water were saved when the two phase were singled by GC. Our research showed an economical method for separating alkaloids from C. chinensis by HSCCC using the solvent system single prepared by GC.
文摘Developing a novel drop counter by introducing the Internet of Things concept has been vigorously conducted in recent years. Understanding the newly introduced drop counter’s flow rate control accuracy and flow rate count feature is essential for improving safety in infusion management. This study aimed to verify if the new drop counters could secure accurate flow rate and drip count by conducting actual flow rate measurements using gravimetry and functional evaluation. A drop counter was attached to each drip chamber of the infusion set, and an IV drip was conducted at the 100 ml/h flow rate. The weight of discharged physiological saline was measured to plot trumpet curves. Next, three different types of drop counters were evaluated to determine if they maintained drip count accuracy according to the changes in their position angles. The flow rate errors in all conditions indicated trumpet-like curves, exhibiting an overall error range within ±10% in all observation windows. Although every drop counter successfully detected and measured dripping, it was challenging in some counters to detect dripping when the drip chamber was tilted. In comparing adult and pediatric IV sets, the adult IV set was found to be less likely to detect dripping in the angled position. No significant differences in results were confirmed between high and low flow rates, suggesting that the drop count function would not be affected by the flow rate in the ranges of typical infusion practices. Doppler sensors have a wide range of measurements and high sensitivity;the dripping was detected successfully even when the drip chamber was tilted, probably due to the advantages of these sensors. In contrast, miscounts occurred in those equipped with infrared sensors, which could not detect light intensity changes in tilted positions. Understanding the tendencies in flow rate errors in infusion can be valuable information for infusion management.
文摘The influence of filling parameters including pouring temperature, filling speed, boost pressure and synchronous pressure on the fatigue of A357 alloy produced by counter pressure plaster casting was studied. The Taguchi method was used to investigate the relationship between the fatigue performance and filling parameters. The results show that filling speed is the most significant factor among the four parameters. Synchronous pressures is less influential on the fatigue life when the value of synchronous pressure is from 400 kPa to 600 kPa.
基金supported by the Fundamental Research Funds for the Central Universities(DUT15RC(3)001,DUT15ZD225)the Program for Liao-ning Excellent Talents in University(LR2015014)+1 种基金the Liaoning BaiQianWan Talents Program(201519)Dalian Excellent Young Scientific and Technological Talents(2015R006)
文摘Significant progress has been made in the development of non-precious metal electrocatalysts (NPMEs) during the past decade. Correspondingly, there is an urgent demand for an appropriate measurement method to be established for the reliable evaluation of NPMEs. In this study, platinum and graphite counter electrodes were used to investigate the impact of counter electrode material on the accelerated durability testing (ADT) of NPMEs in acidic medium. Platinum used as the coun- ter electrode in a traditional three-electrode electrochemical cell was found to dissolve in acidic medium and re-deposit on NPME coated on the working electrode during ADT. Such re-deposition causes the oxygen reduction reaction (ORR) performance of NPMEs to remarkably improve, and thus will seriously mislead our judgment of NPMEs if we are unaware of it. The phenomenon can be avoided using a graphite counter electrode.
文摘文章通过对Counting Online Usage of Networked Electronic Resources Codes of Practice(COUNTER)项目的成立背景、组织成员、日常管理、业务的介绍以及其成功因素的分析,认为我国也亟需加强对数字期刊及其他资源利用情况的统计,并提出了相关建议。
文摘AIM: To evaluate the accuracy of automated blood cell counters for ascitic polymorphonuclear (PMN) determination for: (1) diagnosis, (2) efficacy of the ongoing antibiotic therapy, and (3) resolution of spontaneous bacterial peritonitis (SBP). METHODS: One hundred and twelve ascitic fluid samples were collected from 52 consecutive cirrhotic patients, 16 of them with SBP. The agreement between the manual and the automated method for PMN count was assessed. The sensitivity/specificity and the positive/negative predictive value of the automated blood cell counter were also calculated by considering the manual method as the "gold standard" RESULTS: The mean + SD of the difference between manual and automated measurements was 7.8 4- 58 cells/ram3, while the limits of agreement were +124 cells/mm3 [95% confidence interval (CI): +145 to +103] and -108 cells/mm3 (95% CI: -87 to -129). The automated cell counter had a sensitivity of 100% and a specificity of 97.7% in diagnosing SBP, and a sensitivity of 91% and a specificity of 100% for the efficacy of the ongoing antibiotic therapy. The two methods showed a complete agreement for the resolution of infection. CONCLUSION: Automated cell counters not only have a good diagnostic accuracy, but are also very effectivein monitoring the antibiotic treatment in patients with SBP. Because of their quicker performance, they should replace the manual counting for PMN determination in the ascitic fluid of patients with SBP.