期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Current-Controlled CFTA Based Fractional Order Quadrature Oscillators
1
作者 Tada Comedang Pattana Intani 《Circuits and Systems》 2016年第13期4201-4212,共12页
This paper presents a study of fractional order quadrature oscillators based on current-controlled current follower transconductance amplifiers (CCCFTA). The design realisation and performance of the fractional order ... This paper presents a study of fractional order quadrature oscillators based on current-controlled current follower transconductance amplifiers (CCCFTA). The design realisation and performance of the fractional order quadrature oscillators have been presented. The quadrature oscillators are constructed using three fractional capacitors of orders α = 0.5. The fractional capacitor is not available on the market or in the PSPICE program. Fortunately, the fractional capacitor can be realised by using the approximate method for the RC ladder network approximation. The oscillation frequency and oscillation condition can be electronically/orthogonally controlled via input bias currents. Due to high-output impedances, the proposed circuit enables easy cascading in current-mode (CM). The PSPICE simulation results are depicted, and the given results agree well with the anticipated theoretical outcomes. 展开更多
关键词 Fractional Order Quadrature Oscillator current-Controlled current follower Transconductance Amplifier
下载PDF
The current situation of hepatitis following blood transfusion in Harbin
2
《中国输血杂志》 CAS CSCD 2001年第S1期394-,共1页
关键词 The current situation of hepatitis following blood transfusion in Harbin
下载PDF
多次雷电冲击对氧化锌避雷器阀片性能的影响(英文) 被引量:14
3
作者 Haryono T Sirait K T +1 位作者 Tumiran Hamzah Berahim 《高电压技术》 EI CAS CSCD 北大核心 2011年第11期2763-2771,共9页
A lightning arrester is used for electrical equipment protection against damage due to lightning strikes.One example of protected electrical equipment is electrical power transformer.If there is no lightning arrester ... A lightning arrester is used for electrical equipment protection against damage due to lightning strikes.One example of protected electrical equipment is electrical power transformer.If there is no lightning arrester installed to the transformer,when a lightning strike happens,it may receive a very high lightning overvoltage,which is certainly resulted in the transformer damage at its insulation.Usually,a lightning arrester specification data attached to a lightning arrester contains the rating data of the lightning arrester current and voltage.In the use of lightning arrester,the possibility of receiving multiple lightning strikes is not taken into account sometimes.In fact,in some places,the number of multiple strikes in short duration is quiet high in number.This condition makes the lightning arrester being stroked by multiple lightning strikes.Therefore,it may change the lightning arrester's properties,and then the arrester may not be able to provide good electrical equipment protection against lightning strike anymore.This condition will result in great loss to electrical companies and electrical consumers.Therefore,this research studied the effect of applying multiple lightning strikes to ZnO lightning arrester block.Every time a group of lightning impulse current is applied to the ZnO lightning arrester block,it is followed by the measuring of its 50 Hz voltage and current characteristic. The changing in the ZnO lightning arrester block 50 Hz characteristic then can be analyzed.It was found that by applying more numbers of lightning strikes which made the arrester becoming worse,even though,actually,the lightning impulse peak current was still under the rating of the lightning arrester current.In this case for a 5 kA,24 kV lightning arrester,even though the lightning impulse peak current flowing through the ZnO lightning arrester block was still 2500 A,the lightning arrester ZnO block had already been damaged.Having been damaged,an alternating current flowing through the damaged ZnO block was about 10000 times as much current flowing to the good one.The maximum of impulse energy absorbed by a ZnO block recorded was 334.7 J/cm^3.The damaged ZnO block should be replaced by a good one. 展开更多
关键词 follow current impulse current lightning arrester lightning strike multiple impulse current ZnO block
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部