Various studies have suggested several environmental,pharmacological,medical,and optical interventions and some are in use but their efficacy in myopia control may be transient,and the cellular,molecular,and biochemic...Various studies have suggested several environmental,pharmacological,medical,and optical interventions and some are in use but their efficacy in myopia control may be transient,and the cellular,molecular,and biochemical mechanisms involved unclear.Daylight exposure is currently regarded as an effective and enduring strategy in the control of myopia development and progression.However,the mechanism behind the effect of outdoor exposure and its association with genetic predisposition and other relatively more significant environmental factors on myopia is still a conundrum.This review focuses on survey-based and intervention-based studies carried out to propose a mechanism that accounts for myopia development and important for its control.展开更多
The following article has been retracted due to the fact that it cannot be accepted as Duplicate Publication. The Editorial Board takes a very strong respect to the author’s situation on this matter. This paper publi...The following article has been retracted due to the fact that it cannot be accepted as Duplicate Publication. The Editorial Board takes a very strong respect to the author’s situation on this matter. This paper published in Journal of Power and Energy Engineering Vol.3 No.4, April 2015, has been removed from this site.展开更多
Daylight is a fundamental element to obtain built environments that promote environmental comfort and energy efficiency. However, strategies that enhance the building daylight performance can affect its thermal energe...Daylight is a fundamental element to obtain built environments that promote environmental comfort and energy efficiency. However, strategies that enhance the building daylight performance can affect its thermal energetic performance. In this sense, research that addresses these aspects at the same time is considered essential. The objective of this paper was to evaluate the daylighting and thermal-energetic performance of administrative environments in a public institution, and to propose strategies that will enhance the use of daylight and lower energy consumption. Therefore, for future projects, and considering new buildings, and retrofit, this research will be an important reference. The research was developed through a case study of an administrative building model, in which the characteristics of solar orientation, light shelf use, glass type, and light and dark colors in walls were modified and combined, deriving it into models proposed. The daylighting performance evaluations were performed through dynamic simulation with the Rhinoceros for Diva software, and the thermal-energetic performance evaluations with the EnergyPlus software. The results of the work showed that a suitable solar orientation has a great impact on the automation of daylight and the energy consumption of the evaluated models, followed by the type of glass and the use of the light colors in internal walls, and that the use of artificial lighting with dimerization is fundamental as a complement to the daylight autonomy. For the boundary conditions of the study, the use of light shelves modified neither the daylight performance nor the thermal-energetic performance of the evaluated models.展开更多
Currently, daylighting ducts system is widely used as a daylighting device. Generally, daylighting duct system efficiently takes light from outside during the day, and conveys daylight to required location through lig...Currently, daylighting ducts system is widely used as a daylighting device. Generally, daylighting duct system efficiently takes light from outside during the day, and conveys daylight to required location through light duct manufactured by high reflectance mirror. Daylighting duct system can convey daylight to underground space that has no windows opening to external space. Daylighting system is composed of light collection part, light guide part and light emission part. Efficiency of daylighting system is depending on type of each part used in the system. However, it is very difficult to estimate exact light flow in the system considering type of the parts. Authors performed measurement experiments to make clear the light flow with real-size model and miniature model of daylighting duct system. We discussed effect of type of the parts on efficiency of daylighting duct system.展开更多
Different approaches have been introduced for the daylighting system to reduce energy consumption, but they were not populated due to complex, high cost, and insufficient designs. There has been a recent problem in ac...Different approaches have been introduced for the daylighting system to reduce energy consumption, but they were not populated due to complex, high cost, and insufficient designs. There has been a recent problem in achieving uniform distribution of sunlight at a destination deep inside the building. Therefore, we propose a system to achieve high illumination by illuminating the surface of the absorber (optical fibers) uniformly. To capture sunlight, parabolic reflector and Fresnel lens are used. Different reflectors and lenses are considered, compared, and investigated to direct uniform light, which solves the heat problem, into the optical fibers. In addition, this study includes comparison between fiber-based daylighting systems. The proposed system has been verified through simulation and experimental results.展开更多
In the subtropical zone of China, a large number of old factory buildings rich in industrial historical and cultural value have been transformed into art studios. In the existing research on building renovation, there...In the subtropical zone of China, a large number of old factory buildings rich in industrial historical and cultural value have been transformed into art studios. In the existing research on building renovation, there are still problems such as insufficient lighting, low uniformity, and ignoring the effect of glare in the lighting environment of buildings after transformation. To fill this research gap, this paper provides a daylighting design strategy for these factory buildings in subtropical zones to ensure that the transformed art studios can offer an excellent indoor daylighting environment. Through the control variable method, the window-to-wall ratio, the form of external windows, and the visible light transmittance of glass are set with quantitative and variable values, and a design strategy that meets the requirements of international general daylighting standards is obtained step by step through the simulation. The daylight factor, uniformity, daylight autonomy, and dynamic glare probability are used in this research process to measure whether the daylighting strategy meets the daylighting requirements of the CIBSE Lighting Guide for art studios. The results show that the average indoor lighting coefficient can be increased from 1.29 to 6.18, and the minimum value of the lighting coefficient can be increased from 0.4 to 4.4 by enlarging the windowed wall ratio from 1:30 to 1:3, using the combination method of the horizontal window, skylight and skylight recommended by the analysis results, and selecting veneer glass with 88% transmittance. This allows for better uniform lighting inside the building and reduces glare. This conclusion can support the lighting performance design of industrial buildings in the future.展开更多
At the scheme design stage,the potential of daylighting is significant due to the saving for electric lighting use. There are few simple tools for architects to optimize the daylighting design. Therefore,it is useful ...At the scheme design stage,the potential of daylighting is significant due to the saving for electric lighting use. There are few simple tools for architects to optimize the daylighting design. Therefore,it is useful to develop a design guideline related to the evaluation of lighting energy saving potential and sunlight design strategies. This paper analyzes the impacts of different artificial lighting control methods and design parameters on daylighting. A direct correlation between lighting energy consumption and parameters such as orientations,window to wall ratio (WWR) and perimeter depth is established. A simplified prediction model is proposed to estimate lighting energy consumption with the given perimeter depth,WWR,and window transparency. Validation of the model is carried out compared with detailed lighting simulation software for an office building. After the variation analysis for these parameters,design advises for the daylighting design at scheme design phase are summarized.展开更多
This paper presents a comprehensive survey for the situation of light environment in large commercial building through architecture design information,subjective and objective fieldwork and online survey for three typ...This paper presents a comprehensive survey for the situation of light environment in large commercial building through architecture design information,subjective and objective fieldwork and online survey for three typical commercial building forms( centralized form, covered mall shopping center, lifestyle center).Descriptive method is used for statistical analysis which includes the evaluation of light environmental quality,subjective assessment among daylight and artificial illumination,effect of physical characteristics on subjective assessment of light environment. Based on the results of statistical analysis,the improving strategies for light environment are proposed in terms of making use of daylight,artificial lighting design and improvement of the overall light environmental quality. The design strategies which based on the consumer needs is very important can provide help for further impact prediction on the quality of light environment.展开更多
We investigated the link between ambulance transports and meteorological parameters of summer by using daily data in Osaka area, Japan. Daily observations for ambulance transports (from July 1 to September 30, 2009) w...We investigated the link between ambulance transports and meteorological parameters of summer by using daily data in Osaka area, Japan. Daily observations for ambulance transports (from July 1 to September 30, 2009) were obtained from Fire Department Service in Osaka. Data of meteorological parameters in Osaka area, Japan (from July 1 to September 30, 2009) were also obtained from Japan Meteorological Agency. Effect of meteorological parameters on ambulance transports was analyzed. A total of 49,526 ambulance transports were observed from July 1 to September 30, 2009 in Osaka, Japan. Ambulance transports were significantly correlated with mean air temperature (r = 0.298), the highest air temperature (r = 0.347), the lowest air temperature (r = 0.209) and daylight hours (r = 0.301). The higher air temperature was associated with higher ambulance transports of summer in Osaka area, Japan.展开更多
As part of a collaborative project,we took the window shutter—a widely used traditional facade element—and reinterpreted it for“adaptive”solutions using new,sustainable technologies.The aim was to design a modular...As part of a collaborative project,we took the window shutter—a widely used traditional facade element—and reinterpreted it for“adaptive”solutions using new,sustainable technologies.The aim was to design a modular construction kit that varies radiant energy,light and air flow to weather conditions and occupant requirements in new and existing residential and office buildings.展开更多
In underground space,daylighting plays an important role in increasing the spacious sense,improving the ventilation effect,and more importantly,reducing the negative visual and psychological effects brought by the und...In underground space,daylighting plays an important role in increasing the spacious sense,improving the ventilation effect,and more importantly,reducing the negative visual and psychological effects brought by the underground space,such as enclosed monotony,unknown direction and isolation.In this paper,the technical means of utilizing natural light in underground space were elaborated from the two aspects of passive daylighting method and active daylighting method,aiming to bring natural light into the underground as much as possible so as to fully satisfy people's longing for nature for those who work and live in the underground space.展开更多
Use of natural daylight in the building is energy saving with respect to illumination levels and health benefits.However in,the hot and dry climatic zone increase in daylight availability may result into thermal ingre...Use of natural daylight in the building is energy saving with respect to illumination levels and health benefits.However in,the hot and dry climatic zone increase in daylight availability may result into thermal ingress.This might lead to excess energy conservation.The aim of this paper is to evolve the methodology which could be used as a pre design tool for assessing the lighting provisions and thermal performance of spaces within buildings adopted by designers during the design process.The field measurements were conducted on the liveable spaces of a dwelling unit of the Nagpur region.Simulation studies using Ecotect Analysis 2011 was conducted for both illumination and thermal energy.The field measurements were compared with the simulated results.It has been found that the percentage difference(PD)between the Ecotect measurements(EM)and field measurements(FM)for both thermal loads and an illuminance level was less than 15%,the simulated model was considered precise for further study.The result imply that the simulated model would be ample for designers to evaluate the parameters associated to wall to window ratio,shading devices with respect to orientation of the building which helps to achieve the optimum useful daylight index.展开更多
It remains challenging to conduct an efficient dynamic façade design.In this article authors try to address this issue introducing the façade daylighting performance improvement(FDPI)indicator aimed to evalu...It remains challenging to conduct an efficient dynamic façade design.In this article authors try to address this issue introducing the façade daylighting performance improvement(FDPI)indicator aimed to evaluate the performance of a dynamic(adaptive)façade from its daylighting performance point of view.To illustrate the FDPI application the authors introduced the preliminary dynamic façade concept for an office building located in Tel Aviv(Hot-summer Mediterranean Climate Csa)with further shape modification based on the daylighting performance analysis compared to the three alternatives representative of different typologies of dynamic façades.Al Bahr,One Ocean and The University of Southern Denmark façade systems were simulated under the same weather and building conditions of the preliminary dynamic façade concept and were considered as a benchmark for the study.The final dynamic façade concept elaborated by the authors in the preliminary comparative workflow showed noticeable daylight performance improvement with respect to the case studies comparative scenarios.The FDPI metric allowed to estimate a daylighting performance improvement of 43%of the final dynamic façade concept over the case study dynamic façade that showed the best performance in the daylighting simulations.展开更多
Responsive facades can reduce building energy consumption and control daylight and natural ventilation to improve user comfort.This study aims to develop alternative responsive facade systems based on semi-regular and...Responsive facades can reduce building energy consumption and control daylight and natural ventilation to improve user comfort.This study aims to develop alternative responsive facade systems based on semi-regular and demi-regular tessellations.For this purpose,first,the tessellation method used to generate responsive facades is introduced.Then,the geometric and parametric design principles and the movement capabilities of the proposed facade systems are presented.Finally,a set of analyses are performed to test and compare the performances of the facade systems based on daylight metrics and indoor glare comfort.This study contributes to the literature with the proposed facade systems that can adapt to changing environmental conditions,provide flexibility in shape control and simplicity in mechanism design,and improve building performance.The analysis results show that all the proposed facade systems provide the desired visual comfort and daylight levels at different configurations.展开更多
文摘Various studies have suggested several environmental,pharmacological,medical,and optical interventions and some are in use but their efficacy in myopia control may be transient,and the cellular,molecular,and biochemical mechanisms involved unclear.Daylight exposure is currently regarded as an effective and enduring strategy in the control of myopia development and progression.However,the mechanism behind the effect of outdoor exposure and its association with genetic predisposition and other relatively more significant environmental factors on myopia is still a conundrum.This review focuses on survey-based and intervention-based studies carried out to propose a mechanism that accounts for myopia development and important for its control.
文摘The following article has been retracted due to the fact that it cannot be accepted as Duplicate Publication. The Editorial Board takes a very strong respect to the author’s situation on this matter. This paper published in Journal of Power and Energy Engineering Vol.3 No.4, April 2015, has been removed from this site.
文摘Daylight is a fundamental element to obtain built environments that promote environmental comfort and energy efficiency. However, strategies that enhance the building daylight performance can affect its thermal energetic performance. In this sense, research that addresses these aspects at the same time is considered essential. The objective of this paper was to evaluate the daylighting and thermal-energetic performance of administrative environments in a public institution, and to propose strategies that will enhance the use of daylight and lower energy consumption. Therefore, for future projects, and considering new buildings, and retrofit, this research will be an important reference. The research was developed through a case study of an administrative building model, in which the characteristics of solar orientation, light shelf use, glass type, and light and dark colors in walls were modified and combined, deriving it into models proposed. The daylighting performance evaluations were performed through dynamic simulation with the Rhinoceros for Diva software, and the thermal-energetic performance evaluations with the EnergyPlus software. The results of the work showed that a suitable solar orientation has a great impact on the automation of daylight and the energy consumption of the evaluated models, followed by the type of glass and the use of the light colors in internal walls, and that the use of artificial lighting with dimerization is fundamental as a complement to the daylight autonomy. For the boundary conditions of the study, the use of light shelves modified neither the daylight performance nor the thermal-energetic performance of the evaluated models.
文摘Currently, daylighting ducts system is widely used as a daylighting device. Generally, daylighting duct system efficiently takes light from outside during the day, and conveys daylight to required location through light duct manufactured by high reflectance mirror. Daylighting duct system can convey daylight to underground space that has no windows opening to external space. Daylighting system is composed of light collection part, light guide part and light emission part. Efficiency of daylighting system is depending on type of each part used in the system. However, it is very difficult to estimate exact light flow in the system considering type of the parts. Authors performed measurement experiments to make clear the light flow with real-size model and miniature model of daylighting duct system. We discussed effect of type of the parts on efficiency of daylighting duct system.
文摘Different approaches have been introduced for the daylighting system to reduce energy consumption, but they were not populated due to complex, high cost, and insufficient designs. There has been a recent problem in achieving uniform distribution of sunlight at a destination deep inside the building. Therefore, we propose a system to achieve high illumination by illuminating the surface of the absorber (optical fibers) uniformly. To capture sunlight, parabolic reflector and Fresnel lens are used. Different reflectors and lenses are considered, compared, and investigated to direct uniform light, which solves the heat problem, into the optical fibers. In addition, this study includes comparison between fiber-based daylighting systems. The proposed system has been verified through simulation and experimental results.
文摘In the subtropical zone of China, a large number of old factory buildings rich in industrial historical and cultural value have been transformed into art studios. In the existing research on building renovation, there are still problems such as insufficient lighting, low uniformity, and ignoring the effect of glare in the lighting environment of buildings after transformation. To fill this research gap, this paper provides a daylighting design strategy for these factory buildings in subtropical zones to ensure that the transformed art studios can offer an excellent indoor daylighting environment. Through the control variable method, the window-to-wall ratio, the form of external windows, and the visible light transmittance of glass are set with quantitative and variable values, and a design strategy that meets the requirements of international general daylighting standards is obtained step by step through the simulation. The daylight factor, uniformity, daylight autonomy, and dynamic glare probability are used in this research process to measure whether the daylighting strategy meets the daylighting requirements of the CIBSE Lighting Guide for art studios. The results show that the average indoor lighting coefficient can be increased from 1.29 to 6.18, and the minimum value of the lighting coefficient can be increased from 0.4 to 4.4 by enlarging the windowed wall ratio from 1:30 to 1:3, using the combination method of the horizontal window, skylight and skylight recommended by the analysis results, and selecting veneer glass with 88% transmittance. This allows for better uniform lighting inside the building and reduces glare. This conclusion can support the lighting performance design of industrial buildings in the future.
基金Project(2006BAJ02A02) supported by the National Key Technologies R & D Program of China
文摘At the scheme design stage,the potential of daylighting is significant due to the saving for electric lighting use. There are few simple tools for architects to optimize the daylighting design. Therefore,it is useful to develop a design guideline related to the evaluation of lighting energy saving potential and sunlight design strategies. This paper analyzes the impacts of different artificial lighting control methods and design parameters on daylighting. A direct correlation between lighting energy consumption and parameters such as orientations,window to wall ratio (WWR) and perimeter depth is established. A simplified prediction model is proposed to estimate lighting energy consumption with the given perimeter depth,WWR,and window transparency. Validation of the model is carried out compared with detailed lighting simulation software for an office building. After the variation analysis for these parameters,design advises for the daylighting design at scheme design phase are summarized.
基金Sponsored by the National Project of Scientific and Technical Supporting Programs Funded by Ministry of Science & Technology of China (Grant No.2012BAJ06B04-02)
文摘This paper presents a comprehensive survey for the situation of light environment in large commercial building through architecture design information,subjective and objective fieldwork and online survey for three typical commercial building forms( centralized form, covered mall shopping center, lifestyle center).Descriptive method is used for statistical analysis which includes the evaluation of light environmental quality,subjective assessment among daylight and artificial illumination,effect of physical characteristics on subjective assessment of light environment. Based on the results of statistical analysis,the improving strategies for light environment are proposed in terms of making use of daylight,artificial lighting design and improvement of the overall light environmental quality. The design strategies which based on the consumer needs is very important can provide help for further impact prediction on the quality of light environment.
文摘We investigated the link between ambulance transports and meteorological parameters of summer by using daily data in Osaka area, Japan. Daily observations for ambulance transports (from July 1 to September 30, 2009) were obtained from Fire Department Service in Osaka. Data of meteorological parameters in Osaka area, Japan (from July 1 to September 30, 2009) were also obtained from Japan Meteorological Agency. Effect of meteorological parameters on ambulance transports was analyzed. A total of 49,526 ambulance transports were observed from July 1 to September 30, 2009 in Osaka, Japan. Ambulance transports were significantly correlated with mean air temperature (r = 0.298), the highest air temperature (r = 0.347), the lowest air temperature (r = 0.209) and daylight hours (r = 0.301). The higher air temperature was associated with higher ambulance transports of summer in Osaka area, Japan.
文摘As part of a collaborative project,we took the window shutter—a widely used traditional facade element—and reinterpreted it for“adaptive”solutions using new,sustainable technologies.The aim was to design a modular construction kit that varies radiant energy,light and air flow to weather conditions and occupant requirements in new and existing residential and office buildings.
文摘In underground space,daylighting plays an important role in increasing the spacious sense,improving the ventilation effect,and more importantly,reducing the negative visual and psychological effects brought by the underground space,such as enclosed monotony,unknown direction and isolation.In this paper,the technical means of utilizing natural light in underground space were elaborated from the two aspects of passive daylighting method and active daylighting method,aiming to bring natural light into the underground as much as possible so as to fully satisfy people's longing for nature for those who work and live in the underground space.
文摘Use of natural daylight in the building is energy saving with respect to illumination levels and health benefits.However in,the hot and dry climatic zone increase in daylight availability may result into thermal ingress.This might lead to excess energy conservation.The aim of this paper is to evolve the methodology which could be used as a pre design tool for assessing the lighting provisions and thermal performance of spaces within buildings adopted by designers during the design process.The field measurements were conducted on the liveable spaces of a dwelling unit of the Nagpur region.Simulation studies using Ecotect Analysis 2011 was conducted for both illumination and thermal energy.The field measurements were compared with the simulated results.It has been found that the percentage difference(PD)between the Ecotect measurements(EM)and field measurements(FM)for both thermal loads and an illuminance level was less than 15%,the simulated model was considered precise for further study.The result imply that the simulated model would be ample for designers to evaluate the parameters associated to wall to window ratio,shading devices with respect to orientation of the building which helps to achieve the optimum useful daylight index.
基金the Ministry of Science and Higher Education of the Russian Federation as part of the World-class Research Center program:Advanced Digital Technologies(contract No.075-15-2022-311 dated 20 April 2022).
文摘It remains challenging to conduct an efficient dynamic façade design.In this article authors try to address this issue introducing the façade daylighting performance improvement(FDPI)indicator aimed to evaluate the performance of a dynamic(adaptive)façade from its daylighting performance point of view.To illustrate the FDPI application the authors introduced the preliminary dynamic façade concept for an office building located in Tel Aviv(Hot-summer Mediterranean Climate Csa)with further shape modification based on the daylighting performance analysis compared to the three alternatives representative of different typologies of dynamic façades.Al Bahr,One Ocean and The University of Southern Denmark façade systems were simulated under the same weather and building conditions of the preliminary dynamic façade concept and were considered as a benchmark for the study.The final dynamic façade concept elaborated by the authors in the preliminary comparative workflow showed noticeable daylight performance improvement with respect to the case studies comparative scenarios.The FDPI metric allowed to estimate a daylighting performance improvement of 43%of the final dynamic façade concept over the case study dynamic façade that showed the best performance in the daylighting simulations.
文摘Responsive facades can reduce building energy consumption and control daylight and natural ventilation to improve user comfort.This study aims to develop alternative responsive facade systems based on semi-regular and demi-regular tessellations.For this purpose,first,the tessellation method used to generate responsive facades is introduced.Then,the geometric and parametric design principles and the movement capabilities of the proposed facade systems are presented.Finally,a set of analyses are performed to test and compare the performances of the facade systems based on daylight metrics and indoor glare comfort.This study contributes to the literature with the proposed facade systems that can adapt to changing environmental conditions,provide flexibility in shape control and simplicity in mechanism design,and improve building performance.The analysis results show that all the proposed facade systems provide the desired visual comfort and daylight levels at different configurations.