New modified combination mathematical models including the pores blocking models and the cake layer models were developed to describe the continuous cross-flow microfiltration in an airlift external loop slurry reacto...New modified combination mathematical models including the pores blocking models and the cake layer models were developed to describe the continuous cross-flow microfiltration in an airlift external loop slurry reactor. The pores blocking models were created based on the standard blocking law and the intermediate blocking law, and then the cake layer models were developed based on the hydrodynamic theory in which the calculation method of porosity of cake layer was newly corrected. The Air-Water-FCC equilibrium catalysts cold model experiment was used to verify the relevant models.Results showed that the calculated values fitted well with experimental data with a relative error of less than 10%.展开更多
Experimental investigation of the microfiltration (MF) using a revolving cross-flow membrane filter was performed under the condition of constant pressure difference, and different flat membranes made of polyvinylid...Experimental investigation of the microfiltration (MF) using a revolving cross-flow membrane filter was performed under the condition of constant pressure difference, and different flat membranes made of polyvinylidene fluoride (PVDF, 0.1 μm), cellulose acetate (CA, 0.22 μm), sulfonated polyethersulfone (SPES, 0.22 μm) and polyamide (PA, 0.45 μm), respectively, were used in filtration experiments. The dependence of the filtrate mass of the cross-flow MF on time was measured on-line. The experimental results showed that the effect of the cross-flow on high viscosity medium was more significant than that on the low viscosity one.展开更多
A cross-flow microfiltration process had been developed to separate alumina fine particles from the suspension using a stainless steel membrane tube with a pore size of 10 μm. The influence of cross-flow velocity and...A cross-flow microfiltration process had been developed to separate alumina fine particles from the suspension using a stainless steel membrane tube with a pore size of 10 μm. The influence of cross-flow velocity and trans-membrane pressure on the permeate flux and the solid holdup in permeate had been investigated. It was found that both the permeate flux and the solid holdup in permeate decreased with time. Moreover, the permeate flux increased with an increasing transmembrane pressure but the influence of cross-flow velocity on the permeate flux was quite complex. Both the permeate flux and the solid holdup in permeate in long term filtration had been studied. The operation of cross-flow microfiltration could be carried out stably for 10 hours with the permeate flux values ranging from 520.5 to 936 L/(m^2·h) at rs=1%, while it could continue in 10 hours with the permeate flux values ranging from 226 to 432 L/(m^2·h) at rs=5%. The solid holdup in permeate had been less than 10 mg/L during the whole operating cycle.展开更多
基金financially supported by the National Key Research & Development Program of China (2016YFB0301600)
文摘New modified combination mathematical models including the pores blocking models and the cake layer models were developed to describe the continuous cross-flow microfiltration in an airlift external loop slurry reactor. The pores blocking models were created based on the standard blocking law and the intermediate blocking law, and then the cake layer models were developed based on the hydrodynamic theory in which the calculation method of porosity of cake layer was newly corrected. The Air-Water-FCC equilibrium catalysts cold model experiment was used to verify the relevant models.Results showed that the calculated values fitted well with experimental data with a relative error of less than 10%.
基金Supported by the State Key Development Program for Basic Research of China(2003CB615705)
文摘Experimental investigation of the microfiltration (MF) using a revolving cross-flow membrane filter was performed under the condition of constant pressure difference, and different flat membranes made of polyvinylidene fluoride (PVDF, 0.1 μm), cellulose acetate (CA, 0.22 μm), sulfonated polyethersulfone (SPES, 0.22 μm) and polyamide (PA, 0.45 μm), respectively, were used in filtration experiments. The dependence of the filtrate mass of the cross-flow MF on time was measured on-line. The experimental results showed that the effect of the cross-flow on high viscosity medium was more significant than that on the low viscosity one.
文摘A cross-flow microfiltration process had been developed to separate alumina fine particles from the suspension using a stainless steel membrane tube with a pore size of 10 μm. The influence of cross-flow velocity and trans-membrane pressure on the permeate flux and the solid holdup in permeate had been investigated. It was found that both the permeate flux and the solid holdup in permeate decreased with time. Moreover, the permeate flux increased with an increasing transmembrane pressure but the influence of cross-flow velocity on the permeate flux was quite complex. Both the permeate flux and the solid holdup in permeate in long term filtration had been studied. The operation of cross-flow microfiltration could be carried out stably for 10 hours with the permeate flux values ranging from 520.5 to 936 L/(m^2·h) at rs=1%, while it could continue in 10 hours with the permeate flux values ranging from 226 to 432 L/(m^2·h) at rs=5%. The solid holdup in permeate had been less than 10 mg/L during the whole operating cycle.