期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Combined Optimal Dispatch of Thermal Power Generators and Energy Storage Considering Thermal Power Deep Peak Clipping and Wind Energy Emission Grading Punishment
1
作者 Junhui Li Xuanzhong Luo +2 位作者 Changxing Ge Cuiping Li Changrong Wang 《Energy Engineering》 EI 2024年第4期869-893,共25页
Peak load and wind energy emission pressure rise more as wind energy penetration keeps growing,which affects the stabilization of the PS(power system).This paper suggests integrated optimal dispatching of thermal powe... Peak load and wind energy emission pressure rise more as wind energy penetration keeps growing,which affects the stabilization of the PS(power system).This paper suggests integrated optimal dispatching of thermal power generators and BESS(battery energy storage system)taking wind energy emission grading punishment and deep peak clipping into consideration.Firstly,in order to minimize wind abandonment,a hierarchical wind abandonment penalty strategy based on fuzzy control is designed and introduced,and the optimal grid-connected power of wind energy is determined as a result of minimizing the peak cutting cost of the system.Secondly,considering BESS and thermal power,the management approach of BESS-assisted virtual peak clipping of thermal power generators is aimed at reducing the degree of deep peak clipping of thermal power generators and optimizing the output of thermal power generators and the charging and discharging power of BESS.Finally,Give an example of how this strategy has been effective in reducing abandonment rates by 0.66% and 7.46% individually for different wind penetration programs,and the daily average can reduce the peak clipping power output of thermal power generators by 42.97 and 72.31 MWh and enhances the effect and economy of system peak clipping. 展开更多
关键词 BESS wind energy deep peak clipping virtual peak clipping wind energy emission grading punishment
下载PDF
Role of optimal transmission switching in accommodating renewable energy in deep peak regulation-enabled power systems 被引量:5
2
作者 Qi An Jianxiao Wang +1 位作者 Gengyin Li Ming Zhou 《Global Energy Interconnection》 CAS 2020年第6期577-584,共8页
Due to the shortage of fossil energy and the pollution caused by combustion of fossil fuels,the proportion of renewable energy in power systems is gradually increasing across the world.Accordingly,the capacity of powe... Due to the shortage of fossil energy and the pollution caused by combustion of fossil fuels,the proportion of renewable energy in power systems is gradually increasing across the world.Accordingly,the capacity of power systems to accommodate renewable energy must be improved.However,integration of a large amount of renewable energy into power grids may result in network congestion.Hence,in this study,optimal transmission switching(OTS)is considered as an important method of accommodating renewable energy.It is incorporated into the operation of a power grid along with deep peak regulation of thermal power units,forming an interactive mode of coordinated operation of source and network.A stochastic unit commitment model consider!ng deep peak regulation and OTS is established,and the role of OTS in promoting the accommodation of renewable energy is analyzed quantitatively.The results of case studies involving the IEEE 30-bus system demonstrate that OTS can enable utilization of the potential of deep peak regulation and facilitate the accommodation of renewable energy. 展开更多
关键词 deep peak regulation Renewable energy Security-constrained unit commitment Transmission switching
下载PDF
Flexible Operation Mode of Coal-fired Power Unit Coupling with Heat Storage of Extracted Reheat Steam 被引量:3
3
作者 WEI Haijiao LU Yuanwei +4 位作者 YANG Yanchun ZHANG Cancan WU Yuting LI Weidong ZHAO Dongming 《Journal of Thermal Science》 SCIE EI CAS CSCD 2022年第2期436-447,共12页
In order to provide more grid space for the renewable energy power,the traditional coal-fired power unit should be operated flexibility,especially achieved the deep peak shaving capacity.In this paper,a new scheme usi... In order to provide more grid space for the renewable energy power,the traditional coal-fired power unit should be operated flexibility,especially achieved the deep peak shaving capacity.In this paper,a new scheme using the reheat steam extraction is proposed to further reduce the load far below 50%rated power.Two flexible operation modes of increasing power output mode and reducing fuel mode are proposed in heat discharging process.A 600 MW coal-fired power unit with 50%rated power is chosen as the research model.The results show that the power output is decreased from 300.03 MW to 210.07 MW when the extracted reheat steam flow rate is 270.70 t·h^(-1),which increases the deep peak shaving capacity by 15%rated power.The deep peak shaving time and the thermal efficiency are 7.63 h·d^(-1)and 36.91%respectively for the increasing power output mode,and they are 7.24 h·d^(-1)and 36.58%respectively for the reducing fuel mode.The increasing power output mode has the advantages of higher deep peak shaving time and the thermal efficiency,which is recommended as the preferred scheme for the flexible operation of the coal-fired power unit. 展开更多
关键词 coal-fired power unit flexible operation deep peak shaving extracted reheat steam heat storage
原文传递
Day-ahead Optimal Dispatch Model for Coupled System Considering Ladder-type Ramping Rate and Flexible Spinning Reserve of Thermal Power Units 被引量:1
4
作者 Longjie Yang Niancheng Zhou +5 位作者 Guiping Zhou Yuan Chi Ning Chen Lei Wang Qianggang Wang Dongfeng Chang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第6期1482-1493,共12页
In northern China,thermal power units(TPUs)are important in improving the penetration level of renewable energy.In such areas,the potentials of coordinated dispatch of renewable energy sources(RESs)and TPUs can be bet... In northern China,thermal power units(TPUs)are important in improving the penetration level of renewable energy.In such areas,the potentials of coordinated dispatch of renewable energy sources(RESs)and TPUs can be better realized,if RESs and TPUs connected to the power grid at the same point of common coupling(PCC)are dispatched as a coupled system.Firstly,the definition of the coupled system is introduced,followed by an analysis on its characteristics.Secondly,based on the operation characteristics of deep peak regulation(DPR)of TPUs in the coupled system,the constraint of the ladder-type ramping rate applicable for day-ahead dispatch is proposed,and the corresponding flexible spinning reserve constraint is further established.Then,considering these constraints and peak regulation ancillary services,a day-ahead optimal dispatch model of the coupled system is established.Finally,the operational characteristics and advantages of the coupled system are analyzed in several case studies based on a real-world power grid in Liaoning province,China.The numerical results show that the coupled system can further improve the economic benefits of RESs and TPUs under the existing policies. 展开更多
关键词 Coupled system ladder-type ramping rate flexible spinning reserve day-ahead optimal dispatch deep peak regulation peak regulation ancillary services
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部