High reliability is the key to performance of electrical control equipment. PLC combines computer technology, automatic control technology and communication technology and becomes widely used for automation of industr...High reliability is the key to performance of electrical control equipment. PLC combines computer technology, automatic control technology and communication technology and becomes widely used for automation of industrial processes. Some requirements of complex PLC systems cannot be satisfied by the traditional verification methods. In this paper, an efficient method for the PLC systems modeling and verification is proposed. To ensure the high-speed property of PLC, we proposed a technique of “Time interval model” and “notice-waiting”. It could reduce the state space and make it possible to verify some complex PLC systems. Also, the conversion from the built PLC model to the Promela language is obtained and a tool PLC-Checker for modeling and checking PLC systems are designed. Using PLC-Checker to check a classical PLC example, a counter-example is found. Although the probability of this logic error occurs very small, it could result in system crash fatally.展开更多
This paper describes a data transmission method using a cyclic redundancy check and inaudible frequencies.The proposed method uses inaudible high frequencies from 18 k Hz to 22 k Hz generated via the inner speaker of ...This paper describes a data transmission method using a cyclic redundancy check and inaudible frequencies.The proposed method uses inaudible high frequencies from 18 k Hz to 22 k Hz generated via the inner speaker of smart devices.Using the proposed method,the performance is evaluated by conducting data transmission tests between a smart book and smart phone.The test results confirm that the proposed method can send 32 bits of data in an average of 235 ms,the transmission success rate reaches 99.47%,and the error detection rate of the cyclic redundancy check is0.53%.展开更多
目的 Linear Programming的simplexmethod建模求最优解。方法应用simplexmethod.结果建立了LinearProgramming的数学模型并用simplexmethod求得了最优解.结论因为单纯形表反映了Linear Programming的所有信息,故用simplexmethod可简便...目的 Linear Programming的simplexmethod建模求最优解。方法应用simplexmethod.结果建立了LinearProgramming的数学模型并用simplexmethod求得了最优解.结论因为单纯形表反映了Linear Programming的所有信息,故用simplexmethod可简便地求得最优解.simplexmethod的基本思路是:先将Linear Programming用sim-plexmethod划为标准型,根据问题的标准型,进行初等行变换,将主元素列除主元素化为1外其余的元素均化为0,当基变量值全为非负时,问题就得到了最优解.展开更多
The method of characteristic(MOC) was adopted to analyze the check valve-induced water hammer behaviors for a Parallel Pumps Feedwater System(PPFS) during the alternate startup process.The motion of check valve disc w...The method of characteristic(MOC) was adopted to analyze the check valve-induced water hammer behaviors for a Parallel Pumps Feedwater System(PPFS) during the alternate startup process.The motion of check valve disc was simulated using inertial valve model.Transient parameters including the pressure oscillation,local flow velocity and slamming of the check valve disc etc.have been obtained.The results showed that severe slamming between the valve disc and valve seat occurred during the alternate startup of parallel pumps.The induced maximum pressure vibration amplitude is up to 5.0 MPa.The scheme of appending a damping torque to slow down the check valve closing speed was also performed to mitigate of water hammer.It has been numerically approved to be an effective approach.展开更多
The parallelism of saw guide motion locus against the blade is one of the main iterns in the testing of the geometric precision of the whole woodworking band saxving-machine. It reflects the making and mounting precis...The parallelism of saw guide motion locus against the blade is one of the main iterns in the testing of the geometric precision of the whole woodworking band saxving-machine. It reflects the making and mounting precisions of the sawguide device,having a direct effect on the working performance. the saw timber quality. and the safety (nature) of the woodworking band sawing-machine, so it is of great importance in the testing process of the band sawing-machine assembly and their going out of the plant.展开更多
Formal methods are the mathematically techniques and tools which are used at early stages of software development lifecycle processes. The utter need of using formal methods in safety critical system leads to accuracy...Formal methods are the mathematically techniques and tools which are used at early stages of software development lifecycle processes. The utter need of using formal methods in safety critical system leads to accuracy, consistency and correctness in proposed system. In safety critical real time application, requirements should be unambiguous and very accurate which can be achieved by using mathematical theorems. There is utter need to focus on the requirement phase which is the most critical phase of SDLC. This paper focuses on the use of Z notation for incorporating the accuracy, consistency, and eliminates ambiguity in safety critical system: Road Traffic Management System as a case study. The syntax, semantics, type checking and domain checking are further verified by using Z/EVES: a Z notation type checker tool.展开更多
Exceptions are those abnormal data flow which needs additional calculation to deal with. Exception analysis concerned abnormal flow contains a lot of research content, such as exception analysis method, program verifi...Exceptions are those abnormal data flow which needs additional calculation to deal with. Exception analysis concerned abnormal flow contains a lot of research content, such as exception analysis method, program verification. This article introduces another research direction of exception analysis which based on formal method. The article analyses and summarizes those research literatures referring exception analysis and exception handling logic verification based on formal reasoning and model checking. In the article, we provide an overview of the relationship and difference between traditional ideas and formal method concerning program exception analysis. In the end of the article, we make some ideas about exception analysis based on formal semantic study of procedure calls. Exception handling is seen as a special semantic effect of procedures calls.展开更多
With the rapid growth of the offshore wind industry, the innovative floating offshore wind turbine is chosen as the most feasible device to harvest the vast wind energy in deep water area. However there is no practica...With the rapid growth of the offshore wind industry, the innovative floating offshore wind turbine is chosen as the most feasible device to harvest the vast wind energy in deep water area. However there is no practical design guide for the floating wind turbine especially the floating foundation. In this paper, based on the investigation on the worldwide floating wind turbine and current available expertise on floating platforms accumulated in offshore O/G (oil and gas) industry, an integrated design methodology is presented according to the specialized characteristics of wind turbine, including the type selection of foundation and mooring system, design standard, design procedure, design conditions, key technologies involved. Finally a semi-submersible floating foundation is designed to support certain megawatt-rating wind turbine of Goldwind and also performance analysis and code checks are performed to validate the design. The design method of the floating foundation provided in this paper is proved feasible and can be adopted in practical engineering design.展开更多
文摘High reliability is the key to performance of electrical control equipment. PLC combines computer technology, automatic control technology and communication technology and becomes widely used for automation of industrial processes. Some requirements of complex PLC systems cannot be satisfied by the traditional verification methods. In this paper, an efficient method for the PLC systems modeling and verification is proposed. To ensure the high-speed property of PLC, we proposed a technique of “Time interval model” and “notice-waiting”. It could reduce the state space and make it possible to verify some complex PLC systems. Also, the conversion from the built PLC model to the Promela language is obtained and a tool PLC-Checker for modeling and checking PLC systems are designed. Using PLC-Checker to check a classical PLC example, a counter-example is found. Although the probability of this logic error occurs very small, it could result in system crash fatally.
基金supported by Ministry of Educationunder Basic Science Research Program under Grant No.NRF-2013R1A1A2061478
文摘This paper describes a data transmission method using a cyclic redundancy check and inaudible frequencies.The proposed method uses inaudible high frequencies from 18 k Hz to 22 k Hz generated via the inner speaker of smart devices.Using the proposed method,the performance is evaluated by conducting data transmission tests between a smart book and smart phone.The test results confirm that the proposed method can send 32 bits of data in an average of 235 ms,the transmission success rate reaches 99.47%,and the error detection rate of the cyclic redundancy check is0.53%.
文摘目的 Linear Programming的simplexmethod建模求最优解。方法应用simplexmethod.结果建立了LinearProgramming的数学模型并用simplexmethod求得了最优解.结论因为单纯形表反映了Linear Programming的所有信息,故用simplexmethod可简便地求得最优解.simplexmethod的基本思路是:先将Linear Programming用sim-plexmethod划为标准型,根据问题的标准型,进行初等行变换,将主元素列除主元素化为1外其余的元素均化为0,当基变量值全为非负时,问题就得到了最优解.
基金Supported by the national key laboratory on Bubble Physics and Natural Circulation (BNPC)the Program for New Century Excellent Talents in University (NCET-06-0837)
文摘The method of characteristic(MOC) was adopted to analyze the check valve-induced water hammer behaviors for a Parallel Pumps Feedwater System(PPFS) during the alternate startup process.The motion of check valve disc was simulated using inertial valve model.Transient parameters including the pressure oscillation,local flow velocity and slamming of the check valve disc etc.have been obtained.The results showed that severe slamming between the valve disc and valve seat occurred during the alternate startup of parallel pumps.The induced maximum pressure vibration amplitude is up to 5.0 MPa.The scheme of appending a damping torque to slow down the check valve closing speed was also performed to mitigate of water hammer.It has been numerically approved to be an effective approach.
文摘The parallelism of saw guide motion locus against the blade is one of the main iterns in the testing of the geometric precision of the whole woodworking band saxving-machine. It reflects the making and mounting precisions of the sawguide device,having a direct effect on the working performance. the saw timber quality. and the safety (nature) of the woodworking band sawing-machine, so it is of great importance in the testing process of the band sawing-machine assembly and their going out of the plant.
文摘Formal methods are the mathematically techniques and tools which are used at early stages of software development lifecycle processes. The utter need of using formal methods in safety critical system leads to accuracy, consistency and correctness in proposed system. In safety critical real time application, requirements should be unambiguous and very accurate which can be achieved by using mathematical theorems. There is utter need to focus on the requirement phase which is the most critical phase of SDLC. This paper focuses on the use of Z notation for incorporating the accuracy, consistency, and eliminates ambiguity in safety critical system: Road Traffic Management System as a case study. The syntax, semantics, type checking and domain checking are further verified by using Z/EVES: a Z notation type checker tool.
文摘Exceptions are those abnormal data flow which needs additional calculation to deal with. Exception analysis concerned abnormal flow contains a lot of research content, such as exception analysis method, program verification. This article introduces another research direction of exception analysis which based on formal method. The article analyses and summarizes those research literatures referring exception analysis and exception handling logic verification based on formal reasoning and model checking. In the article, we provide an overview of the relationship and difference between traditional ideas and formal method concerning program exception analysis. In the end of the article, we make some ideas about exception analysis based on formal semantic study of procedure calls. Exception handling is seen as a special semantic effect of procedures calls.
文摘With the rapid growth of the offshore wind industry, the innovative floating offshore wind turbine is chosen as the most feasible device to harvest the vast wind energy in deep water area. However there is no practical design guide for the floating wind turbine especially the floating foundation. In this paper, based on the investigation on the worldwide floating wind turbine and current available expertise on floating platforms accumulated in offshore O/G (oil and gas) industry, an integrated design methodology is presented according to the specialized characteristics of wind turbine, including the type selection of foundation and mooring system, design standard, design procedure, design conditions, key technologies involved. Finally a semi-submersible floating foundation is designed to support certain megawatt-rating wind turbine of Goldwind and also performance analysis and code checks are performed to validate the design. The design method of the floating foundation provided in this paper is proved feasible and can be adopted in practical engineering design.