期刊文献+
共找到2,978篇文章
< 1 2 149 >
每页显示 20 50 100
Robust Nonlinear Current Sensorless Control of the Boost Converter with Constant Power Load
1
作者 Said Oucheriah Abul Azad 《Circuits and Systems》 2024年第3期29-43,共15页
The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the ... The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the design of stabilizing controllers. A PWM-based current-sensorless robust sliding mode controller is developed that requires only the measurement of the output voltage. An extended state observer is developed to estimate a lumped uncertainty signal that comprises the uncertain load power and the input voltage, the converter parasitics, the component uncertainties and the estimation of the derivative of the output voltage needed in the implementation of the controller. A linear sliding surface is used to derive the controller, which is simple in its design and yet exhibits excellent features in terms of robustness to external disturbances, parameter uncertainties, and parasitics despite the absence of the inductor’s current feedback. The robustness of the controller is validated by computer simulations. 展开更多
关键词 Boost Converter Robust Sliding Mode Control constant Power Load (CPL) current-Sensorless Control Extended State Observer
下载PDF
Constant frequency operation of parallel resonant converter for constant-current constant-voltage battery charger applications 被引量:1
2
作者 Taha Nurettin GüCIN Muhammet BIBEROGLU Bekir FINCAN 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2019年第1期186-199,共14页
This paper proposes a design and control approach to parallel resonant converter(PRC) based battery chargers.The proposed approach is particularly suitable for the constant-current constant-voltage(CC-CV)charging meth... This paper proposes a design and control approach to parallel resonant converter(PRC) based battery chargers.The proposed approach is particularly suitable for the constant-current constant-voltage(CC-CV)charging method, which is the most commonly utilized one.Since the PRC is operated at two different frequencies for each CC and CV charging modes, this approach eliminates the need for complicated control techniques such as the frequency-control and phase-shift-control.The proposed method not only simplifies the design and implementation processes of the converter unit but also simplifies the design of output filter configuration and decreases the number of the required components for the control of the charger.The proposed method is confirmed by two experimental setups.The results show that the designed charger circuit ensured a very stable constant current in CC charging phase, where the charging current is fixed to 1.75 A.Although a voltage increase in CV phase is observed, the charger circuit is able to decrease the charging current to 0.5 A in CV phase, as depicted in battery data-sheet.The efficiency of the charger is figured out to be in the range of 86%-93% in the first setup, while it is found to be in the range of 78%-88% in the second setup,where a high frequency transformer is employed. 展开更多
关键词 Resonant converter Parallel resonant converter Battery charger constant-current constant-voltage(CC-CV)charging
原文传递
Dynamics and stabilization of peak current-mode controlled buck converter with constant current load 被引量:3
3
作者 冷敏瑞 周国华 +1 位作者 张凯暾 李振华 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第10期101-109,共9页
The discrete iterative map model of peak current-mode controlled buck converter with constant current load(CCL),containing the output voltage feedback and ramp compensation, is established in this paper. Based on th... The discrete iterative map model of peak current-mode controlled buck converter with constant current load(CCL),containing the output voltage feedback and ramp compensation, is established in this paper. Based on this model the complex dynamics of this converter is investigated by analyzing bifurcation diagrams and the Lyapunov exponent spectrum. The effects of ramp compensation and output voltage feedback on the stability of the converter are investigated. Experimental results verify the simulation and theoretical analysis. The stability boundary and chaos boundary are obtained under the theoretical conditions of period-doubling bifurcation and border collision. It is found that there are four operation regions in the peak current-mode controlled buck converter with CCL due to period-doubling bifurcation and border-collision bifurcation. Research results indicate that ramp compensation can extend the stable operation range and transfer the operating mode, and output voltage feedback can eventually eliminate the coexisting fast-slow scale instability. 展开更多
关键词 buck converter constant current load discrete iterative map model ramp compensation
下载PDF
Field-induced phase transitions in chiral smectic liquid crystals studied by the constant current method
4
作者 H Dhaouadi R Zgueb +2 位作者 O Riahi F Trabelsi T Othman 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第5期373-379,共7页
In ferroelectric liquid crystals, phase transitions can be induced by an electric field. The current constant method allows these transition to be quickly localized and thus the(E, T) phase diagram of the studied pr... In ferroelectric liquid crystals, phase transitions can be induced by an electric field. The current constant method allows these transition to be quickly localized and thus the(E, T) phase diagram of the studied product can be obtained.In this work, we make a slight modification to the measurement principles based on this method. This modification allows the characteristic parameters of ferroelectric liquid crystal to be quantitatively measured. The use of a current square signal highlights a phenomenon of ferroelectric hysteresis with remnant polarization at null field, which points out an effect of memory in this compound. 展开更多
关键词 chiral smectic liquid crystal constant current method ferroelectric polarization dielectric permittivity
下载PDF
Multi-stage constant current charging strategy considering SOC intervals and voltage thresholds
5
作者 Yu Zhang Si Xu Tiezhou Wu 《Global Energy Interconnection》 EI CAS CSCD 2022年第2期143-153,共11页
Conventional multi-stage constant current charging strategies often use higher multiples of current to charge the battery in pursuit of shorter charging times.However,this leads to an increase in battery temperature,w... Conventional multi-stage constant current charging strategies often use higher multiples of current to charge the battery in pursuit of shorter charging times.However,this leads to an increase in battery temperature,while shortening the charging time.This in turn affects the safety of the charging process.Furthermore,the higher charging currents are not ideal for shortening the charging time in the later stages of charging.To solve the aforementioned problems,in this study,a multi-stage constant current charging strategy is presented.This strategy can shorten the battery charging time by using the increase in battery temperature during the charging process as a constraint,using a genetic algorithm to calculate the charging current value,and investigating the phased approach to charging.Finally,the charging strategy is experimentally validated at different ambient temperatures and different initial SOCs.The experimental results show that the charging strategy proposed in this paper not only reduces the amount of calculations,but also reduces the temperature rise by up to 46.4%and charging time by up to 4.2%under different operating conditions. 展开更多
关键词 Charging time Battery temperature rise Genetic algorithm Multi-stage constant current charging
下载PDF
Non-inverting buck-boost DC-DC converter based on constant inductor current control
6
作者 Yao Suyi Jiang Jianguo 《Journal of Southeast University(English Edition)》 EI CAS 2021年第2期171-176,共6页
The hysteresis control combined with PWM control non-inverting buck-boost was proposed to improve the light load efficiency and power density.The constant inductor current control(CICC)was established to mitigate the ... The hysteresis control combined with PWM control non-inverting buck-boost was proposed to improve the light load efficiency and power density.The constant inductor current control(CICC)was established to mitigate the dependence on the external components and device variation and make smooth transition between hysteresis control loop and pulse width modulation(PWM)control loop.The small signal model was deduced for the buck and boost operation mode.The inductor current slope control(ICSC)was proposed to implement the automatic mode transition between buck and boost mode in one switching cycle.The results show that the converter prototype has good dynamic response capability,achieving 94%efficiency and 95%peak efficiency at full 10 A load current. 展开更多
关键词 four switch buck-boost converter inductor current slope control constant inductor current control small signal model
下载PDF
An improved analysis method of constant-current charge/discharge curves and its application to nickel hydroxide electrode
7
作者 潘滔 王建明 +3 位作者 陈惠 赵彦琳 肖慧明 张鉴清 《中国有色金属学会会刊:英文版》 CSCD 2003年第2期462-466,共5页
The derivative of charge and discharge curves (d t /d E vs E plot) can be used to describe the charge and discharge process more exactly. The d t /d E ? 獷 plots of nickel hydroxide electrode at different charge/disch... The derivative of charge and discharge curves (d t /d E vs E plot) can be used to describe the charge and discharge process more exactly. The d t /d E ? 獷 plots of nickel hydroxide electrode at different charge/discharge rates and intermittent discharge experiment are discussed. Though the d t /d E ? 獷 plot is affected by many factors, it clearly has intrinsic relation with the nature of active material such as conductivity and thermodynamic potential of active material, which changes with the state of charge. The d t /d E—E plot can also be applied to other electrochemical active materials, especially to those having several phases during charge or discharge. 展开更多
关键词 镍氢电池 电极 分析方法 改进 放电曲线
下载PDF
Low voltage substrate current: a monitor for interface states generation in ultra-thin oxide n-MOSFETs under constant voltage stresses
8
作者 王彦刚 许铭真 谭长华 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第11期3502-3506,共5页
The low voltage substrate current (Ib) has been studied based on generation kinetics and used as a monitor of interface states (Nit) generation for ultra-thin oxide n-MOSFETs under constant voltage stress. It is f... The low voltage substrate current (Ib) has been studied based on generation kinetics and used as a monitor of interface states (Nit) generation for ultra-thin oxide n-MOSFETs under constant voltage stress. It is found that the low voltage Ib is formed by electrons tunnelling through interface states, and the variations of Ib(△Ib) are proportional to variations of Nit (△Nit). The Nit energy distributions were determined by differentiating Nit(Vg). The results have been compared with that measured by using gate diode technique. 展开更多
关键词 interface states substrate current ultra-thin oxide constant voltage stress
下载PDF
Numerical Solution of MHD Convection and Mass Transfer Flow of Viscous Incompressible Fluid about an Inclined Plate with Hall Current and Constant Heat Flux
9
作者 Mohammad Wahiduzzaman Runu Biswas +2 位作者 Md. Eaqub Ali Md. Shakhaoath Khan Ifsana Karim 《Journal of Applied Mathematics and Physics》 2015年第12期1688-1709,共22页
The present numerically study investigates the influence of the Hall current and constant heat flux on the Magneto hydrodynamic (MHD) natural convection boundary layer viscous incompressible fluid flow in the manifest... The present numerically study investigates the influence of the Hall current and constant heat flux on the Magneto hydrodynamic (MHD) natural convection boundary layer viscous incompressible fluid flow in the manifestation of transverse magnetic field near an inclined vertical permeable flat plate. It is assumed that the induced magnetic field is negligible compared with the imposed magnetic field. The governing boundary layer equations have been transferred into non-similar model by implementing similarity approaches. The physical dimensionless parameter has been set up into the model as Prandtl number, Eckert number, Magnetic parameter, Schmidt number, local Grashof number and local modified Grashof number. The numerical method of Nactsheim-Swigert shooting iteration technique together with Runge-Kutta six order iteration scheme has been used to solve the system of governing non-similar equations. The physical effects of the various parameters on dimensionless primary velocity profile, secondary velocity profile, and temperature and concentration profile are discussed graphically. Moreover, the local skin friction coefficient, the local Nusselt number and Sherwood number are shown in tabular form for various values of the parameters. 展开更多
关键词 MHD HEAT and Mass Transfer HALL current Inclined Plate constant HEAT FLUX
下载PDF
An Adaptive Response Compensation Technique for the Constant-Current Hot-Wire Anemometer
10
作者 Soe Minn Khine Tomoya Houra Masato Tagawa 《Open Journal of Fluid Dynamics》 2013年第2期95-108,共14页
An adaptive response compensation technique has been proposed to compensate for the response lag of the constant-current hot-wire anemometer (CCA) by taking advantage of digital signal processing technology. First, we... An adaptive response compensation technique has been proposed to compensate for the response lag of the constant-current hot-wire anemometer (CCA) by taking advantage of digital signal processing technology. First, we have developed a simple response compensation scheme based on a precise theoretical expression for the frequency response of the CCA (Kaifuku et al. 2010, 2011), and verified its effectiveness experimentally for hot-wires of 5 μm, 10 μm and 20 μm in diameter. Then, another novel technique based on a two-sensor probe technique—originally developed for the response compensation of fine-wire thermocouples (Tagawa and Ohta 1997;Tagawa et al. 1998)—has been proposed for estimating thermal time-constants of hot-wires to realize the in-situ response compensation of the CCA. To demonstrate the usefulness of the CCA, we have applied the response compensation schemes to multipoint velocity measure- ment of a turbulent wake flow formed behind a circular cylinder by using a CCA probe consisting of 16 hot-wires, which were driven simultaneously by a very simple constant-current circuit. As a result, the proposed response compensation techniques for the CCA work quite successfully and are capable of improving the response speed of the CCA to obtain reliable measurements comparable to those by the commercially-available constant-temperature hot-wire anemometer (CTA). 展开更多
关键词 Flow Measurement HOT-WIRE ANEMOMETER Turbulent Flow constant-current HOT-WIRE ANEMOMETER Response COMPENSATION Frequency Response Time-constant Multipoint Measurement Digital Signal Processing
下载PDF
Constant Ripple Current Control for Switching DC-DC Converter
11
作者 Gwo-Tarng Chern Jenn-Jong Shieh 《Journal of Energy and Power Engineering》 2012年第9期1437-1441,共5页
The adapted DC-DC converters should be smaller in size and have a small output current ripple to meet the increasing demand for low voltages with high performance and high density micro processors for several microele... The adapted DC-DC converters should be smaller in size and have a small output current ripple to meet the increasing demand for low voltages with high performance and high density micro processors for several microelectronic load applications. This paper proposes a DC-DC converter using variable on-time and variable switching frequency control enhanced constant ripple current control and reduced magnetic components. The proposed converter is realized by making the turn-offtime proportional to the on-time of the converter, according to the input and output voltage, thereby reducing the corresponding current ripple on output voltage in the continuous conduction mode. A Buck DC-DC converter using the proposed control strategy is analyzed in detail, along with some experimental results to show the performance and effectiveness of this converter. 展开更多
关键词 constant ripple current DC-DC converter variable switching frequency continuous conduction mode indirect currentsensor magnetic component.
下载PDF
表面活性剂对电镀锌-铟合金性能的影响
12
作者 邹忠利 李洋 +2 位作者 单玺畅 米志娟 张旭 《表面技术》 北大核心 2025年第2期137-147,共11页
目的研究表面活性剂十六烷基三甲基溴化铵(CTAB)与聚乙二醇2000(PEG)对Zn-In合金镀层性能的影响。方法采用单因素试验确定了CTAB与PEG的含量,使用响应曲面法建立耐蚀性能测试参数与表面活性剂含量之间的数学模型。实验采用线性电位扫描... 目的研究表面活性剂十六烷基三甲基溴化铵(CTAB)与聚乙二醇2000(PEG)对Zn-In合金镀层性能的影响。方法采用单因素试验确定了CTAB与PEG的含量,使用响应曲面法建立耐蚀性能测试参数与表面活性剂含量之间的数学模型。实验采用线性电位扫描,并采用维氏显微硬度仪,接触角测试仪、SEM、EDS和XRD对电镀锌-铟合金镀层的析氢行为、硬度、表面湿润性、表面形貌、元素种类以及物相组成进行表征。结果通过响应曲面法建立了耐腐蚀性能参数与CTAB和PEG含量之间的数学模型,获得复合表面活性剂组成,镀层的耐蚀性良好;接触角测试结果显示,未加添加剂的膜层表面湿润角为56°,优化后镀层表面湿润角仅为25°,具有较好的亲水性,且由于晶粒细化使试样硬度提升;镀层主要由Zn、In、C、O等元素组成,加入表面活性剂对镀层的影响不大,金属铟的生长晶面主要为(101)和(102)晶面。结论最佳添加复合表面活性剂的比例为CTAB0.33g/L,PEG0.87g/L,电镀液中添加表面活性剂后能够有效提升镀层耐腐蚀性能,有效抑制了析氢反应。 展开更多
关键词 Zn-In合金 表面活性剂 响应曲面法 恒电流沉积 耐蚀性
下载PDF
基于进化算法的锂离子电池充电策略优化
13
作者 钟英群 刘晶 郑培 《汽车实用技术》 2025年第1期13-19,共7页
为提高电池的性能,研究制定先进的充电策略至关重要。基于差分进化算法,文章提出了一种综合考虑电池寿命和充电效率的多级恒流充电策略。首先,结合锂离子电池外特性与内部机理,建立了电学模型、热学模型和寿命等耦合模型;其次,根据上述... 为提高电池的性能,研究制定先进的充电策略至关重要。基于差分进化算法,文章提出了一种综合考虑电池寿命和充电效率的多级恒流充电策略。首先,结合锂离子电池外特性与内部机理,建立了电学模型、热学模型和寿命等耦合模型;其次,根据上述耦合模型参数,进一步构造以使用寿命和充电速度为目标的优化方程;最后,采用差分进化算法确定各恒流段的最优充电电流。制定满足消费者需求的安全快速充电策略,不仅有利于电动汽车的推广与普及,而且能够为国家长久可持续发展做出贡献。 展开更多
关键词 锂离子电池 多级恒流充电 耦合模型 进化算法 优化方程
下载PDF
具有功率因数校正的单相在线式不间断电源设计
14
作者 黄嘉乐 林润鑫 +1 位作者 林辉煌 陈国泰 《电子设计工程》 2025年第1期74-79,共6页
文中以STM32F103C8T6为主控芯片设计了单相在线式不间断电源。该电源由变压器、功率因数校正电路、Buck电路、Boost电路、逆变电路和储能装置等构成。市电经变压等电路以直流电对储能装置进行恒流充电,而直流电也进入逆变电路产生所需... 文中以STM32F103C8T6为主控芯片设计了单相在线式不间断电源。该电源由变压器、功率因数校正电路、Buck电路、Boost电路、逆变电路和储能装置等构成。市电经变压等电路以直流电对储能装置进行恒流充电,而直流电也进入逆变电路产生所需的交流电为负载供电。当市电出现停电、过压或欠压的问题时,储能装置受控接入逆变电路,实现不间断电源供电。实验测试表明,系统具有输出电压有效值平均29.99 V,频率50.00 Hz下的总谐波失真不超过2.7%,交流输入时负载调整率1.60%,电压调整率3.69%,直流输入时电源输出效率约89.90%。此外,系统可以通过按键步进设置充电电流。 展开更多
关键词 STM32 功率因数校正 不间断电源 恒流充电
下载PDF
Neural network prediction of the shunt current in resistance spot welding
15
作者 张勇 谢红霞 +3 位作者 滕辉 白华 鄢君辉 汪帅兵 《China Welding》 EI CAS 2013年第3期73-78,共6页
An error back propagation (BP) neural network prediction model was established for the shunt current compensation in series resistance spot welding. The input variables for the neural network consist of the resistiv... An error back propagation (BP) neural network prediction model was established for the shunt current compensation in series resistance spot welding. The input variables for the neural network consist of the resistivity of the material, the thickness of workpiece and the spot spacing, and the shunt rate is outputted. A simplified calculation for the shunt rate was presented based on the feature of the constant-current resistance spot welding and the variation of the resistance in resistance spot welding process, and then the data generated by simplified calculation were used to train and adjust the neural network model. The neural network model proposed was used to predict the shunt rate in the spot welding of 20# mlid steel (in Chinese classification) (in 2. 0 mm thickness) and 10# mild steel (in 1.5 mm and 1.0 mm thickness). The maximum relative prediction errors are, respectively, 2. 83%, 1.77% and 3.67%. Shunt current compensation experiments were peoCormed based on the neural network prediction model proposed to check the diameter difference of nuggets. Experimental results show that maximum nugget diameter deviation is less than 4% for both 10# and 20# mlid steels with spot spacing of 30 mm and 50 mm. 展开更多
关键词 resistance spot welding constant current control shunt current neural network prediction model NUGGET
下载PDF
STUDY OF HIGH-STABILITY CURRENT REGULATORS FOR CURRENT FROM 0.1A TO 8A
16
作者 吕品桢 范雅俊 +3 位作者 洪云翔 吴荣权 徐信业 魏海波 《Journal of Electronics(China)》 1995年第1期90-96,共7页
Improving the temperature stability and widening the constant current range are two important problems to be solved in the application of the current regulators. This paper introduces a modular approach for the design... Improving the temperature stability and widening the constant current range are two important problems to be solved in the application of the current regulators. This paper introduces a modular approach for the design of the current regulator with a very wide current range. The test results show that their output current ranges from 0.1A to 8A, with its current temperature coefficient as low as 10-4/℃ to 10-5/℃ and limiting voltage lower than 0.4V. 展开更多
关键词 current REGULATOR constant-current circuit Module current temperature COEFFICIENT Limiting-voltage
下载PDF
基于频率切换实现恒流/恒压输出的电场耦合无线电能传输系统 被引量:1
17
作者 苏玉刚 颜志琼 +3 位作者 胡宏晟 孙跃 刘哲 刘书柏杨 《中国电机工程学报》 EI CSCD 北大核心 2024年第4期1553-1564,I0025,共13页
电场耦合无线电能传输(electric-field coupled wireless power transfer,EC-WPT)技术的实际应用中,有些用电设备需要系统具有不同的恒定输出特性(恒流/恒压),即系统输出电压或输出电流与负载解耦,此外,系统还需具备在恒流、恒压模式间... 电场耦合无线电能传输(electric-field coupled wireless power transfer,EC-WPT)技术的实际应用中,有些用电设备需要系统具有不同的恒定输出特性(恒流/恒压),即系统输出电压或输出电流与负载解耦,此外,系统还需具备在恒流、恒压模式间按需切换的功能。针对该需求,基于LC-CLC谐振网络提出1种具有恒流/恒压输出特性的EC-WPT系统,分析LC-CLC谐振网络特性,推导恒流/恒压输出特性的实现条件以及恒流频率和恒压频率的计算方法,并给出系统参数设计方法,分析系统对工作频率的敏感性。最后通过仿真和实验验证所提出的EC-WPT系统恒流/恒压输出特性及其参数设计方法的正确性和有效性。实验结果表明所提出的系统在输入电压恒定的不同负载工况下分别实现2 A的恒流输出以及96 V的恒压输出,其最大传输效率分别为87.83%及88.17%。 展开更多
关键词 电场耦合无线电能传输系统 频率切换 恒流 恒压 谐振网络
下载PDF
A Novel Over-Current Protection Technique Applied to Peak-Current Type DC-DC Converter
18
作者 Yu Fang Tengfei Wei +2 位作者 Liang He Yong Xie Yan Xing 《Journal of Electromagnetic Analysis and Applications》 2010年第6期352-356,共5页
The change of the over-current protection point of the power switches, caused by slope compensation, is analyzed in detail. It is discovered that the peak current protecting value increases as the duty cycle decreases... The change of the over-current protection point of the power switches, caused by slope compensation, is analyzed in detail. It is discovered that the peak current protecting value increases as the duty cycle decreases. As a result, the safety operation of the switches is damaged greatly. A novel solution to improve over-current protection with constant peak current limitation is proposed by inducing synchronous slope compensation into the current limit function instead of the original constant voltage. The design principle and method of the protection circuit based on a UC3846 PWM controller for the interleaved dual-forward converter is presented. Experimental results are given to verify the analysis. 展开更多
关键词 DC-DC CONVERTER Peak-current Control constant Peak-current LIMITING
下载PDF
恒流源三侧向电阻率测井模块研制及应用 被引量:2
19
作者 冯延强 刘富强 +2 位作者 布和 于怀远 邵帅 《世界核地质科学》 CAS 2024年第1期23-32,共10页
为进一步提高砂岩型铀矿地层电阻率参数在测井解释中的应用效果,尤其是对泥砂泥交互薄层的精细测量与识别,研究了基于OPA547放大器的恒流源三侧向电阻率测井模块,通过设计以OPA547为恒流激励源的数字激励控制电路,实现了正弦激励信号的... 为进一步提高砂岩型铀矿地层电阻率参数在测井解释中的应用效果,尤其是对泥砂泥交互薄层的精细测量与识别,研究了基于OPA547放大器的恒流源三侧向电阻率测井模块,通过设计以OPA547为恒流激励源的数字激励控制电路,实现了正弦激励信号的恒流输出;设计了正弦检测信号的恒流反馈电路,实现恒流源的负反馈稳定输出;设计了交流电压检测电路,实现了交流信号的低通滤波与信号半波整流;最后,在实验室利用标准刻度器进行了研制模块的系数刻度,且在砂岩型铀矿钻孔进行了实际测井应用对比。经对比分析,研制的恒流源三侧向电阻率测井模块能够与砂岩铀矿综合测井中的其他参数组合使用,输出激励电流可调,对岩性及岩性界面具有较高的识别能力,对于交互薄层、钙质夹层等地层岩性变化的响应显示明显。 展开更多
关键词 恒流源 三侧向电阻率 OPA547 地球物理测井
下载PDF
基于变频重构S/SP拓扑的无线电能传输系统恒流恒压研究
20
作者 李中启 张晨曦 +2 位作者 王建斌 王忠美 黄守道 《电工技术学报》 EI CSCD 北大核心 2024年第15期4718-4732,共15页
针对电动汽车无线充电系统耦合系数和负载变化导致系统输出电流和电压剧烈波动的问题,提出一种由交错叠放式线圈结构和变频重构控制策略组成的无线电能传输系统,通过重构补偿拓扑,并切换工作频率,实现了系统的恒流恒压输出。首先,分析... 针对电动汽车无线充电系统耦合系数和负载变化导致系统输出电流和电压剧烈波动的问题,提出一种由交错叠放式线圈结构和变频重构控制策略组成的无线电能传输系统,通过重构补偿拓扑,并切换工作频率,实现了系统的恒流恒压输出。首先,分析了拓扑重构前后系统的恒流、恒压输出特性和零相角特性,对比恒流恒压工作模式下补偿电容的大小,给出了系统参数调整方法。其次,剖析了交错叠放式线圈结构模型,提出基于耦合系数波动最小原则的线圈结构优化策略。所提出的系统补偿元件较少,两个工作频率点符合国际标准。最后,搭建一套500 W的实验样机,验证系统的可行性和有效性。实验结果表明,交错叠放式线圈在X轴方向偏移发射线圈外径的55%(187mm)或Y轴方向偏移120mm时,耦合系数波动率小于5%。系统在恒流模式下电流波动率为3.58%,在恒压模式下电压波动率为4.83%,满足无线充电系统恒流恒压需求。 展开更多
关键词 无线电能传输 变频重构 恒流 恒压 零相角
下载PDF
上一页 1 2 149 下一页 到第
使用帮助 返回顶部