Given a set U which is consisted of strings defined on alphabet Σ, string cross pattern matching is to find all the matches between every two strings in U. It is utilized in text processing like removing the duplicat...Given a set U which is consisted of strings defined on alphabet Σ, string cross pattern matching is to find all the matches between every two strings in U. It is utilized in text processing like removing the duplication of strings. This paper presents a fast string cross pattern matching algorithm based on extracting high frequency strings. Compared with existing algorithms including single-pattern algorithms and multi-pattern matching algorithms, this algorithm is featured by both low time complexity and low space complexity. Because Chinese alphabet is large and the average length of Chinese words is much short, this algorithm is more suitable to process the text written by Chinese, especially when the size of Σ is large and the number of strings is far more than the maximum length of strings of set U.展开更多
目的观察血小板自身抗体与同种抗体对血小板交叉配型难易程度及输注效果的影响。方法选择2021年7月—2023年9月在本实验室完成血小板抗体鉴定的106例血小板输注无效(PTR)患者,根据血小板抗体类型将患者分为两组,20例自身抗体阳性患者为...目的观察血小板自身抗体与同种抗体对血小板交叉配型难易程度及输注效果的影响。方法选择2021年7月—2023年9月在本实验室完成血小板抗体鉴定的106例血小板输注无效(PTR)患者,根据血小板抗体类型将患者分为两组,20例自身抗体阳性患者为观察组,86例同种抗体阳性患者为对照组。比较两组患者配型相合次数百分率、配型相合供者百分率、输注交叉配型相合血小板及随机血小板的24 h血小板计数增加指数(CCI)值及输注有效率的差异,并对观察组自身抗体变化情况进行追踪。结果观察组的配型相合次数百分率及配型相合供者百分率均高于对照组(P<0.05)。观察组患者输注交叉配型相合血小板与随机血小板的24 h CCI值及输注有效率均无显著性差异(P>0.05),对照组患者输注交叉配型相合血小板的24 h CCI值及输注有效率均高于输注随机血小板(P<0.001),对照组患者输注交叉配型相合血小板后24 h CCI值及输注有效率比观察组高(P<0.05),对照组和观察组输注随机血小板后24 h CCI值及输注有效率无显著性差异(P>0.05)。观察组多数患者的自身抗体强度呈下降趋势。结论血小板自身抗体对血小板交叉配型难易程度及输注效果的影响比同种抗体小。血小板自身抗体强度随时间推移呈现逐渐下降乃至消失的规律。在临床实践中,对于自身抗体患者的治疗,应当首先查找病因,并进行针对性治疗,如果需要输注血小板,可以选择输注随机血小板。展开更多
视差不连续区域和重复纹理区域的误匹配率高一直是影响双目立体匹配测量精度的主要问题,为此,本文提出一种基于多特征融合的立体匹配算法。首先,在代价计算阶段,通过高斯加权法赋予邻域像素点的权值,从而优化绝对差之和(Sum of Absolute...视差不连续区域和重复纹理区域的误匹配率高一直是影响双目立体匹配测量精度的主要问题,为此,本文提出一种基于多特征融合的立体匹配算法。首先,在代价计算阶段,通过高斯加权法赋予邻域像素点的权值,从而优化绝对差之和(Sum of Absolute Differences,SAD)算法的计算精度。接着,基于Census变换改进二进制链码方式,将邻域内像素的平均灰度值与梯度图像的灰度均值相融合,进而建立左右图像对应点的判断依据并优化其编码长度。然后,构建基于十字交叉法与改进的引导滤波器相融合的聚合方法,从而实现视差值再分配,以降低误匹配率。最后,通过赢家通吃(Winner Take All,WTA)算法获取初始视差,并采用左右一致性检测方法及亚像素法提高匹配精度,从而获取最终的视差结果。实验结果表明,在Middlebury数据集的测试中,所提SAD-Census算法的平均非遮挡区域和全部区域的误匹配率为分别为2.67%和5.69%,测量200~900 mm距离的平均误差小于2%;而实际三维测量的最大误差为1.5%。实验结果检验了所提算法的有效性和可靠性。展开更多
文摘Given a set U which is consisted of strings defined on alphabet Σ, string cross pattern matching is to find all the matches between every two strings in U. It is utilized in text processing like removing the duplication of strings. This paper presents a fast string cross pattern matching algorithm based on extracting high frequency strings. Compared with existing algorithms including single-pattern algorithms and multi-pattern matching algorithms, this algorithm is featured by both low time complexity and low space complexity. Because Chinese alphabet is large and the average length of Chinese words is much short, this algorithm is more suitable to process the text written by Chinese, especially when the size of Σ is large and the number of strings is far more than the maximum length of strings of set U.
文摘目的观察血小板自身抗体与同种抗体对血小板交叉配型难易程度及输注效果的影响。方法选择2021年7月—2023年9月在本实验室完成血小板抗体鉴定的106例血小板输注无效(PTR)患者,根据血小板抗体类型将患者分为两组,20例自身抗体阳性患者为观察组,86例同种抗体阳性患者为对照组。比较两组患者配型相合次数百分率、配型相合供者百分率、输注交叉配型相合血小板及随机血小板的24 h血小板计数增加指数(CCI)值及输注有效率的差异,并对观察组自身抗体变化情况进行追踪。结果观察组的配型相合次数百分率及配型相合供者百分率均高于对照组(P<0.05)。观察组患者输注交叉配型相合血小板与随机血小板的24 h CCI值及输注有效率均无显著性差异(P>0.05),对照组患者输注交叉配型相合血小板的24 h CCI值及输注有效率均高于输注随机血小板(P<0.001),对照组患者输注交叉配型相合血小板后24 h CCI值及输注有效率比观察组高(P<0.05),对照组和观察组输注随机血小板后24 h CCI值及输注有效率无显著性差异(P>0.05)。观察组多数患者的自身抗体强度呈下降趋势。结论血小板自身抗体对血小板交叉配型难易程度及输注效果的影响比同种抗体小。血小板自身抗体强度随时间推移呈现逐渐下降乃至消失的规律。在临床实践中,对于自身抗体患者的治疗,应当首先查找病因,并进行针对性治疗,如果需要输注血小板,可以选择输注随机血小板。
文摘视差不连续区域和重复纹理区域的误匹配率高一直是影响双目立体匹配测量精度的主要问题,为此,本文提出一种基于多特征融合的立体匹配算法。首先,在代价计算阶段,通过高斯加权法赋予邻域像素点的权值,从而优化绝对差之和(Sum of Absolute Differences,SAD)算法的计算精度。接着,基于Census变换改进二进制链码方式,将邻域内像素的平均灰度值与梯度图像的灰度均值相融合,进而建立左右图像对应点的判断依据并优化其编码长度。然后,构建基于十字交叉法与改进的引导滤波器相融合的聚合方法,从而实现视差值再分配,以降低误匹配率。最后,通过赢家通吃(Winner Take All,WTA)算法获取初始视差,并采用左右一致性检测方法及亚像素法提高匹配精度,从而获取最终的视差结果。实验结果表明,在Middlebury数据集的测试中,所提SAD-Census算法的平均非遮挡区域和全部区域的误匹配率为分别为2.67%和5.69%,测量200~900 mm距离的平均误差小于2%;而实际三维测量的最大误差为1.5%。实验结果检验了所提算法的有效性和可靠性。