期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
High temperature thermoelectric properties of highly c-axis oriented Bi_2Sr_2Co_2O_y thin films fabricated by pulsed laser deposition 被引量:2
1
作者 陈珊珊 王淑芳 +5 位作者 刘富强 闫国英 陈景春 王江龙 于威 傅广生 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第8期465-468,共4页
High-temperature thermoelectric transport property measurements have been performed on the highly c-axis oriented Bi2Sr2Co20v thin films prepared by pulsed laser deposition on LaA1Oa (001). Both the electric resisti... High-temperature thermoelectric transport property measurements have been performed on the highly c-axis oriented Bi2Sr2Co20v thin films prepared by pulsed laser deposition on LaA1Oa (001). Both the electric resistivity p and the seebeck coefficient S of the film exhibit an increasing trend with the temperature from 300 K-1000 K and reach up to 4.8 m. cm and 202 V/K at 980 K, resulting in a power factor of 0.85 mW/mK which are comparable to those of the single crystalline samples. A small polaron hopping conduction can be responsible for the conduction mechanism of the film at high temperature. The results demonstrate that the Bi2Sr2Co2Oy thin film has potential application has high temperature thin film thermoelectric devices, 展开更多
关键词 high temperature thermoelectric properties Bi2Sr2Co2Oy thin films c-axis oriented pulsed laser deposition
下载PDF
Experimental-computational study of fibrous particle transport and deposition in a bifurcating lung model 被引量:3
2
作者 Xiaole Chen Wenqi Zhong +3 位作者 Josin Tom Clement Kleinstreuer Yu Feng Xiaopu He 《Particuology》 SCIE EI CAS CSCD 2016年第5期102-113,共12页
Experiments carried out using a lung model with a single horizontal bifurcation under different steady inhalation conditions explored the orientation of depositing carbon fibers, and particle deposition frac- tions. T... Experiments carried out using a lung model with a single horizontal bifurcation under different steady inhalation conditions explored the orientation of depositing carbon fibers, and particle deposition frac- tions. The orientations of deposited fibers were obtained from micrographs. Specifically, the effects of the sedimentation parameter (γ), fiber length, and flow rate on orientations were analyzed. Our results indicate that gravitational effect on deposition cannot be neglected for 0.0228 〈 γ 〈 0.247. The absolute orientation angle of depositing fibers decreased linearly with increasing y for values 0.0228 〈 γ 〈 0.15. Correspondence between Stokes numbers and y suggests these characteristics can be used to estimate fiber deposition in the lower airways. Computer simulations with sphere-equivalent diameter models for the fibers explored deposition efficiency vs. Stokes number. Using the volume-equivalent diameter model, our experimental data for the horizontal bifurcation were replicated. Results for particle deposition using a lung model with a vertical bifurcation indicate that body position also affects deposition. 展开更多
关键词 Lung aerosol dynamics Image-processing method Fiber deposition data Computer simulations Deposited fiber orientations
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部