Noise pollution is one of the common physical harmful factors in many work environments.The current study aimed to assess personal and environmental sound pressure level and project the sound-Isosonic map in one of th...Noise pollution is one of the common physical harmful factors in many work environments.The current study aimed to assess personal and environmental sound pressure level and project the sound-Isosonic map in one of the Razavi Khorasan Paste manufacture using Surfer V.14 and Noise at work V.5.0.This cross-sectional,descrip-tive study is analytical that was conducted in 2018 in the Paste factory that contains Canister,production and Brewing unit.Following ISO 9612:2009,Casella Cel-320 was used to measure personal sound pressure level,while CEL-450 sound level meter(manufactured by Casella-Cel,the UK)was employed to assess environmental sound pressure level.Statistical analyzes was done using SPSS V.18 and Linear Regression test.The sound-isosonic maps were projected using Surfer V.14 and Noise at work V.5.0.The results of assessing personal sound pressure level indicated that the highest received dose(172.21%)and personal equivalent sound level(87.36 dBA)were recorded for workers in the Canister unit.According to results of measuring of the environmental sound pressure level,out of 16 measurement stations in this unit,overall 87.5%were regarded as danger and caution areas.The lowest and highest sound pressure levels in this units were 61 dBA and 92 dBA that belong to Brewing and Canister units respectively.Results indicate Over 75%of the Canister and production units had a sound pressure level greater than 85 dBA and these two units were regarded as the most dangerous area in terms of noise pollution.It is there-fore necessary to implement noise control measures,apply hearing protection program and auditory tests among workers in these units.展开更多
In real life, when a noise problem occurs, it is important to identify the cause and measure the noise of the source, since it may affect human beings or other constructions due to vibration generated from noise, so i...In real life, when a noise problem occurs, it is important to identify the cause and measure the noise of the source, since it may affect human beings or other constructions due to vibration generated from noise, so it is necessary to determine the noise related to a specific source like a machine in the presence of other sources which is a very important approach in noise control engineering. In this article a full experiment was executed to measure the sound pressure levels of various sources (stationary and non-stationary), in both an anechoic chamber and a non-ideal noisy environment. The sound pressure level was extracted for different sources and compared for both ideal and non-ideal environment. The results showed that acoustical free field of the space is the best field to do measurements to avoid reflection, on the other hand the difference between the source and the background should be more than 3 dB to get better results.展开更多
Exposure to noise can lead to anatomical,nonauditory,and auditory impacts.The auditory influence of noise exposure is manifested in the form of Noise-induced hearing loss(NIHL).The current study aimed at present a sig...Exposure to noise can lead to anatomical,nonauditory,and auditory impacts.The auditory influence of noise exposure is manifested in the form of Noise-induced hearing loss(NIHL).The current study aimed at present a signal to noise ratio model of otoacoustic emission of rats’ears in the light of the combined effect of sound pressure level,sound frequency,exposure time,and potassium concentration of the used water.In total,36 adult male rates,whose age varied from 3 to 4 months and had a weight of 200±50 g,were randomly divided into 12 groups,with each group consisting of 3 rats.The rats in both groups(case and control groups)were exposed to SPLs of 85,95,and 105 dB,emitted from sources that generated white noise.A distortion product otoacoustic emission(DPOAE)machine(4000 I/O manufactured by Homoth of Germany)was utilized to gauge the signal to noise ratio(SNR)of otoacoustic emissions of rats’ears at various frequencies in an acoustic room.The inclusion criterion was SNR≥6 dB.The collected data were fed into the Statistical Package for Social Sciences(SPSS)version 18,followed by conducting descriptive and inferential data analysis procedures.The results of SNR analysis indicated that over 82%of all data had SNRs that were equal to or greater than 6 dB.These data were considered as acceptable response.Furthermore,SPL and sound frequency had significant associations with SNR(P<0.0001).Exposure time also significantly correlated with SNR(P=0.008).However,the potassium concentration of the used water had no significant correlation with SNR(P=0.97).High sound pressure levels result in lower DPOAE.Furthermore,higher frequency leads to higher SNR.On the contrary,longer exposure time reduces SNR.Finally,the potassium concentration of the used water has no effect on SNR.展开更多
Noise pollution is one of the most significant harmful physical factors in the industrial and occupational environments.Due to the high costs of exposure to excessive noise;continuous sound evaluation,propose and impl...Noise pollution is one of the most significant harmful physical factors in the industrial and occupational environments.Due to the high costs of exposure to excessive noise;continuous sound evaluation,propose and implement noise control plans in occupational environments is necessary.Thus,the present study aimed to review environmental sound measurements,drawing of noise maps,and prioritizing the engineering noise control methods using the Analytic Hierarchy Process(AHP).This study was a descriptive-analytical study that aimed to assess occupational noises and present a control plan in the City Gas Stations(CGSs)of Kerman,Iran in 2021.The present study was done in two phases.In the first phase,six CGSs were investigated to measure and evaluate the noise.In addition,the noise map of a CGS was drawn using the Surfer software.Finally,the AHP was used in the second phase of the research to prioritize the control measures.In this phase,four criteria and ten alternatives were identified.According to first phase results,the sound pressure level(SPL)of the stations varied from 76 to 98 dBA.Besides,the majority of the studied stations had a sound level higher than 85 dBA(danger zone).The second phase of the study showed that out of the four evaluated criteria,the executability criterion had the highest impact and the cost criterion had the lowest impact on the selection of control measures with a weight of 0.587 and 0.052,respectively.Based on the results of prioritization of the alternatives,using a silenced regulator(weight of 0.223)and increasing the thickness of the tube(weight of 0.023)had the highest and lowest priorities among the alternatives,respectively.The use of engineering noise control methods such as using silenced regulators was the best way to control the noises of CGSs.Additionally;it is noteworthy that AHP is a practical method for prioritizing alternatives to achieve the most accurate decision-making.The results of AHP can be of great help to health and safety experts and managers in choosing the sound engineering control measures more precisely.展开更多
The performance of classic Mel-frequency cepstral coefficients (MFCC) is unsatisfactory in noisy environment with different sound sources from nature. In this paper, a classification approach of the ecological environ...The performance of classic Mel-frequency cepstral coefficients (MFCC) is unsatisfactory in noisy environment with different sound sources from nature. In this paper, a classification approach of the ecological environmental sounds using the double-level energy detection (DED) was presented. The DED was used to detect the existence of the sound signals under noise conditions. In addition, MFCC features from the frames which were detected the presence of the sound signals by DED were extracted. Experimental results show that the proposed technology has better noise immunity than classic MFCC, and also outperforms time-domain energy detection (TED) and frequency-domain energy detection (FED) respectively.展开更多
The construction of major marine infrastructure projects and the exploration and development of deep-sea mineral resources require fine imaging of seabed strata and structures.The highresolution marine seismic explora...The construction of major marine infrastructure projects and the exploration and development of deep-sea mineral resources require fine imaging of seabed strata and structures.The highresolution marine seismic exploration based on a high broadband sparker source is an important approach to reveal seabed stratum and reservoir structure,and identify geohazard.To optimize the performance of sparker seismic source,we investigated the electro-acoustic characteristics of spark discharge under conditions of different charging voltages and electrode numbers.Results show that the sound source level increased with the increase of the charging voltage,whereas the main frequency decreased when the charging voltage increases.In addition,it was found that the charging capacitance had more obvious influence on the main frequency than the sound source level did.Although the load energy decreased with increasing electrode number,the sound source level still increased but the main frequency decreased.Meanwhile,the primary to bubble(P/B)ratio increased with the increase of the electrode number.To gain a deeper insight into the electro-acoustic characteristics,we investigate the relationship between sound source level and power peak,from which a good correlation was observed.A more practical statistical analysis on the rise rate of current was processed,and a perfect logarithmic function was derived.Furthermore,we found that the main frequency was most possibly subjected to the electrical energy,especially the charging energy per electrode.The results indicate that the charging energy per electrode less than 10 J could increase the main frequency to above 300 Hz.At last,the main frequency could be reduced to 20 Hz when the charging energy of a single-electrode discharge was enhanced to over 4 kJ.This study shall be helpful in developing a sparker seismic source and improving the performance for marine engineering exploration and geohazard assessment.展开更多
文摘Noise pollution is one of the common physical harmful factors in many work environments.The current study aimed to assess personal and environmental sound pressure level and project the sound-Isosonic map in one of the Razavi Khorasan Paste manufacture using Surfer V.14 and Noise at work V.5.0.This cross-sectional,descrip-tive study is analytical that was conducted in 2018 in the Paste factory that contains Canister,production and Brewing unit.Following ISO 9612:2009,Casella Cel-320 was used to measure personal sound pressure level,while CEL-450 sound level meter(manufactured by Casella-Cel,the UK)was employed to assess environmental sound pressure level.Statistical analyzes was done using SPSS V.18 and Linear Regression test.The sound-isosonic maps were projected using Surfer V.14 and Noise at work V.5.0.The results of assessing personal sound pressure level indicated that the highest received dose(172.21%)and personal equivalent sound level(87.36 dBA)were recorded for workers in the Canister unit.According to results of measuring of the environmental sound pressure level,out of 16 measurement stations in this unit,overall 87.5%were regarded as danger and caution areas.The lowest and highest sound pressure levels in this units were 61 dBA and 92 dBA that belong to Brewing and Canister units respectively.Results indicate Over 75%of the Canister and production units had a sound pressure level greater than 85 dBA and these two units were regarded as the most dangerous area in terms of noise pollution.It is there-fore necessary to implement noise control measures,apply hearing protection program and auditory tests among workers in these units.
文摘In real life, when a noise problem occurs, it is important to identify the cause and measure the noise of the source, since it may affect human beings or other constructions due to vibration generated from noise, so it is necessary to determine the noise related to a specific source like a machine in the presence of other sources which is a very important approach in noise control engineering. In this article a full experiment was executed to measure the sound pressure levels of various sources (stationary and non-stationary), in both an anechoic chamber and a non-ideal noisy environment. The sound pressure level was extracted for different sources and compared for both ideal and non-ideal environment. The results showed that acoustical free field of the space is the best field to do measurements to avoid reflection, on the other hand the difference between the source and the background should be more than 3 dB to get better results.
基金the output of a research project(registration number:24455)which was financially supported by Tehran University of Medical Sciences.
文摘Exposure to noise can lead to anatomical,nonauditory,and auditory impacts.The auditory influence of noise exposure is manifested in the form of Noise-induced hearing loss(NIHL).The current study aimed at present a signal to noise ratio model of otoacoustic emission of rats’ears in the light of the combined effect of sound pressure level,sound frequency,exposure time,and potassium concentration of the used water.In total,36 adult male rates,whose age varied from 3 to 4 months and had a weight of 200±50 g,were randomly divided into 12 groups,with each group consisting of 3 rats.The rats in both groups(case and control groups)were exposed to SPLs of 85,95,and 105 dB,emitted from sources that generated white noise.A distortion product otoacoustic emission(DPOAE)machine(4000 I/O manufactured by Homoth of Germany)was utilized to gauge the signal to noise ratio(SNR)of otoacoustic emissions of rats’ears at various frequencies in an acoustic room.The inclusion criterion was SNR≥6 dB.The collected data were fed into the Statistical Package for Social Sciences(SPSS)version 18,followed by conducting descriptive and inferential data analysis procedures.The results of SNR analysis indicated that over 82%of all data had SNRs that were equal to or greater than 6 dB.These data were considered as acceptable response.Furthermore,SPL and sound frequency had significant associations with SNR(P<0.0001).Exposure time also significantly correlated with SNR(P=0.008).However,the potassium concentration of the used water had no significant correlation with SNR(P=0.97).High sound pressure levels result in lower DPOAE.Furthermore,higher frequency leads to higher SNR.On the contrary,longer exposure time reduces SNR.Finally,the potassium concentration of the used water has no effect on SNR.
文摘Noise pollution is one of the most significant harmful physical factors in the industrial and occupational environments.Due to the high costs of exposure to excessive noise;continuous sound evaluation,propose and implement noise control plans in occupational environments is necessary.Thus,the present study aimed to review environmental sound measurements,drawing of noise maps,and prioritizing the engineering noise control methods using the Analytic Hierarchy Process(AHP).This study was a descriptive-analytical study that aimed to assess occupational noises and present a control plan in the City Gas Stations(CGSs)of Kerman,Iran in 2021.The present study was done in two phases.In the first phase,six CGSs were investigated to measure and evaluate the noise.In addition,the noise map of a CGS was drawn using the Surfer software.Finally,the AHP was used in the second phase of the research to prioritize the control measures.In this phase,four criteria and ten alternatives were identified.According to first phase results,the sound pressure level(SPL)of the stations varied from 76 to 98 dBA.Besides,the majority of the studied stations had a sound level higher than 85 dBA(danger zone).The second phase of the study showed that out of the four evaluated criteria,the executability criterion had the highest impact and the cost criterion had the lowest impact on the selection of control measures with a weight of 0.587 and 0.052,respectively.Based on the results of prioritization of the alternatives,using a silenced regulator(weight of 0.223)and increasing the thickness of the tube(weight of 0.023)had the highest and lowest priorities among the alternatives,respectively.The use of engineering noise control methods such as using silenced regulators was the best way to control the noises of CGSs.Additionally;it is noteworthy that AHP is a practical method for prioritizing alternatives to achieve the most accurate decision-making.The results of AHP can be of great help to health and safety experts and managers in choosing the sound engineering control measures more precisely.
文摘The performance of classic Mel-frequency cepstral coefficients (MFCC) is unsatisfactory in noisy environment with different sound sources from nature. In this paper, a classification approach of the ecological environmental sounds using the double-level energy detection (DED) was presented. The DED was used to detect the existence of the sound signals under noise conditions. In addition, MFCC features from the frames which were detected the presence of the sound signals by DED were extracted. Experimental results show that the proposed technology has better noise immunity than classic MFCC, and also outperforms time-domain energy detection (TED) and frequency-domain energy detection (FED) respectively.
基金Supported by the National Natural Science Foundation of China(No.42276195)the Natural Science Foundation of Zhejiang Province(No.LQ22D060006)the Science Foundation of Zhejiang Sci-Tech University(No.21022092-Y)。
文摘The construction of major marine infrastructure projects and the exploration and development of deep-sea mineral resources require fine imaging of seabed strata and structures.The highresolution marine seismic exploration based on a high broadband sparker source is an important approach to reveal seabed stratum and reservoir structure,and identify geohazard.To optimize the performance of sparker seismic source,we investigated the electro-acoustic characteristics of spark discharge under conditions of different charging voltages and electrode numbers.Results show that the sound source level increased with the increase of the charging voltage,whereas the main frequency decreased when the charging voltage increases.In addition,it was found that the charging capacitance had more obvious influence on the main frequency than the sound source level did.Although the load energy decreased with increasing electrode number,the sound source level still increased but the main frequency decreased.Meanwhile,the primary to bubble(P/B)ratio increased with the increase of the electrode number.To gain a deeper insight into the electro-acoustic characteristics,we investigate the relationship between sound source level and power peak,from which a good correlation was observed.A more practical statistical analysis on the rise rate of current was processed,and a perfect logarithmic function was derived.Furthermore,we found that the main frequency was most possibly subjected to the electrical energy,especially the charging energy per electrode.The results indicate that the charging energy per electrode less than 10 J could increase the main frequency to above 300 Hz.At last,the main frequency could be reduced to 20 Hz when the charging energy of a single-electrode discharge was enhanced to over 4 kJ.This study shall be helpful in developing a sparker seismic source and improving the performance for marine engineering exploration and geohazard assessment.