期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Electromagnetic interference assessment of a train-network-pipeline coupling system based on a harmonic transmission model
1
作者 Minwu Chen Jinyu Zhao +2 位作者 Zongyou Liang Xin Gong Yu Cao 《Railway Engineering Science》 2023年第4期396-410,共15页
The harmonics and resonance of traction power supply systems(TPSSs)aggravate the electromagnetic interference(EMI)to adjacent metallic pipelines(MPs),which has aroused widespread concern.In this paper,an evaluation me... The harmonics and resonance of traction power supply systems(TPSSs)aggravate the electromagnetic interference(EMI)to adjacent metallic pipelines(MPs),which has aroused widespread concern.In this paper,an evaluation method on pipeline interference voltage under harmonic induction is presented.The results show that the Carson integral formula is more accurate in calculating the mutual impedance at higher frequencies.Then,an integrated train-network-pipeline model is established to estimate the influences of harmonic distortion and resonance on an MP.It is revealed that the higher the harmonic cur-rent distortion rate of the traction load,the larger the interference voltage on an MP.Particularly,the interference voltage is amplified up to 7 times when the TPSS resonates,which is worthy of attention.In addition,the parameters that affect the variation and sensitivity of the interference voltage are studied,namely,the pipeline coating material,locomotive position,and soil resistivity,indicating that soil resistivity and 3PE(3-layer polyethylene)anticorrosive coating are more sensitive to harmonic induction.Field test results show that the harmonic distortion can make the interference voltage more serious,and the protective measures are optimized. 展开更多
关键词 Induced voltage Inductive coupling Conductive coupling Harmonic resonance Electromagnetic interference
下载PDF
Analysis on conducted coupling of electrical fast transient burst in mines 被引量:1
2
作者 FENG De-wang LAN Jian-rong 《Journal of Coal Science & Engineering(China)》 2012年第2期207-212,共6页
Under the inflammable or explosive environment, the direct measurement methods by opening up the explo- sion-proof shell of electrical installations were not adopted. So, it's impossible to have a quantitative analys... Under the inflammable or explosive environment, the direct measurement methods by opening up the explo- sion-proof shell of electrical installations were not adopted. So, it's impossible to have a quantitative analysis on the limit of conducted disturbance for electrical fast transient burst (EFT/B) in such dangerous environments. Transient conducted coupling model, which using EFT/B as its excitation source, can be built based on circuit and electromagnetic field theory. Furthermore, numerical analysis was performed. The results indicate that the capacitive coupling voltage is the same polarity as EFT/B, and is the main disturbance form of conducted coupling in mines. The inductive coupling voltage is reversed polarity with the ca- pacitive coupling voltage, and both peaks appear only in the rising time of EFT/B, which increase with the rising of load resistance. Moreover, the cable coupling voltage on the side of disturbance source is higher than the one on the other side in tunnel. To reduce the common resistance can suppress the resistive coupling disturbance. 展开更多
关键词 conducted coupling electrical fast transient burst numerical analysis
下载PDF
Heat and Mass Transfer by Natural Convection during Transpiration trough a Porous Plate
3
作者 Abderraouf Sabri Mohamed Asbik 《Energy and Power Engineering》 CAS 2022年第12期719-736,共18页
Cooling by evaporation through transpiring porous walls is expanding in various industrial applications such as air conditioning. It is also used to cool water in a clay jug. This process deserves to be studied, under... Cooling by evaporation through transpiring porous walls is expanding in various industrial applications such as air conditioning. It is also used to cool water in a clay jug. This process deserves to be studied, understood and valued. This paper deals with the transpiration phenomenon through a saturated porous plate coupled with heat and mass transfer by natural convection. Conservation Equations (mass, momentum, energy and concentration), associated with adequate boundary conditions, have been numerically solved using an implicit finite difference iterative method. The numerical model has been validated by experimental measurements from holographic interferometry. The used method to obtain temperature and concentration profiles was explained. They are evaluated from the refractive index of moisture air in the boundary layer. The main numerical results presented are: Nusselt and Sherwood numbers, temperature, humidity, and velocity profiles within the boundary layer as well as the different heat fluxes exchanged between the plate and the surrounding environment. Besides, the present model allows showing the important effect of the equivalent thermal conductivity and the surface emissivity on temperature and heats flux. 展开更多
关键词 TRANSPIRATION Natural Convection conduction Convection Coupling Surface Radiation Holographic Interferometry
下载PDF
The First-Order Comprehensive Sensitivity Analysis Methodology (1<sup>st</sup>-CASAM) for Scalar-Valued Responses: II. Illustrative Application to a Heat Transport Benchmark Model
4
作者 Dan Gabriel Cacuci 《American Journal of Computational Mathematics》 2020年第2期290-310,共21页
This work illustrates the application of the 1<sup>st</sup>-CASAM to a paradigm heat transport model which admits exact closed-form solutions. The closed-form expressions obtained in this work for the sens... This work illustrates the application of the 1<sup>st</sup>-CASAM to a paradigm heat transport model which admits exact closed-form solutions. The closed-form expressions obtained in this work for the sensitivities of the temperature distributions within the model to the model’s parameters, internal interfaces and external boundaries can be used to benchmark commercial and production software packages for simulating heat transport. The 1<sup>st</sup>-CASAM highlights the novel finding that response sensitivities to the imprecisely known domain boundaries and interfaces can arise both from the definition of the system’s response as well as from the equations, interfaces and boundary conditions that characterize the model and its imprecisely known domain. By enabling, in premiere, the exact computations of sensitivities to interface and boundary parameters and conditions, the 1<sup>st</sup>-CASAM enables the quantification of the effects of manufacturing tolerances on the responses of physical and engineering systems. 展开更多
关键词 First-Order Comprehensive Adjoint Sensitivity Analysis Methodology (1st-CASAM) Response Sensitivities for coupled Systems Involving Imprecisely Known Interfaces Parameters And Boundaries coupled Heat conduction and Convection
下载PDF
A critical transition rule for broadening exponent of fluctuation and its effect on dissipation in chemical reaction-heat conduction coupling systems
5
作者 LIN Feng ZHAO NanRong LUO JiuLi 《Science China Chemistry》 SCIE EI CAS 2011年第5期774-781,共8页
A stochastic model of chemical reaction-heat conduction-diffusion for a one-dimensional gaseous system under Dirichlet or zero-fluxes boundary conditions is proposed in this paper. Based on this model,we extend the th... A stochastic model of chemical reaction-heat conduction-diffusion for a one-dimensional gaseous system under Dirichlet or zero-fluxes boundary conditions is proposed in this paper. Based on this model,we extend the theory of the broadening exponent of critical fluctuations to cover the chemical reaction-heat conduction coupling systems as an asymptotic property of the corresponding Markovian master equation (ME),and establish a valid stochastic thermodynamics for such systems. As an illustration,the non-isothermal and inhomogeneous Schl-gl model is explicitly studied. Through an order analysis of the contributions from both the drift and diffusion to the evolution of the probability distribution in the corresponding Fokker-Planck equation(FPE) in the approach to bifurcation,we have identified the critical transition rule for the broadening exponent of the fluctuations due to the coupling between chemical reaction and heat conduction. It turns out that the dissipation induced by the critical fluctuations reaches a deterministic level,leading to a thermodynamic effect on the nonequilibrium physico-chemical processes. 展开更多
关键词 stochastic model of chemical reaction–heat conduction–diffusion systems stochastic thermodynamics of chemical reaction–heat conduction coupling processes broadening exponent of critical fluctuation entropy production of fluctuations fluctuation–dissipation effect
原文传递
Breaking efficiency limit of thermal concentrators by conductivity couplings 被引量:1
6
作者 Pengfei Zhuang Liujun Xu +2 位作者 Peng Tan Xiaoping Ouyang Jiping Huang 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS CSCD 2022年第11期68-77,共10页
The concentrating efficiency of a thermal concentrator can be reflected in the ratio of its interior to exterior temperature gradients,which, however, has an upper limit in existing schemes. Here, we manage to break t... The concentrating efficiency of a thermal concentrator can be reflected in the ratio of its interior to exterior temperature gradients,which, however, has an upper limit in existing schemes. Here, we manage to break this upper limit by considering the couplings of thermal conductivities and improve the concentrating efficiency of thermal concentrators. For this purpose, we first discuss a monolayer scheme with an isotropic thermal conductivity, which can break the upper limit but is still restricted by its geometric configuration. To go further, we explore another degree of freedom by considering the monolayer scheme with an anisotropic thermal conductivity or by adding the second shell with an isotropic thermal conductivity, thereby making the concentrating efficiency completely free from the geometric configuration. Nevertheless, apparent negative thermal conductivities are required, and we resort to external heat sources realizing the same effect without violating the second law of thermodynamics. Finite-element simulations are performed to confirm the theoretical predictions, and experimental suggestions are also provided to improve feasibility. These results may have potential applications for thermal camouflage and provide guidance to other diffusive systems such as static magnetic fields and dc current fields for achieving similar behaviors. 展开更多
关键词 thermal concentrator concentrating efficiency conductivity coupling apparent negative conductivity
原文传递
Sensitive Determination of Five Priority Haloacetic Acids by Electromembrane Extraction with Capillary Electrophoresis
7
作者 Xiaoli Zhang Haitao Zhang +3 位作者 Yan Liu Lin Guo Jiannong Ye Qingcui Chu 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2015年第2期235-240,共6页
A method for sensitive determination of five priority haloacetic acids in drinking water has been developed for the first time based on electromembrane extraction(EME)prior to CZE with capacitively coupled contactless... A method for sensitive determination of five priority haloacetic acids in drinking water has been developed for the first time based on electromembrane extraction(EME)prior to CZE with capacitively coupled contactless conductivity detection(CZE-C^(4)D).The target analytes were extracted from 10 mL of the sample solution(donor phase),through the supported liquid membrane(using a polypropylene membrane supporting 1-octanol),and into 10μL of 50 mmol/L NaAc solution(acceptor phase).The extracted solution was directly analyzed by CZE-C^(4)D without de-rivatization.Several factors that affect separation,detection and extraction efficiency were investigated.Under the optimum conditions,five haloacetic acids(monochloroacetic acid,dichloroacetic acid,trichloroacetic acid,mono-bromoacetic acid,and dibromoacetic acid)could be well separated from other components coexisting in water samples within 23 min,exhibiting a linear calibration over two orders of magnitude(r≥0.9943);the enrichment factors at 430-671 were obtained in a 30 min of extraction,and the limits of detection were in the range of 0.17-0.61 ng/mL.The intraday relative standard deviations for peak areas investigated at 10 ng/mL were between 1.2%and 9.7%for the combined EME-CZE-C^(4)D procedure.This approach offers an attractive alternative to the officially proposed method for purified drinking water analysis,which requires derivatization procedure prior to gas chromatography analysis. 展开更多
关键词 disinfection byproducts haloacetic acids electromembrane extraction capillary electrophoresis ca-pacitively coupled contactless conductivity detection purified drinking water
原文传递
Simple and cost-effective determination of ciprofloxacin hydrochloride by electrical micro-titration
8
作者 Xu-Zhi Zhang Meng-Shi Huang +4 位作者 Qian-Qian Yang Dong-Sheng Ding Jun Zhao Wen-Rong Yang Ke-Ming Qu 《Chinese Chemical Letters》 SCIE CAS CSCD 2017年第7期1406-1412,共7页
By employing an electrical micro-titration system, in which a capacitively coupled contactless conductivity detector(C^4D) was used to monitor the reaction process in real time, herein a novel method for determining... By employing an electrical micro-titration system, in which a capacitively coupled contactless conductivity detector(C^4D) was used to monitor the reaction process in real time, herein a novel method for determining ciprofloxacin hydrochloride(CIPHCl) was developed for the first time. Mode 1: Standard CIPHCl solutions at different concentrations were loaded into reaction cells, respectively, and were titrated with standard Ag^+. Upon the titration, the formation of a precipitate alters the number of ions in the solution, raising the change of conductivity, which was monitored by a special C-4 D to construct a titration curve. The endpoint of the titration was located from the peak of the curve. Between the elapsed time and the initial concentration of titrand, a linear relationship was established over the range of2.0–8.0 mmol/L. Mode 2: Standard Fe^3+ took the place of Ag^+, and was used as titrant to recognize ciprofloxacin contributed to the formation of complexation, which also resulting a change of solution conductivity. Under optimized conditions, a working range of 1.0–5.0 mmol/L CIPHCl was found. Because the reaction solutions were isolated from the working electrodes, this pioneer work shows significant simplicity and cost-effectiveness, by eliminating the requirements for detector exchange/renewal between different measurements, and by involving no auxiliary chemicals. Both of the two approaches were applied successfully to determine CIPHCl in tablet samples. And the results were in good agreement with those obtained by reference method. 展开更多
关键词 Ciprofloxacin hydrochloride Determination Micro-titration Capacitively coupled contactless conductivity detector Pharmaceutical analysis
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部