期刊文献+
共找到12,657篇文章
< 1 2 250 >
每页显示 20 50 100
Traction power systems for electrified railways:evolution,state of the art,and future trends 被引量:1
1
作者 Haitao Hu Yunjiang Liu +4 位作者 Yong Li Zhengyou He Shibin Gao Xiaojuan Zhu Haidong Tao 《Railway Engineering Science》 EI 2024年第1期1-19,共19页
Traction power systems(TPSs)play a vital role in the operation of electrified railways.The transformation of conventional railway TPSs to novel structures is not only a trend to promote the development of electrified ... Traction power systems(TPSs)play a vital role in the operation of electrified railways.The transformation of conventional railway TPSs to novel structures is not only a trend to promote the development of electrified railways toward high-efficiency and resilience but also an inevitable requirement to achieve carbon neutrality target.On the basis of sorting out the power supply structures of conventional AC and DC modes,this paper first reviews the characteristics of the existing TPSs,such as weak power supply flexibility and low-energy efficiency.Furthermore,the power supply structures of various TPSs for future electrified railways are described in detail,which satisfy longer distance,low-carbon,high-efficiency,high-reliability and high-quality power supply requirements.Meanwhile,the application prospects of different traction modes are discussed from both technical and economic aspects.Eventually,this paper introduces the research progress of mixed-system electrified railways and traction power supply technologies without catenary system,speculates on the future development trends and challenges of TPSs and predicts that TPSs will be based on the continuous power supply mode,employing power electronic equipment and intelligent information technology to construct a railway comprehensive energy system with renewable energy. 展开更多
关键词 Railway traction power system Future electrified railway Flexible continuous power supply Renewable energy Integrated energy system
下载PDF
Pars plana vitrectomy with internal limiting membrane plugging assisted by autologous blood for optic disc pit associated with vitreomacular traction
2
作者 Bin Chen Yan-Ting Li +2 位作者 Tian-Hong Wu Ya-Ping Yuan Yun-Feng Lu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第10期1957-1959,共3页
Dear Editor,We report a case of optic disc pit(ODP)associated with vitreomacular traction which has been successfully treated by a combined technique.We have obtained the written informed consent from the patient,and ... Dear Editor,We report a case of optic disc pit(ODP)associated with vitreomacular traction which has been successfully treated by a combined technique.We have obtained the written informed consent from the patient,and this case study is in accordance with the tenets of the Declaration of Helsinki. 展开更多
关键词 technique. traction MACULAR
下载PDF
Research on the longitudinal protection of a through-type cophase traction direct power supply system based on the empirical wavelet transform
3
作者 Lu Li Zeduan Zhang +5 位作者 Wang Cai Qikang Zhuang Guihong Bi Jian Deng Shilong Chen Xiaorui Kan 《Global Energy Interconnection》 EI CSCD 2024年第2期206-216,共11页
This paper proposes a longitudinal protection scheme utilizing empirical wavelet transform(EWT)for a through-type cophase traction direct power supply system,where both sides of a traction network line exhibit a disti... This paper proposes a longitudinal protection scheme utilizing empirical wavelet transform(EWT)for a through-type cophase traction direct power supply system,where both sides of a traction network line exhibit a distinctive boundary structure.This approach capitalizes on the boundary’s capacity to attenuate the high-frequency component of fault signals,resulting in a variation in the high-frequency transient energy ratio when faults occur inside or outside the line.During internal line faults,the high-frequency transient energy at the checkpoints located at both ends surpasses that of its neighboring lines.Conversely,for faults external to the line,the energy is lower compared to adjacent lines.EWT is employed to decompose the collected fault current signals,allowing access to the high-frequency transient energy.The longitudinal protection for the traction network line is established based on disparities between both ends of the traction network line and the high-frequency transient energy on either side of the boundary.Moreover,simulation verification through experimental results demonstrates the effectiveness of the proposed protection scheme across various initial fault angles,distances to faults,and fault transition resistances. 展开更多
关键词 Through-type Cophase traction direct power supply system traction network Empirical wavelet transform(EWT) Longitudinal protection
下载PDF
Laparoscopic Orchidopexy after 4 Weeks of Testicular Traction with Preservation of Blood Supply: A New Concept for the Treatment of Intra-Abdominal Cryptorchidism: Original Article
4
作者 Ntsobe Tobie Eric Haijin Liu +5 位作者 Nyanit Bob Dorcas Wei Peng Feng Chen Ndikontar Raymond Kouna Tsala Irene Nadine Qian Liu 《Open Journal of Pediatrics》 2024年第2期205-217,共13页
Background: Testicular atrophy is recurrent after orchidopexy for intra-abdominal cryptorchidism due to damage to vessels. Fowlers-Stephens and Shehata methods proposed staged orchidopexy, but are still associated to ... Background: Testicular atrophy is recurrent after orchidopexy for intra-abdominal cryptorchidism due to damage to vessels. Fowlers-Stephens and Shehata methods proposed staged orchidopexy, but are still associated to a rate of atrophy greater than 10%. Purpose: We set out to present a new technique that preserves testicular vessels. Our study is aimed at investigating testicular vitality after surgery. Patients and Method: We reviewed files of boys who underwent orchidopexy for 2 years in our department. Those who have been operated for intra-abdominal cryptorchidism with the new technique and aged between 6 months and 14 years old were included in our study. We excluded boys who have been operated before 6 months and after 14 years old and those who did not respect their follow-up plane. Ultrasound (US) outcomes were used to measure testicular volumes and blood flow at each postoperative visit. The Sample population was divided into group A and group B representing testes that were followed respectively for 12 and 24 months. Results: 22 boys with 25 testes were included in our study;11 testes in group A and 14 testes in group B. In each group, we noted a significant difference of UDT volumes from the third month after surgery with respective P-values 0.05. There was no statistical difference between UDT and contra lateral testes volumes 12 months after surgery in group A and 24 months in group B with respective P-values of 0.07 and 0.72. All volume differential indexes were Conclusion: This method offers a new perspective in performing safe orchidopexy for intra abdominal undescended testes. 展开更多
关键词 LAPAROSCOPY Staged-Orchidopexy Testicar traction Testicular Atrophy
下载PDF
A Loss-model-based Efficiency Optimization Control Method for Induction Traction System of High-speed Train under Emergency Self-propelled Mode
5
作者 Yutong Zhu Yaohua Li 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期227-239,共13页
Increasing attention has been paid to the efficiency improvement of the induction traction system of high-speed trains due to the high demand for energy saving. In emergency self-propelled mode, however, the dc-link v... Increasing attention has been paid to the efficiency improvement of the induction traction system of high-speed trains due to the high demand for energy saving. In emergency self-propelled mode, however, the dc-link voltage and the traction power of the motor are significantly reduced, resulting in decreased traction efficiency due to the low load and low speed operations. Aiming to tackle this problem, a novel efficiency improved control method is introduced to the emergency mode of high-speed train traction system in this paper. In the proposed method, a total loss model of induction motor considering the behaviors of both iron and copper loss is established. An improved iterative algorithm with decreased computational burden is then introduced, resulting in a fast solving of the optimal flux reference for loss minimization at each control period. In addition, considering the parameter variation problem due to the low load and low speed operations, a parameter estimation method is integrated to improve the controller's robustness. The effectiveness of the proposed method on efficiency improvement at low voltage and low load conditions is demonstrated by simulated and experimental results. 展开更多
关键词 Efficiency optimization Induction motor Loss model control Motor drives traction system
下载PDF
Generalized autoencoder-based fault detection method for traction systems with performance degradation
6
作者 Chao Cheng Wenyu Liu +1 位作者 Lu Di Shenquan Wang 《High-Speed Railway》 2024年第3期180-186,共7页
Fault diagnosis of traction systems is important for the safety operation of high-speed trains.Long-term operation of the trains will degrade the performance of systems,which decreases the fault detection accuracy.To ... Fault diagnosis of traction systems is important for the safety operation of high-speed trains.Long-term operation of the trains will degrade the performance of systems,which decreases the fault detection accuracy.To solve this problem,this paper proposes a fault detection method developed by a Generalized Autoencoder(GAE)for systems with performance degradation.The advantage of this method is that it can accurately detect faults when the traction system of high-speed trains is affected by performance degradation.Regardless of the probability distribution,it can handle any data,and the GAE has extremely high sensitivity in anomaly detection.Finally,the effectiveness of this method is verified through the Traction Drive Control System(TDCS)platform.At different performance degradation levels,our method’s experimental results are superior to traditional methods. 展开更多
关键词 Performance degradation Generalized autoencoder Fault detection traction control systems High-speed trains
下载PDF
Effect of endoscopic full-thickness resection assisted by distal serosal turnover with floss traction for gastric submucosal masses
7
作者 Tian-Wen Liu Xiao-Feng Lin +3 位作者 Shu-Ting Wen Jing-Yi Xu Zhao-Li Fu Shu-Min Qin 《World Journal of Clinical Cases》 SCIE 2024年第16期2738-2744,共7页
BACKGROUND Complex and high-risk surgical complications pose pressing challenges in the clinical implementation and advancement of endoscopic full-thickness resection(EFTR).Successful perforation repair under endoscop... BACKGROUND Complex and high-risk surgical complications pose pressing challenges in the clinical implementation and advancement of endoscopic full-thickness resection(EFTR).Successful perforation repair under endoscopy,thereby avoiding surgical intervention and postoperative complications such as peritonitis,are pivotal for effective EFTR.AIM To investigate the effectiveness and safety of EFTR assisted by distal serosal inversion under floss traction in gastric submucosal tumors.METHODS A retrospective analysis of patients with gastric and duodenal submucosal tumors treated with EFTR assisted by the distal serosa inversion under dental floss traction from January 2023 to January 2024 was conducted.The total operation time,tumor dissection time,wound closure time,intraoperative bleeding volume,length of hospital stay and incidence of complications were analyzed.RESULTS There were 93 patients,aged 55.1±12.1 years.Complete tumor resection was achieved in all cases,resulting in a 100% success rate.The average total operation time was 67.4±27.0 min,with tumor dissection taking 43.6±20.4 min.Wound closure times varied,with gastric body closure time of 24.5±14.1 min and gastric fundus closure time of 16.6±8.7 min,showing a significant difference(P<0.05).Intraoperative blood loss was 2.3±4.0 mL,and average length of hospital stay was 5.7±1.9 d.There was no secondary perforation after suturing in all cases.The incidence of delayed bleeding was 2.2%,and the incidence of abdominal infection was 3.2%.No patient required other surgical intervention during and after the operation.CONCLUSION Distal serosal inversion under dental-floss-assisted EFTR significantly reduced wound closure time and intraoperative blood loss,making it a viable approach for gastric submucosal tumors. 展开更多
关键词 Endoscopic full-thickness resection Serosa inversion Dental floss traction Gastric submucosal tumor Auxiliary technology
下载PDF
Lasting Attraction
8
作者 XIA YUANYUAN 《ChinAfrica》 2024年第4期22-24,共3页
High-level opening up and policies to attract foreign direct investment(FDI)were hot topics during the annual sessions of the National People’s Congress(NPC)and the Chinese People’s Political Consultative Conference... High-level opening up and policies to attract foreign direct investment(FDI)were hot topics during the annual sessions of the National People’s Congress(NPC)and the Chinese People’s Political Consultative Conference(CPPCC)National Committee,China’s key annual political meetings commonly known as Two Sessions. 展开更多
关键词 INVESTMENT traction POLITICAL
下载PDF
Microstructure and properties of vacuum counter-pressure cast aluminum alloy 被引量:5
9
作者 YAN Qing-song YU Huan +3 位作者 WEI Bo-kang XU Zhi-feng CAI Chang-chun WAN Hong 《China Foundry》 SCIE CAS 2006年第2期113-116,共4页
The microstructure and properties of vacuum counter-pressure cast aluminum alloy were studied. Results indicated that under the condition of vacuum counter-pressure, liquid melts fill mould cavity under the vacuum and... The microstructure and properties of vacuum counter-pressure cast aluminum alloy were studied. Results indicated that under the condition of vacuum counter-pressure, liquid melts fill mould cavity under the vacuum and crystallize under high pressure which have very good effect on nucleation and solidification feeding. Compared with gravity casting, the microstructure of vacuum counter-pressure cast aluminum alloy is much finer and more uniformly distributed. Mechanical properties of vacuum counter-pressure cast aluminum alloy are improved significantly. 展开更多
关键词 VACUUM counter-pressure CASTING ALUMINUM ALLOY MICROSTRUCTURE properties
下载PDF
Effect of synergistic action of ultrasonic vibration and solidification pressure on tensile properties of vacuum counter-pressure casting aluminum alloy 被引量:5
10
作者 Qing-song Yan Gang Lu +2 位作者 Gui-ming Luo Bo-wen Xiong Qiang-qiang Zheng 《China Foundry》 SCIE 2018年第6期411-417,共7页
The effect of synergistic action of ultrasonic vibration and solidification pressure on tensile properties of vacuum counter-pressure casting ZL114 A alloys was studied systemically through testing and analyzing the t... The effect of synergistic action of ultrasonic vibration and solidification pressure on tensile properties of vacuum counter-pressure casting ZL114 A alloys was studied systemically through testing and analyzing the tensile strength and elongation subjected to different ultrasonic powers and solidification pressures. The results indicate that the synergistic action of ultrasonic vibration and solidification pressure can result in the refinement of grains and improvement of tensile properties. Both the highest tensile strength and elongation of aluminum alloy were obtained under synergistic action of 600 W ultrasonic power and 350 kPa solidification pressure. Moreover, the tensile fracture morphology shows obvious ductile fracture characteristics. When the solidification pressure is lower than 300 kPa, the effect of ultrasonic power on tensile strength and elongation is more obvious, but when the solidification pressure is higher than 300 kPa, the effect of solidification pressure on tensile strength and elongation is greater. Meanwhile, the size and morphology of the eutectic silicon were improved significantly by the ultrasonic vibration and pressurized solidification. The strip and massive eutectic silicon phase are completely converted into small short rod-like and evenly distributed Si phases at the grain boundary of primary α-Al. 展开更多
关键词 ULTRASONIC power SOLIDIFICATION pressure VACUUM counter-pressure CASTING aluminum alloy TENSILE property
下载PDF
Effect of Solidification Condition on Secondary Dendrite Arm Spacing of the A357 Alloy under Counter-pressure Casting 被引量:3
11
作者 米国发 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2009年第1期119-122,共4页
The effect of counter-pressure casting parameters on secondary dendrite arm spacing (SDAS) of A357 alloy under different process parameters was studied. Quartz sand mould with chill can strongly decrease the SDAS. R... The effect of counter-pressure casting parameters on secondary dendrite arm spacing (SDAS) of A357 alloy under different process parameters was studied. Quartz sand mould with chill can strongly decrease the SDAS. Reduced SDAS close to the mould bottom because of chilling was obtained. Pressure seems to have no apparent effect on the SDAS. In order to obtain casts with UTS ≥320 MPa, SDAS must be less than 55 μm, which means a local cooling rate VL≥0.23 ℃ /s. 展开更多
关键词 counter-pressure casting SDAS A357 alloy
下载PDF
Density and solidification feeding model of vacuum counter-pressure cast aluminum alloy under grade-pressuring conditions 被引量:3
12
作者 Qing-song Yan Huan Yu +2 位作者 Gang Lu Bo-wen Xiong Suai Xu 《China Foundry》 SCIE 2016年第2期133-138,共6页
The density of vacuum counter-pressure cast aluminum alloy samples under grade-pressuring condition was studied. The effect of grade pressure difference and time on the density of aluminum alloys was discussed, and th... The density of vacuum counter-pressure cast aluminum alloy samples under grade-pressuring condition was studied. The effect of grade pressure difference and time on the density of aluminum alloys was discussed, and the solidification feeding model under grade-pressuring condition was established. The results indicate the grade-pressured solidification feeding ability of vacuum counter-pressure casting mainly depends on grade pressure difference and time. With the increase of grade pressure difference, the density of all the aluminum alloy samples increases, and the trend of change in density from the pouring gate to the top location is first decreasing gradually and then increasing. In addition, in obtaining the maximum density, the optimal grade-pressuring time is different for samples with different wall thicknesses, and the solidification time when the solid volume fraction of aluminum alloy reaches about 0.65 appears to be the optimal beginning time for gradepressuring. 展开更多
关键词 vacuum counter-pressure casting grade-pressuring density solidification feeding
下载PDF
Device-assisted traction methods in colorectal endoscopic submucosal dissection and options for difficult cases 被引量:2
13
作者 Mitsuru Nagata 《World Journal of Gastrointestinal Endoscopy》 2023年第4期265-272,共8页
Endoscopic submucosal dissection(ESD)procedure has a longer procedure time and higher perforation rate than endoscopic mucosal resection owing to technical complications,including a poor field of vision and inadequate... Endoscopic submucosal dissection(ESD)procedure has a longer procedure time and higher perforation rate than endoscopic mucosal resection owing to technical complications,including a poor field of vision and inadequate tension for the submucosal dissection plane.Various traction devices were developed to secure the visual field and provide adequate tension for the dissection plane.Two randomized controlled trials demonstrated that traction devices reduce colorectal ESD procedure time compared with conventional ESD(C-ESD),but they had limitations,including a single-center fashion.The CONNECT-C trial was the first multicenter randomized controlled trial comparing the C-ESD and traction device-assisted ESD(T-ESD)for colorectal tumors.In the T-ESD,one of the device-assisted traction methods(S-O clip,clip-with-line,and clip pulley)was chosen according to the operator’s discretion.The median ESD procedure time(primary endpoint)was not significantly different between C-ESD and T-ESD.For lesions≥30 mm in diameter or in cases treated by nonexpert operators,the median ESD procedure time tended to be shorter in T-ESD than in C-ESD.Although T-ESD did not reduce ESD procedure time,the CONNECT-C trial results suggest that T-ESD is effective for larger lesions and nonexpert operators in colorectal ESD.Compared with esophageal and gastric ESD,colorectal ESD has some difficulties,including poor endoscope maneuverability,which may be associated with prolonged ESD procedure time.T-ESD may not effectively improve these issues,but a balloon-assisted endoscope and underwater ESD may be promising options and these methods can be combined with T-ESD. 展开更多
关键词 Endoscopic submucosal dissection traction traction direction Balloonassisted endoscope Underwater endoscopic submucosal dissection
下载PDF
Cooling System Design Optimization of an Enclosed PM Traction Motor for Subway Propulsion Systems 被引量:1
14
作者 Longnv Li Nan Jia +2 位作者 Xizhe Wang Yiran Yun Gaojia Zhu 《CES Transactions on Electrical Machines and Systems》 CSCD 2023年第4期390-396,共7页
This paper presents the design optimization of a self-circulated ventilation system for an enclosed permanent magnet(PM)traction motor utilized in the propulsion systems for subway trains.In order to analyze accuratel... This paper presents the design optimization of a self-circulated ventilation system for an enclosed permanent magnet(PM)traction motor utilized in the propulsion systems for subway trains.In order to analyze accurately the machine's inherent cooling capacity when the train is running,the ambient airflow and the related heat transfer coefficient(HTC)are numerically investigated considering synchronously the bogie installation structure.The machine is preliminary cooled with air ducts set on the motor shell,and the fluidic-thermal field distributions with only the shell air duct cooling are numerically calculated.During simulations,the HTC obtained in the former steps is applied to the external surface of the machine to model the inherent cooling characteristic caused by the train movement.To reduce the temperature rise and thus guarantee the motor's working reliability,an internal self-circulated air cooling system is proposed according to the machine temperature distribution.The air enclosed in the end-caps is driven by the blades mounted on both sides of the rotor core and forms two air circuits to bring the excessive power losses generated in the heating components to cool regions.The fluid flow and temperature rise distributions of the cooling system's structural parameters are further improved by the Taguchi method in order to confirm the efficacy of the internal air cooling system. 展开更多
关键词 Permanent magnet(PM)traction motor Bogie installation structure Self-circulated ventilation system Taguchi method
下载PDF
Visualized analysis of research on myopic traction maculopathy based on CiteSpace
15
作者 Heng-Di Zhang Ling Zhang +2 位作者 Fei Han Ning Lin Wei Jiang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第12期2117-2124,共8页
AIM:To analyze the global scientific output concerning myopic traction maculopathy(MTM)and to summarize the research frontiers and hot topics of MTM related researches.METHODS:Data were collected for bibliometric and ... AIM:To analyze the global scientific output concerning myopic traction maculopathy(MTM)and to summarize the research frontiers and hot topics of MTM related researches.METHODS:Data were collected for bibliometric and visualization analyses from Web of Science(WOS)Core Collection.Exported records were analyzed for titles,publication years,research institutions,journal names,authors,keywords,and abstracts using CiteSpace software version 6.1.RESULTS:A total of 839 related studies were analyzed,the publication volume increased annually,with Asia the most active region of MTM research.Optical coherence tomography angiography,optical coherence tomography,macular hole,high myopia,macular buckling were identified as the focus of the current research.Progression,association,classification and shape were identified as the major research frontiers.CONCLUSION:MTM is a major cause of visual loss in pathological myopic eyes.During the preceding 17y,the number of annual publications in MTM research increased gradually.Studies on the progression nature of MTM,genome-wide association study and proper classification of MTM might still be the frontiers of MTM researches. 展开更多
关键词 myopic traction maculopathy bibliometric analysis CITESPACE
下载PDF
Damage to the External Genitalia by Traction Following Assault and Battery at the C.H.U Gabriel Touré: About a Case
16
作者 Karembé Boubacar Traoré Boureima +13 位作者 Tounkara Idrissa Diarra Issaka Coulibaly Mamadou Tidiani Soumaré Modibo Dianguina Coulibaly Abdoulaye Camara Aboubacar Touré Aboubacar Sanogo Seydou Fall Ibrahim Diakité Mané Diarra Mouminy Traoré Abdoulaye Diarra Drissa Diakité Mamadou Lamine 《Surgical Science》 2023年第2期55-60,共6页
Trauma to the external genitalia by tearing is rare. We report the case of a 30-year-old patient, admitted to the emergency room for trauma of the external genitalia by traction following a blow and intentional injury... Trauma to the external genitalia by tearing is rare. We report the case of a 30-year-old patient, admitted to the emergency room for trauma of the external genitalia by traction following a blow and intentional injury. The authors highlight the lesions that can occur during this type of trauma and insist on the systematic search for urethral and cavernous lesions. Conclusion: Trauma to the external genitalia by intentional assault and battery is rare in our context. They occur most often in a young person and are frequently associated with damage to the corpora cavernosa and urethra. 展开更多
关键词 TRAUMA External Genitalia traction
下载PDF
Two traction methods that can facilitate esophageal endoscopic submucosal dissection
17
作者 Mitsuru Nagata 《World Journal of Gastrointestinal Endoscopy》 2023年第4期259-264,共6页
Different traction devices that can provide a visual field and attain appropriate tension at the dissection plane during endoscopic submucosal dissection(ESD)have been developed.Clip-with-line(CWL)is a classic tractio... Different traction devices that can provide a visual field and attain appropriate tension at the dissection plane during endoscopic submucosal dissection(ESD)have been developed.Clip-with-line(CWL)is a classic traction device that can offer per-oral traction toward the direction where the line is drawn.A multicenter randomized controlled trial(CONNECT-E trial)comparing the conventional ESD and CWL-assisted ESD(CWL-ESD)for large esophageal tumors was conducted in Japan.This study showed that CWL-ESD was associated with a shorter procedure time(defined as the time from initiating submucosal injection to completing tumor removal)without increasing the risk of adverse events.Multivariate analysis revealed that whole-circumferential lesion and abdominal esophageal lesion were independent risk factors for technical difficulties,which were defined as a procedure time of>120 min,perforation,piecemeal resection,inadvertent incision(any accidental incision caused by the electrosurgical knife within the marked area),or handover to another operator.Therefore,techniques other than CWL should be considered for these lesions.Several studies have shown the usefulness of endoscopic submucosal tunnel dissection(ESTD)for such lesions.A randomized controlled trial conducted at five Chinese institutions showed that compared with the conventional ESD,ESTD had a significantly reduced median procedure time for lesions covering≥1/2 of the esophageal circumference.In addition,a propensity score matching analysis conducted at a single Chinese institution showed that compared with the conventional ESD,ESTD had a shorter mean resection time for lesions at the esophagogastric junction.With the appropriate use of CWL-ESD and ESTD,esophageal ESD can be performed more efficiently and safely.Moreover,the combination of these two methods may be effective. 展开更多
关键词 Endoscopic submucosal dissection traction Clip-with-line Endoscopic submucosal tunnel dissection
下载PDF
轨道交通能量互馈式交流牵引传动综合测试系统的设计 被引量:1
18
作者 李华柏 粟慧龙 邵瑞 《自动化技术与应用》 2024年第1期125-128,共4页
针对轨道交通牵引传动系统性能测试与特性试验需求,设计一种列车交流牵引传动测试系统。系统由四象限整流器、DSP控制单元、牵引变流器、负载变流器、牵引电机与负载电机组成。牵引变流系统采用全新的“双变流器--交流电机负载反馈”方... 针对轨道交通牵引传动系统性能测试与特性试验需求,设计一种列车交流牵引传动测试系统。系统由四象限整流器、DSP控制单元、牵引变流器、负载变流器、牵引电机与负载电机组成。牵引变流系统采用全新的“双变流器--交流电机负载反馈”方案,能量通过直流侧在牵引电机与负载电机之间互馈,避免试验过程中能量的大量消耗。系统可实现牵引变流器的牵引/制动工况性能测试,牵引电机性能测试、特性试验与功率测量,具有高智能化与自动化、安全可靠、测试准确度高、能量利用率高的优点。 展开更多
关键词 能量互馈 牵引电机 牵引变流器 负载变流器 牵引传动
下载PDF
CRH5动车组牵引脉冲整流器自适应优化控制方法研究 被引量:1
19
作者 李蔚 冉治 +2 位作者 孙博 肖友刚 刘哲霖 《铁道科学与工程学报》 EI CAS CSCD 北大核心 2024年第2期476-486,共11页
针对CRH5动车组牵引主回路脉冲整流器在牵引网压波动下的稳定性问题,提出一种基于自抗扰算法的参数自适应优化控制策略。在CRH5动车组牵引脉冲整流器现采用的dq双环控制结构基础上,针对电流内环采用最速综合fal函数实现控制响应及控制... 针对CRH5动车组牵引主回路脉冲整流器在牵引网压波动下的稳定性问题,提出一种基于自抗扰算法的参数自适应优化控制策略。在CRH5动车组牵引脉冲整流器现采用的dq双环控制结构基础上,针对电流内环采用最速综合fal函数实现控制响应及控制量大小随误差变化自适应调整,基于状态空间方程构建一阶线性自抗扰电压外环控制器以实现对系统扰动的观测及跟踪。由此改善控制器对外部扰动的估计及补偿能力,增强控制器对车网耦合特性变化的适应能力。通过Matlab/Simulink仿真对比分析了基于PID控制和基于参数自适应优化控制的dq电流控制器性能,仿真结果表明,基于参数自适应的dq电流优化控制策略下的整流器直流侧输出电压在启动过程中超调量更小,且在应对网压波动时输出电压波动恢复后的稳态误差小于指标值的1/6,抗干扰能力更强。为进一步验证该控制器应对网压低频振荡的抗扰动效果,在RT-LAB半实物实验平台上搭建动车组-牵引网级联耦合模型对比分析2种控制策略下的牵引网网压波形。结果表明:基于参数自适应的dq电流优化控制更能适应多列动车组同时接入而引发的扰动,抑制牵引网网压大幅度振荡;fal电流环的参数自适应特性能改善控制器动态特性,可根据瞬态误差及时调整控制器响应,且其控制参数适应范围较宽,易于整定。 展开更多
关键词 CRH5动车组 牵引脉冲整流器 自抗扰控制 牵引网网压 低频振荡
下载PDF
新型混合式贯通牵引供电系统及其复合控制策略 被引量:2
20
作者 王鑫 郭祺 +2 位作者 涂春鸣 肖凡 侯玉超 《中国电机工程学报》 EI CSCD 北大核心 2024年第3期981-991,I0011,共12页
电分相与负序等电能质量问题是制约电气化铁路向高速化、重载化发展的桎梏。贯通牵引供电系统为消弭上述问题提供了契机,但既有贯通方案依然存在所需器件数目多、改造成本高、可靠性差等弊端。为此,在充分利用既有牵引变压器基础上,该... 电分相与负序等电能质量问题是制约电气化铁路向高速化、重载化发展的桎梏。贯通牵引供电系统为消弭上述问题提供了契机,但既有贯通方案依然存在所需器件数目多、改造成本高、可靠性差等弊端。为此,在充分利用既有牵引变压器基础上,该文设计一种新型混合式贯通牵引供电装置。该装置通过共直流侧与功率均分手段有效抵消输入侧纹波功率,降低有源/无源器件数目与电容容量。同时,针对直流侧二次纹波与负荷功率冲击,提出一种输入端口复合控制策略,有效解决纹波传递与冲击波动问题。最后通过仿真与实验验证所提装置及其控制策略的可行性与可靠性。 展开更多
关键词 新型混合式 牵引供电装置 公共直流母线 复合控制
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部