Objective The aim of the study was to evaluate catheter-related infection rate(CRIR)for patients receiving minimally invasive esophagectomy(MIE),to identify the optimal catheterization approach and relationship betwee...Objective The aim of the study was to evaluate catheter-related infection rate(CRIR)for patients receiving minimally invasive esophagectomy(MIE),to identify the optimal catheterization approach and relationship between CRIR and post-operative complications.Methods In total,168 patients with esophageal carcinoma and undergoing MIE combined with preoperative deep venous catheterization(DVC)were analyzed in our institution(Qingdao Municipal Hospital,China),from 2014 to 2018.After completing DVC,catheter-tips together with intraductal venous blood samples were sent to the microbiology lab for bacterial strain culture.CRIR was statistically evaluated for the following clinical variables:gender,age,smoking status,drinking status,past history,tumor location,histologic grade,pathological T,N,and M category,anastomotic location,anastomotic leakage,anastomotic stricture,chylothorax,pneumonia,recurrent laryngeal nerve(RLN)injury,reflux esophagitis,catheterization site,and catheter-locking days.Results Among the 144 patients recruited in our study,105 catheters were inserted into the jugular vein and 39 catheters into the subclavian vein.The median age of these patients was 63 years(range:42–79 years),and the median catheter-locking period was seven days(range:4–21 days).Four catheters were identified with three types of strain colonizations,including Staphylococcus epidermidis,Staphylococcus aureus and Blastomyces albicans.Statistical data showed that patients diagnosed with catheter-related infection were likely to incur anastomotic leakage(66.67%,P<0.001)and pneumonia(27.27%,P<0.001);features such as tumors located in the upper esophagus(13.6%,P=0.003),and over seven catheterlocking days(10.00%,P<0.001)were attributed to a high CRIR.Conclusion Although both jugular and subclavian veins can be catheterized for patients with MIE,DVC is associated with more than seven catheter-locking days and upper esophagectomy,due to high CRIR.Furthermore,catheter-related infection is related to anastomotic leakage and pneumonia.展开更多
Objective:To systematically evaluate the clinical effects of cluster nursing intervention in preventing central venous catheter-related infection in intensive care unit.Methods:A randomized controlled study was search...Objective:To systematically evaluate the clinical effects of cluster nursing intervention in preventing central venous catheter-related infection in intensive care unit.Methods:A randomized controlled study was searched from China National Knowledge Internet(CNKI),Wanfang,Chinese Scientific Journals Database(VIP),Chinese Biomedical Literature Service System(SinoMed),PubMed,Embase and Cochrane library databases from the establishment to May 1,2020.Two reviewers independently evaluated and cross checked the quality of the study.Revman 5.3 was used to conduct the meta-analysis.Results:A total of 21 randomized controlled trials with 6,030 patients were included.Meta-analysis showed that the incidence of central venous catheter-related infection(relative risk(RR)=0.29,95%confidence interval(CI)[0.23,0.37]),the incidence of catheter plugging(RR=0.25,95%CI[0.16,0.39])and catheter prolapse(RR=0.18,95%CI[0.11,0.29])were significantly different between the two groups.Conclusion:Cluster nursing intervention could prevent central venous catheter-related infection in intensive care unit.展开更多
BACKGROUND Central venous catheters(CVCs)often cause life-threatening complications,especially CVC-related bloodstream infection(CVC-BSI)and catheter-related thrombosis(CRT).Here,we report an unusual case of misplaced...BACKGROUND Central venous catheters(CVCs)often cause life-threatening complications,especially CVC-related bloodstream infection(CVC-BSI)and catheter-related thrombosis(CRT).Here,we report an unusual case of misplaced CVC-induced emphysematous thrombophlebitis,a rare but potentially lethal form of CRT and CVC-BSI characterized by both thrombosis and gas formation.CASE SUMMARY A 48-year-old male presented to the emergency room of a local hospital with sudden-onset headache and coma for 4 h.Computed tomography(CT)revealed right basal ganglia hemorrhage,so emergency decompressive craniotomy was performed and a CVC was inserted through the right subclavian vein for fluid resuscitation during anesthesia.Two days later,the patient was transferred to the intensive care unit of our hospital for further critical care.On day 9 after CVC insertion,the patient suddenly developed fever and hypotension.Point-of-care ultrasound(POCUS)demonstrated thrombosis and dilatation of the right internal jugular vein(IJV)filled with thrombosis.Ultrasonography also revealed that the CVC tip had been misplaced into the IJV and was surrounded by gas bubbles,which manifested as hyperechoic lines with dirty shadowing and comet-tail artifacts.Further CT scan confirmed air bubbles surrounding the CVC in the right neck.The final diagnosis was septic emphysematous thrombophlebitis induced by a misplaced CVC and ensuing septic shock.The responsible CVC was removed immediately.The patient received fluid resuscitation,intravenous noradrenaline,and a 10-d ultra-broad spectrum antibiotic treatment to combat septic shock.Both CVC and peripheral venous blood cultures yielded methicillin-resistant Staphylococcus cohnii.The patient was gradually weaned off vasopressors and the symptoms of redness and swelling in the right neck subsided within 7 d.CONCLUSION Emphysematous thrombophlebitis is a fulminant and life-threatening CVC-BSI associated with thrombosis and gas formation in the vein.A misplaced CVC may facilitate the development of emphysematous thrombophlebitis.POCUS can easily identify the artifacts produced by gas and thrombosis,facilitating rapid diagnosis at the bedside.展开更多
As the number of patients receiving total joint replacements continues to rise,considerable attention has been directed towards the early detection and prevention of postoperative complications.While D-dimer has long ...As the number of patients receiving total joint replacements continues to rise,considerable attention has been directed towards the early detection and prevention of postoperative complications.While D-dimer has long been studied as a diagnostic tool in venous thromboembolism(VTE),this assay has recently received considerable attention in the diagnosis of periprosthetic joint infection(PJI).D-dimer values are substantially elevated in the acute postoperative period after total joint arthroplasty,with levels often exceeding the standard institutional cutoff for VTE(500µg/L).The utility of D-dimer in detecting VTE after total joint replacement is currently limited,and more research to assess its value in the setting of contemporary prophylaxis protocols is warranted.Recent literature supports D-dimer as a good to excellent biomarker for the diagnosis of chronic PJI,especially when using serum sample technique.Providers should exercise caution when interpreting D-dimer levels in patients with inflammatory and hypercoagulability disorders,as the diagnostic value is decreased.The updated 2018 Musculoskeletal Infection Society criteria,which includes D-dimer levels>860µg/L as a minor criterion,may be the most accurate for diagnosing chronic PJI to date.Larger prospective trials with transparent lab testing protocols are needed to establish best assay practices and optimal cutoff values for D-dimer in the diagnosis of PJI.This review summarizes the most current literature on the value of D-dimer in total joint arthroplasty and elucidates areas for future progress.展开更多
文摘Objective The aim of the study was to evaluate catheter-related infection rate(CRIR)for patients receiving minimally invasive esophagectomy(MIE),to identify the optimal catheterization approach and relationship between CRIR and post-operative complications.Methods In total,168 patients with esophageal carcinoma and undergoing MIE combined with preoperative deep venous catheterization(DVC)were analyzed in our institution(Qingdao Municipal Hospital,China),from 2014 to 2018.After completing DVC,catheter-tips together with intraductal venous blood samples were sent to the microbiology lab for bacterial strain culture.CRIR was statistically evaluated for the following clinical variables:gender,age,smoking status,drinking status,past history,tumor location,histologic grade,pathological T,N,and M category,anastomotic location,anastomotic leakage,anastomotic stricture,chylothorax,pneumonia,recurrent laryngeal nerve(RLN)injury,reflux esophagitis,catheterization site,and catheter-locking days.Results Among the 144 patients recruited in our study,105 catheters were inserted into the jugular vein and 39 catheters into the subclavian vein.The median age of these patients was 63 years(range:42–79 years),and the median catheter-locking period was seven days(range:4–21 days).Four catheters were identified with three types of strain colonizations,including Staphylococcus epidermidis,Staphylococcus aureus and Blastomyces albicans.Statistical data showed that patients diagnosed with catheter-related infection were likely to incur anastomotic leakage(66.67%,P<0.001)and pneumonia(27.27%,P<0.001);features such as tumors located in the upper esophagus(13.6%,P=0.003),and over seven catheterlocking days(10.00%,P<0.001)were attributed to a high CRIR.Conclusion Although both jugular and subclavian veins can be catheterized for patients with MIE,DVC is associated with more than seven catheter-locking days and upper esophagectomy,due to high CRIR.Furthermore,catheter-related infection is related to anastomotic leakage and pneumonia.
文摘Objective:To systematically evaluate the clinical effects of cluster nursing intervention in preventing central venous catheter-related infection in intensive care unit.Methods:A randomized controlled study was searched from China National Knowledge Internet(CNKI),Wanfang,Chinese Scientific Journals Database(VIP),Chinese Biomedical Literature Service System(SinoMed),PubMed,Embase and Cochrane library databases from the establishment to May 1,2020.Two reviewers independently evaluated and cross checked the quality of the study.Revman 5.3 was used to conduct the meta-analysis.Results:A total of 21 randomized controlled trials with 6,030 patients were included.Meta-analysis showed that the incidence of central venous catheter-related infection(relative risk(RR)=0.29,95%confidence interval(CI)[0.23,0.37]),the incidence of catheter plugging(RR=0.25,95%CI[0.16,0.39])and catheter prolapse(RR=0.18,95%CI[0.11,0.29])were significantly different between the two groups.Conclusion:Cluster nursing intervention could prevent central venous catheter-related infection in intensive care unit.
基金Supported by Foundation of Guizhou Science and Technology Department,No.QIANKEHEZHICHEN[2022]YIBAN179Foundation of Kweichow Moutai Hospital,No.MTyk2022-12+1 种基金Foundation of Department of Health of Guizhou Province,No.gzwkj2021-036Guizhou Education Department,No.QIANJIAOHEKYZI[2018]239.
文摘BACKGROUND Central venous catheters(CVCs)often cause life-threatening complications,especially CVC-related bloodstream infection(CVC-BSI)and catheter-related thrombosis(CRT).Here,we report an unusual case of misplaced CVC-induced emphysematous thrombophlebitis,a rare but potentially lethal form of CRT and CVC-BSI characterized by both thrombosis and gas formation.CASE SUMMARY A 48-year-old male presented to the emergency room of a local hospital with sudden-onset headache and coma for 4 h.Computed tomography(CT)revealed right basal ganglia hemorrhage,so emergency decompressive craniotomy was performed and a CVC was inserted through the right subclavian vein for fluid resuscitation during anesthesia.Two days later,the patient was transferred to the intensive care unit of our hospital for further critical care.On day 9 after CVC insertion,the patient suddenly developed fever and hypotension.Point-of-care ultrasound(POCUS)demonstrated thrombosis and dilatation of the right internal jugular vein(IJV)filled with thrombosis.Ultrasonography also revealed that the CVC tip had been misplaced into the IJV and was surrounded by gas bubbles,which manifested as hyperechoic lines with dirty shadowing and comet-tail artifacts.Further CT scan confirmed air bubbles surrounding the CVC in the right neck.The final diagnosis was septic emphysematous thrombophlebitis induced by a misplaced CVC and ensuing septic shock.The responsible CVC was removed immediately.The patient received fluid resuscitation,intravenous noradrenaline,and a 10-d ultra-broad spectrum antibiotic treatment to combat septic shock.Both CVC and peripheral venous blood cultures yielded methicillin-resistant Staphylococcus cohnii.The patient was gradually weaned off vasopressors and the symptoms of redness and swelling in the right neck subsided within 7 d.CONCLUSION Emphysematous thrombophlebitis is a fulminant and life-threatening CVC-BSI associated with thrombosis and gas formation in the vein.A misplaced CVC may facilitate the development of emphysematous thrombophlebitis.POCUS can easily identify the artifacts produced by gas and thrombosis,facilitating rapid diagnosis at the bedside.
文摘As the number of patients receiving total joint replacements continues to rise,considerable attention has been directed towards the early detection and prevention of postoperative complications.While D-dimer has long been studied as a diagnostic tool in venous thromboembolism(VTE),this assay has recently received considerable attention in the diagnosis of periprosthetic joint infection(PJI).D-dimer values are substantially elevated in the acute postoperative period after total joint arthroplasty,with levels often exceeding the standard institutional cutoff for VTE(500µg/L).The utility of D-dimer in detecting VTE after total joint replacement is currently limited,and more research to assess its value in the setting of contemporary prophylaxis protocols is warranted.Recent literature supports D-dimer as a good to excellent biomarker for the diagnosis of chronic PJI,especially when using serum sample technique.Providers should exercise caution when interpreting D-dimer levels in patients with inflammatory and hypercoagulability disorders,as the diagnostic value is decreased.The updated 2018 Musculoskeletal Infection Society criteria,which includes D-dimer levels>860µg/L as a minor criterion,may be the most accurate for diagnosing chronic PJI to date.Larger prospective trials with transparent lab testing protocols are needed to establish best assay practices and optimal cutoff values for D-dimer in the diagnosis of PJI.This review summarizes the most current literature on the value of D-dimer in total joint arthroplasty and elucidates areas for future progress.