期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Current Sharing Temperature Test and Simulation with GANDALF Code for ITER PF2 Conductor Sample 被引量:3
1
作者 李少磊 武玉 +1 位作者 刘勃 翁佩德 《Plasma Science and Technology》 SCIE EI CAS CSCD 2011年第5期627-630,共4页
Cable-in-conduit conductor (CICC) conductor sample of the PF2 coil for ITER was tested in the SULTAN facility. According to the test results, the CICC conductor sample exhibited a stable performance regarding the cu... Cable-in-conduit conductor (CICC) conductor sample of the PF2 coil for ITER was tested in the SULTAN facility. According to the test results, the CICC conductor sample exhibited a stable performance regarding the current sharing temperature. Under the typical operational conditions of a current of 45 kA, a magnetic field of 4 T and a temperature of 5 K for PF2, the test result for the conductor current sharing temperature is 6.71 K, with a temperature margin of 1.71 K. For a comparison thermal-hydraulic analysis of the PF2 conductor was carried out using GANDALF code in a 1-D model, and the result is consistent with the test one. 展开更多
关键词 current sharing temperature poloidal field cable-in-conduit conductor NbTistrand GANDALF
下载PDF
Current Sharing Analysis of Arm Prototype for ITER PF Converter Bridge 被引量:2
2
作者 李金超 宋执权 +5 位作者 许留伟 傅鹏 郭斌 李森 董琳 王敏 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第3期283-287,共5页
A bridge arm prototype of ITER poloidal field (PF) converter modules has been designed and fabricated. Non-cophase counter parallel connection is chosen as the arm structure of the prototype. Among all factors affec... A bridge arm prototype of ITER poloidal field (PF) converter modules has been designed and fabricated. Non-cophase counter parallel connection is chosen as the arm structure of the prototype. Among all factors affecting current sharing, arm structure is the main one. During the design of the arm prototype, a novel method based on inductance matrixes is employed to improve the current sharing of the bridge arm. The test results on the prototype show that the current sharing performance of the arm prototype is much better than relevant design requirement, and that the matrix method is very effective to analyze and solve the current sharing problems of thyristor converters. 展开更多
关键词 thyristor converter current sharing electromagnetic analysis inductance ma-trix
下载PDF
An Improvement on Current Sharing Characteristics of Poloidal Field (PF) AC-DC Converters 被引量:1
3
作者 陈鹏 傅鹏 宋执权 《Plasma Science and Technology》 SCIE EI CAS CSCD 2011年第4期497-501,共5页
In response to the current imbalance phenomenon and its harmfulness, a current sharing circuit model is built up, which reveals the underlying causes for the current imbalance through a quantitative analysis. Then, a ... In response to the current imbalance phenomenon and its harmfulness, a current sharing circuit model is built up, which reveals the underlying causes for the current imbalance through a quantitative analysis. Then, a feasible approach of improvement, namely enlargement of the length of connection busbars, is proposed. After the amendment, it can be seen that the current sharing coefficient is ahnost unity under rated or fault current conditions. 展开更多
关键词 current sharing circuit model the length of connection busbars current imbalanced coefficient
下载PDF
Proportional Current Sharing Based on Periodic Dynamic Event-driven H_(∞) Consensus in DC Microgrids with Power Coupling
4
作者 Rui Wang Qiuye Sun +3 位作者 Lei Liu Li Zhang Peng Wang Huaguang Zhang 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2022年第6期1558-1568,共11页
Although the proportional current sharing has been widely studied,the heterogeneous characteristic of the different interfaced converters and power coupling terms among distributed generators(DGs)are rarely considered... Although the proportional current sharing has been widely studied,the heterogeneous characteristic of the different interfaced converters and power coupling terms among distributed generators(DGs)are rarely considered.Therefore,this paper proposes a secondary H_(∞)consensus method with a periodic dynamic event-driven scheme for dc microgrids with power coupling to accomplish the precise proportional current-sharing.It is useful for reducing carbon.First,a generalized converter is constructed through equivalent transformation between rectifier and boost converter.Moreover,the heterogeneous characteristic of the interfaced converters regarding different DGs,such as wind and solar generators,is embedded into controller design.Furthermore,the standard linear heterogeneous multi-agent system with power coupling term is built.On this basis,the problem of proportional current sharing is modified into the output consistency problem of multi-agent systems.Furthermore,the H_(∞)consensus approach is proposed to accomplish the precise proportional current sharing.Meanwhile,to shorten communication bandwidth,the periodic dynamic event-driven communication strategy is designed.Compared with traditional event-driven communication schemes,a lower communication frequency has been obtained through the proposed communication scheme.In addition,this communication scheme not only avoids Zeno-behavior,but also acquires the smallest sampling time interval.Finally,effectiveness of the proposed approach is verified by two test systems. 展开更多
关键词 current sharing event-driven communication H_(∞)consensus approach heterogeneous distributed generators
原文传递
Input-parallel output-parallel configuration of boost half bridge DC-DC converter with control strategy
5
作者 SOOMRO Amir Mahmood KHAHRO Shahnawaz Farhan +2 位作者 KHASKHELI Murad Ali 廖晓钟 FARHAN Manzoor 《Journal of Beijing Institute of Technology》 EI CAS 2014年第1期47-52,共6页
The concept of connecting two boost half bridge DC-DC converter modules in input-paral- lel output-parallel configuration is presented. The input-parallel-output-parallel (IPOP) converter consists of multiple boost ... The concept of connecting two boost half bridge DC-DC converter modules in input-paral- lel output-parallel configuration is presented. The input-parallel-output-parallel (IPOP) converter consists of multiple boost half bridge (BHB) DC-DC converter modules which are connected in par- allel at the input and output side. This kind of converter is an attractive solution for high power ap- plications. The correlation between input current sharing (ICS) and output current sharing (OCS) of the IPOP converter basic modules is described. Two loop control strategies, consisting of input cur- rent loop and output voltage loop, have been developed to achieve equal ICS and OCS in this present work. The control strategy for the IPOP configuration of boost haft bridge DC-DC converter has been verified for different load conditions (half load and full load), The IPOP system proposed here is comprising of two modules but it can be extended to three or more. The performance of the pro- posed system along with the control strategy is verified by simulation in MATLAB using Simpower tool. Finally the satisfactory simulation results are obtained. 展开更多
关键词 boost half bridge BHB input current sharing ICS input-parallel output-parallel(IPOP) output current sharing (OCS)
下载PDF
Test and Analysis of China's First Short Conductor Sample for ITER Toroidal Field Coils
6
作者 刘勃 武玉 《Plasma Science and Technology》 SCIE EI CAS CSCD 2011年第1期106-110,共5页
In the flamework of the ITER qualification tests, the first China TF conductor sample (CNTF1) was tested at the SULTAN facility. The sample was made of two TF conductor sections manufactured from identical internal ... In the flamework of the ITER qualification tests, the first China TF conductor sample (CNTF1) was tested at the SULTAN facility. The sample was made of two TF conductor sections manufactured from identical internal stannum strands provided by the Oxford ~upercon- cluctlng technology company (OST). In order to evaluate the conductor performance, the current sharing temperature (Tcs) was measured at specified electromagnetic load cycling steps. Both conductor sections of the CNTF1 sample showed identical performance. Tcs was 7.2 K before cycling loading, and 6.9 K even after 950 cycles, without significant degradation, which substan- tially exceeds the ITER requirement of 5.7 K. The tests of the CNTF1 conductor sample showed that the electromagnetic cyclic load exhibited a negligible effect on the conductor performance. The coupling time constant 0 for AC loss was 214 ms and 71.52 nrs before and after the cycling load. respectively. The test results of the sample are compared with the strand performance and parameter model analysis. 展开更多
关键词 current sharing temperature. ITER NbaSn TF conductor AC loss
下载PDF
Input series out putparallel based multi-modular boost half bridge DC-DC converter with a dynamic control scheme
7
作者 SOOMRO Amir Mahmood SYED Amjad Ali +2 位作者 KHIZER Arbab Nighat 廖晓钟 MANZOOR Muhammad Farhan 《Journal of Beijing Institute of Technology》 EI CAS 2014年第4期519-526,共8页
Multi-modular system plays an important role in power system architecture because low voltage and low power converters can be connected in any combination parallel or series at input/ output side in order to obtained ... Multi-modular system plays an important role in power system architecture because low voltage and low power converters can be connected in any combination parallel or series at input/ output side in order to obtained any given power system specifications. Multi-modular boost haft bridge DC-DC converter in the configuration of input series output parallel has been investigated in this paper. The boost half bridge DC-DC converters are connected in input series output parallel con- figuration in order to achieve equal input voltage sharing and output current sharing between the con- verters. This can be achieved with the help of dynamic control scheme which consists of two loops, a voltage loop and a current loop, for each module. Dynamic behavior of multi-modular converter configuration has been observe by varying the load condition. Moreover, the results obtained through multi-modular converter describe that the system has good dynamic and steady state response. Al- though two converter modules are focused in this paper but it can be modified to any number of modules. 展开更多
关键词 boost haft bridge BHB input series output parallel ISOP input voltage sharing(IVS) multi-modular output current sharing (OCS)
下载PDF
Decoupling Control Strategy for Single Phase SPWM Parallel Inverters
8
作者 Shun-Gang Xu Jian-Ping Xu Tai-Qiang Cao 《Journal of Electronic Science and Technology of China》 2009年第3期258-262,共5页
A deconpling control strategy of inverter parallel system is proposed based on the equivalent output impedance of single phase voltage source SPWM (sinusoidal pulse width modulation) inverter. The active power and r... A deconpling control strategy of inverter parallel system is proposed based on the equivalent output impedance of single phase voltage source SPWM (sinusoidal pulse width modulation) inverter. The active power and reactive power are calculated in terms of output voltage and current of the inverter, and sent to the other inverters in the parallel system via controller area network (CAN) bus. By calculating and decoupling the circumfluence of the active power and reactive power, the inverters can share load current via the regulation of the reference-signal phase and amplitude. Experimental results of an 110V/2kVA inverter parallel system show the feasibility of the decoupling control strategy. 展开更多
关键词 CAN bus current sharing INVERTERS parallel operation
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部