An input-output signal selection based on Phillips-Heffron model of a parallel high voltage alternative current/high voltage direct current(HVAC/HVDC) power system is presented to study power system stability. It is w...An input-output signal selection based on Phillips-Heffron model of a parallel high voltage alternative current/high voltage direct current(HVAC/HVDC) power system is presented to study power system stability. It is well known that appropriate coupling of inputs-outputs signals in the multivariable HVDC-HVAC system can improve the performance of designed supplemetary controller. In this work, different analysis techniques are used to measure controllability and observability of electromechanical oscillation mode. Also inputs–outputs interactions are considered and suggestions are drawn to select the best signal pair through the system inputs-outputs. In addition, a supplementary online adaptive controller for nonlinear HVDC to damp low frequency oscillations in a weakly connected system is proposed. The results obtained using MATLAB software show that the best output-input for damping controller design is rotor speed deviation as out put and phase angle of rectifier as in put. Also response of system equipped with adaptive damping controller based on HVDC system has appropriate performance when it is faced with faults and disturbance.展开更多
随着高压直流输电工程的不断投产,以及风电项目的增多,越来越多的风电场出现在电网换相换流器高压直流输电(line-commutated-converter based high voltage direct current,LCC-HVDC)受端换流站近区,两者构成的系统存在振荡风险。为此,...随着高压直流输电工程的不断投产,以及风电项目的增多,越来越多的风电场出现在电网换相换流器高压直流输电(line-commutated-converter based high voltage direct current,LCC-HVDC)受端换流站近区,两者构成的系统存在振荡风险。为此,该文针对直流受端馈入站与近区风电场系统的振荡特性展开研究。首先,建立并验证系统的状态空间模型,基于该模型计算出系统特征值,确定LCC-HVDC与风电场共同参与的振荡主导模式并进行参与因子分析。进一步地,通过对比是否接入LCC-HVDC的主导模式,得到LCC-HVDC的接入会削弱系统阻尼的结论。最后,从系统额定容量、交流系统短路比、风电场并网线路长度等方面探究系统稳定性的影响因素,并分析系统的不同短路比、潮流比对风机网侧换流器(grid-side converter,GSC)外环控制和换流站定电流控制器性能的影响。展开更多
文摘An input-output signal selection based on Phillips-Heffron model of a parallel high voltage alternative current/high voltage direct current(HVAC/HVDC) power system is presented to study power system stability. It is well known that appropriate coupling of inputs-outputs signals in the multivariable HVDC-HVAC system can improve the performance of designed supplemetary controller. In this work, different analysis techniques are used to measure controllability and observability of electromechanical oscillation mode. Also inputs–outputs interactions are considered and suggestions are drawn to select the best signal pair through the system inputs-outputs. In addition, a supplementary online adaptive controller for nonlinear HVDC to damp low frequency oscillations in a weakly connected system is proposed. The results obtained using MATLAB software show that the best output-input for damping controller design is rotor speed deviation as out put and phase angle of rectifier as in put. Also response of system equipped with adaptive damping controller based on HVDC system has appropriate performance when it is faced with faults and disturbance.
文摘随着高压直流输电工程的不断投产,以及风电项目的增多,越来越多的风电场出现在电网换相换流器高压直流输电(line-commutated-converter based high voltage direct current,LCC-HVDC)受端换流站近区,两者构成的系统存在振荡风险。为此,该文针对直流受端馈入站与近区风电场系统的振荡特性展开研究。首先,建立并验证系统的状态空间模型,基于该模型计算出系统特征值,确定LCC-HVDC与风电场共同参与的振荡主导模式并进行参与因子分析。进一步地,通过对比是否接入LCC-HVDC的主导模式,得到LCC-HVDC的接入会削弱系统阻尼的结论。最后,从系统额定容量、交流系统短路比、风电场并网线路长度等方面探究系统稳定性的影响因素,并分析系统的不同短路比、潮流比对风机网侧换流器(grid-side converter,GSC)外环控制和换流站定电流控制器性能的影响。