期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Impact of Crude Oil Storage Tank Emissions and Gas Flaring on Air/Rainwater Quality and Weather Conditions in Bonny Industrial Island, Nigeria 被引量:1
1
作者 Vincent Ezikornwor Weli Nsikak I. Itam 《Open Journal of Air Pollution》 2016年第2期44-54,共11页
This study investigated the effects of gaseous emissions from crude storage tank and gas flaring on air and rainwater quality in Bonny Industrial Island. Ambient air quality parameters, rainwater and weather parameter... This study investigated the effects of gaseous emissions from crude storage tank and gas flaring on air and rainwater quality in Bonny Industrial Island. Ambient air quality parameters, rainwater and weather parameters were collected at 60 m, 80 m, 100 m, 200 m and control plot for 4 weeks at the Bonny. Rainwater parameters were investigated using standard laboratory tests. Data analyses were done using Analysis of variance, pairwise t-test and Pearson’s correlation statistical tools. Results show that emission rates, volatile organic compound (VOC) noise and flare temperature decreased with increasing distance from flare points and crude oil storage tanks. Findings further revealed the emission rates varied significantly with distance away from the gas flaring point (F = 6.196;p = 0.004). The mean concentration of pollutants between gas flare site and crude oil storage tank showed that CO (0.02 ± 0.001 - 0.002 ±0.001), SPM (0.011 ± 0.001 - 0.01 ± 0.001), VOC (0.005 ± 0.001 - 0.01 ± 0.001) and NO<sub>2</sub> (0.04 ± 0.001 - 0.005 ± 0.000) had significant variations (p > 0.05) with CO, O<sub>3</sub> and NO<sub>2</sub> having higher concentrations at the gas flare site while SPM, and VOC were higher around the crude oil storage tank site. Wind turbulence was higher around the gas flaring point (4.93 TKE) than the crude oil storage tank (4.55 TKE). Similarly, there was significant variation in the sun radiation, precipitation, and wind speed caused by gas flaring (1582.25 w/m<sup>2</sup>, 436.25 mm, 0.53 m/s) and crude oil storage tank (1536.25 w/m<sup>2</sup>, 3.91.41 mm, 0.51 m/s). There were also significant variations in flared temperature (F = 22.144;p = 0.001);NO<sub>2</sub> (F = 8.250;p = 0.001), CO (F = 6.000;p = 0.004) and VOC (F = 5.574;p = 0.006) with distance from the gas flaring point. The variation in the rainwater parameters with distance from the gas flaring indicated significant variations in pH (F = 5.594;p = 0.006). The study showed that the concentration of VOC and particulates were high in the supposedly control area which is perceived to be safe for human habitation. Significant variations exist in emission rate (p = 0.015), flare temperature (p = 0.001), NO<sub>2</sub> (p = 0.003), VOC (p = 0.001), noise (p = 0.041), hydrogen carbonate (p = 0.037) and chromium (p = 0.032) between the gas flaring and crude oil storage tank. Regular monitoring is advocated to mitigate the harmful effects of the pollutants. 展开更多
关键词 gas Flaring crude oil tank Air Quality RAINWATER Meteorological Parameters
下载PDF
安全防护对原油罐区多米诺火灾事故发生概率的影响 被引量:9
2
作者 伍壮 侯磊 +1 位作者 伍星光 刘婉莹 《安全与环境工程》 CAS 北大核心 2020年第1期166-172,共7页
目前原油罐区的多米诺效应火灾风险分析中,未考虑罐区配备的各类安全防护。为在火灾风险分析的事故发生概率计算中考虑安全防护的性能,提出可用性和有效性两个概念对原油罐区的安全防护性能进行量化,采用事件树分析法确定考虑安全防护... 目前原油罐区的多米诺效应火灾风险分析中,未考虑罐区配备的各类安全防护。为在火灾风险分析的事故发生概率计算中考虑安全防护的性能,提出可用性和有效性两个概念对原油罐区的安全防护性能进行量化,采用事件树分析法确定考虑安全防护时的原油罐区多米诺火灾事故扩展概率。以2储罐罐区为例,浮顶全表面池火灾发生后,计算出考虑安全防护时罐区各储罐单元的池火灾事故扩展概率3.89×10^-2与未考虑安全防护时罐区各储罐单元的池火灾事故扩展概率7.46×10^-1相比,两者相差一个数量级;对于6储罐罐区,考虑安全防护与未考虑安全防护时罐区各储罐单元的池火灾事故发生概率相差将近4倍,表明安全防护在预防原油罐区多米诺火灾事故中起着重要作用。 展开更多
关键词 原油罐区 安全防护 多米诺效应 火灾事故 扩展概率 事件树分析 贝叶斯网络
下载PDF
PIPENET在油气储罐区消防系统水力模拟中的应用 被引量:3
3
作者 梅欢 连广宇 《工业用水与废水》 CAS 2019年第4期46-48,共3页
采用美国NFPA和API系列标准,结合某大型油气储罐区的消防布置要求,分析和比较了油气储罐区内各构筑物火灾工况时的消防用水量。选取消防水量较大的2种火灾工况,通过PIPENET软件进行火灾发生时的水力模拟分析并优化设计内容,校核消防水量... 采用美国NFPA和API系列标准,结合某大型油气储罐区的消防布置要求,分析和比较了油气储罐区内各构筑物火灾工况时的消防用水量。选取消防水量较大的2种火灾工况,通过PIPENET软件进行火灾发生时的水力模拟分析并优化设计内容,校核消防水量,提供消防泵的选型参数。 展开更多
关键词 油气储罐区 PIPENET软件 美国消防规范 水力模拟分析
下载PDF
某石化公司原油罐区安全风险分析及防控 被引量:3
4
作者 卜文闯 《化工管理》 2021年第23期95-96,共2页
通过定量分析,确定原油罐区重大危险源级别,分析运行过程中的风险,通过制定各种风险防控措施,可以有效解决原油罐区重大危险源的安全管理问题。
关键词 原油罐区 重大危险源 安全风险 控制措施
下载PDF
原油储罐区的危险性分析及对策
5
作者 朱东升 竺栋荣 胡海兰 《绿色科技》 2009年第1期30-35,共6页
由于石油产品具有易燃、易爆、易挥发、有腐蚀性及毒性等特性,使其在储运过程中存在潜在的事故风险,稍有不慎就会酿成重大事故,给人们的生命财产造成破坏和损失。因而有必要对潜在风险进行评估并对风险的不确定性有所了解。罐区作为... 由于石油产品具有易燃、易爆、易挥发、有腐蚀性及毒性等特性,使其在储运过程中存在潜在的事故风险,稍有不慎就会酿成重大事故,给人们的生命财产造成破坏和损失。因而有必要对潜在风险进行评估并对风险的不确定性有所了解。罐区作为石油及产品的主要储存区域,担负着液态油品和可燃气体的收发储存任务。本文以某原油储罐区为研究对象,分别采用事故树分析法、美国道化学公司火灾、爆炸危险指数法(第七版)对其事故原因及其危害性进行分析,评价各因素导致事故发生的影响程度,在此基础上提出了的相应安全防范措施,为降低罐区危险等级提供依据。 展开更多
关键词 原油储罐 事故树 道化学 爆炸 分析 控制
下载PDF
基于Profibus-DP总线技术的PLC控制系统在新港原油罐区工程中的应用
6
作者 姜文斌 周珩 冯志刚 《港口科技》 2009年第6期41-43,共3页
Profibus是一种应用较为广泛的现场总线。通过对控制系统和Profibus-DP现场总线技术特点和优势的介绍,说明该技术在大连港新港原油罐区工程控制系统中的应用是值得肯定的,其优势得到了明显的验证具有极大的推广价值。
关键词 Profibus—DP 现场总线 优点 原油罐区工程
下载PDF
上一页 1 下一页 到第