This study investigated the feasibility of distance protection in extra-high voltage(EHV) networks. In long-distance transmission lines, the distributed parameter characteristic of the EHV network is obvious. When a f...This study investigated the feasibility of distance protection in extra-high voltage(EHV) networks. In long-distance transmission lines, the distributed parameter characteristic of the EHV network is obvious. When a fault occurs far away from the measurement site, the measured impedance might not be directly proportional to the fault distance, and the protection domain of distance protection will be decreased. The detailed theory inferred and proven in this paper reveals that this phenomenon is widespread in EHV transmission lines. The results indicate that the protection domain error is greatly reduced by the application of the shunt reactor. Overall, simulation results show that the proposed method is effective for impedance relay, considering different characteristics, different lengths of lines, and compensation degrees.展开更多
To observe the inner operating process of distance protection,a Matlab/Simulink based dynamic simulation system for microprocessor-based distance protection is designed in this paper.As a modularized design,the simula...To observe the inner operating process of distance protection,a Matlab/Simulink based dynamic simulation system for microprocessor-based distance protection is designed in this paper.As a modularized design,the simulation system is composed of several modules such as fault transient calculation,startup,Fourier algorithm,phase selection,impedance computing and impedance comparison etc.Some typical simulation cases,which focus on the main factors affecting distance relay's operation,have been simulated with the system.Simulation results show that the system is able to demonstrate the dynamic behaviors of distance protection under different operating conditions.展开更多
Nowadays wind energy is the fastest growing renewable energy resource in the world.The problems of integrating wind farms are caused by changes of wind speed during a day.Moreover,the behaviors of wind turbines equipp...Nowadays wind energy is the fastest growing renewable energy resource in the world.The problems of integrating wind farms are caused by changes of wind speed during a day.Moreover,the behaviors of wind turbines equipped with doubly-fed induction generators differ fundamentally from synchronous generators.Therefore,more considerations are needed to analyze the performances of the distance protection relays.The protection of a wind farm with distance relay is inspected.By changing the conditions of the wind farm,the characteristics of the distance relay are studied.展开更多
This paper proposed the scheme of transmission lines distance protection based on differential equation algorithms (DEA) and Hilbert-Huang transform (HHT). The measured impedance based on EDA is affected by various fa...This paper proposed the scheme of transmission lines distance protection based on differential equation algorithms (DEA) and Hilbert-Huang transform (HHT). The measured impedance based on EDA is affected by various factors, such as the distributed capacitance, the transient response characteristics of current transformer and voltage transformer, etc. In order to overcome this problem, the proposed scheme applies HHT to improve the apparent impedance estimated by DEA. Empirical mode decomposition (EMD) is used to decompose the data set from DEA into the intrinsic mode functions (IMF) and the residue. This residue has monotonic trend and is used to evaluate the impedance of faulty line. Simulation results show that the proposed scheme improves significantly the accuracy of the estimated impedance.展开更多
The system impedance instability,high-order harmonics,and frequency offset are main fault characteristics of wind power system.Moreover,the measurement angle of faulty phase is affected by rotation speed frequency co...The system impedance instability,high-order harmonics,and frequency offset are main fault characteristics of wind power system.Moreover,the measurement angle of faulty phase is affected by rotation speed frequency component,which causes traditional directional protections based on angle comparison between voltage and current to operate incorrectly.In this paper,a time-domain protection for connected to wind power plant based on model matching is proposed,which compares the calculated current and the measured current to identify internal faults and external faults.Under external faults,the calculated current and measured current waveform are quite similar because the protected transmission lines is equivalent to a lumped parameter model and the model itself is not damaged.However,the similarity of calculated current and measured current is quite low,due to destroyed integrity of model under internal faults.Additionally,Hausdorff distance is introduced to obtain the similarity of the calculated current and measured current.Since the proposed protection scheme is applied in time domain,it is independent from current frequency offsets of wind energy system,high-order harmonics,and system impedance variations.Comprehensive case studies are undertaken through Power Systems Computer Aided Design(PSCAD),while simulation results verify the accuracy and efficiency of the proposed approach in fault identification.展开更多
Saving the electrical power system in stable condition is considered as one of important challenges to avoid any failure of high voltage equipment. Additionally, with the increasing off the critical loads, it’s very ...Saving the electrical power system in stable condition is considered as one of important challenges to avoid any failure of high voltage equipment. Additionally, with the increasing off the critical loads, it’s very important to use the accurate protection system that can deal with any abnormal condition. This paper studies one of critical cases that can effect on the coordination of the protection system with the faults during fuse fail condition. Over Head transmission line (OHTL) is the most part in the power system that faces the disturbances, which can be protected by multi-protection functions as line differential function, distance protection function, over current, earth fault, over/under voltage etc. The distance protection function is depending on the line voltage and the load current to calculate the load zone. This paper aims to prevent the falls operation of distance protection function during voltage transformer fuse failure condition.展开更多
The change processes and trends of shoreline and tidal flat forced by human activities are essential issues for the sustainability of coastal area,which is also of great significance for understanding coastal ecologic...The change processes and trends of shoreline and tidal flat forced by human activities are essential issues for the sustainability of coastal area,which is also of great significance for understanding coastal ecological environment changes and even global changes.Based on field measurements,combined with Linear Regression(LR)model and Inverse Distance Weighing(IDW)method,this paper presents detailed analysis on the change history and trend of the shoreline and tidal flat in Bohai Bay.The shoreline faces a high erosion chance under the action of natural factors,while the tidal flat faces a different erosion and deposition patterns in Bohai Bay due to the impact of human activities.The implication of change rule for ecological protection and recovery is also discussed.Measures should be taken to protect the coastal ecological environment.The models used in this paper show a high correlation coefficient between observed and modeling data,which means that this method can be used to predict the changing trend of shoreline and tidal flat.The research results of present study can provide scientific supports for future coastal protection and management.展开更多
As an effective approach to achieve the“dual-carbon”goal,the grid-connected capacity of renewable energy increases constantly.Photovoltaics are the most widely used renewable energy sources and have been applied on ...As an effective approach to achieve the“dual-carbon”goal,the grid-connected capacity of renewable energy increases constantly.Photovoltaics are the most widely used renewable energy sources and have been applied on various occasions.However,the inherent randomness,intermittency,and weak support of grid-connected equipment not only cause changes in the original flow characteristics of the grid but also result in complex fault characteristics.Traditional overcurrent and differential protection methods cannot respond accurately due to the effects of unknown renewable energy sources.Therefore,a longitudinal protection method based on virtual measurement of current restraint is proposed in this paper.The positive sequence current data and the network parameters are used to calculate the virtual measurement current which compensates for the output current of photovoltaic(PV).The waveform difference between the virtual measured current and the terminal current for internal and external faults is used to construct the protection method.An improved edit distance algorithm is proposed to measure the similarity between virtual measurement current and terminal measurement current.Finally,the feasibility of the protection method is verified through PSCAD simulation.展开更多
According to the specific geological condition, analyzed the stress distribution of the overlying strata, the displacement of pressure released seam, thickness variation and the distribution of plastic zones by FLAG3D...According to the specific geological condition, analyzed the stress distribution of the overlying strata, the displacement of pressure released seam, thickness variation and the distribution of plastic zones by FLAG3D software to simulate mining of the long-distance lower protective seam. The research results show that the distribution of vertical stress appears as a "Double-hump" within the pressure-relief range of the protected coal seam and the swelling deformation curve of coal bodies takes an "M" shape. The swelling is divided into initial swelling, swelling increase and swelling compression stability. The maximum swelling ratio of the pressure released seam is 1.84%, protection angle of the lower protective coal seam along the strike direction is about 55°, protection angle below the dip direction is about 50°, protection angle above the dip direction is about 55°, and the coal seam compression zone resembles a "U" shape.展开更多
This paper presents a technique that increases the second-zone coverage of distance relays without causing overreach problems. The technique is based on the impedance seen by distance relays when faults are simulated ...This paper presents a technique that increases the second-zone coverage of distance relays without causing overreach problems. The technique is based on the impedance seen by distance relays when faults are simulated on the reach of zone-1 relays. The approach checks the relay operation for the maximum as well as the minimum generation outputs of the power system. The proposed technique can be used for different reach setting for zone-1. Results show that it is possible to increase the coverage provided by zone-2 distance relays without causing coordination problems with the primary relays that protect the lines emanating from the remote bus. The proposed method is modified for use in an adaptive protection system. It is shown that further improvements can be achieved when settings are calculated using the proposed method and the prevailing system conditions. The proposed method and its adaptive version were applied to a part of the Power system. The simulation of the system is done by using PSCAD-EMTDC software. The simulated results are observed and compared with the conventional and proposed technique.展开更多
The development of a computer program for evaluation of lightning safety distance between the tower and satellite dish is written in M-File MATLAB. The 3-dimensional illustrative graphics model is used to capture bett...The development of a computer program for evaluation of lightning safety distance between the tower and satellite dish is written in M-File MATLAB. The 3-dimensional illustrative graphics model is used to capture better understanding on how lightning protection system (LPS) works. The study of physical length of grounding electrode used on the tower is found to be significantly affecting the grounding system performances where they depend on magnitude of dispersed lightning strikes current and the settling time for the current to completely disperse. The grounding system performance is studied by using lightning impulse current (LIC) generator, simulated in OrCad PSpice software. It is found that the optimum length of vertical lightning rod in LPS is the same with the striking distance. There is no significant improvement is observed in lightning safety distance if the length of vertical lightning rod is higher than striking distance. The lightning strike peak current that has larger magnitude than the withstanding insulation level of specified object causes no physical damage. It is because the lightning safety distance increases when the lightning strike peak current becomes higher. It is also found that the lower grounding impedance generates higher magnitude of dispersed peak current and faster settling time.展开更多
Power swing evoked by sudden changes like faults or switching operations will become more and more important for protective relaying, due to the growing load flow in electrical power networks. Unwanted trips of the di...Power swing evoked by sudden changes like faults or switching operations will become more and more important for protective relaying, due to the growing load flow in electrical power networks. Unwanted trips of the distance protection function must be avoided to prevent cascading effects and blackouts in the network. Selective out-of-step-tripping is required to stop unstable power swing and to prevent damage to affected generators. Therefore a reliable method for detection of power swing is presented, which requires no settings for operation. Power swing can be detected from 0.1 Hz up to 10 Hz swing frequency, also during open pole condition and during asymmetrical operation. A blocking logic prevents unselective trips by the distance protection. However, faults that occur during a power swing must be detected and cleared with a high degree of selectivity and dependability. For unstable power swing a flexible out of step tripping function will be proposed. The coordination of power swing detection, distance protection and out of step protection provides a reliable system protection.展开更多
In order to solve the problems of insufficient training equipment,relatively lack of curriculum resources and single teaching means in the teaching of UAV(unmanned aerial vehicle)applied technology major,this paper st...In order to solve the problems of insufficient training equipment,relatively lack of curriculum resources and single teaching means in the teaching of UAV(unmanned aerial vehicle)applied technology major,this paper studies the application of MR(Mixed Reality)in UAV applied technology major teaching,with the teaching of UAV agriculture&forestry plant protection curriculum as the carrier.The study will solve the pain points in teaching,improve the teaching ability and teaching information level,and increase the talent training quality of UAV,agriculture&forestry plant protection and related majors.Furthermore,it will create a protective,interactive,remote and scalable teaching experience for stu-dents,which can improve the teaching effect and reduce the teaching cost.展开更多
The paper has presented the impact on the line protection performance with the introduction of MUs (merging units) in the process bus level. The paper begins with the introduction on modem digital substation structu...The paper has presented the impact on the line protection performance with the introduction of MUs (merging units) in the process bus level. The paper begins with the introduction on modem digital substation structure and process bus. Then, the paper describes the performances of different sensors such as CTs (current transformers), CVTs (capacitive voltage transformers), FOCS (fiber optical current transducers) and FOVS (fiber optical voltage transducers). With the use of above transducers together with MUs, the performance of distance protection function and line differential protection function have been investigated and presented. Finally, conclusions based on the study are presented in the paper.展开更多
A hybrid UHVDC transmission system applying LCC as the rectifier and MMC as the inverter combines the advantages of both converter types,which makes this protection scheme more complicated.A new pilot protection schem...A hybrid UHVDC transmission system applying LCC as the rectifier and MMC as the inverter combines the advantages of both converter types,which makes this protection scheme more complicated.A new pilot protection scheme for a three-terminal hybrid DC transmission system applying energy functions is proposed.The energy function for LCC is applied to MMC to derive the energy level of the hybrid system.Furthermore,an improved Hausdorff distance(IHD)algorithm is proposed to detect the difference in energy levels between the normal and fault states.An abrupt change in energy level is characterized by IHD change rate.Time points at which the IHD change rate exceeds the threshold at converter stations are applied to determine the fault line and to estimate the fault section.The proposed protection scheme is then verified by a simulation model of the Wudongde±800 kV three-terminal hybrid UHVDC transmission project.The appropriate sampling frequency is selected for a real-time calculation,and the threshold is selected considering the effect of noise.Results show the proposed scheme can identify and trip fault lines quickly and effectively,even for a 600Ωgrounding fault.Other waveshape similarity algorithms are compared and analyzed.Compared with existing protection schemes,the proposed scheme transmits less data to improve communication speed and reliability.展开更多
The distributed capacitance of the line becomes larger as the scale of wind farms,the transmission voltage level,and the transmission distance increase.Hence,the error of the traditional time-domain distance protectio...The distributed capacitance of the line becomes larger as the scale of wind farms,the transmission voltage level,and the transmission distance increase.Hence,the error of the traditional time-domain distance protection scheme based on the R-L model,which ignores the distributed capacitance of the line,becomes unacceptable.Therefore,the error of the time-domain fault location method based on the R-L model,especially the maximum error range,is theoretically analyzed in this paper.On this basis,a novel fault location method based on the RL and Bergeron models is proposed.Then,a fast time-domain distance protection scheme is designed.In the proposed scheme,the error in the fitting calculation is used to construct a weight matrix,and an algorithm for solving the time-domain differential equations is designed to improve the calculation speed and stability.Compared with the traditional frequency-domain distance protection scheme,the proposed scheme is independent of the power supply characteristics;thus,it is suitable for wind farm transmission lines.In addition,compared with the traditional method based on the R-L model,the proposed scheme effectively avoids the negative influence of the distributed capacitance of the line,which significantly improves the operating speed.Different types of faults are simulated by PSCAD/EMTDC to verify the effectiveness and superiority of the proposed scheme.展开更多
Protection distance of surge protective devices (SPDs) is an important problem in designing a good location scheme of SPDs in low voltage distribution systems for protecting electrical equipments against over- voltage...Protection distance of surge protective devices (SPDs) is an important problem in designing a good location scheme of SPDs in low voltage distribution systems for protecting electrical equipments against over- voltage caused by lightning stroke. The simplified lumped-parameter circuit model and the circuit method were used to study the protection distance problem of SPDs. The analytical solutions of the load voltage and general equations of the protection distance of SPDs under different load conditions were given. Simulation results of examples proved the validity of the proposed analytical method.展开更多
Conventional transmission line distance protection approaches are subject to malfunction under reverse fault-induced current transformer(CT) saturation for the typically employed breaker-and-a-half configuration. This...Conventional transmission line distance protection approaches are subject to malfunction under reverse fault-induced current transformer(CT) saturation for the typically employed breaker-and-a-half configuration. This paper addresses this issue by proposing a new distance protection approach that combines the blocking and unblocking criteria of distance protection based on the values of incomplete differential current,operation voltage, and current harmonic content. The proposed approach is verified by theoretical analysis, dynamic simulation testing, and field operation to ensure that the obtained distance protection is reliable and refrains from operating unnecessarily under reverse fault-induced CT saturation in the breaker-and-ahalf configuration. Meanwhile, the proposed approach is demonstrated can operate reliably when forward faults occur or various reverse faults are converted to forward faults.展开更多
The active saturated iron-core superconductive fault current limiter(SISFCL)is a good choice to decrease fault current.This paper introduced the principles and impedance characteristic of the active SISFCL.Then,it sho...The active saturated iron-core superconductive fault current limiter(SISFCL)is a good choice to decrease fault current.This paper introduced the principles and impedance characteristic of the active SISFCL.Then,it shows the current-limiting effects of the SISFCL.Besides,the impact of the active SISFCL on the distance protection of the EHV transmission line is evaluated.Based on that,the coordination scheme of the distance protections is proposed.A 500 kV double-circuit transmission system with SISFCLs is simulated by Electro-Magnetic Transients Program including DC(EMTDC).Simulation tests demonstrate the correctness and validity of theoretical analyses.展开更多
To ensure the mining safety of working face in the protective seam and meanwhile extract pressure-relief gas of the lower protected seam and eliminate its outburst risk,the present study researched into fracture devel...To ensure the mining safety of working face in the protective seam and meanwhile extract pressure-relief gas of the lower protected seam and eliminate its outburst risk,the present study researched into fracture development of floor coal-rock mass of the protective seam and migration rule of pressure-relief gas from a protected seam so as to obtain an effective pressure- relief gas extraction method.The results show that after the upper protective seam was mined,mining-induced fracturing floor coal-rock mas...展开更多
文摘This study investigated the feasibility of distance protection in extra-high voltage(EHV) networks. In long-distance transmission lines, the distributed parameter characteristic of the EHV network is obvious. When a fault occurs far away from the measurement site, the measured impedance might not be directly proportional to the fault distance, and the protection domain of distance protection will be decreased. The detailed theory inferred and proven in this paper reveals that this phenomenon is widespread in EHV transmission lines. The results indicate that the protection domain error is greatly reduced by the application of the shunt reactor. Overall, simulation results show that the proposed method is effective for impedance relay, considering different characteristics, different lengths of lines, and compensation degrees.
基金National Natural Science Foundation of China(No.50777040)
文摘To observe the inner operating process of distance protection,a Matlab/Simulink based dynamic simulation system for microprocessor-based distance protection is designed in this paper.As a modularized design,the simulation system is composed of several modules such as fault transient calculation,startup,Fourier algorithm,phase selection,impedance computing and impedance comparison etc.Some typical simulation cases,which focus on the main factors affecting distance relay's operation,have been simulated with the system.Simulation results show that the system is able to demonstrate the dynamic behaviors of distance protection under different operating conditions.
文摘Nowadays wind energy is the fastest growing renewable energy resource in the world.The problems of integrating wind farms are caused by changes of wind speed during a day.Moreover,the behaviors of wind turbines equipped with doubly-fed induction generators differ fundamentally from synchronous generators.Therefore,more considerations are needed to analyze the performances of the distance protection relays.The protection of a wind farm with distance relay is inspected.By changing the conditions of the wind farm,the characteristics of the distance relay are studied.
文摘This paper proposed the scheme of transmission lines distance protection based on differential equation algorithms (DEA) and Hilbert-Huang transform (HHT). The measured impedance based on EDA is affected by various factors, such as the distributed capacitance, the transient response characteristics of current transformer and voltage transformer, etc. In order to overcome this problem, the proposed scheme applies HHT to improve the apparent impedance estimated by DEA. Empirical mode decomposition (EMD) is used to decompose the data set from DEA into the intrinsic mode functions (IMF) and the residue. This residue has monotonic trend and is used to evaluate the impedance of faulty line. Simulation results show that the proposed scheme improves significantly the accuracy of the estimated impedance.
基金This paper is supported in part by the National Natural Science Foundations of China under Grant Nos.51977102 and 51807084.
文摘The system impedance instability,high-order harmonics,and frequency offset are main fault characteristics of wind power system.Moreover,the measurement angle of faulty phase is affected by rotation speed frequency component,which causes traditional directional protections based on angle comparison between voltage and current to operate incorrectly.In this paper,a time-domain protection for connected to wind power plant based on model matching is proposed,which compares the calculated current and the measured current to identify internal faults and external faults.Under external faults,the calculated current and measured current waveform are quite similar because the protected transmission lines is equivalent to a lumped parameter model and the model itself is not damaged.However,the similarity of calculated current and measured current is quite low,due to destroyed integrity of model under internal faults.Additionally,Hausdorff distance is introduced to obtain the similarity of the calculated current and measured current.Since the proposed protection scheme is applied in time domain,it is independent from current frequency offsets of wind energy system,high-order harmonics,and system impedance variations.Comprehensive case studies are undertaken through Power Systems Computer Aided Design(PSCAD),while simulation results verify the accuracy and efficiency of the proposed approach in fault identification.
文摘Saving the electrical power system in stable condition is considered as one of important challenges to avoid any failure of high voltage equipment. Additionally, with the increasing off the critical loads, it’s very important to use the accurate protection system that can deal with any abnormal condition. This paper studies one of critical cases that can effect on the coordination of the protection system with the faults during fuse fail condition. Over Head transmission line (OHTL) is the most part in the power system that faces the disturbances, which can be protected by multi-protection functions as line differential function, distance protection function, over current, earth fault, over/under voltage etc. The distance protection function is depending on the line voltage and the load current to calculate the load zone. This paper aims to prevent the falls operation of distance protection function during voltage transformer fuse failure condition.
基金supported by the National Natural Science Foundation of China (41602205, 42293261)the China Geological Survey Program (DD20189506, DD20211301)+2 种基金the Special Investigation Project on Science and Technology Basic Resources of the Ministry of Science and Technology (2021FY101003)the Central Guidance for Local Scientific and Technological Development Fund of 2023the Project of Hebei University of Environmental Engineering (GCY202301)
文摘The change processes and trends of shoreline and tidal flat forced by human activities are essential issues for the sustainability of coastal area,which is also of great significance for understanding coastal ecological environment changes and even global changes.Based on field measurements,combined with Linear Regression(LR)model and Inverse Distance Weighing(IDW)method,this paper presents detailed analysis on the change history and trend of the shoreline and tidal flat in Bohai Bay.The shoreline faces a high erosion chance under the action of natural factors,while the tidal flat faces a different erosion and deposition patterns in Bohai Bay due to the impact of human activities.The implication of change rule for ecological protection and recovery is also discussed.Measures should be taken to protect the coastal ecological environment.The models used in this paper show a high correlation coefficient between observed and modeling data,which means that this method can be used to predict the changing trend of shoreline and tidal flat.The research results of present study can provide scientific supports for future coastal protection and management.
基金funded by State Grid Anhui Electric Power Co.,Ltd.Science and Technology Project(52120021N00L)the National Key Research and Development Program of China(2022YFB2400015).
文摘As an effective approach to achieve the“dual-carbon”goal,the grid-connected capacity of renewable energy increases constantly.Photovoltaics are the most widely used renewable energy sources and have been applied on various occasions.However,the inherent randomness,intermittency,and weak support of grid-connected equipment not only cause changes in the original flow characteristics of the grid but also result in complex fault characteristics.Traditional overcurrent and differential protection methods cannot respond accurately due to the effects of unknown renewable energy sources.Therefore,a longitudinal protection method based on virtual measurement of current restraint is proposed in this paper.The positive sequence current data and the network parameters are used to calculate the virtual measurement current which compensates for the output current of photovoltaic(PV).The waveform difference between the virtual measured current and the terminal current for internal and external faults is used to construct the protection method.An improved edit distance algorithm is proposed to measure the similarity between virtual measurement current and terminal measurement current.Finally,the feasibility of the protection method is verified through PSCAD simulation.
基金Supported by the Basic Research Program of National Natural Science Foundation of China(50834005)
文摘According to the specific geological condition, analyzed the stress distribution of the overlying strata, the displacement of pressure released seam, thickness variation and the distribution of plastic zones by FLAG3D software to simulate mining of the long-distance lower protective seam. The research results show that the distribution of vertical stress appears as a "Double-hump" within the pressure-relief range of the protected coal seam and the swelling deformation curve of coal bodies takes an "M" shape. The swelling is divided into initial swelling, swelling increase and swelling compression stability. The maximum swelling ratio of the pressure released seam is 1.84%, protection angle of the lower protective coal seam along the strike direction is about 55°, protection angle below the dip direction is about 50°, protection angle above the dip direction is about 55°, and the coal seam compression zone resembles a "U" shape.
文摘This paper presents a technique that increases the second-zone coverage of distance relays without causing overreach problems. The technique is based on the impedance seen by distance relays when faults are simulated on the reach of zone-1 relays. The approach checks the relay operation for the maximum as well as the minimum generation outputs of the power system. The proposed technique can be used for different reach setting for zone-1. Results show that it is possible to increase the coverage provided by zone-2 distance relays without causing coordination problems with the primary relays that protect the lines emanating from the remote bus. The proposed method is modified for use in an adaptive protection system. It is shown that further improvements can be achieved when settings are calculated using the proposed method and the prevailing system conditions. The proposed method and its adaptive version were applied to a part of the Power system. The simulation of the system is done by using PSCAD-EMTDC software. The simulated results are observed and compared with the conventional and proposed technique.
文摘The development of a computer program for evaluation of lightning safety distance between the tower and satellite dish is written in M-File MATLAB. The 3-dimensional illustrative graphics model is used to capture better understanding on how lightning protection system (LPS) works. The study of physical length of grounding electrode used on the tower is found to be significantly affecting the grounding system performances where they depend on magnitude of dispersed lightning strikes current and the settling time for the current to completely disperse. The grounding system performance is studied by using lightning impulse current (LIC) generator, simulated in OrCad PSpice software. It is found that the optimum length of vertical lightning rod in LPS is the same with the striking distance. There is no significant improvement is observed in lightning safety distance if the length of vertical lightning rod is higher than striking distance. The lightning strike peak current that has larger magnitude than the withstanding insulation level of specified object causes no physical damage. It is because the lightning safety distance increases when the lightning strike peak current becomes higher. It is also found that the lower grounding impedance generates higher magnitude of dispersed peak current and faster settling time.
文摘Power swing evoked by sudden changes like faults or switching operations will become more and more important for protective relaying, due to the growing load flow in electrical power networks. Unwanted trips of the distance protection function must be avoided to prevent cascading effects and blackouts in the network. Selective out-of-step-tripping is required to stop unstable power swing and to prevent damage to affected generators. Therefore a reliable method for detection of power swing is presented, which requires no settings for operation. Power swing can be detected from 0.1 Hz up to 10 Hz swing frequency, also during open pole condition and during asymmetrical operation. A blocking logic prevents unselective trips by the distance protection. However, faults that occur during a power swing must be detected and cleared with a high degree of selectivity and dependability. For unstable power swing a flexible out of step tripping function will be proposed. The coordination of power swing detection, distance protection and out of step protection provides a reliable system protection.
基金Supported by Vocational Education Reform and Innovation Project of Ministry of Education(HBKC217166,HBKC217168)Teaching Reform Project of Agricultural Specialty Teaching Steering Committee of Higher Vocational Education in Guangdong Province(YNYJZW2019YB09)+1 种基金Special Higher Vocational Enrollment Expansion Project of Teaching Reform Research and Practice Pro-ject in Guangdong Province(JGGZKZ2020141)Special Fund for Rural Revitalization Strategy of Huizhou in 2021(2021SC010502002)
文摘In order to solve the problems of insufficient training equipment,relatively lack of curriculum resources and single teaching means in the teaching of UAV(unmanned aerial vehicle)applied technology major,this paper studies the application of MR(Mixed Reality)in UAV applied technology major teaching,with the teaching of UAV agriculture&forestry plant protection curriculum as the carrier.The study will solve the pain points in teaching,improve the teaching ability and teaching information level,and increase the talent training quality of UAV,agriculture&forestry plant protection and related majors.Furthermore,it will create a protective,interactive,remote and scalable teaching experience for stu-dents,which can improve the teaching effect and reduce the teaching cost.
文摘The paper has presented the impact on the line protection performance with the introduction of MUs (merging units) in the process bus level. The paper begins with the introduction on modem digital substation structure and process bus. Then, the paper describes the performances of different sensors such as CTs (current transformers), CVTs (capacitive voltage transformers), FOCS (fiber optical current transducers) and FOVS (fiber optical voltage transducers). With the use of above transducers together with MUs, the performance of distance protection function and line differential protection function have been investigated and presented. Finally, conclusions based on the study are presented in the paper.
基金supported by the Science and Technology Project of China Southern Power Co.,Ltd.(CGYKJXM20180508).
文摘A hybrid UHVDC transmission system applying LCC as the rectifier and MMC as the inverter combines the advantages of both converter types,which makes this protection scheme more complicated.A new pilot protection scheme for a three-terminal hybrid DC transmission system applying energy functions is proposed.The energy function for LCC is applied to MMC to derive the energy level of the hybrid system.Furthermore,an improved Hausdorff distance(IHD)algorithm is proposed to detect the difference in energy levels between the normal and fault states.An abrupt change in energy level is characterized by IHD change rate.Time points at which the IHD change rate exceeds the threshold at converter stations are applied to determine the fault line and to estimate the fault section.The proposed protection scheme is then verified by a simulation model of the Wudongde±800 kV three-terminal hybrid UHVDC transmission project.The appropriate sampling frequency is selected for a real-time calculation,and the threshold is selected considering the effect of noise.Results show the proposed scheme can identify and trip fault lines quickly and effectively,even for a 600Ωgrounding fault.Other waveshape similarity algorithms are compared and analyzed.Compared with existing protection schemes,the proposed scheme transmits less data to improve communication speed and reliability.
基金supported by the Science and Technology Program of State Grid Corporation of China“Research on the Principle of Fast Protection in Time-frequency Domain with Single-ended Quantities of High-proportion New Energy Grid Lines”(No.5100-202040327A-0-0-00).
文摘The distributed capacitance of the line becomes larger as the scale of wind farms,the transmission voltage level,and the transmission distance increase.Hence,the error of the traditional time-domain distance protection scheme based on the R-L model,which ignores the distributed capacitance of the line,becomes unacceptable.Therefore,the error of the time-domain fault location method based on the R-L model,especially the maximum error range,is theoretically analyzed in this paper.On this basis,a novel fault location method based on the RL and Bergeron models is proposed.Then,a fast time-domain distance protection scheme is designed.In the proposed scheme,the error in the fitting calculation is used to construct a weight matrix,and an algorithm for solving the time-domain differential equations is designed to improve the calculation speed and stability.Compared with the traditional frequency-domain distance protection scheme,the proposed scheme is independent of the power supply characteristics;thus,it is suitable for wind farm transmission lines.In addition,compared with the traditional method based on the R-L model,the proposed scheme effectively avoids the negative influence of the distributed capacitance of the line,which significantly improves the operating speed.Different types of faults are simulated by PSCAD/EMTDC to verify the effectiveness and superiority of the proposed scheme.
文摘Protection distance of surge protective devices (SPDs) is an important problem in designing a good location scheme of SPDs in low voltage distribution systems for protecting electrical equipments against over- voltage caused by lightning stroke. The simplified lumped-parameter circuit model and the circuit method were used to study the protection distance problem of SPDs. The analytical solutions of the load voltage and general equations of the protection distance of SPDs under different load conditions were given. Simulation results of examples proved the validity of the proposed analytical method.
基金supported by Science and Technology Program of State Grid Corporation of China “Research on Fault Coupling Characteristics and New Protection Principle of AC/DC Hybrid Power Grid”。
文摘Conventional transmission line distance protection approaches are subject to malfunction under reverse fault-induced current transformer(CT) saturation for the typically employed breaker-and-a-half configuration. This paper addresses this issue by proposing a new distance protection approach that combines the blocking and unblocking criteria of distance protection based on the values of incomplete differential current,operation voltage, and current harmonic content. The proposed approach is verified by theoretical analysis, dynamic simulation testing, and field operation to ensure that the obtained distance protection is reliable and refrains from operating unnecessarily under reverse fault-induced CT saturation in the breaker-and-ahalf configuration. Meanwhile, the proposed approach is demonstrated can operate reliably when forward faults occur or various reverse faults are converted to forward faults.
文摘The active saturated iron-core superconductive fault current limiter(SISFCL)is a good choice to decrease fault current.This paper introduced the principles and impedance characteristic of the active SISFCL.Then,it shows the current-limiting effects of the SISFCL.Besides,the impact of the active SISFCL on the distance protection of the EHV transmission line is evaluated.Based on that,the coordination scheme of the distance protections is proposed.A 500 kV double-circuit transmission system with SISFCLs is simulated by Electro-Magnetic Transients Program including DC(EMTDC).Simulation tests demonstrate the correctness and validity of theoretical analyses.
基金Funded by the Major State Basic Research Development Program of China(No.2005CB221503)the Key Program of the Natural Science Foundation of China(No.70533050,50904068 and 50674089)
文摘To ensure the mining safety of working face in the protective seam and meanwhile extract pressure-relief gas of the lower protected seam and eliminate its outburst risk,the present study researched into fracture development of floor coal-rock mass of the protective seam and migration rule of pressure-relief gas from a protected seam so as to obtain an effective pressure- relief gas extraction method.The results show that after the upper protective seam was mined,mining-induced fracturing floor coal-rock mas...