The moisture performance of building envelopes largely depends on the building materials,construction tech-niques,and exposure loads from the indoor and outdoor regions.A ventilated air interlayer placed in a wall can...The moisture performance of building envelopes largely depends on the building materials,construction tech-niques,and exposure loads from the indoor and outdoor regions.A ventilated air interlayer placed in a wall can help dehumidify the wall and indoor air.This paper presents an experimental study of the heat,air,and moisture variations within the envelope wall of a chamber featuring different air interlayer settings under real outdoor air conditions during the summer of 2020 in Shanghai,China.Self-developed humidity-controlling building mate-rials were applied to the inner building envelope.Temperature,humidity,wind velocity,and heat-flow sensors were placed at different positions in the middle of the wall.These parameters were measured and recorded in real-time under three working conditions:humidification,dehumidification,and ventilation.The experimental results show that under the ventilation working conditions,moisture content of 0.52 kg can be removed after a 2-h air layer ventilation,which can benefit the design strategy for the humidification and ventilation of dehu-midification walls.展开更多
基金financially supported by the National Natural Science Foundation of China(No.51778358)the Shanghai Municipality Natural Science Foundation(No.21ZR1434400)Sponsored by Key Laboratory of New Technology for Construction of Cities in Mountain Area,Ministry of Education,Chongqing University,Chongqing 400045,China(LNTCCMA-20210103).
文摘The moisture performance of building envelopes largely depends on the building materials,construction tech-niques,and exposure loads from the indoor and outdoor regions.A ventilated air interlayer placed in a wall can help dehumidify the wall and indoor air.This paper presents an experimental study of the heat,air,and moisture variations within the envelope wall of a chamber featuring different air interlayer settings under real outdoor air conditions during the summer of 2020 in Shanghai,China.Self-developed humidity-controlling building mate-rials were applied to the inner building envelope.Temperature,humidity,wind velocity,and heat-flow sensors were placed at different positions in the middle of the wall.These parameters were measured and recorded in real-time under three working conditions:humidification,dehumidification,and ventilation.The experimental results show that under the ventilation working conditions,moisture content of 0.52 kg can be removed after a 2-h air layer ventilation,which can benefit the design strategy for the humidification and ventilation of dehu-midification walls.