期刊文献+
共找到7,039篇文章
< 1 2 250 >
每页显示 20 50 100
Performance and Safety Improvement of Induction Motors based on Testing and Evaluation Standards
1
作者 Nkosinathi S.Khumalo Ntombizotwa P.Memane Udochukwu B.Akuru 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第3期310-318,共9页
The induction motor,which converts electrical energy into mechanical energy,has been recognized as the cornerstone of industrialization.The rotor of an induction motor can be either a squirrel cage rotor or a wound-ty... The induction motor,which converts electrical energy into mechanical energy,has been recognized as the cornerstone of industrialization.The rotor of an induction motor can be either a squirrel cage rotor or a wound-type rotor,both existing as magnetless topologies.Three-phase squirrel cage induction motors are frequently utilized in industrial drives because they are dependable,have high starting torque,are selfstarting and affordable.Single-phase induction motors,on the other hand,are commonly used for small loads such as domestic appliances in form of modest fans,pumps and electric power tools.In South Africa,there have been reports of fires and explosions resulting in live and property loss because of induction motors that have not been thoroughly tested or are incorrectly labelled in terms of ratings,electrical safety and performance.The goal of this study is targeted at preventing end-user injuries and failures caused by non-compliant induction motors,by evaluating locally manufactured/imported induction motors based on tests and evaluation from standards(IEC and SANS).The study is conducted using experimental procedures at the Explosion Prevention Technology and Rotating Machines(EPT and RM)laboratory,South African Bureau of Standards(SABS),South Africa.The main finding from the study shows differences in the nameplate characteristics of various induction motors which could have detrimental effects such as production and operational downtime in their end-use industries,at later stages. 展开更多
关键词 COMPLIANCE Induction motors International Electro-Technical standards(IEC) NAMEPLATE Experimental tests South African National standards(SANS)
下载PDF
Analysis of Standards Establishment for the Testing of Electrical Appliances
2
作者 Xiaobin Xie 《Journal of Electronic Research and Application》 2024年第2期12-17,共6页
As science and technology continue to develop,power equipment has become an indispensable part of industrial production and daily life.Whether it is the precise automation machinery utilized on production lines or the... As science and technology continue to develop,power equipment has become an indispensable part of industrial production and daily life.Whether it is the precise automation machinery utilized on production lines or the convenient electrical appliances found in households,their functionality relies heavily on electrical technology.Nonetheless,without stringent safety and performance assurances,these devices could potentially endanger lives and property.Thus,this paper explores the development strategy for establishing a standardized system within the electrical testing service industry,aiming to ensure safety and reliability. 展开更多
关键词 Electrical testing The service industry standard system construction
下载PDF
Comparison of RFFIT Tests with Different Standard Sera and Testing Procedures 被引量:6
3
作者 Peng-cheng Yu Akira Noguchi +3 位作者 Satoshi Inoue Qing Tang Simon Rayner Guo-dong Liang 《Virologica Sinica》 CAS CSCD 2012年第3期187-193,共7页
The World Health Organization (WHO) standard assay for determining antibody level is the rapid fluorescent focus inhibition test (RFFIT) and is used to determine the degree of immunity after vaccination against ra... The World Health Organization (WHO) standard assay for determining antibody level is the rapid fluorescent focus inhibition test (RFFIT) and is used to determine the degree of immunity after vaccination against rabies. To compare the difference in RFFIT results between the laboratories of The National Institute of Infectious Disease in Japan (NIID) and the Chinese Centre for Disease Control (CCDC) as well the influence of the choice of standard serum (STD) for the detection, the two laboratories detection methods were simultaneously manipulated by RFFIT. The reference serums used in NIID and the WHO standard serum used in CCDC were compared in the same RFFIT detection to determine the titer of four sera samples C1, Sl, S2 and S4 in parallel, and the titers of the detected sera samples were calculated using the standard formula for neutralizing antibody titer. No significant difference was found in RFFIT methods from the two laboratories and the RFFIT testing procedures of the two laboratories have good consistency. However, different titers were obtained with the tentative internal standard serum (TI-STD) produced by adjusting to 2.0 IU of WHO standard serum in NIID and the WHO STD. The titer determined with the TI-STD was higher than that determined with WHO STD, This difference appears to be significant and requires further investigation 展开更多
关键词 Rapid fluorescent focus inhibition test (RFFIT) standard serum Neutralizing antibody TITER
下载PDF
Field Load Test Based SHM System Safety Standard Determination for Rigid Frame Bridge
4
作者 Xilong Zheng Qiong Wang Di Guan 《Structural Durability & Health Monitoring》 EI 2024年第3期361-376,共16页
The deteriorated continuous rigid frame bridge is strengthened by external prestressing. Static loading tests wereconducted before and after the bridge rehabilitation to verify the effectiveness of the rehabilitation ... The deteriorated continuous rigid frame bridge is strengthened by external prestressing. Static loading tests wereconducted before and after the bridge rehabilitation to verify the effectiveness of the rehabilitation process. Thestiffness of the repaired bridge is improved, and the maximum deflection of the load test is reduced from 37.9 to27.6 mm. A bridge health monitoring system is installed after the bridge is reinforced. To achieve an easy assessmentof the bridge’s safety status by directly using transferred data, a real-time safety warning system is createdbased on a five-level safety standard. The threshold for each safety level will be determined by theoretical calculationsand the outcomes of static loading tests. The highest risk threshold will be set at the ultimate limit statevalue. The remaining levels, namely middle risk, low risk, and very low risk, will be determined usingreduction coefficients of 0.95, 0.9, and 0.8, respectively. 展开更多
关键词 Continuous rigid frame bridge REHABILITATION long-term monitoring field load test safety standard determination
下载PDF
Inspection and testing stressed in standards comparison and compliance action
5
《China Standardization》 2019年第3期7-7,共1页
The symposium on inspection and testing bodies in the special action on standards comparison and complianee of 10,000 enterprises of 1,000 sectors in 100 cities was held in Beijing on April 16,which was attended by mo... The symposium on inspection and testing bodies in the special action on standards comparison and complianee of 10,000 enterprises of 1,000 sectors in 100 cities was held in Beijing on April 16,which was attended by more than 70 representatives from SAMR and inspection and testing bodies. 展开更多
关键词 INSPECTION testing standardS COMPARISON
下载PDF
Application of Using Standard Equipment for Dental Scaler Tip Testing according to ISO 18397
6
作者 Chompoonoot Hirunyapruk Tassanai Sanponpute 《Journal of Mechanics Engineering and Automation》 2020年第2期52-59,共8页
The objective of this work was to study the use of standard equipment in amplitude and frequency tests of dental scaler tip according to ISO 18397.Four types of standard equipment:a laser displacement sensor,a microsc... The objective of this work was to study the use of standard equipment in amplitude and frequency tests of dental scaler tip according to ISO 18397.Four types of standard equipment:a laser displacement sensor,a microscope,a tachometer,and an ultrasonic frequency meter,were experimentally investigated to test a tip.The standard laser displacement sensor and the standard microscope were used to test the unloaded amplitude of the scaler tip.It was found that two types of standard equipment were able to measure the unloaded amplitude of the tip.The standard microscope was also employed for the loaded amplitude test.This test was performed by pressing the scaler tip with a load of 1 N,which was measured by a load cell set.The peak-to-peak amplitude found from the test was 116.7 m.The frequency test of the scaler tip was conducted using the standard laser displacement sensor,the tachometer and the ultrasonic frequency meter.All three types of standard equipment were found to be able to test the frequency of the tip without cooling liquid.Nevertheless,only the standard tachometer was capable of measuring the frequency of the tip with cooling liquid applied. 展开更多
关键词 Dental scaler tip ISO 18397 testing standard equipment
下载PDF
Overview of Standardized Testing System for ESL Students in U.S. Kindergarten Thru Grade 12 Public Schools
7
作者 Volkan Cicek 《Sino-US English Teaching》 2011年第12期773-786,共14页
A comprehensive overview of standardized testing system for ESL (English as a Second Language) students in U.S kindergarten thru grade 12 public school system is reviewed within the context of basis on federal and s... A comprehensive overview of standardized testing system for ESL (English as a Second Language) students in U.S kindergarten thru grade 12 public school system is reviewed within the context of basis on federal and state laws, as well as instructional basis. Identification process of LEP (Limited English Proficient) students via nomination, testing and testing criteria to be identified as LEP, hence ESL if placed in the program is defined in detail Standardized testing process of these students based on the federal AYP (Adequate Yearly Progress) measures through regular state standardized tests depending on three types of instructional program that LEP student is placed in the school that are Bilingual Education Program, ESL Program, and Two-Way Immersion Dual Language Programs are described. Standardized testing process of these students based on the federal AYP measures through other means if exempted from regular state standardized tests such as LAT (Linguistically Accommodated Testing) and the conditions to be exempted are discussed in detail. Holistically rated English Language Proficiency Assessments that are implemented to fulfill federal AMAOs (Annual Measurable Achievement Objectives) measures are defined briefly. Physical features of LAT test as well as direct and indirect accommodations for LAT reading, mathematics and science tests are defined via the accommodation needed and the type of assistance provided. Lastly, testing criteria to exit LEP status and other issues concerning exiting LEP status are reviewed 展开更多
关键词 ESL (English as a Second Language) bilingual education LEP (Limited English Proficient) LanguageProficiency Assessment linguistics accommodations direct and indirect accommodations standardized testing
下载PDF
Quality and Testing Standards on Rice Production in China and Development Strategies
8
作者 XIE LiHong CHEN Neng DUAN BinWu 《China Standardization》 2006年第3期16-20,共5页
China is the biggest country of rice production and consumption in the world;more than 50% of the population feeds chiefly on rice. The quality of rice and its role as a staplefood carry much weight. The rice qualitie... China is the biggest country of rice production and consumption in the world;more than 50% of the population feeds chiefly on rice. The quality of rice and its role as a staplefood carry much weight. The rice qualities are those aspects concerning processing, appearance,cooking, nutrition and safety of the product. The study, formulation and implementation of standardson rice qualities and testing bear heavily on the improving of rice qualities, human health,substitution of rice varieties, promoting quality rice production and regulating rice market. 展开更多
关键词 RATE Quality and testing standards on Rice Production in China and Development Strategies
下载PDF
文献A Successful Strategy for Satellite Development and Testing点评 被引量:1
9
作者 冯振兴 《航天器环境工程》 2009年第3期278-286,200,共9页
文章对美国在1998-2002年执行"快,好,省"采购改革方案期间航天器故障率上升146%的3个原因进行了分析与点评。这3个原因包括:对标准、规范严格遵循的意识下降;航天元器件复合度激增;系统工程管理失控。文章对抑制故障率上升的... 文章对美国在1998-2002年执行"快,好,省"采购改革方案期间航天器故障率上升146%的3个原因进行了分析与点评。这3个原因包括:对标准、规范严格遵循的意识下降;航天元器件复合度激增;系统工程管理失控。文章对抑制故障率上升的对策进行归纳,其中最重要的一条是:卫星研制工作必须严谨,一丝不苟地按照相关标准进行(环境)试验。 展开更多
关键词 卫星 环境试验 规范 标准 可靠性
下载PDF
Interpretation of Key Concepts in Language Testing: Validity, Validation and Reliability
10
作者 黄丽娜 《海外英语》 2013年第21期262-263,共2页
Language testing is an important link in language teaching,in this paper,the two important criteria of language test the reliability and validity has carried on the detailed elaboration,in order to a language teacher ... Language testing is an important link in language teaching,in this paper,the two important criteria of language test the reliability and validity has carried on the detailed elaboration,in order to a language teacher proposition and evaluation test more scientific. 展开更多
关键词 LANGUAGE testing standard RELIABILITY validity
下载PDF
文献“Software Testing in Space Programs”点评
11
作者 冯振兴 《航天器环境工程》 2008年第5期492-499,400,共9页
作者以他个人的观点,对该文献中重要部分进行了点评,指出:空间软件地面可靠性测试尽管困难重重且有诸多限制,但不能放松甚至放弃执行现有的软件地面测试标准;应从"精神号"火星探测器飞行失败中吸取教训,加强软件地面测试,包... 作者以他个人的观点,对该文献中重要部分进行了点评,指出:空间软件地面可靠性测试尽管困难重重且有诸多限制,但不能放松甚至放弃执行现有的软件地面测试标准;应从"精神号"火星探测器飞行失败中吸取教训,加强软件地面测试,包括传统软件黑盒和白盒测试方法中的典型测试项目(如:健壮测试、应力测试、极值测试、随机测试等);已经公布的新软件研发标准——Aerospace Report No.TOR-2004(3909)-3537,Software Development Standard for Space Systems值得我们参考。 展开更多
关键词 可靠性 航天器 军标 软件 地面试验
下载PDF
Challenges and improvements in testosterone and estradiol testing 被引量:3
12
作者 Hubert W Vesper Julianne C Botelho Yuesong Wang 《Asian Journal of Andrology》 SCIE CAS CSCD 2014年第2期178-184,I0006,I0007,共9页
Assays that measure steroid hormones in patient care, public health, and research need to be both accurate and precise, as these criteria help to ensure comparability across all clinical and research applications. Thi... Assays that measure steroid hormones in patient care, public health, and research need to be both accurate and precise, as these criteria help to ensure comparability across all clinical and research applications. This review addresses major issues relevant to assay variability and describes recent activities by the US Centers for Disease Control and Prevention (CDC) to improve assay performance. Currently, high degrees of accuracy and precision are not always met for testosterone and estradiol measurements; although technologies for steroid hormone measurement have advanced significantly, measurement variability within and across laboratories has not improved accordingly. Differences in calibration and specificity are discussed as sources of variability in measurement accuracy. Ultimately, a combination of factors appears to cause inaccuracy of steroid hormone measurements, with nonuniform assay calibration and lack of specificity being two major contributors to assay variability. Within-assay variability for current assays is generally high, especially at low analyte concentrations. The CDC Hormone Standardization (HoSt) Program is improving clinical assays, as evidenced by a 50% decline in mean absolute bias between mass spectrometry assays and the CDC reference method from 2007 to 2011. This program provides the measurement traceability to CDC reference methods and helps to minimize factors affecting measurement variability. 展开更多
关键词 CDC hormone standardization CDC HoSt ESTRADIOL steroid hormone testing testOSTERONE
下载PDF
A Mini Review on Testing Methods for Mechanical Properties of Natural Fibre Honeycomb Sandwich Structure and Fractography Analysis 被引量:1
13
作者 Nahiyan Al-Azad Nur Hafidah Binti Dedifitrianto Mohd. Kamal Mohd. Shah 《Journal of Materials Science and Chemical Engineering》 2021年第5期29-38,共10页
This paper is a review of the past research of mechanical testing methods for natural fibre honeycomb sandwich structure as well as failure modes analysis at a microscopic level by using Scanning Electron Microscope (... This paper is a review of the past research of mechanical testing methods for natural fibre honeycomb sandwich structure as well as failure modes analysis at a microscopic level by using Scanning Electron Microscope (SEM). As the world is garnering attention towards renewable resources for environmental purposes, studies of natural fibre have been increasing as well as the application of natural fibre throughout various industries such as aerospace, automobiles, and construction sectors. This paper is started with brief information regarding the honeycomb sandwich structure, introduction to natural fibre, its applications as well as the factors affecting the performances of the structure. Next, the mechanical testing methods are listed out as well as the expected outcomes obtained from the respective testing. The mechanical properties are also identified by conducting lab tests according to the ASTM standard for sandwich and core structures. The microstructure of the deformed samples is then examined under Scanning Electron Microscope (SEM) by using different magnifications to study the failure mechanisms of the samples. The images obtained from the SEM test are analyzed by using fractography which will show the failure modes of the samples. This article is based on past research conducted by professional on the related topic. 展开更多
关键词 Natural Fibre Honeycomb Sandwich Structure testing Methods ASTM standard SEM test
下载PDF
Introduction of creep-rupture testing capability and proficiency at Baosteel
14
作者 FANG Jian GU Jun ZHOU Yedong 《Baosteel Technical Research》 CAS 2017年第4期9-15,共7页
To characterize the long-term service performance and predict the lifetime of heat-resistant steel applications,more than 300 test pieces can be loaded simultaneously at Baosteel to determine the relationship between ... To characterize the long-term service performance and predict the lifetime of heat-resistant steel applications,more than 300 test pieces can be loaded simultaneously at Baosteel to determine the relationship between stress and rupture duration at specific temperatures. In addition, versatile testing methods have been established that evaluate creep-rupture, stress-relaxation, and creep-fatigue, as well as state-of-the-art tensile testing at hyper-high temperatures exceeding 2 100 ~2. Based on the Larson-Miller method, according to API 530, the accumulation of large volumes of data with respect to stress, temperature, and rupture time of actually tested steels ensures the reliability of predicting the allowable working stress over 100 000 h at any given temperature. For examples ,the stress tendencies against rupture time of T/P91 and T/P92 steel tubes, as obtained by Baosteel, are consistent with those from NIMS and ECCC. As an accredited provider of the Proficiency Testing schemes in ISO/ IEC 17025 and ISO/IEC 17043, Baosteel has periodically organized national proficiency testing with respect to creep and rupture, thereby providing an efficient way for all parties to assess their technical competence when performing uniaxial creep testing by the methods in ISO 204 and ASTM E139. 展开更多
关键词 CREEP RUPTURE heat-resistant steels API 530 standard ACCREDITATION proficiency testing
下载PDF
Test Standards for Direct Steam Generating Solar Concentrators
15
作者 Mahesh M. Rathore Ravi M. Warkhedkar 《Journal of Power and Energy Engineering》 2015年第12期1-10,共10页
There are a few standards reported in the literature for testing and evaluation of thermal performance of solar concentrators based on sensible heating of working fluid. The preceding standard measures only the cookin... There are a few standards reported in the literature for testing and evaluation of thermal performance of solar concentrators based on sensible heating of working fluid. The preceding standard measures only the cooking efficiency and cooking capacity. Apart from thermal efficiency, there is an imperative need for other important parameters of the solar concentrators such as its stagnation temperature, cooking capacity, cost per watts delivered, weight of the cooker, ease of handling and aesthetics. The characterization of a concentrator at its operating temperature settles appropriate size and type of concentrator for any thermal application. The performance test is conducted at Chandwad (20.3292°N, 74.2444°E), Maharashtra and the proposed protocol aims for evaluation of thermal performance of solar cooking system and standardization of reporting the test results so that anyone can easily recognize and use it. 展开更多
关键词 Solar CONCENTRATOR testS Efficiency COOKING Power standardIZATION in testS and REPORTING
下载PDF
Standardization of apple cancellation test for neglect patients in Korea:An observational study
16
作者 Woo-Hyuk Jang Jong-Sik Jang 《World Journal of Clinical Cases》 SCIE 2023年第22期5236-5243,共8页
BACKGROUND Neglect can be divided into two types using apple cancellation test(apple test):Egocentric neglect(EN)and allocentric neglect(AN).However,in South Korea,apple test results and decision criteria are still la... BACKGROUND Neglect can be divided into two types using apple cancellation test(apple test):Egocentric neglect(EN)and allocentric neglect(AN).However,in South Korea,apple test results and decision criteria are still largely dependent on tests by foreign countries.AIM To establish a new South Korea standard and improve the accuracy of neglect assessment,the apple experiment was standardized in this study.METHODS This study was conducted on 223 healthy subjects for a total of 7 mo from August 2021 to February 2022.Standardization was carried out using the original apple test developed by Bickerton in 2011.In scoring for the apple test,total omission error refers to the number of missed targets(full apple)in the entire test sheet(left,middle,and right area).The score for EN is the difference between the correct number of right area and the correct number of left area(excluding the middle area).For AN,the score is difference between the number of left opening apples and number of right opening apples(including the middle area).Linear regression analysis was used for standardization using the general characteristics of subjects and the results of the apple test.RESULTS The cut-off score,which is the standard value indicating the pathological condition by combining the results of all subjects,is as follows:Total omission error(5),error for EN(2),and error for AN(2).Also,differences in cut-off score according to age were found.CONCLUSION This study will be helpful in facilitating a more accurate differential diagnosis of neglect. 展开更多
关键词 Apple cancellation test Egocentric neglect Allocentric neglect Brain injury standardIZATION
下载PDF
Smart Inverter Functionality Testing for Battery Energy Storage Systems
17
作者 Jun Hashimoto Taha Selim Ustun Kenji Otani 《Smart Grid and Renewable Energy》 2017年第11期337-350,共14页
Variable distributed energy resources (DERs) such as photovoltaic (PV) systems and wind power systems require additional power resources to control the balance between supply and demand. Battery energy storage systems... Variable distributed energy resources (DERs) such as photovoltaic (PV) systems and wind power systems require additional power resources to control the balance between supply and demand. Battery energy storage systems (BESSs) are one such possible resource for providing grid stability. It has been proposed that decentralized BESSs could help support microgrids (MGs) with intelligent control when advanced functionalities are implemented with variable DERs. One key challenge is developing and testing smart inverter controls for DERs. This paper presents a standardized method to test the interoperability and functionality of BESSs. First, a survey of grid-support standards prevalent in several countries was conducted. Then, the following four interoperability functions defined in IEC TR 61850-90-7 were tested: the specified active power from storage test (INV4), the var-priority Volt/VAR test (VV) and the specified power factor test (INV3) and frequency-watt control (FW). This study then out-lines the remaining technical issues related to basic BESS smart inverter test protocols. 展开更多
关键词 Battery ENERGY Storage Systems Distributed ENERGY Resources SMART INVERTER CONTROLS Grid-Support standards test Protocols Interoperability
下载PDF
Comparison of Vs and SPT Soil Liquefaction Assessments of NCEER: Including Hypothesis Testing
18
作者 Min-Hao Wu Jui-Pin Wang Chih-Kun Liao 《International Journal of Geosciences》 2023年第11期1085-1099,共15页
Soil liquefaction is one of the complex research topics in geotechnical engineering and engineering geology. Especially after the 1964 Niigata earthquake (Japan) induced many soil liquefaction incidents, a variety of ... Soil liquefaction is one of the complex research topics in geotechnical engineering and engineering geology. Especially after the 1964 Niigata earthquake (Japan) induced many soil liquefaction incidents, a variety of soil liquefaction studies were conducted and reported, including the liquefaction potential assessment methods utilizing the shear wave velocity (V<sub>s</sub>) or SPT-N profiles (SPT: standard penetration test). This study used the V<sub>s</sub> and SPT methods recommended by the National Center for Earthquake Engineering Research (NCEER) to examine which is more conservative according to the assessment results on 41 liquefiable soil layers at sites in two major cities in Taiwan. Statistical hypothesis testing was used to make the analysis more quantitative and objective. Based on three sets of hypothesis tests, it shows that the hypothesis—the SPT method is more conservative than the V<sub>s</sub> method—was not rejected on a 5% level of significance. 展开更多
关键词 Soil Liquefaction standard Penetration test Shear Wave Velocity Hypothesis testing
下载PDF
Obtaining 2D Soil Resistance Profiles from the Integration of Electrical Resistivity Data and Standard Penetration Test (SPT) and Light Dynamic Penetrometer (DPL) Resistance Tests—Applications in Mass Movements Studies
19
作者 Cassiano Antonio Bortolozo Tatiana Sussel Gonçalves Mendes +10 位作者 Mariana Ferreira Benessiuti Motta Silvio Jorge Coelho Simões Tristan Pryer Daniel Metodiev Marcio Roberto Magalhães de Andrade Maiconn Vinicius de Moraes Danielle Silva de Paula Nélio José Bastos Luana Albertani Pampuch Rodolfo Moreda Mendes Marcio Augusto Ernesto de Moraes 《International Journal of Geosciences》 2023年第9期840-854,共15页
In Brazil and various regions globally, the initiation of landslides is frequently associated with rainfall;yet the spatial arrangement of geological structures and stratification considerably influences landslide occ... In Brazil and various regions globally, the initiation of landslides is frequently associated with rainfall;yet the spatial arrangement of geological structures and stratification considerably influences landslide occurrences. The multifaceted nature of these influences makes the surveillance of mass movements a highly intricate task, requiring an understanding of numerous interdependent variables. Recent years have seen an emergence in scholarly research aimed at integrating geophysical and geotechnical methodologies. The conjoint examination of geophysical and geotechnical data offers an enhanced perspective into subsurface structures. Within this work, a methodology is proposed for the synchronous analysis of electrical resistivity geophysical data and geotechnical data, specifically those extracted from the Light Dynamic Penetrometer (DPL) and Standard Penetration Test (SPT). This study involved a linear fitting process to correlate resistivity with N10/SPT N-values from DPL/SPT soundings, culminating in a 2D profile of N10/SPT N-values predicated on electrical profiles. The findings of this research furnish invaluable insights into slope stability by allowing for a two-dimensional representation of penetration resistance properties. Through the synthesis of geophysical and geotechnical data, this project aims to augment the comprehension of subsurface conditions, with potential implications for refining landslide risk evaluations. This endeavor offers insight into the formulation of more effective and precise slope management protocols and disaster prevention strategies. 展开更多
关键词 GEOPHYSICS Geotechnical Data Electrical Resistivity Method standard Penetration test (SPT) Light Dynamic Penetrometer (DPL) Mass Movements
下载PDF
Application ofStandard Penetration Test(SPT) in Hydro- power Projects in Sudan
20
作者 Zhang xiaoqiang Wanglei 《商情》 2010年第3期73-75,共3页
关键词 苏丹 数据定址存贮器 信息传达 差别
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部