Implementing a control system over a communication network induces inevitable time delays that may degrade performance and even cause instability. One of the most effective ways to reduce the negative effect of delays...Implementing a control system over a communication network induces inevitable time delays that may degrade performance and even cause instability. One of the most effective ways to reduce the negative effect of delays on the performance of networked control system (NCS) is to reduce network traffic. In this paper, adjustable deadbands are explored as a solution to reduce network traffic in NCS. A method of fault-tolerant control of networked control system is presented, which takes into account system response as well as network traffic. The integrity design for a kind of NCS with sensor failures and actuator failures is analyzed based on robust fault-tolerant control theory and information scheduling. After detailed theoretical analysis, the paper also provides the simulation results, which further validate the proposed scheme.展开更多
Fieldbus, industrial Ethernet that is simple, reliable, economical, and practical, is widely used in Wind Energy Conversion Systems(WECSs). These techniques belong to the field of networked control systems. Network em...Fieldbus, industrial Ethernet that is simple, reliable, economical, and practical, is widely used in Wind Energy Conversion Systems(WECSs). These techniques belong to the field of networked control systems. Network embedding to Wind Energy Conversion Systems brings many new challenges. Implementing a control system over a communication network causes inevitable time delays that may degrade performance and can even cause instability. This work addresses challenges related to the reliable control of wind energy conversion systems, based on the theoretical framework of networked control systems. A type of WECS with network-induced delay and packet dropout is modeled and adjustable deadbands are explored as a solution to reduce network traffic in WECSs. A method to study the reliable control of WECSs is presented, which takes into account system response as well as the network environment. After detailed theoretical analysis, simulation results are provided, which further demonstrate the feasibility of the proposed scheme.展开更多
In recent years, environmental problems are becoming serious and renewable energy has attracted attention as their solutions. However, the electricity generation using the renewable energy has a demerit that the outpu...In recent years, environmental problems are becoming serious and renewable energy has attracted attention as their solutions. However, the electricity generation using the renewable energy has a demerit that the output becomes unstable because of intermittent characteristics, such as variations of wind speed or solar radiation intensity. Frequency fluctuations due to the installation of large scale wind farm (WF) and photovoltaics (PV) into the power system is a major concern. In order to solve the problem, this paper proposes two control methods using High Voltage Direct Current (HVDC) interconnection line to suppress the frequency fluctuations due to large scale of WF and PV. Comparative analysis between these two control methods is presented in this paper. One proposed method is a frequency control using a notch filter, and the other is using a deadband. Validity of the proposed methods is verified through simulation analyses, which is performed on a multi-machine power system model.展开更多
基金Supported by National Natural Science Foundation of P. R. China (60274014)the Specialized Research Fund for Doctoral Program of Higher Education of P. R. China (20020487006)
文摘Implementing a control system over a communication network induces inevitable time delays that may degrade performance and even cause instability. One of the most effective ways to reduce the negative effect of delays on the performance of networked control system (NCS) is to reduce network traffic. In this paper, adjustable deadbands are explored as a solution to reduce network traffic in NCS. A method of fault-tolerant control of networked control system is presented, which takes into account system response as well as network traffic. The integrity design for a kind of NCS with sensor failures and actuator failures is analyzed based on robust fault-tolerant control theory and information scheduling. After detailed theoretical analysis, the paper also provides the simulation results, which further validate the proposed scheme.
基金supported by National Natural Science Foundation of China Research on the Formation Mechanism and Coupled Evolution of Complex Terrain and Wind Turbine Eddy Current, No. U1865101
文摘Fieldbus, industrial Ethernet that is simple, reliable, economical, and practical, is widely used in Wind Energy Conversion Systems(WECSs). These techniques belong to the field of networked control systems. Network embedding to Wind Energy Conversion Systems brings many new challenges. Implementing a control system over a communication network causes inevitable time delays that may degrade performance and can even cause instability. This work addresses challenges related to the reliable control of wind energy conversion systems, based on the theoretical framework of networked control systems. A type of WECS with network-induced delay and packet dropout is modeled and adjustable deadbands are explored as a solution to reduce network traffic in WECSs. A method to study the reliable control of WECSs is presented, which takes into account system response as well as the network environment. After detailed theoretical analysis, simulation results are provided, which further demonstrate the feasibility of the proposed scheme.
文摘In recent years, environmental problems are becoming serious and renewable energy has attracted attention as their solutions. However, the electricity generation using the renewable energy has a demerit that the output becomes unstable because of intermittent characteristics, such as variations of wind speed or solar radiation intensity. Frequency fluctuations due to the installation of large scale wind farm (WF) and photovoltaics (PV) into the power system is a major concern. In order to solve the problem, this paper proposes two control methods using High Voltage Direct Current (HVDC) interconnection line to suppress the frequency fluctuations due to large scale of WF and PV. Comparative analysis between these two control methods is presented in this paper. One proposed method is a frequency control using a notch filter, and the other is using a deadband. Validity of the proposed methods is verified through simulation analyses, which is performed on a multi-machine power system model.