To improve the dynamic performance of conventional deadbeat predictive current control(DPCC)under parameter mismatch,especially eliminate the current overshoot and oscillation during torque mutation,it is necessary to...To improve the dynamic performance of conventional deadbeat predictive current control(DPCC)under parameter mismatch,especially eliminate the current overshoot and oscillation during torque mutation,it is necessary to enhance the robustness of DPCC against various working conditions.However,the disturbance from parameter mismatch can deteriorate the dynamic performance.To deal with the above problem,firstly,traditional DPCC and the parameter sensitivity of DPCC are introduced and analyzed.Secondly,an extended state observer(ESO)combined with DPCC method is proposed,which can observe and suppress the disturbance due to various parameter mismatch.Thirdly,to improve the accuracy and stability of ESO,an adaptive extended state observer(AESO)using fuzzy controller based on ESO,is presented,and combined with DPCC method.The improved DPCC-AESO can switch the value of gain coefficients with fuzzy control,accelerating the current response speed and avoid the overshoot and oscillation,which improves the robustness and stability performance of SPMSM.Finally,the three methods,as well as conventional DPCC method,DPCC-ESO method,DPCC-AESO method,are comparatively analyzed in this paper.The effectiveness of the proposed two methods are verified by simulation and experimental results.展开更多
The main drawbacks of traditional finite set model predictive control are high computational load,large torque ripple,and variable switching frequency.A less complex deadbeat(DB)model predictive current control(MPCC)w...The main drawbacks of traditional finite set model predictive control are high computational load,large torque ripple,and variable switching frequency.A less complex deadbeat(DB)model predictive current control(MPCC)with improved space vector pulse-width modulation(SVPWM)under a single-phase open-circuit fault is proposed.The proposed method predicts the reference voltage vector in the a-β subspace by employing the deadbeat control principle on the machine predictive model;thus,the exhaustive exploration procedure is avoided to relieve the computational load.To perform the constant switching frequency operation and achieve better steady-state performance,a modified SVPWM strategy is developed with the same conventional structure,which modulates the reference voltage vector.This new approach is based on a redesigned and adjusted post-fault virtual voltage vector space distribution that eliminates the y-axis harmonic components in the x-y subspace and ensures the generation of symmetrical PWM pulses.Meanwhile,the combined merits of the DB,MPCC,and SVPWM methods are realized.To verify the effectiveness of the proposed control scheme,comparative experiments are performed on a five-phase permanent magnet synchronous motor(PMSM)drive system.展开更多
When a short-circuit fault occurs in a phase,the faulty phase needs to be removed artificially from the system because of the loss of the capability to generate torque.In this case,both the short-circuit current and p...When a short-circuit fault occurs in a phase,the faulty phase needs to be removed artificially from the system because of the loss of the capability to generate torque.In this case,both the short-circuit current and phase-loss fault would generate additional torque ripples.In this study,a novel fault-tolerant control strategy is introduced to achieve low torque ripple operation of five-phase fault-tolerant permanent magnet synchronous motors with trapezoidal back electromotive force(FTPMSM-TEMF)in the event of a short-circuit fault.The key concept of this method is to compensate for the torque ripples caused by the short-circuit current and the adverse effect of the phase-loss.Based on the torque expression under fault conditions,the torque ripple caused by the short-circuit current can be offset by injecting a certain pulsating component into the torque expression in the phase-loss condition.This would result in smooth operation under fault conditions.Moreover,to track the fault-tolerant alternating currents,the model of the deadbeat current predictive control is extended and restructured for the fault condition.The effectiveness and feasibility of the proposed fault-tolerant strategy are verified by experimental results.展开更多
基金supported by the National Natural Science Foundation of China(No.52005037).
文摘To improve the dynamic performance of conventional deadbeat predictive current control(DPCC)under parameter mismatch,especially eliminate the current overshoot and oscillation during torque mutation,it is necessary to enhance the robustness of DPCC against various working conditions.However,the disturbance from parameter mismatch can deteriorate the dynamic performance.To deal with the above problem,firstly,traditional DPCC and the parameter sensitivity of DPCC are introduced and analyzed.Secondly,an extended state observer(ESO)combined with DPCC method is proposed,which can observe and suppress the disturbance due to various parameter mismatch.Thirdly,to improve the accuracy and stability of ESO,an adaptive extended state observer(AESO)using fuzzy controller based on ESO,is presented,and combined with DPCC method.The improved DPCC-AESO can switch the value of gain coefficients with fuzzy control,accelerating the current response speed and avoid the overshoot and oscillation,which improves the robustness and stability performance of SPMSM.Finally,the three methods,as well as conventional DPCC method,DPCC-ESO method,DPCC-AESO method,are comparatively analyzed in this paper.The effectiveness of the proposed two methods are verified by simulation and experimental results.
基金Supported in part by the National Natural Science Foundation of China under Grant 52025073in part by the Key Research and Development Program of Jiangsu Province under Grant BE2018107,and in part by the Priority Academic Program Development of Jiangsu Higher Education Institutions.
文摘The main drawbacks of traditional finite set model predictive control are high computational load,large torque ripple,and variable switching frequency.A less complex deadbeat(DB)model predictive current control(MPCC)with improved space vector pulse-width modulation(SVPWM)under a single-phase open-circuit fault is proposed.The proposed method predicts the reference voltage vector in the a-β subspace by employing the deadbeat control principle on the machine predictive model;thus,the exhaustive exploration procedure is avoided to relieve the computational load.To perform the constant switching frequency operation and achieve better steady-state performance,a modified SVPWM strategy is developed with the same conventional structure,which modulates the reference voltage vector.This new approach is based on a redesigned and adjusted post-fault virtual voltage vector space distribution that eliminates the y-axis harmonic components in the x-y subspace and ensures the generation of symmetrical PWM pulses.Meanwhile,the combined merits of the DB,MPCC,and SVPWM methods are realized.To verify the effectiveness of the proposed control scheme,comparative experiments are performed on a five-phase permanent magnet synchronous motor(PMSM)drive system.
基金the National Natural Science Foundation of China(52077097,52025073,and 51991383)in part by the Natural Science Research Project of Higher Education Institutions of Jiangsu Province(20KJA470003)in part by the Priority Academic Program Development of Jiangsu Higher Education Institutions.
文摘When a short-circuit fault occurs in a phase,the faulty phase needs to be removed artificially from the system because of the loss of the capability to generate torque.In this case,both the short-circuit current and phase-loss fault would generate additional torque ripples.In this study,a novel fault-tolerant control strategy is introduced to achieve low torque ripple operation of five-phase fault-tolerant permanent magnet synchronous motors with trapezoidal back electromotive force(FTPMSM-TEMF)in the event of a short-circuit fault.The key concept of this method is to compensate for the torque ripples caused by the short-circuit current and the adverse effect of the phase-loss.Based on the torque expression under fault conditions,the torque ripple caused by the short-circuit current can be offset by injecting a certain pulsating component into the torque expression in the phase-loss condition.This would result in smooth operation under fault conditions.Moreover,to track the fault-tolerant alternating currents,the model of the deadbeat current predictive control is extended and restructured for the fault condition.The effectiveness and feasibility of the proposed fault-tolerant strategy are verified by experimental results.