In this study, a three-dimensional (3D) in-situ laser machining system integrating laser measurement and machining was built using a 3D galvanometer scanner equipped with a side-axis industrial camera. A line structur...In this study, a three-dimensional (3D) in-situ laser machining system integrating laser measurement and machining was built using a 3D galvanometer scanner equipped with a side-axis industrial camera. A line structured light measurement model based on a galvanometer scanner was proposed to obtain the 3D information of the workpiece. A height calibration method was proposed to further ensure measurement accuracy, so as to achieve accurate laser focusing. In-situ machining software was developed to realize time-saving and labor-saving 3D laser processing. The feasibility and practicability of this in-situ laser machining system were verified using specific cases. In comparison with the conventional line structured light measurement method, the proposed methods do not require light plane calibration, and do not need additional motion axes for 3D reconstruction;thus they provide technical and cost advantages. The insitu laser machining system realizes a simple operation process by integrating measurement and machining,which greatly reduces labor and time costs.展开更多
Dental stem cells can differentiate into different types of cells.Dental pulp stem cells,stem cells from human exfoliated deciduous teeth,periodontal ligament stem cells,stem cells from apical papilla,and dental folli...Dental stem cells can differentiate into different types of cells.Dental pulp stem cells,stem cells from human exfoliated deciduous teeth,periodontal ligament stem cells,stem cells from apical papilla,and dental follicle progenitor cells are five different types of dental stem cells that have been identified during different stages of tooth development.The availability of dental stem cells from discarded or removed teeth makes them promising candidates for tissue engineering.In recent years,three-dimensional(3D)tissue scaffolds have been used to reconstruct and restore different anatomical defects.With rapid advances in 3D tissue engineering,dental stem cells have been used in the regeneration of 3D engineered tissue.This review presents an overview of different types of dental stem cells used in 3D tissue regeneration,which are currently the most common type of stem cells used to treat human tissue conditions.展开更多
Antibacterial adhesives are promising to inhibit biofilms and secondary caries. The objectives of this study were to synthesize and incorporate quaternary ammonium methacrylates into adhesives, and investigate the alk...Antibacterial adhesives are promising to inhibit biofilms and secondary caries. The objectives of this study were to synthesize and incorporate quaternary ammonium methacrylates into adhesives, and investigate the alkyl chain length effects on three-dimensional biofilms adherent on adhesives for the first time. Six quaternary ammonium methacrylates with chain lengths of 3, 6, 9, 12, 16 and 18 were synthesized and incorporated into Scotchbond Multi-Purpose. Streptococcus mutans bacteria were cultured on resin to form biofilms. Confocal laser scanning microscopy was used to measure biofilm thickness, live/dead volumes and live-bacteria percentage vs. distance from resin surface. Biofilm thickness was the greatest for Scotchbond control; it decreased with increasing chain length, reaching a minimum at chain length 16. Live-biofilm volume had a similar trend. Dead-biofilm volume increased with increasing chain length. The adhesive with chain length 9 had 37% live bacteria near resin surface, but close to 100% live bacteria in the biofilm top section. For chain length 16, there were nearly 0% live bacteria throughout the three-dimensional biofilm. In conclusion, strong antibacterial activity was achieved by adding quaternary ammonium into adhesive, with biofilm thickness and live-biofilm volume decreasing as chain length was increased from 3 to 16. Antibacterial adhesives typically only inhibited bacteria close to its surface; however, adhesive with chain length 16 had mostly dead bacteria in the entire three-dimensional biofilm. Antibacterial adhesive with chain length 16 is promising to inhibit biofilms at the margins and combat secondary caries.展开更多
In order to meet the requirements of nondestructive testing of true 3D topography of micro-nano structures,a novel three-dimensional atomic force microscope(3D-AFM)based on flared tip is developed.A high-precision sca...In order to meet the requirements of nondestructive testing of true 3D topography of micro-nano structures,a novel three-dimensional atomic force microscope(3D-AFM)based on flared tip is developed.A high-precision scanning platform is designed to achieve fast servo through moving probe and sample simultaneously,and several combined nanopositioning stages are used to guarantee linearity and orthogonality of displacement.To eliminate the signal deviation caused by AFM-head movement,a traceable optical lever system is designed for cantilever deformation detection.In addition,a method of tailoring the cantilever of commercial probe with flared tip is proposed to reduce the lateral force applied on the tip in measurement.The tailored probe is mounted on the 3D-AFM,and 3D imaging experiments are conducted on different samples by use of adaptive-angle scanning strategy.The results show the roob-mean-square value of the vertical displacement noise(RMS)of the prototype is less than 0.1 nm and the high/width measurement repeatability(peak-to-peak)is less than 2.5 nm.展开更多
Recently,the diagnoses of dental caries and other dental issues are in a queue as only X-ray-based techniques are available in most hospitals around the world.Terahertz(THz)parametric imaging(TPI)is the latest technol...Recently,the diagnoses of dental caries and other dental issues are in a queue as only X-ray-based techniques are available in most hospitals around the world.Terahertz(THz)parametric imaging(TPI)is the latest technology that can be applied for medical applications,especially dental caries.This technology is harmless and thus suitable for biological samples owing to the low energy of THz emission.In this paper,a developed TPI system is used to investigate the two-dimensional(2 D)and three-dimensional(3D)images of different samples from human teeth.After analyzing the measured images of human teeth,the results suggest that the THz parametric technology is capable of investigating the inner side structure of the teeth.This technique can be useful in detecting the defects in all types of human and animal teeth.The measurement and analytical calculations have been performed by using the TPI system and MATLAB,respectively,and both are in good agreement.The characteristics of THz waves and their interactions with the tooth samples are summarized.And the available THz-based technologies,such as TPI,and their potential applications of diagnoses are also presented.展开更多
The Dunhuang–Golmud railway passes through different deserts in arid areas,especially drifting-sand desert and sandy-gravel Gobi.The near-surface wind environment and wind-sand transport process vary due to different...The Dunhuang–Golmud railway passes through different deserts in arid areas,especially drifting-sand desert and sandy-gravel Gobi.The near-surface wind environment and wind-sand transport process vary due to different external factors,such as topography,vegetation,and regional climate,resulting in evident spatial differences in surface erosion and deposition.Consequently,the measures for preventing wind-sand hazards will differ.However,the mechanism and control theory of sand damage remain poorly understood.In this study,we used meteorological observation,three-dimensional(3D)laser scanning,and grain-size analysis to compare and evaluate the spatial distribution of wind conditions,sand erosion and deposition patterns,and grain composition in the drifting-sand desert and sandy-gravel Gobi along the Dunhuang–Golmud railway in China.Results show that the annual mean wind speed,the frequency of sand-driving wind,and the drift potential of sandy-gravel Gobi are higher than those of drifting-sand desert,indicating a greater wind strength in the sandy-gravel Gobi,which exhibits spatial heterogeneity in wind conditions.The major sediment components in sandy-gravel Gobi are very fine sand,fine sand,and medium sand,and that in drifting-sand desert are very fine sand and fine sand.We found that the sediment in the sandy-gravel Gobi is coarser than that in the drifting-sand desert based on mean grain size and sediment component.The spatial distributions of sand erosion and deposition in the sandy-gravel Gobi and drifting-sand desert are consistent,with sand deposition mainly on the west side of the railway and sand erosion on the east side of the railway.The area of sand deposition in the drifting-sand desert accounts for 75.83%of the total area,with a mean deposition thickness of 0.032 m;while the area of sand deposition in the sandy-gravel Gobi accounts for 65.31%of the total area,with a mean deposition thickness of 0.028 m,indicating greater deposition amounts in the drifting-sand desert due to the presence of more fine sediment components.However,the sand deposition is more concentrated with a greater thickness on the embankment and track in the sandy-gravel Gobi and is dispersed with a uniform thickness in the drifting-sand desert.The sand deposition on the track of the sandy-gravel Gobi mainly comes from the east side of the railway.The results of this study are helpful in developing the preventive measures and determining appropriate selection and layout measures for sand control.展开更多
目的对比研究数字化咬合导板的设计和制作方法,提高数字化咬合导板的颌骨定位精度。方法通过扫描口内天然牙列与体外石膏模型两种方法获取两组数字化牙模型,将数字化牙[牙合]模型导入Mimics Medical 20.0软件,进行咬合导板设计及3D打印...目的对比研究数字化咬合导板的设计和制作方法,提高数字化咬合导板的颌骨定位精度。方法通过扫描口内天然牙列与体外石膏模型两种方法获取两组数字化牙模型,将数字化牙[牙合]模型导入Mimics Medical 20.0软件,进行咬合导板设计及3D打印制作,术中导航记录两组咬合导板定位颌骨的标记点坐标,计算7个颌骨测量点与设计方案数据间的距离偏差(DE)。应用咬合导板的适应性、偏差分析中的指标均方根值(RMS)、术中导航数据综合评价两组咬合导板的精度。结果两组咬合导板口内适应性比较差异具有统计学意义(χ^2=22.308,P<0.01)。两组咬合导板RMS比较差异有统计学意义(t=2.086,P<0.05)。两组咬合导板在上下颌导航X轴上A点和Y轴上A、FPR、FPL、RPR、RPL点与设计方案数据间的DE比较差异具有统计学意义(Z=-2.871^-2.020,P<0.05)。结论口扫咬合导板的定位精度优于模扫咬合导板。展开更多
文摘In this study, a three-dimensional (3D) in-situ laser machining system integrating laser measurement and machining was built using a 3D galvanometer scanner equipped with a side-axis industrial camera. A line structured light measurement model based on a galvanometer scanner was proposed to obtain the 3D information of the workpiece. A height calibration method was proposed to further ensure measurement accuracy, so as to achieve accurate laser focusing. In-situ machining software was developed to realize time-saving and labor-saving 3D laser processing. The feasibility and practicability of this in-situ laser machining system were verified using specific cases. In comparison with the conventional line structured light measurement method, the proposed methods do not require light plane calibration, and do not need additional motion axes for 3D reconstruction;thus they provide technical and cost advantages. The insitu laser machining system realizes a simple operation process by integrating measurement and machining,which greatly reduces labor and time costs.
基金Supported by Chang Gung Memorial Hospital,Linkou,Taiwan,No.CORPG3K0021 and No.CORPG3K0191.
文摘Dental stem cells can differentiate into different types of cells.Dental pulp stem cells,stem cells from human exfoliated deciduous teeth,periodontal ligament stem cells,stem cells from apical papilla,and dental follicle progenitor cells are five different types of dental stem cells that have been identified during different stages of tooth development.The availability of dental stem cells from discarded or removed teeth makes them promising candidates for tissue engineering.In recent years,three-dimensional(3D)tissue scaffolds have been used to reconstruct and restore different anatomical defects.With rapid advances in 3D tissue engineering,dental stem cells have been used in the regeneration of 3D engineered tissue.This review presents an overview of different types of dental stem cells used in 3D tissue regeneration,which are currently the most common type of stem cells used to treat human tissue conditions.
基金supported by NIH R01 DE17974West China School of Stomatologya Seed Grant from Department of Endodontics,Prosthodontics and Operative Dentistry,University of Maryland
文摘Antibacterial adhesives are promising to inhibit biofilms and secondary caries. The objectives of this study were to synthesize and incorporate quaternary ammonium methacrylates into adhesives, and investigate the alkyl chain length effects on three-dimensional biofilms adherent on adhesives for the first time. Six quaternary ammonium methacrylates with chain lengths of 3, 6, 9, 12, 16 and 18 were synthesized and incorporated into Scotchbond Multi-Purpose. Streptococcus mutans bacteria were cultured on resin to form biofilms. Confocal laser scanning microscopy was used to measure biofilm thickness, live/dead volumes and live-bacteria percentage vs. distance from resin surface. Biofilm thickness was the greatest for Scotchbond control; it decreased with increasing chain length, reaching a minimum at chain length 16. Live-biofilm volume had a similar trend. Dead-biofilm volume increased with increasing chain length. The adhesive with chain length 9 had 37% live bacteria near resin surface, but close to 100% live bacteria in the biofilm top section. For chain length 16, there were nearly 0% live bacteria throughout the three-dimensional biofilm. In conclusion, strong antibacterial activity was achieved by adding quaternary ammonium into adhesive, with biofilm thickness and live-biofilm volume decreasing as chain length was increased from 3 to 16. Antibacterial adhesives typically only inhibited bacteria close to its surface; however, adhesive with chain length 16 had mostly dead bacteria in the entire three-dimensional biofilm. Antibacterial adhesive with chain length 16 is promising to inhibit biofilms at the margins and combat secondary caries.
基金National Key Research and Development Pragram of China(No.2016YFF0200602)National Natural Science Foundation of China(No.61973233)。
文摘In order to meet the requirements of nondestructive testing of true 3D topography of micro-nano structures,a novel three-dimensional atomic force microscope(3D-AFM)based on flared tip is developed.A high-precision scanning platform is designed to achieve fast servo through moving probe and sample simultaneously,and several combined nanopositioning stages are used to guarantee linearity and orthogonality of displacement.To eliminate the signal deviation caused by AFM-head movement,a traceable optical lever system is designed for cantilever deformation detection.In addition,a method of tailoring the cantilever of commercial probe with flared tip is proposed to reduce the lateral force applied on the tip in measurement.The tailored probe is mounted on the 3D-AFM,and 3D imaging experiments are conducted on different samples by use of adaptive-angle scanning strategy.The results show the roob-mean-square value of the vertical displacement noise(RMS)of the prototype is less than 0.1 nm and the high/width measurement repeatability(peak-to-peak)is less than 2.5 nm.
基金the Research Fund for International Young Scientist Fund under Grant No.61750110520the Special Project for Guiding Local Science and Technology Development under Grant No.2018ZYYD006the Hubei Polytechnic University Laboratory Fund under Grant No.19XJK24R。
文摘Recently,the diagnoses of dental caries and other dental issues are in a queue as only X-ray-based techniques are available in most hospitals around the world.Terahertz(THz)parametric imaging(TPI)is the latest technology that can be applied for medical applications,especially dental caries.This technology is harmless and thus suitable for biological samples owing to the low energy of THz emission.In this paper,a developed TPI system is used to investigate the two-dimensional(2 D)and three-dimensional(3D)images of different samples from human teeth.After analyzing the measured images of human teeth,the results suggest that the THz parametric technology is capable of investigating the inner side structure of the teeth.This technique can be useful in detecting the defects in all types of human and animal teeth.The measurement and analytical calculations have been performed by using the TPI system and MATLAB,respectively,and both are in good agreement.The characteristics of THz waves and their interactions with the tooth samples are summarized.And the available THz-based technologies,such as TPI,and their potential applications of diagnoses are also presented.
基金This research was supported by the National Natural Science Foundation of China(42171083,41871016)the Natural Science Foundation of Gansu Province,China(22JR5RA066).
文摘The Dunhuang–Golmud railway passes through different deserts in arid areas,especially drifting-sand desert and sandy-gravel Gobi.The near-surface wind environment and wind-sand transport process vary due to different external factors,such as topography,vegetation,and regional climate,resulting in evident spatial differences in surface erosion and deposition.Consequently,the measures for preventing wind-sand hazards will differ.However,the mechanism and control theory of sand damage remain poorly understood.In this study,we used meteorological observation,three-dimensional(3D)laser scanning,and grain-size analysis to compare and evaluate the spatial distribution of wind conditions,sand erosion and deposition patterns,and grain composition in the drifting-sand desert and sandy-gravel Gobi along the Dunhuang–Golmud railway in China.Results show that the annual mean wind speed,the frequency of sand-driving wind,and the drift potential of sandy-gravel Gobi are higher than those of drifting-sand desert,indicating a greater wind strength in the sandy-gravel Gobi,which exhibits spatial heterogeneity in wind conditions.The major sediment components in sandy-gravel Gobi are very fine sand,fine sand,and medium sand,and that in drifting-sand desert are very fine sand and fine sand.We found that the sediment in the sandy-gravel Gobi is coarser than that in the drifting-sand desert based on mean grain size and sediment component.The spatial distributions of sand erosion and deposition in the sandy-gravel Gobi and drifting-sand desert are consistent,with sand deposition mainly on the west side of the railway and sand erosion on the east side of the railway.The area of sand deposition in the drifting-sand desert accounts for 75.83%of the total area,with a mean deposition thickness of 0.032 m;while the area of sand deposition in the sandy-gravel Gobi accounts for 65.31%of the total area,with a mean deposition thickness of 0.028 m,indicating greater deposition amounts in the drifting-sand desert due to the presence of more fine sediment components.However,the sand deposition is more concentrated with a greater thickness on the embankment and track in the sandy-gravel Gobi and is dispersed with a uniform thickness in the drifting-sand desert.The sand deposition on the track of the sandy-gravel Gobi mainly comes from the east side of the railway.The results of this study are helpful in developing the preventive measures and determining appropriate selection and layout measures for sand control.
文摘目的对比研究数字化咬合导板的设计和制作方法,提高数字化咬合导板的颌骨定位精度。方法通过扫描口内天然牙列与体外石膏模型两种方法获取两组数字化牙模型,将数字化牙[牙合]模型导入Mimics Medical 20.0软件,进行咬合导板设计及3D打印制作,术中导航记录两组咬合导板定位颌骨的标记点坐标,计算7个颌骨测量点与设计方案数据间的距离偏差(DE)。应用咬合导板的适应性、偏差分析中的指标均方根值(RMS)、术中导航数据综合评价两组咬合导板的精度。结果两组咬合导板口内适应性比较差异具有统计学意义(χ^2=22.308,P<0.01)。两组咬合导板RMS比较差异有统计学意义(t=2.086,P<0.05)。两组咬合导板在上下颌导航X轴上A点和Y轴上A、FPR、FPL、RPR、RPL点与设计方案数据间的DE比较差异具有统计学意义(Z=-2.871^-2.020,P<0.05)。结论口扫咬合导板的定位精度优于模扫咬合导板。